{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T21:50:49Z","timestamp":1790632249942,"version":"4.1.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T00:00:00Z","timestamp":1617753600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T00:00:00Z","timestamp":1617753600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Teleultrasound provides an effective solution to problems that arise from limited medical resources, a lack of local expertise, and scenarios where the risk of infection is high. This study aims to explore the feasibility of the application of a 5G-powered robot-assisted teleultrasound diagnostic system in an intensive care unit.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this study, the robot-assisted teleultrasound diagnostic system MGIUS-R3 was used. Using 5G network technology, the doctor manipulates the robotic arm to perform teleultrasound examination. The doctor can adjust parameters via the teleultrasound control panel, and real-time transmission of audio, video and ultrasound images can facilitate simultaneous communication between both parties. All patients underwent robot-assisted teleultrasound examination and bedside ultrasound examination of the liver, gallbladder, pancreas, spleen, kidney, as well as assessment for pleural effusion and abdominal effusion. We evaluated the feasibility of the application of the robot-assisted teleultrasound diagnosis system in the intensive care unit in terms of consultation duration, image quality, and safety. We also compared diagnostic consistency and differences.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Apart from one patient who was excluded due to severe intestinal gas interference and poor image quality, a total of 32 patients were included in this study. Every patient completed all relevant examinations. Among them, 20 patients were male; 12 were female. The average age of the patients was 61\u2009\u00b1\u200920\u00a0years. The average duration of teleultrasound diagnosis was 17\u2009\u00b1\u20097\u00a0min. Of the 32 patients, 26 had positive results, 6 had negative results, and 5 had inconsistent diagnoses. The overall diagnostic results were basically the same, and there were no differences in diagnostic levels between the two. The overall average image quality score was 4.73 points, which represented a high-quality image. After robot-assisted teleultrasound examination, no significant changes were observed in the vital signs of patients as compared to before examination, and no examination-related complications were found.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The 5G-powered robot-assisted teleultrasound diagnostic system was associated with the benefits of clear images, simple operation, relatively high levels of consistency in terms of diagnostic results, higher levels of safety, and has considerable application value in the intensive care unit.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13054-021-03563-z","type":"journal-article","created":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T18:06:29Z","timestamp":1617818789000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":59,"title":["A 5G-powered robot-assisted teleultrasound diagnostic system in an intensive care unit"],"prefix":"10.1186","volume":"25","author":[{"given":"Shaobo","family":"Duan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luwen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongqing","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuaiyang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liuwei","family":"Hao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7305-4809","authenticated-orcid":false,"given":"Lianzhong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,7]]},"reference":[{"key":"3563_CR1","doi-asserted-by":"publisher","first-page":"e19417","DOI":"10.2196\/19417","volume":"8","author":"L Liu","year":"2020","unstructured":"Liu L, Gu J, Shao F, Liang X, Yue L, Cheng Q, et al. Application and preliminary outcomes of remote diagnosis and treatment during the COVID-19 outbreak: retrospective cohort study. JMIR Mhealth Uhealth. 2020;8:e19417.","journal-title":"JMIR Mhealth Uhealth"},{"key":"3563_CR2","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1016\/j.echo.2013.05.018","volume":"26","author":"CL Webb","year":"2013","unstructured":"Webb CL, Waugh CL, Grigsby J, Busenbark D, Berdusis K, Sahn DJ, et al. American Society of Echocardiography Telemedicine Collaborators\u2019 Group. Impact of telemedicine on hospital transport, length of stay, and medical outcomes in infants with suspected heart disease: a multicenter study. J Am Soc Echocardiogr. 2013;26:1090\u20138.","journal-title":"J Am Soc Echocardiogr"},{"key":"3563_CR3","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1177\/1357633X16689500","volume":"24","author":"CA Rouse","year":"2018","unstructured":"Rouse CA, Woods BT, Mahnke CB. A retrospective analysis of a pediatric tele-echocardiography service to treat, triage, and reduce trans-Pacific transport. J Telemed Telecare. 2018;24:224\u20139.","journal-title":"J Telemed Telecare"},{"key":"3563_CR4","doi-asserted-by":"publisher","first-page":"e14248","DOI":"10.2196\/14248","volume":"7","author":"L Liu","year":"2019","unstructured":"Liu L, Duan S, Zhang Y, Wu Y, Zhang L. Initial experience of the synchronized, real-time, interactive, remote transthoracic echocardiogram consultation system in rural China: longitudinal observational study. JMIR Med Inform. 2019;7:e14248.","journal-title":"JMIR Med Inform"},{"key":"3563_CR5","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1097\/00003246-198207000-00014","volume":"10","author":"BL Grundy","year":"1982","unstructured":"Grundy BL, Jones PK, Lovitt A. Telemedicine in critical care: problems in design, implementation, and assessment. Crit Care Med. 1982;10:471\u20135.","journal-title":"Crit Care Med"},{"key":"3563_CR6","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/01.CCM.0000104204.61296.41","volume":"32","author":"MJ Breslow","year":"2004","unstructured":"Breslow MJ, Rosenfeld BA, Doerfler M, Burke G, Yates G, Stone DJ, et al. Effect of a multiple-site intensive care unit telemedicine program on clinical and economic outcomes: an alternative paradigm for intensivist staffing. Crit Care Med. 2004;32:31\u20138.","journal-title":"Crit Care Med"},{"key":"3563_CR7","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1258\/jtt.2012.120208","volume":"18","author":"BA Kohl","year":"2012","unstructured":"Kohl BA, Fortino-Mullen M, Praestgaard A, Hanson CW, DiMartino J, Ochroch EA. The effect of ICU telemedicine on mortality and length of stay. J Telemed Telecare. 2012;18:282\u20136.","journal-title":"J Telemed Telecare"},{"key":"3563_CR8","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.jcrc.2007.01.006","volume":"22","author":"MJ Breslow","year":"2007","unstructured":"Breslow MJ. Remote ICU care programs: current status. J Crit Care. 2007;22:66\u201376.","journal-title":"J Crit Care"},{"key":"3563_CR9","doi-asserted-by":"publisher","first-page":"e256","DOI":"10.1097\/CCM.0000000000003626","volume":"47","author":"A Wong","year":"2019","unstructured":"Wong A, Galarza L, Duska F. Critical care ultrasound: a systematic review of international training competencies and program. Crit Care Med. 2019;47:e256\u201362.","journal-title":"Crit Care Med"},{"key":"3563_CR10","doi-asserted-by":"publisher","first-page":"2479","DOI":"10.1097\/CCM.0000000000001216","volume":"43","author":"HL Frankel","year":"2015","unstructured":"Frankel HL, Kirkpatrick AW, Elbarbary M, Blaivas M, Desai H, Evans D, et al. Guidelines for the appropriate use of bedside general and cardiac ultrasonography in the evaluation of critically ill patients-part I: general ultrasonography. Crit Care Med. 2015;43:2479\u2013502.","journal-title":"Crit Care Med"},{"key":"3563_CR11","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1177\/0885066618777187","volume":"35","author":"PP Olivieri","year":"2020","unstructured":"Olivieri PP, Verceles AC, Hurley JM, Zubrow MT, Jeudy J, McCurdy MT. A pilot study of ultrasonography-Na\u00efve operators\u2019 ability to use tele-ultrasonography to assess the heart and lung. J Intensive Care Med. 2020;35:672\u20138.","journal-title":"J Intensive Care Med"},{"key":"3563_CR12","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.chest.2020.06.068","volume":"159","author":"R Ye","year":"2020","unstructured":"Ye R, Zhou X, Shao F, Xiong L, Hong J, Huang H, et al. Feasibility of a 5G-based robot-assisted remote ultrasound system for cardiopulmonary assessment of patients with COVID-19. Chest. 2020;159:270\u201381.","journal-title":"Chest"},{"key":"3563_CR13","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1002\/jum.15406","volume":"40","author":"J Wang","year":"2020","unstructured":"Wang J, Peng C, Zhao Y, Ye R, Hong J, Huang H, Chen L. Application of a robotic tele-echography system for COVID-19 pneumonia. J Ultrasound Med. 2020;40:385\u201390.","journal-title":"J Ultrasound Med"},{"key":"3563_CR14","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1097\/CCM.0000000000004190","volume":"48","author":"S Subramanian","year":"2020","unstructured":"Subramanian S, Pamplin JC, Hravnak M, Hielsberg C, Riker R, Rincon F, et al. Tele-critical care: an update from the society of critical care medicine tele-ICU Committee. Crit Care Med. 2020;48:553\u201361.","journal-title":"Crit Care Med"},{"key":"3563_CR15","doi-asserted-by":"publisher","first-page":"e540","DOI":"10.1097\/CCM.0000000000004288","volume":"48","author":"AR Levine","year":"2020","unstructured":"Levine AR, Verceles AC, McCurdy MT. A simple but often ignored formula to improve critical care: \u201cTelemedicine + Ultrasound = Tele-Ultrasound.\u201d Crit Care Med. 2020;48:e540.","journal-title":"Crit Care Med"},{"key":"3563_CR16","first-page":"306259","volume":"2015","author":"AC Ferreira","year":"2015","unstructured":"Ferreira AC, O\u2019Mahony E, Oliani AH, Araujo J\u00fanior E, da Silva CF. Teleultrasound: historical perspective and clinical application. Int J Telemed Appl. 2015;2015:306259.","journal-title":"Int J Telemed Appl"},{"key":"3563_CR17","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1097\/00005373-200104000-00007","volume":"50","author":"GS Rozycki","year":"2001","unstructured":"Rozycki GS, Pennington SD, Feliciano DV. Surgeon-performed ultrasound in the critical care setting: its use as an extension of the physical examination to detect pleural effusion. J Trauma. 2001;50:636\u201342.","journal-title":"J Trauma"},{"key":"3563_CR18","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1148\/radiology.155.3.3890007","volume":"155","author":"PW Ralls","year":"1985","unstructured":"Ralls PW, Colletti PM, Lapin SA, Chandrasoma PA, Boswell WD Jr, Ngo C, et al. (1985) Real-time sonography in suspected acute cholecystitis. Prospective evaluation of primary and secondary signs. Radiology. 1985;155:767\u201371.","journal-title":"Radiology"},{"key":"3563_CR19","first-page":"212","volume":"95","author":"A Vilchis","year":"2003","unstructured":"Vilchis A, Masuda K, Troccaz J, Cinquin P. Robot-based tele-echography: the TER system. Stud Health Technol Inform. 2003;95:212\u20137.","journal-title":"Stud Health Technol Inform"},{"key":"3563_CR20","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s10916-008-9128-x","volume":"32","author":"R Takeuchi","year":"2008","unstructured":"Takeuchi R, Harada H, Masuda K, Ota GI, Yokoi M, Teramura N, et al. Field testing of a remote controlled robotic tele-echo system in an ambulance using broadband mobile communication technology. J Med Syst. 2008;32:235\u201342.","journal-title":"J Med Syst"},{"key":"3563_CR21","doi-asserted-by":"publisher","first-page":"2603","DOI":"10.1002\/jum.14619","volume":"37","author":"SJ Adams","year":"2018","unstructured":"Adams SJ, Burbridge BE, Badea A, Kanigan N, Bustamante L, Babyn P, et al. A crossover comparison of standard and telerobotic approaches to prenatal sonography. J Ultrasound Med. 2018;37:2603\u201312.","journal-title":"J Ultrasound Med"},{"key":"3563_CR22","first-page":"66","volume":"28","author":"L Yanhua","year":"2019","unstructured":"Yanhua L, Yuanji Z, Li M. Preliminary application study of using tele-ultrasound robot system in volunteers. Chin J Ultrasonogr. 2019;28:66\u201370.","journal-title":"Chin J Ultrasonogr"},{"key":"3563_CR23","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.carj.2016.08.002","volume":"68","author":"SJ Adams","year":"2017","unstructured":"Adams SJ, Burbridge BE, Badea A, Langford L, Vergara V, Bryce R, et al. Initial experience using a telerobotic ultrasound system for adult abdominal sonography. Can Assoc Radiol J. 2017;68:308\u201314.","journal-title":"Can Assoc Radiol J"},{"key":"3563_CR24","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1002\/jum.15285","volume":"39","author":"G Soldati","year":"2020","unstructured":"Soldati G, Smargiassi A, Inchingolo R, Buonsenso D, Perrone T, Briganti DF, et al. Proposal for international standardization of the use of lung ultrasound for patients with COVID-19: a simple, quantitative. Reprod Method J Ultrasound Med. 2020;39:1413\u20139.","journal-title":"Reprod Method J Ultrasound Med"},{"key":"3563_CR25","doi-asserted-by":"publisher","first-page":"1459","DOI":"10.1002\/jum.15284","volume":"39","author":"G Soldati","year":"2020","unstructured":"Soldati G, Smargiassi A, Inchingolo R, Buonsenso D, Perrone T, Briganti DF, et al. Is there a role for lung ultrasound during the COVID-19 pandemic? J Ultrasound Med. 2020;39:1459\u201362.","journal-title":"J Ultrasound Med"},{"key":"3563_CR26","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1109\/TUFFC.2020.3020721","volume":"67","author":"S Wu","year":"2020","unstructured":"Wu S, Wu D, Ye R, Li K, Lu Y, Xu J, et al. Pilot study of robot-assisted teleultrasound based on 5G network: a new feasible strategy for early imaging assessment during COVID-19 pandemic. IEEE Trans Ultrason Ferroelectr Freq Control. 2020;67:2241\u20138.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"3563_CR27","first-page":"7796","volume":"24","author":"RZ Yu","year":"2020","unstructured":"Yu RZ, Li YQ, Peng CZ, Ye RZ, He Q. Role of 5G-powered remote robotic ultrasound during the COVID-19 outbreak: insights from two cases. Eur Rev Med Pharmacol Sci. 2020;24:7796\u2013800.","journal-title":"Eur Rev Med Pharmacol Sci"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-021-03563-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13054-021-03563-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-021-03563-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T18:12:21Z","timestamp":1617819141000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/s13054-021-03563-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,7]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["3563"],"URL":"https:\/\/doi.org\/10.1186\/s13054-021-03563-z","relation":{},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,7]]},"assertion":[{"value":"7 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All examinations were carried out with the informed consent of patients and their families, and were approved and supported by doctors and nurses.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approved and consent to participate"}},{"value":"The authors declare that they have no conflicts of interest with the contents of this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"134"}}