{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T11:22:02Z","timestamp":1762168922385,"version":"build-2065373602"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T00:00:00Z","timestamp":1762128000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T00:00:00Z","timestamp":1762128000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Central venous catheter (CVC) insertion is a common procedure providing direct access to the central venous system. Potential mechanical, infectious, and embolic complications could occur. Malpositioning into the pulmonary artery is a very rare complication. A modified Blalock-Taussig shunt (MBTS), anatomically positioned between the subclavian and the pulmonary arteries and adjacent to the right internal jugular vein, is the most common procedure performed in children with complex congenital heart disease (CHD) to enhance pulmonary artery blood flow. Here, we present an infant with a complex CHD and an MBTS in whom a CVC was placed under ultrasound guidance. The misplacement of the CVC was suspected due to deviation of the CVC in chest radiography, elevated PvO2 levels obtained from the CVC, and an increased central venous pressure recorded via the CVC. Cardiac catheterization confirmed that the CVC tip was located in the pulmonary artery, having been inserted through MBTS. The catheter likely traversed the right carotid artery, subclavian artery, Blalock-Taussig (BT) shunt, and pulmonary artery.<\/jats:p>","DOI":"10.1186\/s13019-025-03638-w","type":"journal-article","created":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T11:06:28Z","timestamp":1762167988000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Inadvertent insertion of a subclavian central venous catheter into the pulmonary artery through a Blalock-Taussig shunt: a rare complication of a common procedure"],"prefix":"10.1186","volume":"20","author":[{"given":"Mehdi","family":"Ghaderian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohadeseh","family":"Ghasemi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,3]]},"reference":[{"issue":"1","key":"3638_CR1","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13244-019-0770-2","volume":"10","author":"S Machat","year":"2019","unstructured":"Machat S, Eisenhuber E, Pfarl G, St\u00fcbler J, Koelblinger C, Zacherl J, et al. Complications of central venous port systems: a pictorial review. Insights into Imaging. 2019;10(1):86.","journal-title":"Insights into Imaging"},{"issue":"9","key":"3638_CR2","doi-asserted-by":"publisher","DOI":"10.3390\/jpm12091537","volume":"12","author":"G Papastratigakis","year":"2022","unstructured":"Papastratigakis G, Marouli D, Proklou A, Nasis N, Kondili E, Kehagias E. Management of inadvertent arterial catheterization during central venous catheter placement: a case series. J Pers Med. 2022;12(9):1537.","journal-title":"J Pers Med"},{"key":"3638_CR3","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.f6570","author":"RN Smith","year":"2013","unstructured":"Smith RN, Nolan JP. Central venous catheters. BMJ. 2013;347:f6570. https:\/\/doi.org\/10.1136\/bmj.f6570","journal-title":"BMJ"},{"key":"3638_CR4","doi-asserted-by":"crossref","unstructured":"Gu X, Paulsen W, Tisnado J, He Y, Li Z, Nixon JI. Malposition of a central venous catheter in the right main pulmonary artery detected by transesophageal echocardiography. J Am Soc Echocardiogr. 2009;22(12):1420. e5-. e7.","DOI":"10.1016\/j.echo.2009.07.009"},{"key":"3638_CR5","doi-asserted-by":"crossref","unstructured":"Fraser CD Jr, McKenzie ED, Cooley DA. Tetralogy of fallot: surgical management individualized to the patient. Ann Thorac Surg. 2001;71(5):1556\u201363.","DOI":"10.1016\/S0003-4975(01)02475-4"},{"key":"3638_CR6","unstructured":"Turetta F, Brotto P, De Stefani R, Cannizzaro A, Simone M, editors. Mediastinal infusion by a multilumen central venous catheter. Annales Francaises D\u2019anesthesie et de Reanimation; 1987."},{"issue":"1","key":"3638_CR7","volume":"2012","author":"J Moriceau","year":"2012","unstructured":"Moriceau J, Comp\u00e8re V, Bigo M, Dureuil B. Accidental puncture of the pulmonary artery during a subclavian central venous catheterization. Case Rep Crit Care. 2012;2012(1):160847.","journal-title":"Case Rep Crit Care"},{"issue":"5","key":"3638_CR8","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1016\/S0003-4975(00)01078-X","volume":"69","author":"AM Alkhulaifi","year":"2000","unstructured":"Alkhulaifi AM, Lacour-Gayet F, Serraf A, Belli E, Planch\u00e9 C. Systemic pulmonary shunts in neonates: early clinical outcome and choice of surgical approach. Ann Thorac Surg. 2000;69(5):1499\u2013504.","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"3638_CR9","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1111\/pan.12802","volume":"26","author":"M Long","year":"2016","unstructured":"Long M, Goh PS, Ti LK. Inadvertent insertion of central venous catheter into a Blalock-Taussig shunt\u2014a rare complication. Pediatr Anesth. 2016;26(3):322\u20134.","journal-title":"Pediatr Anesth"},{"issue":"3","key":"3638_CR10","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1053\/j.jvca.2015.07.009","volume":"30","author":"S Merchant-Soomar","year":"2016","unstructured":"Merchant-Soomar S, Grignani R, Aye WM, Shankar S, Quek SC. Why are the saturations dropping? The Blalock-Taussig shunt revisited. J Cardiothorac Vasc Anesth. 2016;30(3):753\u20135.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"3638_CR11","unstructured":"National Institute for Clinical Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology appraisal guidance No. 49 (TA49). London: NICE. 2002."},{"key":"3638_CR12","doi-asserted-by":"crossref","unstructured":"Practice Guidelines for Central Venous Access. 2020: An Updated Report by the American Society of Anesthesiologists Task Force on Central Venous Access*. Anesthesiology. 2020;132(1):8\u201343.","DOI":"10.1097\/ALN.0000000000002864"},{"issue":"1","key":"3638_CR13","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/00000542-199907000-00013","volume":"91","author":"ST Verghese","year":"1999","unstructured":"Verghese ST, McGill WA, Patel RI, Sell JE, Midgley FM, Ruttimann UE. Ultrasound-guided internal jugular venous cannulation in infants: a prospective comparison with the traditional palpation method. J Am Soc Anesthesiol. 1999;91(1):71\u20137.","journal-title":"J Am Soc Anesthesiol"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03638-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-025-03638-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03638-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T11:06:31Z","timestamp":1762167991000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-025-03638-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,3]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3638"],"URL":"https:\/\/doi.org\/10.1186\/s13019-025-03638-w","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,3]]},"assertion":[{"value":"24 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This case report was approved by the Isfahan University of Medical Sciences Ethics Committee. Informed consent for participation and publication was obtained from the parents of the infant prior to the report being written.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent for publication of the case details and any associated images was obtained from the parents of the infant.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"414"}}