{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T01:14:12Z","timestamp":1788138852612,"version":"build-2803163510"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"vor","delay-in-days":76,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Patient Saf Surg"],"DOI":"10.1186\/s13037-026-00491-1","type":"journal-article","created":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:34:21Z","timestamp":1781606061000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Unrecognized intraoperative thermal injury to the foot following arthroscopic anterior cruciate ligament reconstruction: a case report"],"prefix":"10.1186","volume":"20","author":[{"given":"Chun-Chieh","family":"Yeh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han-Ying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chung-Hsun","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8394-344X","authenticated-orcid":false,"given":"Wen-Tung","family":"Hsieh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,16]]},"reference":[{"key":"491_CR1","doi-asserted-by":"publisher","unstructured":"Figueroa D, Gonzalez W, Figueroa L, Figueroa F, Vaisman A. Complications in anterior cruciate ligament reconstruction. J Clin Orthop Trauma. 2024;61:102876. https:\/\/doi.org\/10.1016\/j.jcot.2024.102876. Erratum in: J Clin Orthop Trauma. 2025;74:103311. https:\/\/doi.org\/10.1016\/j.jcot.2025.103311. PMID: 39816721; PMCID: PMC11731265.","DOI":"10.1016\/j.jcot.2025.103311"},{"key":"491_CR2","doi-asserted-by":"publisher","unstructured":"Croke L. Guideline for prevention of hypothermia. AORN J. 2019;110(1):P8-P10. https:\/\/doi.org\/10.1002\/aorn.12761. PMID: 31246293.","DOI":"10.1002\/aorn.12761"},{"issue":"2","key":"491_CR3","doi-asserted-by":"crossref","first-page":"e605","DOI":"10.1016\/j.asmr.2020.12.002","volume":"3","author":"CF van Eck","year":"2021","unstructured":"van Eck CF, van Meel TAC, van den Bekerom MPJ, Zijl JAC, Kooistra B. Heat-Related Complications from Radiofrequency and Electrocautery Devices Used in Arthroscopic Surgery: A Systematic Review. Arthrosc Sports Med Rehabil. 2021;3(2):e605\u201313. PMID: 34027473; PMCID: PMC8129439.","journal-title":"Arthrosc Sports Med Rehabil"},{"issue":"4","key":"491_CR4","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.knee.2008.02.007","volume":"15","author":"YJ Lau","year":"2008","unstructured":"Lau YJ, Dao Q. Cutaneous burns from a fiberoptic cable tip during arthroscopy of the knee. Knee. 2008;15(4):333\u20135. https:\/\/doi.org\/10.1016\/j.knee.2008.02.007. Epub 2008 Jun 2. PMID: 18514527.","journal-title":"Knee"},{"issue":"4","key":"491_CR5","doi-asserted-by":"publisher","first-page":"rjaa068","DOI":"10.1093\/jscr\/rjaa068","volume":"2020","author":"J Chitnavis","year":"2020","unstructured":"Chitnavis J. Silent burn: the hidden danger and effects of bright light from fibre-optic cables in arthroscopic knee surgery. J Surg Case Rep. 2020;2020(4):rjaa068. https:\/\/doi.org\/10.1093\/jscr\/rjaa068. PMID: 32280444; PMCID: PMC7136709.","journal-title":"J Surg Case Rep"},{"issue":"6","key":"491_CR6","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1007\/s00540-010-1031-1","volume":"24","author":"G Uzun","year":"2010","unstructured":"Uzun G, Mutluoglu M, Evinc R, Ozdemir Y, Sen H. Severe burn injury associated with misuse of forced-air warming device. J Anesth. 2010;24(6):980\u20131. https:\/\/doi.org\/10.1007\/s00540-010-1031-1. Epub 2010 Oct 15. PMID: 20949288.","journal-title":"J Anesth"},{"issue":"4","key":"491_CR7","doi-asserted-by":"publisher","first-page":"391","DOI":"10.4097\/kjae.2012.62.4.391","volume":"62","author":"K Chung","year":"2012","unstructured":"Chung K, Lee S, Oh SC, Choi J, Cho HS. Thermal burn injury associated with a forced-air warming device. Korean J Anesthesiol. 2012;62(4):391\u20132. https:\/\/doi.org\/10.4097\/kjae.2012.62.4.391. Epub 2012 Apr 23. PMID: 22558510; PMCID: PMC3337390.","journal-title":"Korean J Anesthesiol"},{"key":"491_CR8","doi-asserted-by":"publisher","unstructured":"Wu X. The safe and efficient use of forced-air warming systems. AORN J. 2013;97(3):302-8. https:\/\/doi.org\/10.1016\/j.aorn.2012.12.008. PMID: 23452695.","DOI":"10.1016\/j.aorn.2012.12.008"},{"issue":"4","key":"491_CR9","doi-asserted-by":"publisher","first-page":"377","DOI":"10.4103\/0019-5413.98824","volume":"46","author":"JP Sharma","year":"2012","unstructured":"Sharma JP, Salhotra R. Tourniquets in orthopedic surgery. Indian J Orthop. 2012;46(4):377\u201383. https:\/\/doi.org\/10.4103\/0019-5413.98824. PMID: 22912509; PMCID: PMC3421924.","journal-title":"Indian J Orthop"},{"key":"491_CR10","doi-asserted-by":"publisher","unstructured":"Hodgins J, Wright J, Howard A, Fish J. Chlorhexidine-gluconate-related burns under a tourniquet: a report of two cases. JBJS Case Connect. 2012 Apr-Jun;2(2):e27. https:\/\/doi.org\/10.2106\/JBJS.CC.K.00072. PMID: 29252428.","DOI":"10.2106\/JBJS.CC.K.00072"},{"issue":"3","key":"491_CR11","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1016\/j.jor.2013.07.007","volume":"10","author":"C Supradeeptha","year":"2013","unstructured":"Supradeeptha C, Shandilya SM, Naresh A, Satyaprasad J. Aqueous based povidone-iodine related chemical burn under the tourniquet (a case report) and literature review. J Orthop. 2013;10(3):152\u20134. https:\/\/doi.org\/10.1016\/j.jor.2013.07.007. PMID: 24396233; PMCID: PMC3861682.","journal-title":"J Orthop"},{"issue":"1","key":"491_CR12","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s13037-025-00441-3","volume":"19","author":"MM Attia","year":"2025","unstructured":"Attia MM. Prevalence and root causes of operating room fires in the United States 2014\u20132024. Patient Saf Surg. 2025;19(1):18. https:\/\/doi.org\/10.1186\/s13037-025-00441-3. PMID: 40457428; PMCID: PMC12131830.","journal-title":"Patient Saf Surg"}],"container-title":["Patient Safety in Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13037-026-00491-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-026-00491-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13037-026-00491-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:27:30Z","timestamp":1788136050000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13037-026-00491-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,16]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["491"],"URL":"https:\/\/doi.org\/10.1186\/s13037-026-00491-1","relation":{},"ISSN":["1754-9493"],"issn-type":[{"value":"1754-9493","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,16]]},"assertion":[{"value":"20 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"According to the policy of the Research Ethics Committee of National Taiwan University Hospital, case reports do not require IRB approval. Written informed consent for publication was obtained from the patient. All identifying information has been removed to protect patient privacy.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent for publication was obtained from the patient.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"30"}}