{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T10:35:07Z","timestamp":1765190107245,"version":"3.46.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T00:00:00Z","timestamp":1765152000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T00:00:00Z","timestamp":1765152000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007797","name":"University of Helsinki","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007797","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Vet Scand"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Both invasive and non-invasive blood pressure measuring methods are used in clinical and experimental work in veterinary medicine and several studies validating these methods are published. The aim of this study was to assess the level of agreement between non-invasive and invasive arterial blood pressure measurements within a wide range of blood pressures in sheep. Six adult Texel-cross female sheep were included. Anaesthesia was induced with IV propofol (4\u20138\u00a0mg\/kg) and maintained with sevoflurane in 50% oxygen and air. Blood pressure measurements were simultaneously obtained using both invasive methods (electronic pressure transducer (EPT) connected to the auricular and carotid arteries, and aneroid manometer connected to the auricular artery) and non-invasive methods (the oscillometric device (OD) and Doppler). Carotid artery EPT was considered the \u2018gold standard\u2019 to which other methods were compared. The agreement between the two methods was evaluated with the Bland-Altman method, in conditions of normotension, hypertension (MAP\u2009&gt;\u2009160 mmHg, induced with phenylephrine), and hypotension (MAP\u2009&lt;\u200950 mmHg, induced with acepromazine). The devices were evaluated using the American College of Veterinary Internal Medicine guidelines.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Carotid MAP values ranged from 37 to 192 mmHg. Mean bias and limits of agreement were \u2212\u20092.8 mmHg and \u2212\u200911\u20135.4 mmHg for the auricular EPT MAP; 5.1 mmHg and \u2212\u200912.2\u201322.3 mmHg for the aneroid manometer MAP; \u2212 2.7 mmHg and \u2212\u200923.9\u201318.6 mmHg for the OD MAP; \u2212\u20091.5 mmHg and \u2212\u200920.1\u201323.2 mmHg for the Doppler SAP; respectively. Correlation coefficients for all methods were &gt;\u20090.95.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Doppler SAP and OD MAP demonstrated acceptable accuracy over a broad blood pressure range, supporting their utility for sheep as surrogate of invasive methods of measuring blood pressure. Auricular EPT was the best surrogate of central arterial pressure to be used in clinical conditions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13028-025-00833-6","type":"journal-article","created":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T10:33:17Z","timestamp":1765189997000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Agreement between arterial blood pressures measured non-invasively and invasively in anaesthetised sheep"],"prefix":"10.1186","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-3123-5965","authenticated-orcid":false,"given":"Sanna Kaisa","family":"Sainmaa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magdy Adam Hussein","family":"Adam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela C.","family":"Casoni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Vilhelmiina","family":"Huuskonen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Valldeoriola","family":"Card\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marja Riitta","family":"Raekallio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Kristina","family":"Mykk\u00e4nen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,8]]},"reference":[{"key":"833_CR1","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s11259-006-0071-3","volume":"30","author":"F Valerio","year":"2006","unstructured":"Valerio F, Mariscoli M, Petrizzi L. Comparative evaluation of the accuracy of oscillometric and direct methods for arterial blood pressure monitoring during anaesthesia in dogs. Vet Res Comm. 2006;30:321\u20133.","journal-title":"Vet Res Comm"},{"key":"833_CR2","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1111\/j.1476-4431.2010.00536.x","volume":"20","author":"A Shih","year":"2010","unstructured":"Shih A, Robertson S, Vigani A, Pablo L, Bandt C. Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs. J Vet Emerg Crit Care. 2010;20:313\u20138.","journal-title":"J Vet Emerg Crit Care"},{"key":"833_CR3","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/s13620-020-00164-0","volume":"73","author":"LG Fern\u00e1ndez","year":"2020","unstructured":"Fern\u00e1ndez LG, Niimura del Barrio MC, Loughran C. Use of adrenaline continuous infusion to treat hypotension during general anaesthesia in a cow and a calf. Ir Vet J. 2020;73:13.","journal-title":"Ir Vet J"},{"key":"833_CR4","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.vaa.2019.10.011","volume":"47","author":"J Einwaller","year":"2020","unstructured":"Einwaller J, Painer J, Raekallio M, Gasch K, Restitutti F, Auer U, et al. Cardiovascular effects of intravenous Vatinoxan (MK-467) in medetomidine-tiletamine-zolazepam anaesthetised red deer (Cervus elaphus). Vet Anaesth Analg. 2020;47:518\u201327.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR5","doi-asserted-by":"publisher","first-page":"188","DOI":"10.7589\/JWD-D-20-00229","volume":"58","author":"H Rauch","year":"2022","unstructured":"Rauch H, Pohlin F, Einwaller J, Habe M, Painer J, Stalder G. Comparison of the cardiovascular effects of two Medetomidine doses combined with tiletamine-zolazepam for the immobilization of red deer Hinds (Cervus elaphus). J Wildl Dis. 2022;58:188\u201393.","journal-title":"J Wildl Dis"},{"key":"833_CR6","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1638\/2014-0034R.1","volume":"46","author":"J Siegal-Willott","year":"2015","unstructured":"Siegal-Willott J, Citino SB, Wade S, Elder L, Hayek LC, Lance WR. Butorphanol, azaperone, and Medetomidine anesthesia in free-ranging white-tailed deer (Odocoileus virginianus) using radiotransmitter darts. J Zoo Wildl Med. 2015;46:291\u201397.","journal-title":"J Zoo Wildl Med"},{"key":"833_CR7","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1638\/2018-0030","volume":"50","author":"S Sainmaa","year":"2019","unstructured":"Sainmaa S, Mykk\u00e4nen A, Adam M, Jantunen N, Vainio O, Raekallio M. Intravenous Vatinoxan in Markhors (Capra Falconeri heptneri) immobilized with intramuscular Medetomidine and ketamine \u2014 a preliminary dose screening study. J Zoo Wildl Med. 2019;50:159\u201366.","journal-title":"J Zoo Wildl Med"},{"key":"833_CR8","doi-asserted-by":"publisher","DOI":"10.3389\/fvets.2021.740614","author":"J Meuffels","year":"2021","unstructured":"Meuffels J, Lueders I, Bertschinger H. Cardiopulmonary parameters and arterial blood gases during etorphine-medetomidine-midazolam immobilization in free-ranging black rhinoceroses (Diceros bicornis) undergoing electro-ejaculation\u2014A preliminary study. Front Vet Sci. 2021. https:\/\/doi.org\/10.3389\/fvets.2021.740614.","journal-title":"Front Vet Sci"},{"key":"833_CR9","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1002\/9781119830306.ch12","volume-title":"Veterinary anaesthesia and analgesia: the sixth edition of Lumb and Jones","author":"O Odette","year":"2024","unstructured":"Odette O. Blood pressure monitoring. In: Lamont LA, Grimm KA, Robertson S, et al. editors. Veterinary anaesthesia and analgesia: the sixth edition of Lumb and Jones. 6th ed. Singapore: Wiley-Blackwell; 2024. pp. 197\u2013209.","edition":"6"},{"key":"833_CR10","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1038\/s41371-022-00693-x","volume":"37","author":"JE Sharman","year":"2023","unstructured":"Sharman JE, Tan I, Stergiou GS. Automated \u2018oscillometric\u2019 blood pressure measuring devices: how they work and what they measure. J Hum Hypertens. 2023;37:93\u2013100.","journal-title":"J Hum Hypertens"},{"key":"833_CR11","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.rvsc.2014.05.003","volume":"97","author":"C Vachon","year":"2014","unstructured":"Vachon C, Belanger MC, Burns PM. Evaluation of oscillometric and doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs. Res Vet Sci. 2014;97:111\u20137.","journal-title":"Res Vet Sci"},{"key":"833_CR12","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1111\/vec.12161","volume":"24","author":"AF da Cunha","year":"2014","unstructured":"da Cunha AF, Saile K, Beaufr\u00e8re H, Wolfson W, Seaton D, Acierno MJ. Measuring level of agreement between values obtained by directly measured blood pressure and ultrasonic doppler flow detector in cats. J Vet Emerg Crit Care. 2014;24:272\u20138.","journal-title":"J Vet Emerg Crit Care"},{"key":"833_CR13","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.vaa.2019.11.001","volume":"47","author":"SA Cerejo","year":"2020","unstructured":"Cerejo SA, Teixeira-Neto FJ, Garofalo NA, Pimenta EL, Zanuzzo FS, Klein AV. Effects of cuff size and position on the agreement between arterial blood pressure measured by doppler ultrasound and through a dorsal pedal artery catheter in anesthetized cats. Vet Anaesth Analg. 2020;47:191\u20139.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR14","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/vaa.12131","volume":"41","author":"LS Barter","year":"2014","unstructured":"Barter LS, Epstein SE. Comparison of Doppler, oscillometric, auricular and carotid arterial blood pressure measurements in isoflurane anesthetized new Zealand white rabbits. Vet Anaesth Analg. 2014;41:393\u20137.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR15","first-page":"244","volume":"82","author":"O Szalu\u015b-Jordanow","year":"2018","unstructured":"Szalu\u015b-Jordanow O, Czopowicz M, \u015awierk A, Szpinda O, Garncarz M, Mickiewicz M, et al. Oscillometric and doppler arterial blood pressure measurement in conscious goats. Can J Vet Res. 2018;82:244\u20138.","journal-title":"Can J Vet Res"},{"key":"833_CR16","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1111\/j.1467-2995.2011.00685.x","volume":"39","author":"L Harvey","year":"2012","unstructured":"Harvey L, Knowles T, Murison PJ. Comparison of direct and doppler arterial blood pressure measurements in rabbits during isoflurane anaesthesia. Vet Anaesth Analg. 2012;39:174\u201384.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR17","doi-asserted-by":"publisher","first-page":"300","DOI":"10.5326\/JAAHA-MS-6163","volume":"51","author":"MJ Kennedy","year":"2015","unstructured":"Kennedy MJ, Michele B. Agreement between doppler and invasive blood pressure monitoring in anesthetized dogs weighing\u2009<\u20095 kg. Am Anim Hosp Assoc. 2015;51:300\u20135.","journal-title":"Am Anim Hosp Assoc"},{"key":"833_CR18","doi-asserted-by":"crossref","first-page":"468","DOI":"10.7589\/0090-3558-45.2.468","volume":"45","author":"R Lapid","year":"2009","unstructured":"Lapid R, Shilo-Benjamini Y. Immobilization of captive Nubian Ibex (Capra nubiana) with butorphanol-midazolam-medetomidine or butorphanol-azaperone-medetomidine and Atipamezole reversal. J Wildl Dis. 2009;45:468\u201380.","journal-title":"J Wildl Dis"},{"key":"833_CR19","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1111\/j.1939-1676.2007.tb03005.x","volume":"21","author":"SA Brown","year":"2007","unstructured":"Brown SA, Atkins C, Bagley R, Carr A, Cowgill L, Davidson M, et al. Guidelines for the identification, evaluation and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2007;21:542\u201358.","journal-title":"J Vet Intern Med"},{"key":"833_CR20","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1111\/vaa.12018","volume":"40","author":"CM Trim","year":"2013","unstructured":"Trim CM, Hofmeister EH, Peroni JF, Thoresen M, et al. Evaluation of an oscillometric blood pressure monitor for use in anesthetized sheep. Vet Anaesth Analg. 2013;40:31\u20139.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR21","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1016\/j.rvsc.2014.10.004","volume":"97","author":"D Almeida","year":"2014","unstructured":"Almeida D, Barletta M, Mathews L, Graham L, Quandt J. Comparison between invasive blood pressure and a non-invasive blood pressure monitor in anesthetized sheep. Res Vet Sci. 2014;97:582\u201386.","journal-title":"Res Vet Sci"},{"key":"833_CR22","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1024\/0036-7281.151.6.275","volume":"151","author":"M Mosing","year":"2009","unstructured":"Mosing M, Franz S, Iff I, Schwendenwein I, et al. Invasive Arterielle Blutdruckmessung mittels eines aneroiden systems beim rind. Schweiz Arch Tierheilkd. 2009;151:275\u201380.","journal-title":"Schweiz Arch Tierheilkd"},{"key":"833_CR23","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1111\/j.1532-950X.1985.tb00900.x","volume":"14","author":"TW Riebold","year":"1985","unstructured":"Riebold TW, Evans AT. Blood pressure measurements in the anesthetized horse: comparison of four methods. Vet Surg. 1985;14:332\u20137.","journal-title":"Vet Surg"},{"key":"833_CR24","doi-asserted-by":"publisher","first-page":"921","DOI":"10.2460\/ajvr.79.9.921","volume":"79","author":"M Adam","year":"2018","unstructured":"Adam M, Raekallio MR, Salla KM, Honkavaara JM, M\u00e4nnikk\u00f6 S, Scheinin M, et al. Effects of the peripherally acting \u03b12-adrenoceptor antagonist MK-467 on cardiopulmonary function in sheep sedated by intramuscular administration of Medetomidine and ketamine and reversed by intramuscular administration of Atipamezole. Am J Vet Res. 2018;79:921\u201332.","journal-title":"Am J Vet Res"},{"key":"833_CR25","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571\u201382.","journal-title":"J Biopharm Stat"},{"key":"833_CR26","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1097\/OPX.0000000000001465","volume":"97","author":"A Carkeet","year":"2020","unstructured":"Carkeet A. A review of the use of confidence intervals for Bland-Altman limits of agreement in optometry and vision science. Optom Vis Sci. 2020;97:3\u20138.","journal-title":"Optom Vis Sci"},{"key":"833_CR27","doi-asserted-by":"publisher","first-page":"33","DOI":"10.21836\/PEM20150105","volume":"31","author":"TC Gent","year":"2015","unstructured":"Gent TC, Schwarz A, Hatz LA, Gozalo-Marcilla M, Schauvliege S, Gasthuys F, et al. Evaluation of accuracy of invasive and non-invasive blood pressure monitoring in relation to carotid artery pressure in anaesthetized ponies. Pferdeheilkunde. 2015;31:33\u20138.","journal-title":"Pferdeheilkunde"},{"key":"833_CR28","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.vaa.2018.02.006","volume":"45","author":"KAT Wilson","year":"2018","unstructured":"Wilson KAT, Raisis AL, Drynan EA, Mosing M, Lester GD, Hayman J, et al. Agreement between invasive blood pressure measured centrally and peripherally in anesthetized horses. Vet Anaesth Analg. 2018;45:467\u201376.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR29","first-page":"171","volume-title":"Guyton and hall textbook of medical physiology","author":"JE Hall","year":"2021","unstructured":"Hall JE, Hall ME. Overview of the circulation: pressure, flow, and resistance. In: Hall JE, Hall ME, editors. Guyton and hall textbook of medical physiology. Philadelphia: Elsevier; 2021. pp. 171\u201381."},{"key":"833_CR30","first-page":"211","volume":"70","author":"CE Haberman","year":"2006","unstructured":"Haberman CE, Kang CW, Morgan JD, Brown SA. Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure Estimation in conscious dogs. Can J Vet Res. 2006;70:211\u20137.","journal-title":"Can J Vet Res"},{"key":"833_CR31","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1111\/j.1476-4431.2010.00520.x","volume":"20","author":"AP Bosiack","year":"2010","unstructured":"Bosiack AP, Mann FA, Dodam JR, Wagner-Mann CC, Branson KR. Comparison of ultrasonic doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs. J Vet Emerg Crit Care. 2010;20:207\u201315.","journal-title":"J Vet Emerg Crit Care"},{"key":"833_CR32","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1111\/vaa.12101","volume":"41","author":"TK Aarnes","year":"2014","unstructured":"Aarnes TK, Hubbell JAE, Lerche P, Bednarski RM. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized sheep, goats, and cattle. Vet Anaesth Analg. 2014;41:174\u201385.","journal-title":"Vet Anaesth Analg"},{"key":"833_CR33","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.rvsc.2020.07.004","volume":"132","author":"J Izer","year":"2020","unstructured":"Izer J, Wilson R. Comparison of invasive and non-invasive blood pressure measurements in anesthetized female Dorset cross-bred lambs (Ovis aries). Res Vet Sci. 2020;132:257\u201361.","journal-title":"Res Vet Sci"},{"key":"833_CR34","doi-asserted-by":"publisher","first-page":"141","DOI":"10.11613\/BM.2015.015","volume":"25","author":"D Giavarina","year":"2015","unstructured":"Giavarina D. Understanding Bland Altman analysis. Biochem Med. 2015;25:141\u201351.","journal-title":"Biochem Med"}],"container-title":["Acta Veterinaria Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13028-025-00833-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13028-025-00833-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13028-025-00833-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T10:33:18Z","timestamp":1765189998000},"score":1,"resource":{"primary":{"URL":"https:\/\/actavetscand.biomedcentral.com\/articles\/10.1186\/s13028-025-00833-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,8]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["833"],"URL":"https:\/\/doi.org\/10.1186\/s13028-025-00833-6","relation":{},"ISSN":["1751-0147"],"issn-type":[{"value":"1751-0147","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,8]]},"assertion":[{"value":"19 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Finnish Animal Experiment Board (ESAVI\/9394\/04.10.07\/2015).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"54"}}