{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T08:33:00Z","timestamp":1775809980567,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T00:00:00Z","timestamp":1688428800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T00:00:00Z","timestamp":1688428800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir (\u201cBag-CPAP\u201d) designed to minimize oxygen consumption, and compared it with other CPAP devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO\n                      <jats:sub>2<\/jats:sub>\n                      targets (40\u201360% and 80\u2013100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10\u00a0cm H\n                      <jats:sub>2<\/jats:sub>\n                      O were tested and fraction of inspired oxygen (FiO\n                      <jats:sub>2<\/jats:sub>\n                      ) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO\n                      <jats:sub>2<\/jats:sub>\n                      , PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All six systems tested in the bench study reached the minimal FiO\n                      <jats:sub>2<\/jats:sub>\n                      target of 40% and four reached at least 80% FiO\n                      <jats:sub>2<\/jats:sub>\n                      while maintaining PEEP in the predefined range. Device-delivered FiO\n                      <jats:sub>2<\/jats:sub>\n                      \/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO\n                      <jats:sub>2<\/jats:sub>\n                      target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (&gt;\u200990%) and moderate (&gt;\u200950%) FiO\n                      <jats:sub>2<\/jats:sub>\n                      with an oxygen flow rate of 15 [15\u201316] and 8 [7\u20139] L\/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO\n                      <jats:sub>2<\/jats:sub>\n                      increased.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13054-023-04542-2","type":"journal-article","created":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T11:03:01Z","timestamp":1688554981000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["A new reservoir-based CPAP with low oxygen consumption: the Bag-CPAP"],"prefix":"10.1186","volume":"27","author":[{"given":"Elo\u00efse","family":"de Beaufort","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guillaume","family":"Carteaux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Morin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arnaud","family":"Lesimple","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne-Fleur","family":"Haudebourg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emeline","family":"Fresnel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damien","family":"Duval","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandre","family":"Broc","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alain","family":"Mercat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurent","family":"Brochard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominique","family":"Savary","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Beloncle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armand","family":"Mekontso Dessap","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Christophe","family":"Richard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,7,4]]},"reference":[{"key":"4542_CR1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0240645","volume":"15","author":"S Alviset","year":"2020","unstructured":"Alviset S, Riller Q, Aboab J, Dilworth K, Billy P-A, Lombardi Y, et al. Continuous Positive Airway Pressure (CPAP) face-mask ventilation is an easy and cheap option to manage a massive influx of patients presenting acute respiratory failure during the SARS-CoV-2 outbreak: a retrospective cohort study. PLoS ONE. 2020;15: e0240645.","journal-title":"PLoS ONE"},{"key":"4542_CR2","doi-asserted-by":"publisher","first-page":"2001692","DOI":"10.1183\/13993003.01692-2020","volume":"56","author":"M Oranger","year":"2020","unstructured":"Oranger M, Gonzalez-Bermejo J, Dacosta-Noble P, Llontop C, Guerder A, Trosini-Desert V, et al. Continuous positive airway pressure to avoid intubation in SARS-CoV-2 pneumonia: a two-period retrospective case-control study. Eur Respir J. 2020;56:2001692.","journal-title":"Eur Respir J"},{"key":"4542_CR3","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.202211-2174CP","author":"A Mekontso Dessap","year":"2023","unstructured":"Mekontso Dessap A, Richard J-CM, Baker T, Godard A, Carteaux G. Technical innovation in critical care in a world of constraints: lessons from the COVID-19 pandemic. Am J Respir Crit Care Med. 2023. https:\/\/doi.org\/10.1164\/rccm.202211-2174CP.","journal-title":"Am J Respir Crit Care Med"},{"key":"4542_CR4","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1007\/s00134-018-5391-6","volume":"45","author":"DA Mekontso","year":"2019","unstructured":"Mekontso DA. Frugal innovation for critical care. Intensive Care Med. 2019;45:252\u20134.","journal-title":"Intensive Care Med"},{"key":"4542_CR5","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s13613-021-00828-2","volume":"11","author":"G Carteaux","year":"2021","unstructured":"Carteaux G, Pons M, Morin F, Tuffet S, Lesimple A, Badat B, et al. Continuous positive airway pressure for respiratory support during COVID-19 pandemic: a frugal approach from bench to bedside. Ann Intensive Care. 2021;11:38.","journal-title":"Ann Intensive Care"},{"key":"4542_CR6","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2022.0028","author":"GD Perkins","year":"2022","unstructured":"Perkins GD, Ji C, Connolly BA, Couper K, Lall R, Baillie JK, et al. Effect of noninvasive respiratory strategies on intubation or mortality among patients with acute hypoxemic respiratory failure and COVID-19: the RECOVERY-RS randomized clinical trial. JAMA. 2022. https:\/\/doi.org\/10.1001\/jama.2022.0028.","journal-title":"JAMA"},{"key":"4542_CR7","first-page":"279","volume":"12","author":"C Caillard","year":"2020","unstructured":"Caillard C, Fresnel E, Kerfourn A, Cuvelier A, Patout M. Mise en place et validation d\u2019un mod\u00e8le exp\u00e9rimental pour l\u2019\u00e9valuation des interfaces de ventilation non invasive. Rev Mal Respir Actual. 2020;12:279\u201380.","journal-title":"Rev Mal Respir Actual"},{"key":"4542_CR8","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1007\/s00134-021-06459-2","volume":"47","author":"DL Grieco","year":"2021","unstructured":"Grieco DL, Maggiore SM, Roca O, Spinelli E, Patel BK, Thille AW, et al. Non-invasive ventilatory support and high-flow nasal oxygen as first-line treatment of acute hypoxemic respiratory failure and ARDS. Intensive Care Med. 2021;47:851\u201366.","journal-title":"Intensive Care Med"},{"key":"4542_CR9","doi-asserted-by":"crossref","unstructured":"Vincent J-L. Le manuel de r\u00e9animation, soins intensifs et m\u00e9decine d\u2019urgence. 4e \u00e9d. Paris Berlin Heidelberg [etc.]: Springer; 2013.","DOI":"10.1007\/978-2-8178-0487-3"},{"key":"4542_CR10","doi-asserted-by":"publisher","first-page":"2559","DOI":"10.2147\/COPD.S141976","volume":"12","author":"JZ Chen","year":"2017","unstructured":"Chen JZ, Katz IM, Pichelin M, Zhu K, Caillibotte G, Noga ML, et al. Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas. Int J Chronic Obstr Pulm Dis. 2017;12:2559\u201371.","journal-title":"Int J Chronic Obstr Pulm Dis"},{"key":"4542_CR11","doi-asserted-by":"publisher","first-page":"117","DOI":"10.4187\/respcare.06359","volume":"64","author":"JZ Chen","year":"2019","unstructured":"Chen JZ, Katz IM, Pichelin M, Zhu K, Caillibotte G, Finlay WH, et al. In vitro\u2013in silico comparison of pulsed oxygen delivery from portable oxygen concentrators versus continuous flow oxygen delivery. Respir Care. 2019;64:117\u201329.","journal-title":"Respir Care"},{"key":"4542_CR12","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.4187\/respcare.05930","volume":"63","author":"M Vargas","year":"2018","unstructured":"Vargas M, Marra A, Vivona L, Ball L, Marin\u00f2 V, Pelosi P, et al. Performances of CPAP devices with an oronasal mask. Respir Care. 2018;63:1033\u20139.","journal-title":"Respir Care"},{"key":"4542_CR13","doi-asserted-by":"crossref","unstructured":"O\u2019Driscoll BR, Howard LS, Earis J, Mak V. BTS guideline for oxygen use in adults in healthcare and emergency settings. Thorax. 2017;72:ii1\u201390.","DOI":"10.1136\/thoraxjnl-2016-209729"},{"key":"4542_CR14","first-page":"67","volume":"47","author":"HCA Lassen","year":"1954","unstructured":"Lassen HCA. The epidemic of poliomyelitis in Copenhagen, 1952. Proc R Soc Med. 1954;47:67\u201371.","journal-title":"Proc R Soc Med"},{"key":"4542_CR15","unstructured":"A nightmare on repeat\u2014India is running out of oxygen again. BBC News [Internet]. 2021 Apr 23 [cited 2023 Jan 30]; Available from: https:\/\/www.bbc.com\/news\/uk-56841381"},{"key":"4542_CR16","doi-asserted-by":"crossref","unstructured":"COVID-ICU Group on behalf of the REVA Network and the COVID-ICU Investigators. Clinical characteristics and day-90 outcomes of 4244 critically ill adults with COVID-19: a prospective cohort study. Intensive Care Med. 2021;47:60\u201373.","DOI":"10.1007\/s00134-020-06294-x"},{"key":"4542_CR17","doi-asserted-by":"publisher","first-page":"2352","DOI":"10.1001\/jama.284.18.2352","volume":"284","author":"C Delclaux","year":"2000","unstructured":"Delclaux C, L\u2019Her E, Alberti C, Mancebo J, Abroug F, Conti G, et al. Treatment of acute hypoxemic nonhypercapnic respiratory insufficiency with continuous positive airway pressure delivered by a face mask: a randomized controlled trial. JAMA. 2000;284:2352\u201360.","journal-title":"JAMA"},{"key":"4542_CR18","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1093\/bja\/62.3.340","volume":"62","author":"PJ Venn","year":"1989","unstructured":"Venn PJ. Evaluation of the Ambu CPAP system. Br J Anaesth. 1989;62:340\u20137.","journal-title":"Br J Anaesth"},{"key":"4542_CR19","doi-asserted-by":"publisher","first-page":"88","DOI":"10.33393\/ao.2021.2284","volume":"8","author":"A Coppadoro","year":"2021","unstructured":"Coppadoro A, Bellani G. A novel Venturi system to generate high flow with titratable FiO2. AboutOpen. 2021;8:88\u201391.","journal-title":"AboutOpen"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-023-04542-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13054-023-04542-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-023-04542-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T11:08:30Z","timestamp":1688555310000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/s13054-023-04542-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,4]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4542"],"URL":"https:\/\/doi.org\/10.1186\/s13054-023-04542-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2790211\/v1","asserted-by":"object"}]},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,4]]},"assertion":[{"value":"7 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The clinical study was approved by the institutional ethical committee of the French Intensive Care Society as a component of standard care. Patient consent was waived.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"G. Carteaux reports personal fees from Air Liquide Medical System and L\u00f6wenstein, outside the submitted work. E. de Beaufort is a PhD student in Med<sub>2<\/sub>Lab which is partially\u00a0funded by Air Liquide Medical Systems. A. Lesimple is a PhD student in Med<sub>2<\/sub>Lab which is partially\u00a0funded by Air Liquide Medical Systems. A. Broc reports a salary from Air Liquid Medical Systems. D. Savary reports personal fees from Air Liquide Medical Systems. F. Beloncle reports personal fees from L\u00f6wenstein Medical, Air Liquide Medical Systems, and research support from Covidien, GE Healthcare and Getinge Group, outside this work. A. Mercat reports personal fees from Faron Pharmaceuticals, Air Liquide Medical Systems, Pfizer, Resmed and Draeger, and grants and personal fees from Fisher and Paykel and Covidien, outside this work. A. Mekontso Dessap reports grants from Fischer Paykel, Baxter, Philips, Ferring and GSK, personal fees from Air Liquide, Baxter, Amomed, Getingue and Addmedica, outside the submitted work. JC Richard reports part time salary for research activities (Med<sub>2<\/sub>Lab) from Air Liquide Medical Systems and Vygon. All other authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"262"}}