{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T06:39:36Z","timestamp":1793255976313,"version":"4.5.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,11,28]],"date-time":"2017-11-28T00:00:00Z","timestamp":1511827200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2017,11,28]],"date-time":"2017-11-28T00:00:00Z","timestamp":1511827200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Union's Seventh Framework Programme FP7","award":["306088"],"award-info":[{"award-number":["306088"]}]},{"DOI":"10.13039\/100000054","name":"National Cancer Institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000869","name":"Susan G. Komen for the Cure","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000869","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Breast Cancer Res"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1186\/s13058-017-0917-3","type":"journal-article","created":{"date-parts":[[2017,11,28]],"date-time":"2017-11-28T12:04:55Z","timestamp":1511870695000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["Influence of breast compression pressure on the performance of population-based mammography screening"],"prefix":"10.1186","volume":"19","author":[{"given":"Katharina","family":"Holland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ioannis","family":"Sechopoulos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ritse M.","family":"Mann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerard J.","family":"den Heeten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla H.","family":"van Gils","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nico","family":"Karssemeijer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,11,28]]},"reference":[{"key":"917_CR1","doi-asserted-by":"publisher","first-page":"868","DOI":"10.1016\/j.ejrad.2011.02.027","volume":"81","author":"B Chen","year":"2012","unstructured":"Chen B, Wang Y, Sun X, et al. Analysis of patient dose in full field digital mammography. Eur J Radiol. 2012;81:868\u201372.","journal-title":"Eur J Radiol."},{"key":"917_CR2","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1186\/1475-925X-9-73","volume":"9","author":"J Heine","year":"2010","unstructured":"Heine J, Cao K, Thomas JA. Effective radiation attenuation calibration for breast density: compression thickness influences and correction. Biomed Eng Online. 2010;9:73.","journal-title":"Biomed Eng Online."},{"key":"917_CR3","unstructured":"Kopans DB. Breast imaging. 3rd ed. Lippincott Williams & Wilkins; 2007. pp. 254\u20136."},{"key":"917_CR4","doi-asserted-by":"publisher","first-page":"4464","DOI":"10.1118\/1.2977600","volume":"35","author":"RS Saunders Jr","year":"2008","unstructured":"Saunders Jr RS, Samei E. The effect of breast compression on mass conspicuity in digital mammography. Med Phys. 2008;35:4464\u201373.","journal-title":"Med Phys."},{"key":"917_CR5","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.ejrad.2014.12.012","volume":"84","author":"W Branderhorst","year":"2015","unstructured":"Branderhorst W, de Groot JE, Highnam R, et al. Mammographic compression\u2014a need for mechanical standardization. Eur J Radiol. 2015;84:596\u2013602.","journal-title":"Eur J Radiol."},{"key":"917_CR6","doi-asserted-by":"publisher","first-page":"362","DOI":"10.2214\/AJR.08.2114","volume":"94","author":"RE Hendrick","year":"2010","unstructured":"Hendrick RE, Pisano ED, Averbukh A, et al. Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening trial. AJR Am J Roentgenol. 2010;94:362\u20139.","journal-title":"AJR Am J Roentgenol."},{"key":"917_CR7","doi-asserted-by":"publisher","first-page":"P10","DOI":"10.1186\/bcr2962","volume":"13","author":"D O\u2019Leary","year":"2011","unstructured":"O\u2019Leary D, Grand T, Rainford L. Image quality and compression force: the forgotten link in optimisation of digital mammography? Breast Cancer Res. 2011;13:P10.","journal-title":"Breast Cancer Res."},{"key":"917_CR8","doi-asserted-by":"publisher","first-page":"20110596","DOI":"10.1259\/bjr.20110596","volume":"86","author":"CE Mercer","year":"2013","unstructured":"Mercer CE, Hogg P, Lawson R, Diffey J, Denton ERE. Practitioner compression force variability in mammography: a preliminary study. Br J Radiol. 2013;86:20110596.","journal-title":"Br J Radiol."},{"key":"917_CR9","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.radi.2014.07.004","volume":"21","author":"CE Mercer","year":"2015","unstructured":"Mercer CE, Szczepura K, Kelly J, et al. A 6-year study of mammographic compression force: practitioner variability within and between screening sites. Radiography. 2015;21:68\u201373.","journal-title":"Radiography."},{"key":"917_CR10","doi-asserted-by":"publisher","first-page":"20160770","DOI":"10.1259\/bjr.20160770","volume":"90","author":"GG Waade","year":"2017","unstructured":"Waade GG, Moshina N, S\u00e6bu\u00f8deg\u00e5rd S, Hogg P, Hofvind S. Compression forces used in the Norwegian breast cancer screening program. Br J Radiol. 2017;90:20160770.","journal-title":"Br J Radiol."},{"key":"917_CR11","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.radi.2006.03.001","volume":"13","author":"B Davey","year":"2007","unstructured":"Davey B. Pain during mammography: possible risk factors and ways to alleviate pain. Radiography. 2007;13:229\u201334.","journal-title":"Radiography."},{"key":"917_CR12","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1148\/radiology.214.2.r00fe23547","volume":"214","author":"JR Dullum","year":"2000","unstructured":"Dullum JR, Lewis EC, Mayer JA. Rates and correlates of discomfort associated with mammography. Radiology. 2000;214:547\u201352.","journal-title":"Radiology."},{"key":"917_CR13","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/0304-3959(94)90163-5","volume":"56","author":"FJ Keefe","year":"1994","unstructured":"Keefe FJ, Hauck ER, Egert J, Rimer B, Kornguth P. Mammography pain and discomfort: a cognitive-behavioral perspective. Pain. 1994;56:247\u201360.","journal-title":"Pain."},{"key":"917_CR14","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.breast.2013.03.003","volume":"22","author":"P Whelehan","year":"2013","unstructured":"Whelehan P, Evans A, Wells M, Macgillivray S. The effect of mammography pain on repeat participation in breast cancer screening: a systematic review. Breast. 2013;22:389\u201394.","journal-title":"Breast."},{"key":"917_CR15","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.ejrad.2014.12.005","volume":"84","author":"JE de Groot","year":"2015","unstructured":"de Groot JE, Branderhorst W, Grimbergen CA, den Heeten GJ, Broeders MJM. Towards personalized compression in mammography: a comparison study between pressure- and force-standardization. Eur J Radiol. 2015;84:384\u201391.","journal-title":"Eur J Radiol."},{"key":"917_CR16","doi-asserted-by":"publisher","first-page":"081901","DOI":"10.1118\/1.4812418","volume":"40","author":"JE de Groot","year":"2013","unstructured":"de Groot JE, Broeders MJM, Branderhorst W, den Heeten GJ, Grimbergen CA. A novel approach to mammographic breast compression: improved standardization and reduced discomfort by controlling pressure instead of force. Med Phys. 2013;40:081901.","journal-title":"Med Phys."},{"key":"917_CR17","doi-asserted-by":"crossref","unstructured":"Perry N, Broeders M, de Wolf C, T\u00f6rnberg S, Holland R, Karsa LV. European guidelines for quality assurance in breast cancer screening and diagnosis. 4th ed. Office for Official Publications of the European Communities; 2008. p. 172.","DOI":"10.1093\/annonc\/mdm481"},{"issue":"3","key":"917_CR18","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1053\/sroe.2001.25118","volume":"36","author":"RJ Brenner","year":"2001","unstructured":"Brenner RJ. Asymmetric densities of the breast: strategies for imaging evaluation. Semin Roentgenol. 2001;36(3):201\u201316.","journal-title":"Semin Roentgenol"},{"key":"917_CR19","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1148\/rg.2016150205","volume":"36","author":"CS Giess","year":"2016","unstructured":"Giess CS, Chikarmane SA, Sippo DA, Birdwell RL. Breast MR imaging for equivocal mammographic findings: help or hindrance? Radiographics. 2016;36:943\u201358.","journal-title":"Radiographics."},{"key":"917_CR20","volume-title":"Diagnostic breast imaging","author":"SH Heywang-Koebrunner","year":"2014","unstructured":"Heywang-Koebrunner SH, Schreer I, Barter S. Diagnostic breast imaging. 3rd ed. Stuttgart, Germany: Georg Thieme Verlag; 2014.","edition":"3"},{"key":"917_CR21","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1109\/TMI.2004.827477","volume":"23","author":"PR Snoeren","year":"2004","unstructured":"Snoeren PR, Karssemeijer N. Thickness correction of mammographic images by means of a global parameter model of the compressed breast. IEEE Trans Med Imaging. 2004;23:799\u2013806.","journal-title":"IEEE Trans Med Imaging."},{"key":"917_CR22","first-page":"4040","volume":"44","author":"W Branderhorst","year":"2017","unstructured":"Branderhorst W, de Groot JE, van Lier MGJTB, Highnam RP, den Heeten GJ, Grimbergen CA. Technical note: validation of two methods to determine contact area between breast and compression paddle in mammography. Medicalphysics. 2017;44:4040\u20134.","journal-title":"Medicalphysics."},{"key":"917_CR23","doi-asserted-by":"crossref","unstructured":"Holland K, Sechopoulos I, den Heeten GJ, Mann RM, Karssemeijer N. Performance of breast cancer screening depends on mammographic compression. In: Tingberg A et al., editors. Breast imaging. Cham: Springer; 2016: p. 183\u20139.","DOI":"10.1007\/978-3-319-41546-8_24"},{"key":"917_CR24","doi-asserted-by":"publisher","first-page":"673","DOI":"10.7326\/M14-1465","volume":"162","author":"K Kerlikowske","year":"2015","unstructured":"Kerlikowske K, Zhu W, Tosteson ANA, et al. Identifying women with dense breasts at high risk for interval cancer: a cohort study. Ann Intern Med. 2015;162:673\u201381.","journal-title":"Ann Intern Med."},{"key":"917_CR25","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1148\/radiol.2015150733","volume":"278","author":"MV Prummel","year":"2016","unstructured":"Prummel MV, Muradali D, Shumak R, et al. Digital compared with screen-film mammography: measures of diagnostic accuracy among women screened in the Ontario Breast Screening Program. Radiology. 2016;278:365\u201373.","journal-title":"Radiology."},{"key":"917_CR26","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/s10549-016-4090-7","volume":"162","author":"JOP Wanders","year":"2017","unstructured":"Wanders JOP, Holland K, Veldhuis WB, et al. Volumetric breast density affects performance of digital screening mammography. Breast Cancer Research Treatment. 2017;162:95\u2013103.","journal-title":"Breast Cancer Research Treatment."},{"key":"917_CR27","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1093\/jnci\/djn224","volume":"100","author":"S Hofvind","year":"2008","unstructured":"Hofvind S, Vacek PM, Skelly J, Weaver DL, Geller BM. Comparing screening mammography for early breast cancer detection in Vermont and Norway. J Natl Cancer Inst. 2008;100:1082\u201391.","journal-title":"J Natl Cancer Inst."},{"key":"917_CR28","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.acra.2013.10.009","volume":"21","author":"DR Busch","year":"2014","unstructured":"Busch DR, Choe R, Durduran T, et al. Blood flow reduction in breast tissue due to mammographic compression. Acad Radiol. 2014;21:151\u201361.","journal-title":"Acad Radiol."},{"key":"917_CR29","doi-asserted-by":"publisher","first-page":"16064","DOI":"10.1364\/OE.16.016064","volume":"16","author":"S Carp","year":"2008","unstructured":"Carp S, Selb J, Fang Q, et al. Dynamic functional and mechanical response of breast tissue to compression. Opt Express. 2008;16:16064\u201378.","journal-title":"Opt Express."},{"key":"917_CR30","doi-asserted-by":"crossref","unstructured":"Highnam R, Brady M. Mammographic image analysis. Chapter 9. Kluwer Academic Publishers; 1999. p. 159.","DOI":"10.1007\/978-94-011-4613-5"},{"key":"917_CR31","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1007\/s10549-017-4214-8","volume":"163","author":"N Moshina","year":"2017","unstructured":"Moshina N, S\u00e6bu\u00f8deg\u00e5rd S, Hofvind S. Is breast compression associated with breast cancer detection and other early performance measures in a population-based breast cancer screening program? Breast Cancer Res Treat. 2017;163:605\u201313.","journal-title":"Breast Cancer Res Treat."},{"key":"917_CR32","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1258\/ar.2012.120238","volume":"53","author":"M Dustler","year":"2012","unstructured":"Dustler M, Andersson I, Brorson H, et al. Breast compression in mammography: pressure distribution patterns. Acta Radiol. 2012;53:973\u201380.","journal-title":"Acta Radiol."}],"container-title":["Breast Cancer Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13058-017-0917-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13058-017-0917-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13058-017-0917-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,15]],"date-time":"2020-05-15T13:35:09Z","timestamp":1589549709000},"score":1,"resource":{"primary":{"URL":"https:\/\/breast-cancer-research.biomedcentral.com\/articles\/10.1186\/s13058-017-0917-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,28]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,12]]}},"alternative-id":["917"],"URL":"https:\/\/doi.org\/10.1186\/s13058-017-0917-3","relation":{},"ISSN":["1465-542X"],"issn-type":[{"value":"1465-542X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,28]]},"assertion":[{"value":"20 May 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Written informed consent was not required for this study as women automatically consent to the use of their anonymized data for scientific purposes by participating in screening unless they object. A waiver from the research ethics committee of the Radboud University Medical Center was obtained to use the anonymized images.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"IS has a research agreement and speaking agreement with Siemens AG, and a research agreement with Toshiba Medical Systems Corporation. RMM has a research agreement with Siemens AG, Seno Medical Instruments Inc., and Identification solutions Inc. GJdH is a founder and employee of Sigmascreening. CHvG reports non-financial support from Volpara Health Technologies\u00a0outside the submitted work. NK is a shareholder and consultant to Volpara Health Technologies, a director and shareholder of ScreenPoint Medical, and a shareholder and consultant to Qview Medical. KH declares that she has no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher's Note"}}],"article-number":"126"}}