{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T01:06:53Z","timestamp":1770167213549,"version":"3.49.0"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T00:00:00Z","timestamp":1767484800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T00:00:00Z","timestamp":1770076800000},"content-version":"vor","delay-in-days":30,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"DOI":"10.1186\/s13019-025-03836-6","type":"journal-article","created":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T14:33:26Z","timestamp":1767537206000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ablation catheter entrapment in the mitral valve apparatus during ablation of premature ventricular complexes: a case report"],"prefix":"10.1186","volume":"21","author":[{"given":"Fan","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuelian","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Litian","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feifei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinning","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Dang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,4]]},"reference":[{"issue":"8","key":"3836_CR1","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1093\/europace\/euz132","volume":"21","author":"EM Cronin","year":"2019","unstructured":"Cronin EM, Bogun FM, Maury P, et al. 2019 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Europace. 2019;21(8):1143\u20134. https:\/\/doi.org\/10.1093\/europace\/euz132.","journal-title":"Europace"},{"key":"3836_CR2","doi-asserted-by":"crossref","unstructured":"Gagnier JJ, Kienle G, Altman DG, CARE Group, et al. The CARE guidelines: consensus-based clinical case reporting guideline development. Headache. 2013;53(10):1541\u20137.","DOI":"10.1111\/head.12246"},{"issue":"1","key":"3836_CR3","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.hrthm.2006.09.016","volume":"4","author":"M Kesek","year":"2007","unstructured":"Kesek M, Englund A, Jensen SM, Jensen-Urstad M. Entrapment of circular mapping catheter in the mitral valve. Heart Rhythm. 2007;4(1):17\u20139. https:\/\/doi.org\/10.1016\/j.hrthm.2006.09.016.","journal-title":"Heart Rhythm"},{"issue":"2","key":"3836_CR4","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.hrcr.2015.11.006","volume":"2","author":"SH Sheldon","year":"2016","unstructured":"Sheldon SH, Good E. PentaRay entrapment in a mechanical mitral valve during catheter ablation of atrial fibrillation. HeartRhythm Case Rep. 2016;2(2):200\u20131. https:\/\/doi.org\/10.1016\/j.hrcr.2015.11.006.","journal-title":"HeartRhythm Case Rep"},{"issue":"10","key":"3836_CR5","doi-asserted-by":"publisher","first-page":"1681","DOI":"10.1111\/j.1540-8159.1994.tb02365.x","volume":"17","author":"JB Conti","year":"1994","unstructured":"Conti JB, Geiser E, Curtis AB. Catheter entrapment in the mitral valve apparatus during radiofrequency ablation. Pacing Clin Electrophysiol. 1994;17(10):1681\u20135. https:\/\/doi.org\/10.1111\/j.1540-8159.1994.tb02365.x.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"3836_CR6","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1111\/j.1540-8167.2011.02206.x","volume":"23","author":"K Kim","year":"2012","unstructured":"Kim K, Choi K, Kim S, Nam G, Kim Y. Ablation catheter entrapment by chordae tendineae in the mitral valve during ventricular tachycardia ablation. Cardiovasc Electrophysiol. 2012;23(2):218\u201320. https:\/\/doi.org\/10.1111\/j.1540-8167.2011.02206.x.","journal-title":"Cardiovasc Electrophysiol"},{"issue":"9","key":"3836_CR7","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1111\/jce.12439","volume":"25","author":"CV Desimone","year":"2014","unstructured":"Desimone CV, Hu T, Ebrille E, et al. Catheter ablation related mitral valve injury: the importance of early recognition and rescue mitral valve repair. Cardiovasc Electrophysiol. 2014;25(9):971\u20135. https:\/\/doi.org\/10.1111\/jce.12439.","journal-title":"Cardiovasc Electrophysiol"},{"issue":"1","key":"3836_CR8","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1111\/jce.15313","volume":"33","author":"K Benali","year":"2022","unstructured":"Benali K, Hammache N, Sellal J, Mazen E, De Chillou C. Catheter knot around the mitral valve apparatus: an exceptional complication of remote magnetic navigation. Cardiovasc Electrophysiol. 2022;33(1):137\u20139. . https:\/\/doi.org\/10.1111\/jce.15313","journal-title":"Cardiovasc Electrophysiol"},{"issue":"4","key":"3836_CR9","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1111\/j.1540-8159.1998.tb00138.x","volume":"21","author":"MK Mandawat","year":"1998","unstructured":"Mandawat MK, Turitto G, El-Sherif N. Catheter entrapment in the mitral valve apparatus requiring surgical removal: an unusual complication of radiofrequency ablation. Pacing Clin Electrophysiol. 1998;21(4):772\u20133. https:\/\/doi.org\/10.1111\/j.1540-8159.1998.tb00138.x.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"3836_CR10","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.hrcr.2016.09.008","volume":"3","author":"R Fujiwara","year":"2017","unstructured":"Fujiwara R, Takami M, Kijima Y, et al. A case of an ablation catheter entrapped in the pulmonary vein during atrial fibrillation ablation requiring open heart surgery for removal. HeartRhythm Case Rep. 2017;3(1):87\u20139. https:\/\/doi.org\/10.1016\/j.hrcr.2016.09.008.","journal-title":"HeartRhythm Case Rep"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-025-03836-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03836-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03836-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T12:06:17Z","timestamp":1770120377000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13019-025-03836-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,4]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3836"],"URL":"https:\/\/doi.org\/10.1186\/s13019-025-03836-6","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,4]]},"assertion":[{"value":"22 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval to report this case was obtained from Ethics Committee of Hebei General Hospital (2024-LW-0211).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"68"}}