{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T01:41:15Z","timestamp":1789004475090,"version":"build-2803163510"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T00:00:00Z","timestamp":1701216000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T00:00:00Z","timestamp":1701216000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100005566","name":"Ethicon Endo-Surgery","doi-asserted-by":"publisher","award":["-"],"award-info":[{"award-number":["-"]}],"id":[{"id":"10.13039\/100005566","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Stichting Vrienden Diergeneeskunde","award":["-"],"award-info":[{"award-number":["-"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Vet Scand"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Advanced bipolar tissue sealer\/dividers provide the most reliable and efficient means of tissue dissection and blood vessel sealing in laparoscopic surgery and the techniques are continuously improved. In veterinary practice, cost-effectiveness is of major impact, leading to re-use of instruments designed and sold for single use. Two high-end devices were evaluated and compared in a highly standardized laparoscopic ovariectomy procedure in dogs: The new generation Ligasure Maryland Sealer\/Divider (LMSD) with improved atraumatic curved jaw shape for delicate tissue handling and dissection and non-stick nanocoating, and the new-generation Articulating Enseal G2 (AENG2) with several proclaimed features improving surgical performance, including articulation of the forceps tip; improved tissue compression during sealing; unique offset electrode configuration; and specific nanoparticle coating minimizing thermal spread and tissue sticking. Twenty-one client-owned dogs admitted for elective laparoscopic ovariectomy were randomly assigned to one of two groups: ovariectomy using AENG2 on the left ovary and LMSD in the right ovary or\n                      <jats:italic>vice-versa<\/jats:italic>\n                      . Procedural video recordings were used to assess ovarian ligament fat score, smoke formation, occurrence of bleeding, and excision duration. Excised tissues were examined histopathologically and collateral thermal damage was scored in three anatomic zones: suspensory ligament, vascular pedicle, and uterine junction. Tissue sealers were used repeatedly following standardized cleaning protocol with instrument washing machine and ethylene oxide gas sterilization and the number of uses until device failure was recorded.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Excision times were significantly increased for AENG2 (median 01:35\u00a0min) compared to LMSD (median 01:00\u00a0min). Minor hemorrhage from incomplete sealing occurred in 3 sites in 2 patients (2x AENG2, 1x LMSD) and was not significantly different between groups. Smoke production as scored on videos and thermal tissue damage scores on histopathology also did not differ between AENG2 and LMSD. Both vessel sealers could be re-used repeatedly.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>AENG2 provides a good alternative to LMSD in laparoscopic ovariectomy, with only minor differences in measured variables. Subjectively, the articulating feature of AENG2 did not improve surgical performance in laparoscopic ovariectomy and the use of LMSD appeared more straight-forward for this specific procedure. However, differences in operating these devices may be subject to personal preference.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13028-023-00715-9","type":"journal-article","created":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T10:02:16Z","timestamp":1701252136000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of two advanced bipolar tissue sealer\/dividers for laparoscopic ovariectomy in dogs: articulating enseal G2 versus Ligasure Maryland device"],"prefix":"10.1186","volume":"65","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6965-1782","authenticated-orcid":false,"given":"Floor","family":"Driessen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier Deniz","family":"Marrero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy Cornelis Maria","family":"Grinwis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastiaan Alexander","family":"van Nimwegen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,29]]},"reference":[{"key":"715_CR1","doi-asserted-by":"publisher","first-page":"1228","DOI":"10.1007\/s00464-002-8833-7","volume":"17","author":"KL Harold","year":"2003","unstructured":"Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003;17:1228\u201330.","journal-title":"Surg Endosc"},{"key":"715_CR2","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1007\/s00464-008-9932-x","volume":"23","author":"WL Newcomb","year":"2009","unstructured":"Newcomb WL, Hope WW, Schmelzer TM, Heath JJ, Norton HJ, Lincourt AE, et al. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices. Surg Endosc. 2009;23:90\u20136.","journal-title":"Surg Endosc"},{"key":"715_CR3","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1053\/jvet.2003.50052","volume":"32","author":"BEBJ van Goethem","year":"2003","unstructured":"van Goethem BEBJ, Rosenveldt KW. Kirpensteijn.Monopolar versus bipolar electrocoagulation in canine laparoscopic ovariectomy: a nonrandomized, prospective, clinical trial. Vet Surg. 2003;32:464\u201370.","journal-title":"Vet Surg"},{"key":"715_CR4","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1111\/j.1532-950X.2007.00304.x","volume":"36","author":"SA van Nimwegen","year":"2007","unstructured":"van Nimwegen SA, Kirpensteijn J. Comparison of nd:YAG surgical laser and remorgida bipolar electrosurgery forceps for canine laparoscopic ovariectomy. Vet Surg. 2007;36:533\u201340.","journal-title":"Vet Surg"},{"key":"715_CR5","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1111\/vsu.12640","volume":"46","author":"AL Spillebeen","year":"2017","unstructured":"Spillebeen AL, Janssens SDS, Thomas RE, Kirpensteijn J, Van Nimwegen SA. Cordless ultrasonic dissector versus advanced bipolar vessel sealing device for laparoscopic ovariectomy in dogs*. Vet Surg. 2017;46:467\u201377.","journal-title":"Vet Surg"},{"key":"715_CR6","first-page":"144","volume":"33","author":"MD \u00c7altekin","year":"2017","unstructured":"\u00c7altekin MD, Aydo\u011fmu\u015f S, Yal\u00e7in SE, Demirel E, Unay FC, \u00d6zbay P\u00d6, et al. Comparison of three different new bipolar energy modalities and classic bipolar in Vivo for tissue thermal spread. Turk Patoloji Derg. 2017;33:144\u20139.","journal-title":"Turk Patoloji Derg"},{"key":"715_CR7","first-page":"290","volume":"52","author":"M \u00d6hlund","year":"2011","unstructured":"\u00d6hlund M, H\u00f6glund O, Olsson U, Lagerstedt A. Laparoscopic ovariectomy in dogs: a comparison of the LigaSure\u2122 and the SonoSurg\u2122 systems. JSAP. 2011;52:290\u20134.","journal-title":"JSAP"},{"key":"715_CR8","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1111\/ajo.13217","volume":"60","author":"C Wong","year":"2020","unstructured":"Wong C, Goh A, Merkur H. Comparison of surgical outcomes using Gyrus PKS\u2122 vs LigaSure\u2122 in total laparoscopic hysterectomy: a randomised controlled trial. Aust N Z J Obstet Gynaecol. 2020;60:790\u20136.","journal-title":"Aust N Z J Obstet Gynaecol"},{"key":"715_CR9","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1111\/j.1447-0756.2007.00533.x","volume":"33","author":"F Demirturk","year":"2007","unstructured":"Demirturk F, Aytan H, Caliskan AC. Comparison of the use of electrothermal bipolar vessel sealer with harmonic scalpel in total laparoscopic hysterectomy. J Obstet Gynaecol Res. 2007;33:341\u20135.","journal-title":"J Obstet Gynaecol Res"},{"key":"715_CR10","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1016\/j.jmig.2014.01.010","volume":"21","author":"H Aytan","year":"2014","unstructured":"Aytan H, Nazik H, Narin R, Api M, Tok EC. Comparison of the use of LigaSure, HALO PKS cutting forceps, and ENSEAL tissue sealer in total laparoscopic hysterectomy: a randomized trial. J Minim Invasive Gynecol. 2014;21:650\u20135.","journal-title":"J Minim Invasive Gynecol"},{"key":"715_CR11","doi-asserted-by":"publisher","DOI":"10.4293\/JSLS.2014.00182","author":"S Bibi","year":"2014","unstructured":"Bibi S, Alblawi S, Velchuru V, Thripuraneni G, Quinteros F, Coralic J, et al. Sealing of vessels larger than 7 millimeters using Enseal in Porcine Aorta. JSLS. 2014. https:\/\/doi.org\/10.4293\/JSLS.2014.00182.","journal-title":"JSLS"},{"key":"715_CR12","doi-asserted-by":"publisher","first-page":"2220","DOI":"10.1111\/jog.14096","volume":"45","author":"B Aykan Yuksel","year":"2019","unstructured":"Aykan Yuksel B, Karadag B, Mulayim B. Comparison of the efficacy and safety of two advanced vessel sealing technologies in total laparoscopic hysterectomy. J Obstet Gynaecol Res. 2019;45:2220\u20137.","journal-title":"J Obstet Gynaecol Res"},{"key":"715_CR13","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1177\/0218492316653683","volume":"24","author":"T Yamada","year":"2016","unstructured":"Yamada T, Sowa T, Bando T, Date H. Experimental study in pulmonary artery sealing with a vessel-sealing device. Asian Cardiovasc Thorac Ann. 2016;24:562\u20137.","journal-title":"Asian Cardiovasc Thorac Ann"},{"key":"715_CR14","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.jmig.2017.10.006","volume":"25","author":"LJ Shiber","year":"2018","unstructured":"Shiber LJ, Ginn DN, Jan A, Gaskins JT, Biscette SM, Pasic R. Comparison of industry-leading energy devices for use in gynecologic laparoscopy: articulating ENSEAL versus ligaSure energy devices. J Minim Invasive Gynecol. 2018;25:467\u201373.","journal-title":"J Minim Invasive Gynecol"},{"key":"715_CR15","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1007\/s00464-007-9619-8","volume":"22","author":"B Person","year":"2008","unstructured":"Person B, Vivas DA, Ruiz D, Talcott M, Coad JE, Wexner SD. Comparison of four energy-based vascular sealing and cutting instruments: a porcine model. Surg Endosc. 2008;22:534\u20138.","journal-title":"Surg Endosc"},{"key":"715_CR16","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1556\/004.2020.00051","volume":"68","author":"MP Dunay","year":"2020","unstructured":"Dunay MP, Lipcsey Z, Arany-T\u00f3th A, N\u00e9meth T, Solymosi N, Venczel L, et al. Experimental assessment of three electrosurgical tissue-sealing devices in a porcine model. Acta Vet Hung. 2020;68:318\u201322.","journal-title":"Acta Vet Hung"},{"key":"715_CR17","first-page":"193","volume":"8","author":"EG Chekan","year":"2015","unstructured":"Chekan EG, Davison MA, Singleton DW, Mennone JZ, Hinoul P. Consistency and sealing of advanced bipolar tissue sealers. Med Devices: Evid Res. 2015;8:193\u20139.","journal-title":"Med Devices: Evid Res"},{"key":"715_CR18","unstructured":"Alexander J. LigaSure Maryland Jaw Thoracic Sealer\/Divider product manual. Product Manual Medtronic. 2020. Available at: https:\/\/www.medtronic.com\/content\/dam\/covidien\/library\/us\/en\/product\/vessel-sealing\/ligasure-maryland-jaw-thoracic-device-product-information-brochure.pdf."},{"key":"715_CR19","unstructured":"Anonymous. Enseal G2 Tissue sealer product manual. Product Manual Ethicon Endo-Surgery. 2011;1\u201388. Available at: https:\/\/www.manualslib.com\/manual\/1985858\/Ethicon-Endo-Surgery-Enseal-G2.html?page=36."},{"key":"715_CR20","first-page":"320","volume":"63","author":"S Nicoli","year":"2022","unstructured":"Nicoli S, Caccamo R. Resection of vaginal septum using endoscopic-guided sealing devices in female dogs: 8 cases (2015\u20132018). JSAP. 2022;63:320\u20134.","journal-title":"JSAP"},{"key":"715_CR21","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1111\/vsu.12948","volume":"47","author":"A Kuvaldina","year":"2018","unstructured":"Kuvaldina A, Hayes G, Sumner J, Behling-Kelly E. Influence of multiple reuse and resterilization cycles on the performance of a bipolar vessel sealing device (LigaSure) intended for single use. Vet Surg. 2018;47:951\u20137.","journal-title":"Vet Surg"},{"key":"715_CR22","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1111\/vsu.12648","volume":"46","author":"JS Blake","year":"2017","unstructured":"Blake JS, Trumpatori BJ, Mathews KG, Griffith EH. Carotid artery bursting pressure and seal time after multiple uses of a vessel sealing device. Vet Surg. 2017;46:501\u20136.","journal-title":"Vet Surg"},{"key":"715_CR23","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0221488","author":"S Gardeweg","year":"2019","unstructured":"Gardeweg S, Bockstahler B, Dupr\u00e8 G. Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices. PLoS ONE. 2019. https:\/\/doi.org\/10.1371\/journal.pone.0221488.","journal-title":"PLoS ONE"},{"key":"715_CR24","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1111\/vsu.13191","volume":"48","author":"D Valenzano","year":"2019","unstructured":"Valenzano D, Hayes G, Gludish D, Weese S. Performance and microbiological safety testing after multiple use cycles and hydrogen peroxide sterilization of a 5-mm vessel\u2010sealing device. Vet Surg. 2019;48:885\u20139.","journal-title":"Vet Surg"},{"key":"715_CR25","doi-asserted-by":"publisher","first-page":"O39","DOI":"10.1111\/vsu.12764","volume":"47","author":"LM Liehmann","year":"2018","unstructured":"Liehmann LM, Seny T, Dupr\u00e9 G. Effect of patient rotation on ovary observation during laparoscopic ovariectomy in dogs. Vet Surg. 2018;47:O39\u2013O51.","journal-title":"Vet Surg"},{"key":"715_CR26","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.jmig.2015.08.493","volume":"22","author":"X Guan","year":"2015","unstructured":"Guan X, Walsh TM, Blazek K, Osial P, Xu D. Articulating enseal to simply single incision hysterectomy with uterosacral ligament suspension. J Minim Invasive Gynecol. 2015;22:143.","journal-title":"J Minim Invasive Gynecol"},{"key":"715_CR27","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.jmig.2015.08.756","volume":"22","author":"PM Osial","year":"2015","unstructured":"Osial PM, Walsh TM, Guan X. Use of the articulating enseal facilitates completion of complex single site laparoscopic surgery. J Minim Invasive Gynecol. 2015;22:212.","journal-title":"J Minim Invasive Gynecol"}],"container-title":["Acta Veterinaria Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13028-023-00715-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13028-023-00715-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13028-023-00715-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T17:02:38Z","timestamp":1705424558000},"score":1,"resource":{"primary":{"URL":"https:\/\/actavetscand.biomedcentral.com\/articles\/10.1186\/s13028-023-00715-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,29]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["715"],"URL":"https:\/\/doi.org\/10.1186\/s13028-023-00715-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3227104\/v1","asserted-by":"object"}]},"ISSN":["1751-0147"],"issn-type":[{"value":"1751-0147","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,29]]},"assertion":[{"value":"2 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study did not require official approval on animal experimentation according to national legislation because it concerned routine elective surgery on patients using high-end commercially available instruments intended for this use. The study has received mandatory ethical approval by the Ethical committee of the department of Clinical Sciences of the Faculty of Veterinary Medicine, Utrecht University, under the number: AVR 20\u2009\u2212\u200901. The animals were handled according to high ethical standards and national legislation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Utrecht University and the department of clinical sciences of companion animals sign an agreement form (Consent form) with every client prior to treatment at the university hospital. In this agreement, the owner signs to a range of terms, but also to the use of medical information for publication as long as the welfare of the animal is not compromised and the identity of the client and the animal is protected. Above this, all owners signed a consent form related to the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Data included in this article have previously been published in Veterinary Surgery Volume 51, Issue S1: O12-O24 (Abstracts of 2022 Veterinary Endoscopy Society Annual Conference New York, United States of America, June 1\u20133, 2022).","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Prior publication"}},{"value":"The authors declare that they have no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"51"}}