{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T00:22:54Z","timestamp":1760746974484,"version":"build-2065373602"},"reference-count":7,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:00:00Z","timestamp":1760659200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:00:00Z","timestamp":1760659200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Endoscopic aortic valve replacement (TE\u2011AVR) is hindered by restricted visualization and instrument maneuverability. We describe TATEGIRI (Japanese: \u201cvertical cut\u201d), a longitudinal aortotomy adapted for the endoscopic setting.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Between August 2023 and August 2024, 28 consecutive patients (23 sternotomies and five MICS) underwent AVR using the TATEGIRIapproach. Perioperative variables, procedural feasibility, and early outcomes were prospectively assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The median cardiopulmonary bypass time was 142\u00a0min and the aortic cross-clamp time was 97\u00a0min. Valve size distribution was 19\u00a0mm in one patient (3.6%), 23\u00a0mm in eight (28.6%), 25\u00a0mm in seven (25%), 27\u00a0mm in five (17.9%), and 29\u00a0mm in one (3.6%). The mean prosthesis diameter was 24.5\u2009\u00b1\u20093.1\u00a0mm. In the five totally endoscopic cases, the median prosthesis diameter was 25\u00a0mm (interquartile range [IQR] 23\u201327) versus 23\u00a0mm (IQR 23\u201325) in full\u2011sternotomy cases (<jats:italic>p<\/jats:italic>\u2009=\u20090.09). Two patients underwent reintervention (one reexploration for bleeding and one sternal rewiring). There were two 30\u2011day mortalities (sepsis and stroke, both in patients who underwent sternotomy). Paravalvular leakage was not observed. The median length of the hospital stay was 13 days. Follow-up CT at a median of 3.5 months showed no aneurysmal change or stenosis and demonstrated an average 2\u00a0mm reduction in aortic diameter along the aortotomy line.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>TATEGIRI longitudinal aortotomy provides consistent three-quarters (~\u2009270\u00b0) annular exposure while preserving a straight, fully visible suture line. Early results demonstrated technical feasibility and favorable short-term outcomes, supporting wider adoption and evaluation in comparative studies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s13019-025-03613-5","type":"journal-article","created":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T13:18:43Z","timestamp":1760707123000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The TATEGIRI technique: adaptation of a longitudinal aortotomy for totally endoscopic aortic valve replacement"],"prefix":"10.1186","volume":"20","author":[{"given":"Hitoki","family":"Hashiguchi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naomi","family":"Yasuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihito","family":"Ohkawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,17]]},"reference":[{"key":"3613_CR1","first-page":"510","volume":"73","author":"M Tokoro","year":"2020","unstructured":"Tokoro M, Sawaki S, Ozeki T, Orii M, Kato R, Ito T. Totally endoscopic aortic valve replacement using the three-dimensional endoscope. Kyobu Geka. 2020;73:510\u20135.","journal-title":"Kyobu Geka"},{"key":"3613_CR2","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1093\/icvts\/ivz287","volume":"30","author":"M Tokoro","year":"2020","unstructured":"Tokoro M, Sawaki S, Ozeki T, Orii M, Usui A, Ito T. Totally endoscopic aortic valve replacement via an anterolateral approach using a standard prosthesis. Interact Cardiovasc Thorac Surg. 2020;30:424\u201330. https:\/\/doi.org\/10.1093\/icvts\/ivz287.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"3613_CR3","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3978\/j.issn.2225-319X.2014.09.25","volume":"4","author":"M Vola","year":"2015","unstructured":"Vola M, Fuzellier J\u2013F, Campisi S, Faure M, Bouchet J\u2013B, Sandri F, et al. Totally endoscopic aortic valve replacement (TEAVR). Ann Cardiothorac Surg. 2015;4:196\u20137. https:\/\/doi.org\/10.3978\/j.issn.2225-319X.2014.09.25.","journal-title":"Ann Cardiothorac Surg"},{"key":"3613_CR4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/rcs.1598","volume":"11","author":"M Moscarelli","year":"2015","unstructured":"Moscarelli M, Harling L, Ashrafian H, Athanasiou T, Casula R. Challenges facing totally endoscopic robotic coronary artery bypass grafting. Int J Med Robot. 2015;11:18\u201329. https:\/\/doi.org\/10.1002\/rcs.1598.","journal-title":"Int J Med Robot"},{"key":"3613_CR5","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.1106845","volume":"9","author":"W Gu","year":"2022","unstructured":"Gu W, Zhou K, Wang Z, Zang X, Guo H, Gao Q, et al. Totally endoscopic aortic valve replacement: techniques and early results. Front Cardiovasc Med. 2022;9:1106845. https:\/\/doi.org\/10.3389\/fcvm.2022.1106845.","journal-title":"Front Cardiovasc Med"},{"key":"3613_CR6","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2024.1468452","author":"H Nguyen","year":"2024","unstructured":"Nguyen H, Pham DT. Totally 3D endoscopic aortic valve replacement: initial results and experience from a single center. Front Cardiovasc Med. 2024. https:\/\/doi.org\/10.3389\/fcvm.2024.1468452.","journal-title":"Front Cardiovasc Med"},{"key":"3613_CR7","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1053\/j.semtcvs.2020.01.002","volume":"32","author":"G Cresce","year":"2020","unstructured":"Cresce G, Sella M, Danesi TH, Favaro A, Salvador L. Minimally invasive endoscopic aortic valve replacement: operative results. Semin Thorac Cardiovasc Surg. 2020;32:217\u201324. https:\/\/doi.org\/10.1053\/j.semtcvs.2020.01.002.","journal-title":"Semin Thorac Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03613-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-025-03613-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03613-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T13:18:46Z","timestamp":1760707126000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-025-03613-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,17]]},"references-count":7,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3613"],"URL":"https:\/\/doi.org\/10.1186\/s13019-025-03613-5","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,17]]},"assertion":[{"value":"31 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"363"}}