{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T11:57:43Z","timestamp":1794916663124,"version":"4.9.1"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,19]],"date-time":"2025-02-19T00:00:00Z","timestamp":1739923200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,19]],"date-time":"2025-02-19T00:00:00Z","timestamp":1739923200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100013348","name":"Innosuisse","doi-asserted-by":"crossref","award":["114.383.1 IP-LS"],"award-info":[{"award-number":["114.383.1 IP-LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      The ratio of pulse-oximetric peripheral oxygen saturation to fraction of inspired oxygen (SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      ) has been proposed as additional hypoxemia criterion in a new global definition of acute respiratory distress syndrome (ARDS). This study aims to evaluate the clinical and theoretical limitations of the SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      -ratio when using it to classify patients with ARDS and to follow disease progression.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Observational cohort study of ARDS patients from three high-resolution Intensive Care Unit databases, including our own database ICU Cockpit, MIMIC-IV (Version 3.0) and SICdb (Version 1.0.6). Patients with ARDS were identified based on the Berlin criteria or ICD 9\/10-codes. Time-matched datapoints of SpO\n                      <jats:sub>2<\/jats:sub>\n                      , FiO\n                      <jats:sub>2<\/jats:sub>\n                      and partial pressure of oxygen in arterial blood (PaO\n                      <jats:sub>2<\/jats:sub>\n                      ) were created. Severity classification followed the thresholds for SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      and PaO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      of the newly proposed global definition.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Overall, 708 ARDS patients were included in the analysis. ARDS severity was misclassified by SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      in 33% of datapoints, out of which 84% were classified as more severe. This can be partially explained by imprecision of SpO\n                      <jats:sub>2<\/jats:sub>\n                      measurement and equation used to transform SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      to PaO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2.<\/jats:sub>\n                      A high dependence of SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      -ratio on FiO\n                      <jats:sub>2<\/jats:sub>\n                      settings was found, leading to major treatment effect and limited capability for tracking change in ARDS severity, which was achieved in less than 20% of events.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      The use of SpO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      interchangeably with PaO\n                      <jats:sub>2<\/jats:sub>\n                      \/FiO\n                      <jats:sub>2<\/jats:sub>\n                      for severity classification and monitoring of ARDS is limited by its inadequate trending ability and high dependence on FiO\n                      <jats:sub>2<\/jats:sub>\n                      settings, which may influence treatment decisions and patient selection in clinical trials.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13054-025-05317-7","type":"journal-article","created":{"date-parts":[[2025,2,19]],"date-time":"2025-02-19T01:04:24Z","timestamp":1739927064000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Limitations of SpO2 \/ FiO2-ratio for classification and monitoring of acute respiratory distress syndrome\u2014an observational cohort study"],"prefix":"10.1186","volume":"29","author":[{"given":"Rolf","family":"Erlebach","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Una","family":"Pale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tilman","family":"Beck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sasa","family":"Markovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marko","family":"Seric","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sascha","family":"David","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emanuela","family":"Keller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,19]]},"reference":[{"issue":"3","key":"5317_CR1","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1164\/ajrccm\/138.3.720","volume":"138","author":"JF Murray","year":"1988","unstructured":"Murray JF, Matthay MA, Luce JM, Flick MR. An expanded definition of the adult respiratory distress syndrome. Am Rev Respir Dis. 1988;138(3):720\u20133.","journal-title":"Am Rev Respir Dis"},{"issue":"3","key":"5317_CR2","first-page":"225","volume":"20","author":"GR Bernard","year":"1994","unstructured":"Bernard GR, Artigas A, Brigham KL, Carlet J, Falke K, Hudson L, et al. Report of the American-European consensus conference on ARDS: definitions, mechanisms, relevant outcomes and clinical trial coordination. Consens Comm Intensive Care Med. 1994;20(3):225\u201332.","journal-title":"Consens Comm Intensive Care Med"},{"issue":"23","key":"5317_CR3","first-page":"2526","volume":"307","author":"ADT Force","year":"2012","unstructured":"Force ADT, Ranieri VM, Rubenfeld GD, Thompson BT, Ferguson ND, Caldwell E, et al. Acute respiratory distress syndrome: the berlin definition. JAMA. 2012;307(23):2526\u201333.","journal-title":"JAMA"},{"issue":"21","key":"5317_CR4","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1056\/NEJMoa1800385","volume":"378","author":"A Combes","year":"2018","unstructured":"Combes A, Hajage D, Capellier G, Demoule A, Lavoue S, Guervilly C, et al. Extracorporeal Membrane Oxygenation for Severe Acute Respiratory Distress Syndrome. N Engl J Med. 2018;378(21):1965\u201375.","journal-title":"N Engl J Med"},{"issue":"23","key":"5317_CR5","doi-asserted-by":"publisher","first-page":"2159","DOI":"10.1056\/NEJMoa1214103","volume":"368","author":"C Guerin","year":"2013","unstructured":"Guerin C, Reignier J, Richard JC, Beuret P, Gacouin A, Boulain T, et al. Prone positioning in severe acute respiratory distress syndrome. N Engl J Med. 2013;368(23):2159\u201368.","journal-title":"N Engl J Med"},{"issue":"18","key":"5317_CR6","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","volume":"342","author":"RG Brower","year":"2000","unstructured":"Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342(18):1301\u20138.","journal-title":"N Engl J Med."},{"issue":"1","key":"5317_CR7","doi-asserted-by":"publisher","first-page":"e40","DOI":"10.1097\/CCM.0000000000002017","volume":"45","author":"JR Feiner","year":"2017","unstructured":"Feiner JR, Weiskopf RB. Evaluating pulmonary function: an assessment of PaO2\/FIO2. Crit Care Med. 2017;45(1):e40\u20138.","journal-title":"Crit Care Med"},{"issue":"5","key":"5317_CR8","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.ajem.2014.01.020","volume":"32","author":"SB Baskin","year":"2014","unstructured":"Baskin SB, Oray NC, Yanturali S, Bayram B. The comparison of heparinized insulin syringes and safety-engineered blood gas syringes used in arterial blood gas sampling in the ED setting (randomized controlled study). Am J Emerg Med. 2014;32(5):432\u20137.","journal-title":"Am J Emerg Med"},{"issue":"1","key":"5317_CR9","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1164\/rccm.201503-0584OC","volume":"193","author":"ED Riviello","year":"2016","unstructured":"Riviello ED, Kiviri W, Twagirumugabe T, Mueller A, Banner-Goodspeed VM, Officer L, et al. Hospital incidence and outcomes of the acute respiratory distress syndrome using the kigali modification of the berlin definition. Am J Respir Crit Care Med. 2016;193(1):52\u20139.","journal-title":"Am J Respir Crit Care Med"},{"issue":"2","key":"5317_CR10","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1378\/chest.07-0617","volume":"132","author":"TW Rice","year":"2007","unstructured":"Rice TW, Wheeler AP, Bernard GR, Hayden DL, Schoenfeld DA, Ware LB, et al. Comparison of the SpO2\/FIO2 ratio and the PaO2\/FIO2 ratio in patients with acute lung injury or ARDS. Chest. 2007;132(2):410\u20137.","journal-title":"Chest"},{"key":"5317_CR11","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/978-3-030-03143-5_6","volume-title":"Sepsis management in resource-limited settings","author":"AS Neto","year":"2019","unstructured":"Neto AS, Schultz MJ, Festic E, Adhikari NKJ, Dondorp AM, Pattnaik R, et al. Ventilatory support of patients with sepsis or septic shock in resource-limited settings. In: Dondorp AM, Dunser MW, Schultz MJ, editors., et al., Sepsis management in resource-limited settings. Cham: Springer; 2019. p. 131\u201349."},{"issue":"3","key":"5317_CR12","doi-asserted-by":"publisher","first-page":"542.e9","DOI":"10.1016\/j.jcrc.2010.04.009","volume":"25","author":"RS Tripathi","year":"2010","unstructured":"Tripathi RS, Blum JM, Rosenberg AL, Tremper KK. Pulse oximetry saturation to fraction inspired oxygen ratio as a measure of hypoxia under general anesthesia and the influence of positive end-expiratory pressure. J Crit Care. 2010;25(3):542.e9-542.e13. https:\/\/doi.org\/10.1016\/j.jcrc.2010.04.009.","journal-title":"J Crit Care"},{"issue":"4","key":"5317_CR13","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1097\/CCM.0b013e31819cefa9","volume":"37","author":"PP Pandharipande","year":"2009","unstructured":"Pandharipande PP, Shintani AK, Hagerman HE, St Jacques PJ, Rice TW, Sanders NW, et al. Derivation and validation of Spo2\/Fio2 ratio to impute for Pao2\/Fio2 ratio in the respiratory component of the sequential organ failure assessment score. Crit Care Med. 2009;37(4):1317\u201321.","journal-title":"Crit Care Med"},{"issue":"3","key":"5317_CR14","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1016\/j.jcrc.2015.02.007","volume":"30","author":"MF Schmidt","year":"2015","unstructured":"Schmidt MF, Gernand J, Kakarala R. The use of the pulse oximetric saturation to fraction of inspired oxygen ratio in an automated acute respiratory distress syndrome screening tool. J Crit Care. 2015;30(3):486\u201390.","journal-title":"J Crit Care"},{"issue":"1","key":"5317_CR15","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1164\/rccm.202303-0558WS","volume":"209","author":"MA Matthay","year":"2024","unstructured":"Matthay MA, Arabi Y, Arroliga AC, Bernard G, Bersten AD, Brochard LJ, et al. A new global definition of acute respiratory distress syndrome. Am J Respir Crit Care Med. 2024;209(1):37\u201347.","journal-title":"Am J Respir Crit Care Med"},{"issue":"6","key":"5317_CR16","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1378\/chest.15-0169","volume":"148","author":"W Chen","year":"2015","unstructured":"Chen W, Janz DR, Shaver CM, Bernard GR, Bastarache JA, Ware LB. Clinical characteristics and outcomes are similar in ARDS diagnosed by oxygen saturation\/Fio2 ratio compared with Pao2\/Fio2 ratio. Chest. 2015;148(6):1477\u201383.","journal-title":"Chest"},{"issue":"4","key":"5317_CR17","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1007\/s00134-024-07383-x","volume":"50","author":"F Qian","year":"2024","unstructured":"Qian F, van den Boom W, See KC. The new global definition of acute respiratory distress syndrome: insights from the MIMIC-IV database. Intensive Care Med. 2024;50(4):608\u20139.","journal-title":"Intensive Care Med"},{"issue":"7","key":"5317_CR18","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1093\/jamia\/ocac064","volume":"29","author":"JM Boss","year":"2022","unstructured":"Boss JM, Narula G, Straessle C, Willms J, Azzati J, Brodbeck D, et al. ICU Cockpit: a platform for collecting multimodal waveform data, AI-based computational disease modeling and real-time decision support in the intensive care unit. J Am Med Inform Assoc. 2022;29(7):1286\u201391.","journal-title":"J Am Med Inform Assoc"},{"key":"5317_CR19","unstructured":"Johnson A, Bulgarelli L, Pollard T, Gow B, Moody B, Horng S, et al. MIMIC-IV."},{"issue":"1","key":"5317_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41597-022-01899-x","volume":"10","author":"AEW Johnson","year":"2023","unstructured":"Johnson AEW, Bulgarelli L, Shen L, Gayles A, Shammout A, Horng S, et al. MIMIC-IV, a freely accessible electronic health record dataset. Sci Data. 2023;10(1):1.","journal-title":"Sci Data"},{"key":"5317_CR21","doi-asserted-by":"crossref","unstructured":"Rodemund N, Kokoefer, A., Wernly, B., & Cozowicz, C. Salzburg intensive care database (SICdb), a freely accessible intensive care database (version 1.0.6). In: PhysioNet, editor. 2023.","DOI":"10.1007\/s00134-023-07046-3"},{"issue":"6","key":"5317_CR22","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1007\/s00134-023-07046-3","volume":"49","author":"N Rodemund","year":"2023","unstructured":"Rodemund N, Wernly B, Jung C, Cozowicz C, Kok\u00f6fer A. The salzburg intensive care database (SICdb): an openly available critical care dataset. Intensive Care Med. 2023;49(6):700\u20132.","journal-title":"Intensive Care Med"},{"issue":"23","key":"5317_CR23","doi-asserted-by":"publisher","first-page":"E215","DOI":"10.1161\/01.CIR.101.23.e215","volume":"101","author":"AL Goldberger","year":"2000","unstructured":"Goldberger AL, Amaral LA, Glass L, Hausdorff JM, Ivanov PC, Mark RG, et al. PhysioBank, physiotoolkit, and physionet: components of a new research resource for complex physiologic signals. Circulation. 2000;101(23):E215\u201320.","journal-title":"Circulation"},{"issue":"8","key":"5317_CR24","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1001\/jama.2016.0291","volume":"315","author":"G Bellani","year":"2016","unstructured":"Bellani G, Laffey JG, Pham T, Fan E, Brochard L, Esteban A, et al. Epidemiology, patterns of care, and mortality for patients with acute respiratory distress syndrome in intensive care units in 50 countries. JAMA. 2016;315(8):788\u2013800.","journal-title":"JAMA"},{"issue":"11","key":"5317_CR25","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1097\/00003246-198911000-00006","volume":"17","author":"F Laghi","year":"1989","unstructured":"Laghi F, Siegel JH, Rivkind AI, Chiarla C, DeGaetano A, Blevins S, et al. Respiratory index\/pulmonary shunt relationship: quantification of severity and prognosis in the post-traumatic adult respiratory distress syndrome. Crit Care Med. 1989;17(11):1121\u20138.","journal-title":"Crit Care Med"},{"issue":"6","key":"5317_CR26","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1378\/chest.75.6.748","volume":"75","author":"HF Helmholz Jr","year":"1979","unstructured":"Helmholz HF Jr. The abbreviated alveolar air equation. Chest. 1979;75(6):748.","journal-title":"Chest"},{"issue":"2","key":"5317_CR27","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1093\/bja\/aep140","volume":"103","author":"A Kathirgamanathan","year":"2009","unstructured":"Kathirgamanathan A, McCahon RA, Hardman JG. Indices of pulmonary oxygenation in pathological lung states: an investigation using high-fidelity, computational modelling. Br J Anaesth. 2009;103(2):291\u20137.","journal-title":"Br J Anaesth"},{"issue":"3","key":"5317_CR28","first-page":"599","volume":"46","author":"JW Severinghaus","year":"1979","unstructured":"Severinghaus JW. Simple, accurate equations for human blood O2 dissociation computations. J Appl Physiol Respir Environ Exerc Physiol. 1979;46(3):599\u2013602.","journal-title":"J Appl Physiol Respir Environ Exerc Physiol"},{"issue":"12","key":"5317_CR29","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1097\/00003246-198812000-00014","volume":"16","author":"RD Cane","year":"1988","unstructured":"Cane RD, Shapiro BA, Templin R, Walther K. Unreliability of oxygen tension-based indices in reflecting intrapulmonary shunting in critically ill patients. Crit Care Med. 1988;16(12):1243\u20135.","journal-title":"Crit Care Med"},{"issue":"12","key":"5317_CR30","doi-asserted-by":"publisher","first-page":"2245","DOI":"10.1007\/s00134-018-5413-4","volume":"44","author":"L Gattinoni","year":"2018","unstructured":"Gattinoni L, Vassalli F, Romitti F. Benefits and risks of the P\/F approach. Intensive Care Med. 2018;44(12):2245\u20137.","journal-title":"Intensive Care Med"},{"issue":"4","key":"5317_CR31","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1164\/rccm.202109-2163OC","volume":"205","author":"VM Ranieri","year":"2022","unstructured":"Ranieri VM, Tonetti T, Navalesi P, Nava S, Antonelli M, Pesenti A, et al. High-flow nasal oxygen for severe hypoxemia: oxygenation response and outcome in patients with COVID-19. Am J Respir Crit Care Med. 2022;205(4):431\u20139.","journal-title":"Am J Respir Crit Care Med"},{"issue":"8","key":"5317_CR32","doi-asserted-by":"publisher","first-page":"e694","DOI":"10.1097\/CCM.0000000000005559","volume":"50","author":"Y Shen","year":"2022","unstructured":"Shen Y, Zhu L, Yan J. Stability of Spo2\/Fio2 and respiratory rate-oxygenation indexes in critical respiratory disorders. Crit Care Med. 2022;50(8):e694\u20135.","journal-title":"Crit Care Med"},{"issue":"1","key":"5317_CR33","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1186\/s13054-015-0984-8","volume":"19","author":"A Jubran","year":"2015","unstructured":"Jubran A. Pulse oximetry. Critical Care. 2015;19(1):272.","journal-title":"Critical Care"},{"issue":"3","key":"5317_CR34","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1097\/00003246-200003000-00017","volume":"28","author":"P Seguin","year":"2000","unstructured":"Seguin P, Le Rouzo A, Tanguy M, Guillou YM, Feuillu A, Malledant Y. Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit. Crit Care Med. 2000;28(3):703\u20136.","journal-title":"Crit Care Med"},{"issue":"4","key":"5317_CR35","doi-asserted-by":"publisher","first-page":"R67","DOI":"10.1186\/cc2339","volume":"7","author":"GD Perkins","year":"2003","unstructured":"Perkins GD, McAuley DF, Giles S, Routledge H, Gao F. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Critical Care. 2003;7(4):R67.","journal-title":"Critical Care"},{"issue":"10","key":"5317_CR36","doi-asserted-by":"publisher","first-page":"1606","DOI":"10.1007\/s001340101064","volume":"27","author":"A Van de Louw","year":"2001","unstructured":"Van de Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, Brochard L. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27(10):1606\u201313.","journal-title":"Intensive Care Med"},{"issue":"5","key":"5317_CR37","doi-asserted-by":"publisher","first-page":"565","DOI":"10.4187\/respcare.10582","volume":"68","author":"MA Blanchet","year":"2023","unstructured":"Blanchet MA, Mercier G, Delobel A, Nayet E, Bouchard PA, Simard S, et al. Accuracy of multiple pulse oximeters in stable critically Ill patients. Respir Care. 2023;68(5):565\u201374.","journal-title":"Respir Care"},{"issue":"6","key":"5317_CR38","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1378\/chest.97.6.1420","volume":"97","author":"A Jubran","year":"1990","unstructured":"Jubran A, Tobin MJ. Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. Chest. 1990;97(6):1420\u20135.","journal-title":"Chest"},{"issue":"3","key":"5317_CR39","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1111\/j.1365-2044.1991.tb09411.x","volume":"46","author":"RK Webb","year":"1991","unstructured":"Webb RK, Ralston AC, Runciman WB. Potential errors in pulse oximetry: II. Effects of changes in saturation and signal quality. Anaesthesia. 1991;46(3):207\u201312.","journal-title":"Anaesthesia."},{"issue":"1","key":"5317_CR40","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/j.1365-2044.1991.tb09303.x","volume":"46","author":"DG Clayton","year":"2007","unstructured":"Clayton DG, Webb RK, Ralston AC, Duthie D, Runciman WB. A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion. Anaesthesia. 2007;46(1):3\u201310.","journal-title":"Anaesthesia"},{"issue":"2","key":"5317_CR41","doi-asserted-by":"publisher","first-page":"R11","DOI":"10.1186\/cc341","volume":"3","author":"A Jubran","year":"1999","unstructured":"Jubran A. Pulse oximetry. Critical Care. 1999;3(2):R11\u20137.","journal-title":"Critical Care"},{"issue":"3","key":"5317_CR42","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1183\/20734735.001415","volume":"11","author":"JA Collins","year":"2015","unstructured":"Collins JA, Rudenski A, Gibson J, Howard L, O\u2019Driscoll R. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve. Breathe. 2015;11(3):194\u2013201.","journal-title":"Breathe"},{"issue":"11","key":"5317_CR43","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1056\/NEJMoa1916431","volume":"382","author":"L Barrot","year":"2020","unstructured":"Barrot L, Asfar P, Mauny F, Winiszewski H, Montini F, Badie J, et al. Liberal or conservative oxygen therapy for acute respiratory distress syndrome. N Engl J Med. 2020;382(11):999\u20131008.","journal-title":"N Engl J Med"},{"issue":"11","key":"5317_CR44","first-page":"989","volume":"382","author":"D Mackle","year":"2019","unstructured":"Mackle D, Bellomo R, Bailey M, Beasley R, Deane A, Eastwood G, Finfer S, Freebairn R, King V, Linke N, Litton E. Conservative oxygen therapy during mechanical ventilation in the ICU. New England J Med. 2019;382(11):989\u201398.","journal-title":"New England J Med"},{"issue":"14","key":"5317_CR45","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJMoa2032510","volume":"384","author":"OL Schjorring","year":"2021","unstructured":"Schjorring OL, Klitgaard TL, Perner A, Wetterslev J, Lange T, Siegemund M, et al. Lower or higher oxygenation targets for acute hypoxemic respiratory failure. N Engl J Med. 2021;384(14):1301\u201311.","journal-title":"N Engl J Med"},{"issue":"19","key":"5317_CR46","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1056\/NEJMoa2208415","volume":"387","author":"MW Semler","year":"2022","unstructured":"Semler MW, Casey JD, Lloyd BD, Hastings PG, Hays MA, Stollings JL, et al. Oxygen-saturation targets for critically Ill adults receiving mechanical ventilation. N Engl J Med. 2022;387(19):1759\u201369.","journal-title":"N Engl J Med"},{"issue":"15","key":"5317_CR47","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1001\/jama.2016.11993","volume":"316","author":"M Girardis","year":"2016","unstructured":"Girardis M, Busani S, Damiani E, Donati A, Rinaldi L, Marudi A, et al. Effect of conservative vs conventional oxygen therapy on mortality among patients in an intensive care unit: the oxygen-ICU randomized clinical trial. JAMA. 2016;316(15):1583\u20139.","journal-title":"JAMA"},{"issue":"9596","key":"5317_CR48","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1016\/S0140-6736(07)61602-X","volume":"370","author":"E von Elm","year":"2007","unstructured":"von Elm E, Altman DG, Egger M, Pocock SJ, Gotzsche PC, Vandenbroucke JP, Initiative S. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Lancet. 2007;370(9596):1453\u20137.","journal-title":"Lancet"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-025-05317-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13054-025-05317-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13054-025-05317-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T12:03:22Z","timestamp":1762344202000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/s13054-025-05317-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,19]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5317"],"URL":"https:\/\/doi.org\/10.1186\/s13054-025-05317-7","relation":{},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,19]]},"assertion":[{"value":"27 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective observational study involving human data was in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The collection and usage of data from ICU cockpit was approved by the local ethics commission (Cantonal Ethics Commission of Zurich, BASEC Nr. PB_2016-01101). Access to MIMIC-IV and SICdb was provided through PhysioNet [\n                      \n                      ] after a credential process including training and signing a data use agreement.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The study is part of a research project funded by the Swiss Innovation Agency (Innosuisse) in collaboration with Hamilton Medical AG (Switzerland). The project uses high resolution data to improve early recognition of ARDS and studies the impact of ventilator settings on gas exchange.\u00a0The authors declare that they received funding solely from Innosuisse and did not receive any financial support from Hamilton Medical AG. Hamilton Medical AG had no role in the conduction of the study or writing of the report.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"82"}}