{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T04:08:45Z","timestamp":1776139725936,"version":"3.50.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Manipal Academy of Higher Education, Manipal"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Patient Saf Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Despite the critical role of central airway dimensions in clinical practice, comprehensive normative data remain scarce globally, particularly for diverse ethnic populations. This study aims to establish the first high-resolution computed tomography (HRCT) based reference values for tracheobronchial anatomy in Indian adults, addressing a significant gap in precision medicine.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This retrospective cross-sectional study was conducted at Kasturba Hospital, Manipal, India. HRCT chest scans performed between January 1, 2021, and March 31, 2024, were screened, and 503 adults (277 males, 226 females; aged 20\u201380 years) with normal findings were included. Primary outcomes were normative tracheal and bronchial dimensions (lengths, diameters, cross-sectional areas). Secondary outcomes included age and gender-based variations, correlations with demographics, and predictive models for airway device selection. Inclusion criteria were HRCT scans with normal thoracic findings and adequate inspiratory effort. Exclusion criteria included thoracic, pulmonary or cardiac abnormalities, prior airway surgery, presence of airway devices, or severe imaging artifacts. Data were analysed using t-test, one-way ANOVA, Pearson correlations, and multiple linear regression. Statistical significance was set at <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Indian males exhibited significantly larger airways than females (tracheal length: 109.5\u2009\u00b1\u20098.9\u00a0mm vs. 100.5\u2009\u00b1\u20097.4\u00a0mm, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001; distal tracheal area: 311.3\u2009\u00b1\u2009111.1\u00a0mm\u00b2 vs. 227.6\u2009\u00b1\u200992.9\u00a0mm\u00b2, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Notably, 54.5% of subjects had a more vertical left bronchus, contradicting classical anatomical dogma. High rates of short right main bronchi (&lt;\u200923\u00a0mm) were observed in 49.5% of subjects, increasing the risk of double-lumen endobronchial tube misplacement. The distal tracheal diameter was strongly correlated with bronchial dimensions (<jats:italic>r<\/jats:italic>\u2009=\u20090.621, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), providing evidence-based device selection.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>This study provides the first population-specific normative data for central airway dimensions in Indian adults, revealing profound ethnic variations with immediate clinical implications for airway management, thoracic surgery, and personalised medical device design. The findings underscore the necessity of region-specific reference standards to optimise patient safety and highlight the influence of ethnicity on airway anatomy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s13037-025-00450-2","type":"journal-article","created":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T09:56:50Z","timestamp":1759312610000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Anatomic reference measures for central airway anatomy in Indian adults: implications for precision airway management in surgical patient safety"],"prefix":"10.1186","volume":"19","author":[{"given":"Purnima","family":"Adhikari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chandni","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koteshwara","family":"Prakashini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rahul","family":"Magazine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohan K","family":"Manu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santa Kumar","family":"Das","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sharma","family":"Paudel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,1]]},"reference":[{"key":"450_CR1","doi-asserted-by":"publisher","unstructured":"Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, Brown RH. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol [Internet]. 2017;123:876\u201383. Available from: http:\/\/wwwhttps:\/\/doi.org\/10.1152\/japplphysiol.00307.2017","DOI":"10.1152\/japplphysiol.00307.2017"},{"key":"450_CR2","doi-asserted-by":"publisher","unstructured":"Hannallah M, Benumof JL, Silverman PM, Kelly LC, Lea D. Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter. J Cardiothorac Vasc Anesth [Internet]. 1997;11(2):168\u201371. Available from: https:\/\/doi.org\/10.1016\/S1053-0770(97)90208-1","DOI":"10.1016\/S1053-0770(97)90208-1"},{"key":"450_CR3","doi-asserted-by":"publisher","unstructured":"Chow MYH, Liam BL, Thng CH, Chong BK. Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter. Anesth Analg [Internet]. 1999;88(2). Available from: https:\/\/journals.lww.com\/anesthesia-analgesia\/fulltext\/1999\/02000\/predicting_the_size_of_a_double_lumen.14.aspx.https:\/\/doi.org\/10.1097\/00000539-199902000-00014","DOI":"10.1097\/00000539-199902000-00014"},{"key":"450_CR4","doi-asserted-by":"publisher","unstructured":"Hautmann H, Gamarra F, Henke M, Diehm S, Huber RM. High frequency jet ventilation in interventional fiberoptic bronchoscopy. Anesth Analg [Internet]. 2000;90(6).Available from: https:\/\/journals.lww.com\/anesthesia-analgesia\/fulltext\/2000\/06000\/high_frequency_jet_ventilation_in_interventional.34.aspx.https:\/\/doi.org\/10.1097\/00000539-200006000-00034","DOI":"10.1097\/00000539-200006000-00034"},{"key":"450_CR5","unstructured":"Singh-Radcliff N. 5-Minute anesthesia consult. Lippincott Williams & Wilkins; 2012."},{"issue":"3","key":"450_CR6","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1177\/0003489415608867","volume":"125","author":"AT Hillel","year":"2016","unstructured":"Hillel AT, Karatayli-Ozgursoy S, Samad I, Best SRA, Pandian V, Giraldez L, et al. Predictors of posterior glottic stenosis: A multi-institutional case-control study. Annals Otology Rhinology Laryngology. 2016;125(3):257\u201363. https:\/\/doi.org\/10.1177\/0003489415608867.","journal-title":"Annals Otology Rhinology Laryngology"},{"key":"450_CR7","doi-asserted-by":"publisher","unstructured":"Mahajan S, Mahajan A, Lalit M, Verma P. Morphometry of adult human trachea and its clinical implications: A cadaveric study in Northern india. J Clin Diagn Res. 2022;16(7). https:\/\/doi.org\/10.7860\/JCDR\/2022\/55145.16574","DOI":"10.7860\/JCDR\/2022\/55145.16574"},{"issue":"1","key":"450_CR8","doi-asserted-by":"publisher","first-page":"7","DOI":"10.11637\/aba.2017.30.1.7","volume":"30","author":"IS Kim","year":"2017","unstructured":"Kim IS, Song CH. The morphometric study of main bronchus in Korean cadaver. Korean J Phys Anthropol. 2017;30(1):7. https:\/\/doi.org\/10.11637\/aba.2017.30.1.7.","journal-title":"Korean J Phys Anthropol"},{"key":"450_CR9","doi-asserted-by":"publisher","unstructured":"Mi W, Zhang C, Wang H, Cao J, Li C, Yang L, et al. Measurement and analysis of the tracheobronchial tree in Chinese population using computed tomography. PLoS ONE. 2015;10(4). https:\/\/doi.org\/10.1371\/journal.pone.0123177.","DOI":"10.1371\/journal.pone.0123177"},{"issue":"10","key":"450_CR10","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1111\/pan.13210","volume":"27","author":"P Szelloe","year":"2017","unstructured":"Szelloe P, Weiss M, Schraner T, Dave MH. Lower airway dimensions in pediatric patients\u2014A computed tomography study. Paediatr Anaesth. 2017;27(10):1043\u20139. https:\/\/doi.org\/10.1111\/pan.13210.","journal-title":"Paediatr Anaesth"},{"issue":"9","key":"450_CR11","doi-asserted-by":"publisher","first-page":"2940","DOI":"10.1002\/ppul.25536","volume":"56","author":"UK Chalwadi","year":"2021","unstructured":"Chalwadi UK, Swamy N, Agarwal A, Gauss CH, Greenberg SB, Lyons KA. Determining normal values for lower trachea and bronchi size in children by computed tomography (CT). Pediatr Pulmonol. 2021;56(9):2940\u20138. https:\/\/doi.org\/10.1002\/ppul.25536.","journal-title":"Pediatr Pulmonol"},{"issue":"2","key":"450_CR12","doi-asserted-by":"publisher","first-page":"423","DOI":"10.2214\/AJR.17.18597","volume":"210","author":"W Kuo","year":"2018","unstructured":"Kuo W, Ciet P, Andrinopoulou ER, Chen Y, Pullens B, Garcia-Pe\u00f1a P, et al. Reference values for central airway dimensions on CT images of children and adolescents. Am J Roentgenol. 2018;210(2):423\u201330. https:\/\/doi.org\/10.2214\/AJR.17.18597.","journal-title":"Am J Roentgenol"},{"key":"450_CR13","doi-asserted-by":"publisher","unstructured":"Premakumar Y, Griffin MF, Szarko M. Morphometric characterisation of human tracheas: focus on cartilaginous ring variation. BMC Res Notes. 2018;11(1). https:\/\/doi.org\/10.1186\/s13104-018-3123-1.","DOI":"10.1186\/s13104-018-3123-1"},{"key":"450_CR14","doi-asserted-by":"publisher","unstructured":"Liu Z, Liu M, Zhao L, Qi X, yu Y, Liang S, et al. Comparison of the accuracy of three methods measured the length of the right main stem bronchus by chest computed tomography as a guide to the use of right sided double-lumen tube. BMC Anesthesiol. 2022;22(1). https:\/\/doi.org\/10.1186\/s12871-022-01744-z.","DOI":"10.1186\/s12871-022-01744-z"},{"issue":"5","key":"450_CR15","doi-asserted-by":"publisher","first-page":"488","DOI":"10.4103\/0019-5049.89880","volume":"55","author":"M Varshney","year":"2011","unstructured":"Varshney M, Sharma K, Kumar R, Varshney PG. Appropriate depth of placement of oral endotracheal tube and its possible determinants in Indian adult patients. Indian J Anaesth. 2011;55(5):488\u201393. https:\/\/doi.org\/10.4103\/0019-5049.89880.","journal-title":"Indian J Anaesth"},{"issue":"11","key":"450_CR16","doi-asserted-by":"publisher","first-page":"4276","DOI":"10.21037\/jtd-22-595","volume":"14","author":"S Matsuoka","year":"2022","unstructured":"Matsuoka S, Shimizu K, Koike S, Takeda T, Miura K, Eguchi T, et al. Significance of the evaluation of tracheal length using a three-dimensional imaging workstation. J Thorac Dis. 2022;14(11):4276\u201384. https:\/\/doi.org\/10.21037\/jtd-22-595.","journal-title":"J Thorac Dis"},{"key":"450_CR17","first-page":"27","volume":"112","author":"H Jit","year":"2000","unstructured":"Jit H, Jit I. Dimensions & shape of the trachea in the neonates, children & adults in Northwest India. Indian J Med Res. 2000;112:27.","journal-title":"Indian J Med Res"},{"issue":"1","key":"450_CR18","doi-asserted-by":"publisher","first-page":"36","DOI":"10.17511\/ijmrr.2019.i01.07","volume":"7","author":"DD Datta","year":"2019","unstructured":"Datta DD, Kundu DD, ProfDrS P, Das DrA. A morphometric study of adult human trachea in West Bengal population. Int J Med Res Rev. 2019;7(1):36\u201342. https:\/\/doi.org\/10.17511\/ijmrr.2019.i01.07.","journal-title":"Int J Med Res Rev"},{"key":"450_CR19","doi-asserted-by":"publisher","unstructured":"Chen Y, Guo Y, Mi W, Zhang C, Wang H, Zhao D, et al. Anatomy of the right upper lobe revisited and clinical considerations in Chinese population. PLoS ONE. 2020;15(11 November). https:\/\/doi.org\/10.1371\/journal.pone.0242178.","DOI":"10.1371\/journal.pone.0242178"},{"issue":"7","key":"450_CR20","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1111\/anae.12208","volume":"68","author":"JH Kim","year":"2013","unstructured":"Kim JH, Park SH, Han SH, Nahm FS, Jung CK, Kim KM. The distance between the carina and the distal margin of the right upper lobe orifice measured by computerised tomography as a guide to right-sided double\u2010lumen endobronchial tube use. Anaesthesia. 2013;68(7):700\u20135. https:\/\/doi.org\/10.1111\/anae.12208.","journal-title":"Anaesthesia"},{"issue":"7","key":"450_CR21","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1007\/s12630-019-01342-7","volume":"66","author":"JS Bussi\u00e8res","year":"2019","unstructured":"Bussi\u00e8res JS, Gingras M, Perron L, Somma J, Frenette M, Couture EJ, et al. Right upper lobe anatomy revisited: a computed tomography scan study. Can J Anesth. 2019;66(7):813\u20139. https:\/\/doi.org\/10.1007\/s12630-019-01342-7.","journal-title":"Can J Anesth"},{"issue":"8","key":"450_CR22","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1007\/BF03022798","volume":"53","author":"DT Wong","year":"2006","unstructured":"Wong DT, Kumar A. Case report: endotracheal tube malposition in a patient with a tracheal bronchus. Can J Anesth. 2006;53(8):810. https:\/\/doi.org\/10.1007\/BF03022798.","journal-title":"Can J Anesth"},{"issue":"5","key":"450_CR23","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1097\/00000542-198711000-00018","volume":"67","author":"JL Benumof","year":"1987","unstructured":"Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology. 1987;67(5):729\u201338. https:\/\/doi.org\/10.1097\/00000542-198711000-00018.","journal-title":"Anesthesiology"},{"key":"450_CR24","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1097\/ALN.0b013e31818344bd","volume":"109","author":"S Hagihira","year":"2008","unstructured":"Hagihira S, Mashimo T, Takashina M. Application of a newly designed right-sided, double-lumen endobronchial tube in patients with a very short right mainstem bronchus. Anesthesiology. 2008;109:565\u20138. https:\/\/doi.org\/10.1097\/ALN.0b013e31818344bd.","journal-title":"Anesthesiology"},{"issue":"4","key":"450_CR25","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1053\/j.jvca.2013.05.029","volume":"28","author":"D Kim","year":"2014","unstructured":"Kim D, Son JS, Ko S, Jeong W, Lim H. Measurements of the length and diameter of main bronchi on three-dimensional images in Asian adult patients in comparison with the height of patients. J Cardiothorac Vasc Anesth. 2014;28(4):890\u20135. https:\/\/doi.org\/10.1053\/j.jvca.2013.05.029.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"450_CR26","doi-asserted-by":"publisher","unstructured":"Shah SB, Hariharan U, Chawla R. Choosing the correct-sized adult double-lumen tube: quest for the holy Grail. Annals of Cardiac Anaesthesia. 2023;26:124\u201332. https:\/\/doi.org\/10.4103\/aca.aca_140_22","DOI":"10.4103\/aca.aca_140_22"},{"key":"450_CR27","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/j.anclin.2012.08.001","volume":"30","author":"A Pedoto","year":"2012","unstructured":"Pedoto A. How to choose the Double-Lumen tube size and side. The eternal debate. Anesthesiol Clin. 2012;30:671\u201381. https:\/\/doi.org\/10.1016\/j.anclin.2012.08.001.","journal-title":"Anesthesiol Clin"},{"issue":"2","key":"450_CR28","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/S1053-0770(05)80179-X","volume":"9","author":"P Slinger","year":"1995","unstructured":"Slinger P. Choosing the appropriate double-lumen tube: a glimmer of science comes to a dark Art. J Cardiothorac Vasc Anesth. 1995;9(2):117\u20138. https:\/\/doi.org\/10.1016\/S1053-0770(05)80179-X.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"450_CR29","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1002\/lary.21752","volume":"121","author":"A Coordes","year":"2011","unstructured":"Coordes A, Rademacher G, Knopke S, Todt I, Ernst A, Estel B, et al. Selection and placement of oral ventilation tubes based on tracheal morphometry. Laryngoscope. 2011;121(6):1225\u201330. https:\/\/doi.org\/10.1002\/lary.21752.","journal-title":"Laryngoscope"},{"key":"450_CR30","unstructured":"Ulusoy M, Uysal II, Kivrak AS, Ozbek S, Karabulut AK, Paksoy Y et al. Age and gender related changes in bronchial tree: a morphometric study with multidedector CT. Eur Rev Med Pharmacol Sci. 2016;20(16)."},{"key":"450_CR31","doi-asserted-by":"publisher","unstructured":"Tai A, Corke C, Joynt GM, Griffith J, Lunn D, Tong PWY. A comparative study of tracheal diameter in Caucasian and Chinese patients. Anaesth Intensive Care. 2016;44. https:\/\/doi.org\/10.1177\/0310057X1604400603.","DOI":"10.1177\/0310057X1604400603"},{"key":"450_CR32","doi-asserted-by":"publisher","unstructured":"Karmali S, Rose P. Tracheal tube size in adults undergoing elective surgery \u2013 a narrative review. Anaesthesia. 2020;75:1529\u201339. https:\/\/doi.org\/10.1111\/anae.15041","DOI":"10.1111\/anae.15041"},{"issue":"3","key":"450_CR33","doi-asserted-by":"publisher","first-page":"189","DOI":"10.4097\/kjae.2014.66.3.189","volume":"66","author":"JW Lee","year":"2014","unstructured":"Lee JW, Son JS, Choi JW, Han YJ, Lee JR. The comparison of the lengths and diameters of main bronchi measured from two-dimensional and three-dimensional images in the same patients. Korean J Anesthesiol. 2014;66(3):189\u201394. https:\/\/doi.org\/10.4097\/kjae.2014.66.3.189.","journal-title":"Korean J Anesthesiol"},{"key":"450_CR34","doi-asserted-by":"publisher","unstructured":"Sakai H, Nakano Y, Muro S, Hirai T, Takubo Y, Oku Y, et al. Age-related changes in the trachea in healthy adults. Oxygen transport to tissue XXXI. Springer; 2010. pp. 115\u201320. https:\/\/doi.org\/10.1007\/978-1-4419-1241-1_16.","DOI":"10.1007\/978-1-4419-1241-1_16"},{"key":"450_CR35","unstructured":"Brodsky JB, Macario A, Mark JBD. Tracheal diameter predicts Double-lumen tube size: A method for selecting left double-lumen tubes."},{"issue":"1","key":"450_CR36","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3126\/jiom.v41i1.28587","volume":"41","author":"A Shrestha","year":"2019","unstructured":"Shrestha A, Ranjit N, Bhandari R, Adhikari B, Gautam J. Measurement of subcarinal angle: A cadaveric study. J Inst Med Nepal. 2019;41(1):20\u20133. https:\/\/doi.org\/10.3126\/jiom.v41i1.28587.","journal-title":"J Inst Med Nepal"},{"issue":"933","key":"450_CR37","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1259\/bjr\/75107416","volume":"78","author":"N Karabulut","year":"2005","unstructured":"Karabulut N. CT assessment of tracheal carinal angle and its determinants. Br J Radiol. 2005;78(933):787\u201390. https:\/\/doi.org\/10.1259\/bjr\/75107416.","journal-title":"Br J Radiol"},{"key":"450_CR38","unstructured":"Standring S. Gray\u2019s anatomy: the anatomical basis of clinical practice, expert consult. Aubrey Durkin; 2009."}],"container-title":["Patient Safety in Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-025-00450-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13037-025-00450-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-025-00450-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T09:56:53Z","timestamp":1759312613000},"score":1,"resource":{"primary":{"URL":"https:\/\/pssjournal.biomedcentral.com\/articles\/10.1186\/s13037-025-00450-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,1]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["450"],"URL":"https:\/\/doi.org\/10.1186\/s13037-025-00450-2","relation":{},"ISSN":["1754-9493"],"issn-type":[{"value":"1754-9493","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,1]]},"assertion":[{"value":"16 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study followed the Helsinki Declaration Principles. The institutional Ethics Committee of Kasturba Medical College and Kasturba Hospital, Manipal, approved the study (numbered IEC1: 282\/2024).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Not Applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"While preparing this work, the authors utilised ChatGPT and Grammarly AI tools to enhance grammar and readability. After using this tool, the authors reviewed and edited the content as needed and took full responsibility for the content of the published article.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration of generative AI and AI-assisted technologies"}},{"value":"The authors declare no competing interests.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"26"}}