{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T13:06:33Z","timestamp":1763643993734},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T00:00:00Z","timestamp":1692921600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T00:00:00Z","timestamp":1692921600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Mechanical ventilation is applied to unload the respiratory muscles, but knowledge about transpulmonary driving pressure (\u0394<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>) is important to minimize lung injury. We propose a method to estimate \u0394<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub> during neurally synchronized assisted ventilation, with a simple intervention of lowering the assist for one breath (\u201clower assist maneuver\u201d, LAM).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In 24 rabbits breathing spontaneously with imposed loads, titrations of increasing assist were performed, with two neurally synchronized modes: neurally adjusted ventilatory assist (NAVA) and neurally triggered pressure support (NPS). Two single LAM breaths (not sequentially, but independently) were performed at each level of assist by acutely setting the assist to zero cm H2O (NPS) or NAVA level 0\u00a0cm H2O\/uV (NAVA) for one breath. NPS and NAVA titrations were followed by titrations in controlled-modes (volume control, VC and pressure control, PC), under neuro-muscular blockade. Breaths from the NAVA\/NPS titrations were matched (for flow and volume) to VC or PC. Throughout all runs, we measured diaphragm electrical activity (Edi) and esophageal pressure (<jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub>). We measured \u0394<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub> during the spontaneous modes (<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub>) and controlled mechanical ventilation (CMV) modes (<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:sub>CMV<\/jats:sub>) with the esophageal balloon. From the LAMs, we derived an estimation of \u0394<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub> (\u201c<jats:italic>P<\/jats:italic><jats:sub>L_LAM<\/jats:sub>\u201d) using a correction factor (ratio of volume during the LAM and volume during assist) and compared it to measured \u0394<jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub> during passive (VC or PC) and spontaneous breathing (NAVA or NPS). A requirement for the LAM was similar Edi to the assisted breath.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>All animals successfully underwent titrations and LAMs for NPS\/NAVA. One thousand seven-hundred ninety-two (1792) breaths were matched to passive ventilation titrations (matched Vt, <jats:italic>r<\/jats:italic>\u2009=\u20090.99). <jats:italic>P<\/jats:italic><jats:sub>L_LAM<\/jats:sub> demonstrated strong correlation with <jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:sub>CMV<\/jats:sub> (<jats:italic>r<\/jats:italic>\u2009=\u20090.83), and <jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub> (<jats:italic>r<\/jats:italic>\u2009=\u20090.77). Bland\u2013Altman analysis revealed little difference between the predicted <jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:sub>LAM<\/jats:sub> and measured <jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:sub>CMV<\/jats:sub> (Bias\u2009=\u20090.49\u00a0cm H2O and 1.96SD\u2009=\u20093.09\u00a0cm H2O). For <jats:italic>P<\/jats:italic><jats:sub>L<\/jats:sub>_<jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub>, the bias was 2.2\u00a0cm H2O and 1.96SD was 3.4\u00a0cm H2O. Analysis of Edi and <jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub> at peak Edi showed progressively increasing uncoupling with increasing assist.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>During synchronized mechanical ventilation, a LAM breath allows for estimations of transpulmonary driving pressure, without measuring <jats:italic>P<\/jats:italic><jats:sub>ES<\/jats:sub>, and follows a mathematical transfer function to describe respiratory muscle unloading during synchronized assist.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13054-023-04607-2","type":"journal-article","created":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T08:03:08Z","timestamp":1692950588000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Estimation of transpulmonary driving pressure during synchronized mechanical ventilation using a single lower assist maneuver (LAM) in rabbits: a comparison to measurements made with an esophageal balloon"],"prefix":"10.1186","volume":"27","author":[{"given":"Ling","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong-Liang","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cong","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Purab","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danqiong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennifer","family":"Beck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christer","family":"Sinderby","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,8,25]]},"reference":[{"issue":"12","key":"4607_CR1","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1038\/71012","volume":"5","author":"C Sinderby","year":"1999","unstructured":"Sinderby C, Navalesi P, Beck J, Skrobik Y, Comtois N, Friberg S, et al. Neural control of mechanical ventilation in respiratory failure. Nat Med. 1999;5(12):1433\u20136.","journal-title":"Nat Med"},{"issue":"9","key":"4607_CR2","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.1007\/s00134-008-1163-z","volume":"34","author":"O Moerer","year":"2008","unstructured":"Moerer O, Beck J, Brander L, Costa R, Quintel M, Slutsky AS, et al. Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation. Intensive Care Med. 2008;34(9):1615\u201323.","journal-title":"Intensive Care Med"},{"issue":"1","key":"4607_CR3","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1186\/s13054-015-0971-0","volume":"19","author":"L Liu","year":"2015","unstructured":"Liu L, Xia F, Yang Y, Longhini F, Navalesi P, Beck J, et al. Neural versus pneumatic control of pressure support in patients with chronic obstructive pulmonary diseases at different levels of positive end expiratory pressure: a physiological study. Crit Care. 2015;19(1):244.","journal-title":"Crit Care"},{"issue":"7","key":"4607_CR4","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1007\/s00134-012-2588-y","volume":"38","author":"G Grasselli","year":"2012","unstructured":"Grasselli G, Beck J, Mirabella L, Pesenti A, Slutsky AS, Sinderby C. Assessment of patient-ventilator breath contribution during neurally adjusted ventilatory assist. Intensive Care Med. 2012;38(7):1224\u201332.","journal-title":"Intensive Care Med"},{"issue":"1","key":"4607_CR5","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s13054-015-0775-2","volume":"19","author":"L Liu","year":"2015","unstructured":"Liu L, Liu S, Xie J, Yang Y, Slutsky AS, Beck J, et al. Assessment of patient-ventilator breath contribution during neurally adjusted ventilatory assist in patients with acute respiratory failure. Crit Care. 2015;19(1):43.","journal-title":"Crit Care"},{"issue":"1","key":"4607_CR6","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1152\/japplphysiol.00071.2019","volume":"127","author":"AH Jonkman","year":"2019","unstructured":"Jonkman AH, Jansen D, Gadgil S, Keijzer C, Girbes ARJ, Scheffer GJ, et al. Monitoring patient-ventilator breath contribution in the critically ill during neurally adjusted ventilatory assist: reliability and improved algorithms for bedside use. J Appl Physiol (1985). 2019;127(1):264\u201371.","journal-title":"J Appl Physiol (1985)"},{"key":"4607_CR7","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1113\/jphysiol.1989.sp017595","volume":"411","author":"DR Claflin","year":"1989","unstructured":"Claflin DR, Faulkner JA. The force-velocity relationship at high shortening velocities in the soleus muscle of the rat. J Physiol. 1989;411:627\u201337.","journal-title":"J Physiol"},{"issue":"4","key":"4607_CR8","first-page":"1553","volume":"3","author":"GC Sieck","year":"2013","unstructured":"Sieck GC, Ferreira LF, Reid MB, Mantilla CB. Mechanical properties of respiratory muscles. Compr Physiol. 2013;3(4):1553\u201367.","journal-title":"Compr Physiol"},{"issue":"3","key":"4607_CR9","first-page":"753","volume":"56","author":"S Newman","year":"1984","unstructured":"Newman S, Road J, Bellemare F, Clozel JP, Lavigne CM, Grassino A. Respiratory muscle length measured by sonomicrometry. J Appl Physiol Respir Environ Exerc Physiol. 1984;56(3):753\u201364.","journal-title":"J Appl Physiol Respir Environ Exerc Physiol"},{"issue":"1","key":"4607_CR10","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1152\/jappl.1992.72.1.302","volume":"72","author":"PH Saldiva","year":"1992","unstructured":"Saldiva PH, Zin WA, Santos RL, Eidelman DH, Milic-Emili J. Alveolar pressure measurement in open-chest rats. J Appl Physiol (1985). 1992;72(1):302\u20136.","journal-title":"J Appl Physiol (1985)"},{"issue":"2","key":"4607_CR11","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.resp.2009.02.015","volume":"166","author":"F Lecomte","year":"2009","unstructured":"Lecomte F, Brander L, Jalde F, Beck J, Qui H, Elie C, et al. Physiological response to increasing levels of neurally adjusted ventilatory assist (NAVA). Respir Physiol Neurobiol. 2009;166(2):117\u201324.","journal-title":"Respir Physiol Neurobiol"},{"issue":"3","key":"4607_CR12","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1378\/chest.08-1747","volume":"135","author":"L Brander","year":"2009","unstructured":"Brander L, Leong-Poi H, Beck J, Brunet F, Hutchison SJ, Slutsky AS, et al. Titration and implementation of neurally adjusted ventilatory assist in critically ill patients. Chest. 2009;135(3):695\u2013703.","journal-title":"Chest"},{"issue":"2","key":"4607_CR13","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1164\/ajrccm.157.2.9701063","volume":"157","author":"JP Viale","year":"1998","unstructured":"Viale JP, Duperret S, Mahul P, Delafosse B, Delpuech C, Weismann D, et al. Time course evolution of ventilatory responses to inspiratory unloading in patients. Am J Respir Crit Care Med. 1998;157(2):428\u201334.","journal-title":"Am J Respir Crit Care Med"},{"issue":"4","key":"4607_CR14","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1111\/apha.12321","volume":"211","author":"KA Edman","year":"2014","unstructured":"Edman KA. The force-velocity relationship at negative loads (assisted shortening) studied in isolated, intact muscle fibres of the frog. Acta Physiol (Oxf). 2014;211(4):609\u201316.","journal-title":"Acta Physiol (Oxf)"},{"issue":"3","key":"4607_CR15","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1378\/chest.06-1909","volume":"131","author":"C Sinderby","year":"2007","unstructured":"Sinderby C, Beck J, Spahija J, de Marchie M, Lacroix J, Navalesi P, et al. Inspiratory muscle unloading by neurally adjusted ventilatory assist during maximal inspiratory efforts in healthy subjects. Chest. 2007;131(3):711\u20137.","journal-title":"Chest"},{"issue":"4","key":"4607_CR16","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1097\/00000542-199310000-00005","volume":"79","author":"MD Fratacci","year":"1993","unstructured":"Fratacci MD, Kimball WR, Wain JC, Kacmarek RM, Polaner DM, Zapol WM. Diaphragmatic shortening after thoracic surgery in humans. Effects of mechanical ventilation and thoracic epidural anesthesia. Anesthesiology. 1993;79(4):654\u201365.","journal-title":"Anesthesiology"},{"issue":"2","key":"4607_CR17","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1152\/jappl.1986.60.2.670","volume":"60","author":"JW Fitting","year":"1986","unstructured":"Fitting JW, Easton PA, Grassino AE. Velocity of shortening of inspiratory muscles and inspiratory flow. J Appl Physiol (1985). 1986;60(2):670\u20137.","journal-title":"J Appl Physiol (1985)"},{"issue":"2","key":"4607_CR18","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1152\/jappl.1986.61.2.719","volume":"61","author":"E van Lunteren","year":"1986","unstructured":"van Lunteren E, Cherniack NS. Electrical and mechanical activity of respiratory muscles during hypercapnia. J Appl Physiol (1985). 1986;61(2):719\u201327.","journal-title":"J Appl Physiol (1985)"},{"issue":"1","key":"4607_CR19","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s13054-016-1290-9","volume":"20","author":"G Bellani","year":"2016","unstructured":"Bellani G, Grasselli G, Teggia-Droghi M, Mauri T, Coppadoro A, Brochard L, Pesenti A. Do spontaneous and mechanical breathing have similar effects on average transpulmonary and alveolar pressure? A clinical crossover study. Crit Care. 2016;20(1):142.","journal-title":"Crit Care"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-023-04607-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13054-023-04607-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-023-04607-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T22:00:51Z","timestamp":1700258451000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/s13054-023-04607-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,25]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4607"],"URL":"https:\/\/doi.org\/10.1186\/s13054-023-04607-2","relation":{},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,25]]},"assertion":[{"value":"17 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by St. Michael\u2019s Hospital Animal Care and Use Committee (ACC 482). Care and handling of the animals were performed according to the Canadian Council on Animal Care.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"JB and CS have made inventions related to neural control of mechanical ventilation that are patented. The patents are assigned to the academic institution(s) where inventions were made. The license for these patents belongs to Maquet Critical Care. Future commercial uses of this technology may provide financial benefit to JB and CS through royalties. JB and CS each own 50% of Neurovent Research Inc (NVR). NVR is a research and development company that builds the equipment and catheters for research studies. NVR has a consulting agreement with Maquet Critical Care. St-Michael\u2019s Hospital has a research agreement with Maquet Critical Care AB (Solna, Sweden) and receives royalty and overhead from this agreement. The remaining authors have no competing interests to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"325"}}