{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T21:29:52Z","timestamp":1775338192257,"version":"3.50.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T00:00:00Z","timestamp":1766188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"vor","delay-in-days":9,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Patient Saf Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Retained surgical items are rare yet serious complications that may occur despite correct instrument and sponge counts. Surgical sponges remain the most frequently retained items, with gauze marker strand retention being an uncommon mechanism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>A 69-year-old male with severe mitral regurgitation and triple-vessel coronary artery disease underwent mitral valve replacement with coronary artery bypass grafting. All surgical counts were verified as correct at the conclusion of surgery. Postoperative chest radiography, however, revealed two linear radio-opaque foreign bodies near the left lower sternum. Mediastinal re-exploration identified two radio-opaque strands, measuring 3.0\u00a0cm and 2.0\u00a0cm, attached to the left lower chest wall near the internal mammary artery stump. These were confirmed to be detached marker strands from Raytec gauzes. The patient\u2019s recovery was uneventful and he was discharged well.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This case illustrates that retained gauze fragments can occur despite correct counts due to fragmentation of radiopaque markers. Surgeons and operating room nurses should inspect gauzes for integrity, maintain vigilance when manipulating sponges in confined operative fields, and consider adjunct technologies such as radiofrequency or barcode tracking. In high-risk surgeries, postoperative imaging may be warranted even with accurate counts to ensure patient safety.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13037-025-00472-w","type":"journal-article","created":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T09:23:14Z","timestamp":1766222594000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Retained fragmented Raytec gauze eluding an alleged correct postoperative count following cardiothoracic surgery: case report of a rare \u201cnever event\u201d"],"prefix":"10.1186","volume":"19","author":[{"given":"Marco","family":"Lizwan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip Y. K.","family":"Pang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,20]]},"reference":[{"key":"472_CR1","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s13037-018-0166-0","volume":"12","author":"VM Steelman","year":"2018","unstructured":"Steelman VM, Shaw C, Shine L, Hardy-Fairbanks AJ. Retained surgical sponges: a descriptive study of 319 occurrences and contributing factors from 2012 to 2017. Patient Saf Surg. 2018;12:20. https:\/\/doi.org\/10.1186\/s13037-018-0166-0.","journal-title":"Patient Saf Surg"},{"issue":"7","key":"472_CR2","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1007\/s00268-011-1060-4","volume":"35","author":"VC Gibbs","year":"2011","unstructured":"Gibbs VC. Retained surgical items and minimally invasive surgery. World J Surg. 2011;35(7):1532\u20139. https:\/\/doi.org\/10.1007\/s00268-011-1060-4.","journal-title":"World J Surg"},{"key":"472_CR3","doi-asserted-by":"publisher","unstructured":"Grassi S, Focardi M, Santori F, et al. Lost and found: trends in litigation and compensation related to retained surgical foreign bodies. Front Med. 2025;12. https:\/\/doi.org\/10.3389\/fmed.2025.1526271.","DOI":"10.3389\/fmed.2025.1526271"},{"issue":"1","key":"472_CR4","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1097\/SLA.0b013e3180f633be","volume":"247","author":"NN Egorova","year":"2008","unstructured":"Egorova NN, Moskowitz A, Gelijns A, et al. Managing the prevention of retained surgical instruments: what is the value of counting? Ann Surg. 2008;247(1):13\u20138. https:\/\/doi.org\/10.1097\/SLA.0b013e3180f633be.","journal-title":"Ann Surg"},{"issue":"1","key":"472_CR5","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jamcollsurg.2012.08.026","volume":"216","author":"SPA Stawicki","year":"2013","unstructured":"Stawicki SPA, Moffatt-Bruce SD, Ahmed HM, et al. Retained surgical items: a problem yet to be solved. J Am Coll Surg. 2013;216(1):15\u201322. https:\/\/doi.org\/10.1016\/j.jamcollsurg.2012.08.026.","journal-title":"J Am Coll Surg"},{"issue":"11","key":"472_CR6","doi-asserted-by":"publisher","first-page":"4775","DOI":"10.1177\/0300060518788247","volume":"46","author":"V Gavri\u0107 Lovrec","year":"2018","unstructured":"Gavri\u0107 Lovrec V, Cokan A, Lukman L, Arko D, Taka\u010d I. Retained surgical needle and gauze after Cesarean section and adnexectomy: a case report and literature review. J Int Med Res. 2018;46(11):4775\u201380. https:\/\/doi.org\/10.1177\/0300060518788247.","journal-title":"J Int Med Res"},{"issue":"3","key":"472_CR7","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1007\/s13193-024-01934-w","volume":"15","author":"T Hoshi","year":"2024","unstructured":"Hoshi T. Short report of retained radiopaque marker in gauze and comparison of ease of dislodging and breaking. Indian J Surg Oncol. 2024;15(3):528\u201330. https:\/\/doi.org\/10.1007\/s13193-024-01934-w.","journal-title":"Indian J Surg Oncol"},{"issue":"3","key":"472_CR8","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1056\/NEJMsa021721","volume":"348","author":"AA Gawande","year":"2003","unstructured":"Gawande AA, Studdert DM, Orav EJ, Brennan TA, Zinner MJ. Risk factors for retained instruments and sponges after surgery. N Engl J Med. 2003;348(3):229\u201335. https:\/\/doi.org\/10.1056\/NEJMsa021721.","journal-title":"N Engl J Med"},{"issue":"7","key":"472_CR9","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1001\/archsurg.141.7.659","volume":"141","author":"A Macario","year":"2006","unstructured":"Macario A, Morris D, Morris S. Initial clinical evaluation of a handheld device for detecting retained surgical gauze sponges using radiofrequency identification technology. Arch Surg Chic Ill 1960. 2006;141(7):659\u201362. https:\/\/doi.org\/10.1001\/archsurg.141.7.659.","journal-title":"Arch Surg Chic Ill 1960"},{"issue":"4","key":"472_CR10","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/SLA.0b013e3181656cd5","volume":"247","author":"CC Greenberg","year":"2008","unstructured":"Greenberg CC, Diaz-Flores R, Lipsitz SR, et al. Bar-coding surgical sponges to improve safety: a randomized controlled trial. Ann Surg. 2008;247(4):612\u20136. https:\/\/doi.org\/10.1097\/SLA.0b013e3181656cd5.","journal-title":"Ann Surg"},{"issue":"10","key":"472_CR11","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1001\/archsurg.2012.1556","volume":"147","author":"VM Steelman","year":"2012","unstructured":"Steelman VM, Alasagheirin MH. Assessment of radiofrequency device sensitivity for the detection of retained surgical sponges in patients with morbid obesity. Arch Surg Chic Ill 1960. 2012;147(10):955\u201360. https:\/\/doi.org\/10.1001\/archsurg.2012.1556.","journal-title":"Arch Surg Chic Ill 1960"},{"issue":"1","key":"472_CR12","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1002\/aorn.12740","volume":"110","author":"VM Steelman","year":"2019","unstructured":"Steelman VM. Retained surgical items: evidence review and recommendations for prevention. AORN J. 2019;110(1):92\u20136. https:\/\/doi.org\/10.1002\/aorn.12740.","journal-title":"AORN J"},{"issue":"2","key":"472_CR13","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/ACO.0b013e328324f82d","volume":"22","author":"W Wan","year":"2009","unstructured":"Wan W, Le T, Riskin L, Macario A. Improving safety in the operating room: a systematic literature review of retained surgical sponges. Curr Opin Anaesthesiol. 2009;22(2):207\u201314. https:\/\/doi.org\/10.1097\/ACO.0b013e328324f82d.","journal-title":"Curr Opin Anaesthesiol"},{"issue":"3","key":"472_CR14","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1001\/archsurg.1990.01410150127025","volume":"125","author":"W Rappaport","year":"1990","unstructured":"Rappaport W, Haynes K. The retained surgical sponge following intra-abdominal surgery. A continuing problem. Arch Surg Chic Ill 1960. 1990;125(3):405\u20137. https:\/\/doi.org\/10.1001\/archsurg.1990.01410150127025.","journal-title":"Arch Surg Chic Ill 1960"},{"issue":"3","key":"472_CR15","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/s1553-7250(09)35016-3","volume":"35","author":"RR Cima","year":"2009","unstructured":"Cima RR, Kollengode A, Storsveen AS, et al. A multidisciplinary team approach to retained foreign objects. Jt Comm J Qual Patient Saf. 2009;35(3):123\u201332. https:\/\/doi.org\/10.1016\/s1553-7250(09)35016-3.","journal-title":"Jt Comm J Qual Patient Saf"},{"issue":"4","key":"472_CR16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1002\/aorn.14320","volume":"121","author":"K Van Anderson","year":"2025","unstructured":"Van Anderson K, Gamble JP, Clementz J, Echavez E. Implementing a standardized surgical count process for spine implant breakaway components. AORN J. 2025;121(4):257\u201366. https:\/\/doi.org\/10.1002\/aorn.14320.","journal-title":"AORN J"}],"container-title":["Patient Safety in Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13037-025-00472-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-025-00472-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-025-00472-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T21:02:23Z","timestamp":1767042143000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13037-025-00472-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,20]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["472"],"URL":"https:\/\/doi.org\/10.1186\/s13037-025-00472-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-8053743\/v1","asserted-by":"object"}]},"ISSN":["1754-9493"],"issn-type":[{"value":"1754-9493","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,20]]},"assertion":[{"value":"7 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional Review Board (IRB) approval was not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from patient to include the information in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"43"}}