{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T02:07:18Z","timestamp":1789092438710,"version":"build-2803163510"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:00:00Z","timestamp":1789084800000},"content-version":"vor","delay-in-days":98,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"DOI":"10.1186\/s13019-026-04292-6","type":"journal-article","created":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T14:55:32Z","timestamp":1780671332000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Stented vs. stentless in aortic stenosis: a systematic review and meta-analysis"],"prefix":"10.1186","volume":"21","author":[{"given":"Abdelrahman","family":"Saeed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyrillos Mahrous","family":"Gerges","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Saeed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirvat","family":"Alasnag","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Whitlock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick O.","family":"Myers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lognathen","family":"Balacumaraswami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alzahraa Faris","family":"Alesawy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Abraheem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dina","family":"Elraggal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dua Rajab","family":"Khalleefah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulmoez Fauzi","family":"Elmesherghi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammar","family":"Fahaid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nizar","family":"Aljefairi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammed","family":"Elhadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mamas","family":"Mamas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,5]]},"reference":[{"issue":"11","key":"4292_CR1","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.jacc.2013.05.015","volume":"62","author":"RL Osnabrugge","year":"2013","unstructured":"Osnabrugge RL, et al. Aortic stenosis in the elderly: disease prevalence and number of candidates for transcatheter aortic valve replacement: a meta-analysis and modeling study. J Am Coll Cardiol. 2013;62(11):1002\u201312.","journal-title":"J Am Coll Cardiol"},{"issue":"23","key":"4292_CR2","doi-asserted-by":"publisher","first-page":"2440","DOI":"10.1161\/CIR.0000000000000029","volume":"129","author":"RA Nishimura","year":"2014","unstructured":"Nishimura RA, et al. 2014 AHA\/ACC Guideline for the Management of Patients With Valvular Heart Disease: executive summary: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines. Circulation. 2014;129(23):2440\u201392.","journal-title":"Circulation"},{"issue":"2","key":"4292_CR3","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/S0022-5223(19)35899-4","volume":"92","author":"AP Yoganathan","year":"1986","unstructured":"Yoganathan AP, et al. In vitro hemodynamic characteristics of tissue bioprostheses in the aortic position. J Thorac Cardiovasc Surg. 1986;92(2):198\u2013209.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"4292_CR4","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.athoracsur.2007.02.057","volume":"84","author":"B Kunadian","year":"2007","unstructured":"Kunadian B, et al. Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves. Ann Thorac Surg. 2007;84(1):73\u20138.","journal-title":"Ann Thorac Surg"},{"issue":"22","key":"4292_CR5","doi-asserted-by":"publisher","first-page":"1561","DOI":"10.1056\/NEJM199005313222203","volume":"322","author":"D Levy","year":"1990","unstructured":"Levy D, et al. Prognostic implications of echocardiographically determined left ventricular mass in the Framingham Heart Study. N Engl J Med. 1990;322(22):1561\u20136.","journal-title":"N Engl J Med"},{"issue":"4 Suppl 1","key":"4292_CR6","first-page":"98","volume":"11","author":"KL Yun","year":"1999","unstructured":"Yun KL, et al. Prosthesis-patient mismatch: hemodynamic comparison of stented and stentless aortic valves. Semin Thorac Cardiovasc Surg. 1999;11(4 Suppl 1):98\u2013102.","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"4292_CR7","doi-asserted-by":"crossref","unstructured":"Borger MA, Prasongsukarn K, Armstrong S, Feindel CM, David TE. Stentless aortic valve reoperations: a surgical challenge. Ann Thorac Surg. 2007;84(3):737-744. doi:10.1016\/j.athoracsur.2007.04.061","DOI":"10.1016\/j.athoracsur.2007.04.061"},{"issue":"5","key":"4292_CR8","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1111\/j.1540-8191.2008.00705.x","volume":"23","author":"DM Payne","year":"2008","unstructured":"Payne DM, et al. Hemodynamic performance of stentless versus stented valves: a systematic review and meta-analysis. J Card Surg. 2008;23(5):556\u201364.","journal-title":"J Card Surg"},{"key":"4292_CR9","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71.","journal-title":"BMJ"},{"key":"4292_CR10","doi-asserted-by":"publisher","first-page":"j4008","DOI":"10.1136\/bmj.j4008","volume":"358","author":"BJ Shea","year":"2017","unstructured":"Shea BJ, et al. AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both. BMJ. 2017;358:j4008.","journal-title":"BMJ"},{"issue":"1","key":"4292_CR11","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/S0003-4975(01)02672-8","volume":"72","author":"AD Milano","year":"2001","unstructured":"Milano AD, et al. Hemodynamic performance of stented and stentless aortic bioprostheses. Ann Thorac Surg. 2001;72(1):33\u20138.","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"4292_CR12","doi-asserted-by":"publisher","first-page":"E205","DOI":"10.1532\/HSF98.20061163","volume":"10","author":"D Tsialtas","year":"2007","unstructured":"Tsialtas D, et al. Stented versus stentless bioprostheses in aortic valve stenosis: effect on left ventricular remodelling. Heart Surg Forum. 2007;10(3):E205\u201310.","journal-title":"Heart Surg Forum"},{"key":"4292_CR13","doi-asserted-by":"publisher","first-page":"l4898","DOI":"10.1136\/bmj.l4898","volume":"366","author":"JAC Sterne","year":"2019","unstructured":"Sterne JAC, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019;366:l4898.","journal-title":"BMJ"},{"key":"4292_CR14","doi-asserted-by":"publisher","first-page":"i4919","DOI":"10.1136\/bmj.i4919","volume":"355","author":"JA Sterne","year":"2016","unstructured":"Sterne JA, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016;355:i4919.","journal-title":"BMJ"},{"key":"4292_CR15","doi-asserted-by":"crossref","unstructured":"Identifying and Quantifying Heterogeneity, in Introduction to Meta-Analysis. 2009. pp. 107\u2013125.","DOI":"10.1002\/9780470743386.ch16"},{"issue":"7109","key":"4292_CR16","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","volume":"315","author":"M Egger","year":"1997","unstructured":"Egger M, et al. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315(7109):629\u201334.","journal-title":"BMJ"},{"issue":"4","key":"4292_CR17","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.jclinepi.2010.09.011","volume":"64","author":"GH Guyatt","year":"2011","unstructured":"Guyatt GH, et al. GRADE guidelines: a new series of articles in the Journal of Clinical Epidemiology. J Clin Epidemiol. 2011;64(4):380\u20132.","journal-title":"J Clin Epidemiol"},{"issue":"6","key":"4292_CR18","doi-asserted-by":"publisher","first-page":"2162","DOI":"10.1016\/j.athoracsur.2007.01.021","volume":"83","author":"A Ali","year":"2007","unstructured":"Ali A, et al. Early clinical and hemodynamic outcomes after stented and stentless aortic valve replacement: results from a randomized controlled trial. Ann Thorac Surg. 2007;83(6):2162\u20138.","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"4292_CR19","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/j.ejcts.2006.07.017","volume":"30","author":"T Bov\u00e9","year":"2006","unstructured":"Bov\u00e9 T, et al. Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome. Eur J Cardiothorac Surg. 2006;30(5):706\u201313.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"20","key":"4292_CR20","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1016\/j.jacc.2009.01.060","volume":"53","author":"MA Clavel","year":"2009","unstructured":"Clavel MA, et al. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol. 2009;53(20):1883\u201391.","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"4292_CR21","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/j.ijcard.2004.03.043","volume":"97","author":"J Collinson","year":"2004","unstructured":"Collinson J, et al. Influence of valve prosthesis type on the recovery of ventricular dysfunction and subendocardial ischaemia following valve replacement for aortic stenosis. Int J Cardiol. 2004;97(3):535\u201341.","journal-title":"Int J Cardiol"},{"issue":"3","key":"4292_CR22","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/s1010-7940(02)00815-1","volume":"23","author":"M Doss","year":"2003","unstructured":"Doss M, et al. Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial. Eur J Cardiothorac Surg. 2003;23(3):299\u2013304.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"2","key":"4292_CR23","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/s10840-006-7750-4","volume":"15","author":"M Elahi","year":"2006","unstructured":"Elahi M, Usmaan K. The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery. J Interv Card Electrophysiol. 2006;15(2):113\u20138.","journal-title":"J Interv Card Electrophysiol"},{"issue":"1","key":"4292_CR24","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.jjcc.2016.04.016","volume":"69","author":"O Fouquet","year":"2017","unstructured":"Fouquet O, et al. Influence of stentless versus stented valves on ventricular remodeling assessed at 6 months by magnetic resonance imaging and long-term follow-up. J Cardiol. 2017;69(1):264\u201371.","journal-title":"J Cardiol"},{"issue":"4","key":"4292_CR25","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1016\/j.jtcvs.2016.06.058","volume":"152","author":"A Ghoneim","year":"2016","unstructured":"Ghoneim A, et al. Management of small aortic annulus in the era of sutureless valves: A comparative study among different biological options. J Thorac Cardiovasc Surg. 2016;152(4):1019\u201328.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"5","key":"4292_CR26","doi-asserted-by":"publisher","first-page":"pE462","DOI":"10.1532\/HSF98.20041096","volume":"7","author":"MJ Jasinski","year":"2004","unstructured":"Jasinski MJ, et al. Early regional assessment of LV mass regression and function after stentless valve replacement: comparative randomized study. Heart Surg Forum. 2004;7(5):pE462\u20135.","journal-title":"Heart Surg Forum"},{"issue":"1","key":"4292_CR27","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1136\/heartjnl-2012-302256","volume":"99","author":"JP Khoo","year":"2013","unstructured":"Khoo JP, et al. Differences in performance of five types of aortic valve prostheses: haemodynamic assessment by dobutamine stress echocardiography. Heart. 2013;99(1):41\u20137.","journal-title":"Heart"},{"issue":"6","key":"4292_CR28","first-page":"446","volume":"63","author":"T Murashita","year":"2015","unstructured":"Murashita T, et al. Efficacy of Stentless Aortic Bioprosthesis Implantation for Aortic Stenosis with Small Aortic Annulus. Thorac Cardiovasc Surg. 2015;63(6):446\u201351.","journal-title":"Thorac Cardiovasc Surg"},{"issue":"17","key":"4292_CR29","doi-asserted-by":"publisher","first-page":"2696","DOI":"10.1161\/CIRCULATIONAHA.104.521161","volume":"112","author":"D de Perez","year":"2005","unstructured":"de Perez D, et al. Randomized comparison of stentless versus stented valves for aortic stenosis: effects on left ventricular mass. Circulation. 2005;112(17):2696\u2013702.","journal-title":"Circulation"},{"issue":"11","key":"4292_CR30","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/S0894-7317(99)70152-5","volume":"12","author":"P Pibarot","year":"1999","unstructured":"Pibarot P, et al. Changes in left ventricular mass and function after aortic valve replacement: a comparison between stentless and stented bioprosthetic valves. J Am Soc Echocardiogr. 1999;12(11):981\u20137.","journal-title":"J Am Soc Echocardiogr"},{"issue":"4","key":"4292_CR31","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1510\/icvts.2008.181362","volume":"8","author":"PS Risteski","year":"2009","unstructured":"Risteski PS, et al. Prospective randomized evaluation of stentless vs. stented aortic biologic prosthetic valves in the elderly at five years. Interact Cardiovasc Thorac Surg. 2009;8(4):449\u201353.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"4292_CR32","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1186\/s13019-015-0219-8","volume":"10","author":"R Tavakoli","year":"2015","unstructured":"Tavakoli R, et al. Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves. J Cardiothorac Surg. 2015;10:15.","journal-title":"J Cardiothorac Surg"},{"issue":"5","key":"4292_CR33","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/S1010-7940(98)00058-X","volume":"13","author":"HL Thomson","year":"1998","unstructured":"Thomson HL, et al. Haemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement. Eur J Cardiothorac Surg. 1998;13(5):572\u20135.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"3","key":"4292_CR34","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/j.athoracsur.2022.01.029","volume":"114","author":"B Yang","year":"2022","unstructured":"Yang B, et al. Stentless Versus Stented Aortic Valve Replacement for Aortic Stenosis. Ann Thorac Surg. 2022;114(3):728\u201334.","journal-title":"Ann Thorac Surg"},{"issue":"1 Suppl","key":"4292_CR35","first-page":"I535","volume":"114","author":"A Ali","year":"2006","unstructured":"Ali A, et al. Are stentless valves superior to modern stented valves? A prospective randomized trial. Circulation. 2006;114(1 Suppl):I535\u201340.","journal-title":"Circulation"},{"issue":"2","key":"4292_CR36","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/imi.0b013e3181a34872","volume":"4","author":"D Cheng","year":"2009","unstructured":"Cheng D, et al. Stentless versus stented bioprosthetic aortic valves: a systematic review and meta-analysis of controlled trials. Innovations (Phila). 2009;4(2):61\u201373.","journal-title":"Innovations (Phila)"},{"issue":"6","key":"4292_CR37","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1097\/IMI.0000000000000569","volume":"13","author":"A Harky","year":"2018","unstructured":"Harky A, et al. Stented Versus Stentless Aortic Valve Replacement in Patients With Small Aortic Root: A Systematic Review and Meta-Analysis. Innovations (Phila). 2018;13(6):404\u201316.","journal-title":"Innovations (Phila)"},{"issue":"2","key":"4292_CR38","first-page":"83","volume":"4","author":"J Cremer","year":"2012","unstructured":"Cremer J, et al. Stented bioprostheses in aortic position. HSR Proc Intensive Care Cardiovasc Anesth. 2012;4(2):83\u20137.","journal-title":"HSR Proc Intensive Care Cardiovasc Anesth"},{"issue":"3","key":"4292_CR39","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.hlc.2020.06.015","volume":"30","author":"O Stanger","year":"2021","unstructured":"Stanger O, et al. Reduced Permanent Pacemaker Implantation in Patients With Stentless Freedom SOLO Compared With Stented Perimount Magna Aortic Bioprostheses: A Propensity Score Weighted Analysis. Heart Lung Circ. 2021;30(3):423\u201330.","journal-title":"Heart Lung Circ"},{"issue":"5","key":"4292_CR40","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s11748-018-0884-3","volume":"66","author":"R Tavakoli","year":"2018","unstructured":"Tavakoli R, et al. Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review. Gen Thorac Cardiovasc Surg. 2018;66(5):247\u201356.","journal-title":"Gen Thorac Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-026-04292-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-026-04292-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-026-04292-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T01:42:25Z","timestamp":1789090945000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13019-026-04292-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,5]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4292"],"URL":"https:\/\/doi.org\/10.1186\/s13019-026-04292-6","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,5]]},"assertion":[{"value":"24 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In preparing this systematic review and meta-analysis, artificial intelligence tools were used solely for grammar correction and style enhancement. All scientific content, data interpretation, and intellectual analyses were conducted exclusively by the authors. The use of AI was limited to improving the clarity, readability, and linguistic accuracy of the manuscript without altering the scientific meaning or findings.","order":2,"name":"Ethics","label":"Declaration of AI Usage","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"694"}}