{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T01:30:07Z","timestamp":1793410207968,"version":"4.5.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T00:00:00Z","timestamp":1572998400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T00:00:00Z","timestamp":1572998400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000024","name":"Canadian Institutes for Health Research","doi-asserted-by":"crossref","award":["AR7-162822"],"award-info":[{"award-number":["AR7-162822"]}],"id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Excessive respiratory muscle effort during mechanical ventilation may cause patient self-inflicted lung injury and load-induced diaphragm myotrauma, but there are no non-invasive methods to reliably detect elevated transpulmonary driving pressure and elevated respiratory muscle effort during assisted ventilation. We hypothesized that the swing in airway pressure generated by respiratory muscle effort under assisted ventilation when the airway is briefly occluded (\u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      ) could be used as a highly feasible non-invasive technique to screen for these conditions.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Respiratory muscle pressure (\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      ), dynamic transpulmonary driving pressure (\u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      , the difference between peak and end-expiratory transpulmonary pressure), and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      were measured daily in mechanically ventilated patients in two ICUs in Toronto, Canada. A conversion factor to predict \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      and\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      from \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      was derived and validated using cross-validation. External validity was assessed in an independent cohort (Nanjing, China).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Fifty-two daily recordings were collected in 16 patients. In this sample,\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L<\/jats:sub>\n                      were frequently excessively high:\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      exceeded 10\u2009cm\u00a0H\n                      <jats:sub>2<\/jats:sub>\n                      O on 84% of study days and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      exceeded 15\u2009cm\u00a0H\n                      <jats:sub>2<\/jats:sub>\n                      O on 53% of study days. \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      measurements accurately detected\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      &gt;\u200910\u2009cm\u00a0H\n                      <jats:sub>2<\/jats:sub>\n                      O (AUROC 0.92, 95% CI 0.83\u20130.97) and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      \u2009&gt;\u200915\u2009cm\u00a0H\n                      <jats:sub>2<\/jats:sub>\n                      O (AUROC 0.93, 95% CI 0.86\u20130.99). In the external validation cohort (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912), estimating\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      from \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      measurements detected excessively high\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>mus<\/jats:sub>\n                      and \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>L,dyn<\/jats:sub>\n                      with similar accuracy (AUROC \u2265\u20090.94).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      Measuring \u0394\n                      <jats:italic>P<\/jats:italic>\n                      <jats:sub>occ<\/jats:sub>\n                      enables accurate non-invasive detection of elevated respiratory muscle pressure and transpulmonary driving pressure. Excessive respiratory effort and transpulmonary driving pressure may be frequent in spontaneously breathing ventilated patients.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13054-019-2617-0","type":"journal-article","created":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T10:03:40Z","timestamp":1573034620000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":249,"title":["A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation"],"prefix":"10.1186","volume":"23","author":[{"given":"Michele","family":"Bertoni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irene","family":"Telias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Urner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Long","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Del Sorbo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eddy","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christer","family":"Sinderby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Beck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haibo","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenna","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arthur S.","family":"Slutsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niall D.","family":"Ferguson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurent J.","family":"Brochard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0990-6701","authenticated-orcid":false,"given":"Ewan C.","family":"Goligher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,6]]},"reference":[{"key":"2617_CR1","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1164\/rccm.201610-1972OC","volume":"196","author":"T Yoshida","year":"2017","unstructured":"Yoshida T, Nakahashi S, Nakamura M, Koyama Y, Roldan R, Torsani V, et al. Volume-controlled ventilation does not prevent injurious inflation during spontaneous effort. Am J Resp Crit Care. 2017;196:590\u2013601.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR2","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1056\/NEJMoa1005372","volume":"363","author":"L Papazian","year":"2010","unstructured":"Papazian L, Forel J-M, Gacouin A, Penot-Ragon C, Perrin G, Loundou A, et al. Neuromuscular blockers in early acute respiratory distress syndrome. New Engl J Medicine. 2010;363:1107\u201316.","journal-title":"New Engl J Medicine."},{"key":"2617_CR3","first-page":"43","volume":"164","author":"T Yoshida","year":"2018","unstructured":"Yoshida T, Amato MB, Kavanagh BP. Understanding spontaneous vs ventilator breaths: impact and monitoring. Intens Care Med. 2018;164:43.","journal-title":"Intens Care Med"},{"key":"2617_CR4","doi-asserted-by":"publisher","first-page":"1734","DOI":"10.1164\/ajrccm.164.9.2011150","volume":"164","author":"M Orozco-Levi","year":"2001","unstructured":"Orozco-Levi M, Lloreta J, Minguella J, Serrano S, Broquetas J, Gea J. Injury of the human diaphragm associated with exertion and chronic obstructive pulmonary disease. Am J Resp Crit Care. 2001;164:1734\u20139.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR5","doi-asserted-by":"publisher","first-page":"1802","DOI":"10.1152\/jappl.1985.59.6.1802","volume":"59","author":"S Hussain","year":"1985","unstructured":"Hussain S, Roussos C. Distribution of respiratory muscle and organ blood flow during endotoxic shock in dogs. J Appl Physiol. 1985;59:1802\u20138.","journal-title":"J Appl Physiol"},{"key":"2617_CR6","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1164\/rccm.201703-0536OC","volume":"197","author":"EC Goligher","year":"2018","unstructured":"Goligher EC, Dres M, Fan E, Rubenfeld GD, Scales DC, Herridge MS, et al. Mechanical ventilation-induced diaphragm atrophy strongly impacts clinical outcomes. Am J Resp Crit Care. 2018;197:204\u201313.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR7","doi-asserted-by":"crossref","unstructured":"Vaporidi K, Akoumianaki E, Telias I, Goligher EC, Brochard L, Georgopoulos D. Respiratory drive in critically ill patients: pathophysiology and clinical implications. Am J Respir Crit Care Med 2019;0.","DOI":"10.1164\/rccm.201903-0596SO"},{"issue":"11","key":"2617_CR8","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1164\/rccm.201805-0996OC","volume":"199","author":"Eliza R. Gentzler","year":"2019","unstructured":"Gentzler ER, Derry H, Ouyang DJ, Lief L, Berlin DA, Xu C, et al. Underdetection and undertreatment of dyspnea in critically ill patients. Am J Resp Crit Care. 2019;199:1377-1384.","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"2617_CR9","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1007\/s00134-016-4400-x","volume":"42","author":"T Mauri","year":"2016","unstructured":"Mauri T, Yoshida T, Bellani G, Goligher EC, Carteaux G, Rittayamai N, et al. Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives. Intens Care Med. 2016;42:1360\u201373.","journal-title":"Intens Care Med"},{"key":"2617_CR10","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1164\/ajrccm.164.3.2009018","volume":"164","author":"J Beck","year":"2001","unstructured":"Beck J, Gottfried SB, Navalesi P, Skrobik Y, Comtois N, ROSSINI M, et al. Electrical activity of the diaphragm during pressure support ventilation in acute respiratory failure. Am J Resp Crit Care. 2001;164:419\u201324.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR11","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1007\/s00134-015-3724-2","volume":"41","author":"EC Goligher","year":"2015","unstructured":"Goligher EC, Laghi F, Detsky ME, Farias P, Murray A, Brace D, et al. Measuring diaphragm thickness with ultrasound in mechanically ventilated patients: feasibility, reproducibility and validity. Intens Care Med. 2015;41:734.","journal-title":"Intens Care Med"},{"key":"2617_CR12","first-page":"438","volume":"195","author":"I Telias","year":"2018","unstructured":"Telias I, Damiani F, Brochard L. The airway occlusion pressure (P0.1) to monitor respiratory drive during mechanical ventilation: increasing awareness of a not-so-new problem. Intens Care Med. 2018;195:438\u20134.","journal-title":"Intens Care Med"},{"key":"2617_CR13","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1056\/NEJMsa1410639","volume":"372","author":"MB Amato","year":"2015","unstructured":"Amato MB, Meade MO, Slutsky AS, Brochard L, Costa EL, Schoenfeld DA, et al. Driving pressure and survival in the acute respiratory distress syndrome. New Engl J Med. 2015;372:747\u201355.","journal-title":"New Engl J Med"},{"key":"2617_CR14","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s13054-016-1290-9","volume":"20","author":"G Bellani","year":"2016","unstructured":"Bellani G, Grasselli G, Teggia-Droghi M, Mauri T, Coppadoro A, Brochard L, et al. Do spontaneous and mechanical breathing have similar effects on average transpulmonary and alveolar pressure? A clinical crossover study. Crit Care. 2016;20:142.","journal-title":"Crit Care"},{"key":"2617_CR15","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1034\/j.1399-3003.1999.14c06.x","volume":"14","author":"N Xirouhaki","year":"1999","unstructured":"Xirouhaki N, Kondili E, Mitrouska I, Siafakas N, Georgopoulos D. Response of respiratory motor output to varying pressure in mechanically ventilated patients. Eur Respiratory J. 1999;14:508\u201316.","journal-title":"Eur Respiratory J"},{"key":"2617_CR16","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s13054-015-0775-2","volume":"19","author":"L Liu","year":"2015","unstructured":"Liu L, Liu S, Xie J, Yang Y, Slutsky AS, Beck J, et al. Assessment of patient-ventilator breath contribution during neurally adjusted ventilatory assist in patients with acute respiratory failure. Crit Care. 2015;19:43.","journal-title":"Crit Care"},{"key":"2617_CR17","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1164\/ajrccm.155.3.9117025","volume":"155","author":"A Jubran","year":"1997","unstructured":"Jubran A, Tobin M. Pathophysiologic basis of acute respiratory distress in patients who fail a trial of weaning from mechanical ventilation. Am J Resp Crit Care. 1997;155:906\u201315.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR18","doi-asserted-by":"publisher","first-page":"2125","DOI":"10.1097\/CCM.0b013e31828a42e5","volume":"41","author":"G Carteaux","year":"2013","unstructured":"Carteaux G, Mancebo J, Mercat A, Dellamonica J, Richard J-CM, Aguirre-Bermeo H, et al. Bedside adjustment of proportional assist ventilation to target a predefined range of respiratory effort. Crit Care Med. 2013;41:2125\u201332.","journal-title":"Crit Care Med"},{"key":"2617_CR19","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1183\/09031936.95.08111901","volume":"8","author":"J Mancebo","year":"1995","unstructured":"Mancebo J, Isabey D, Lorino H, Lofaso F, Lemaire F, Brochard L. Comparative effects of pressure support ventilation and intermittent positive pressure breathing (IPPB) in non-intubated healthy subjects. Eur Respir J. 1995;8:1901\u20139.","journal-title":"Eur Respir J"},{"issue":"11","key":"2617_CR20","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1164\/rccm.200503-356OC","volume":"171","author":"Amal Jubran","year":"2005","unstructured":"Jubran A, Grant BJ, Laghi F, Parthasarathy S, Tobin MJ. Weaning prediction: esophageal pressure monitoring complements readiness testing. Am J Resp Crit Care. 2005;171:1252 1259.","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"2617_CR21","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1093\/bja\/aem214","volume":"99","author":"P Myles","year":"2007","unstructured":"Myles P, CUI J. Using the Bland-Altman method to measure agreement with repeated measures. Bja Br J Anaesth. 2007;99:309\u201311.","journal-title":"Bja Br J Anaesth"},{"key":"2617_CR22","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.jclinepi.2007.11.003","volume":"61","author":"AM Euser","year":"2008","unstructured":"Euser AM, Dekker FW, le Cessie S. A practical approach to Bland-Altman plots and variation coefficients for log transformed variables. J Clin Epidemiol. 2008;61:978\u201382.","journal-title":"J Clin Epidemiol"},{"key":"2617_CR23","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1002\/(SICI)1097-0258(20000229)19:4<453::AID-SIM350>3.0.CO;2-5","volume":"19","author":"DG Altman","year":"2000","unstructured":"Altman DG, Royston P. What do we mean by validating a prognostic model? Stat Med. 2000;19:453\u201373.","journal-title":"Stat Med"},{"key":"2617_CR24","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1152\/jappl.1978.44.6.829","volume":"44","author":"A Grassino","year":"1978","unstructured":"Grassino A, Goldman, Mead J, Sears T. Mechanics of the human diaphragm during voluntary contraction: statics. J Appl Physiol. 1978;44:829\u201339.","journal-title":"J Appl Physiol"},{"key":"2617_CR25","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1152\/jappl.1978.44.6.840","volume":"44","author":"GA Goldman","year":"1978","unstructured":"Goldman GA, Mead J, Sears T. Mechanics of the human diaphragm during voluntary contraction: dynamics. J Appl Physiol. 1978;44:840\u20138.","journal-title":"J Appl Physiol"},{"key":"2617_CR26","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1164\/rccm.201605-1081CP","volume":"195","author":"L Brochard","year":"2017","unstructured":"Brochard L, Slutsky A, Pesenti A. Mechanical ventilation to minimize progression of lung injury in acute respiratory failure. Am J Resp Crit Care. 2017;195:438\u201342.","journal-title":"Am J Resp Crit Care"},{"key":"2617_CR27","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1097\/ALN.0000000000002846","volume":"131","author":"G Bellani","year":"2019","unstructured":"Bellani G, Grassi A, Sosio S, Gatti S, Kavanagh BP, Pesenti A, et al. Driving pressure is associated with outcome during assisted ventilation in acute respiratory distress syndrome. Anesthesiology. 2019;131:594\u2013604.","journal-title":"Anesthesiology."},{"key":"2617_CR28","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s00134-018-5311-9","volume":"45","author":"G Bellani","year":"2019","unstructured":"Bellani G, Grassi A, Sosio S, Foti G. Plateau and driving pressure in the presence of spontaneous breathing. Intens Care Med. 2019;45:97\u20138.","journal-title":"Intens Care Med"},{"key":"2617_CR29","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1097\/CCM.0b013e31827caba0","volume":"41","author":"G Bellani","year":"2013","unstructured":"Bellani G, Mauri T, Coppadoro A, Grasselli G, Patroniti N, Spadaro S, et al. Estimation of patient\u2019s inspiratory effort from the electrical activity of the diaphragm. Crit Care Med. 2013;41:1483\u201391.","journal-title":"Crit Care Med"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-019-2617-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13054-019-2617-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-019-2617-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,4]],"date-time":"2020-11-04T19:47:58Z","timestamp":1604519278000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/s13054-019-2617-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,6]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["2617"],"URL":"https:\/\/doi.org\/10.1186\/s13054-019-2617-0","relation":{},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,6]]},"assertion":[{"value":"5 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 September 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Approval for the study procedures and data collected for this report was obtained from the research ethics board at the University Health Network (12-5582).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Dr. Goligher\u2019s laboratory receives support in the form of equipment from Getinge, and Dr. Goligher has received speaking honoraria from Getinge. The other authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"346"}}