{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T07:26:49Z","timestamp":1793086009407,"version":"4.5.0"},"reference-count":83,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T00:00:00Z","timestamp":1592870400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T00:00:00Z","timestamp":1592870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Advanced Bionics"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Trials"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Prospective research in the field of cochlear implants is hampered by methodological issues and small sample sizes. The ELEPHANT study presents an alternative clinical trial design with a daily randomized approach evaluating individualized tonotopical fitting of a cochlear implant (CI).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A single-blinded, daily-randomized clinical trial will be implemented to evaluate a new imaging-based CI mapping strategy. A minimum of 20 participants will be included from the start of the rehabilitation process with a 1-year follow-up period. Based on a post-operative cone beam CT scan (CBCT), mapping of electrical input will be aligned to natural place-pitch arrangement in the individual cochlea. The CI\u2019s frequency allocation table will be adjusted to match the electrical stimulation of frequencies as closely as possible to corresponding acoustic locations in the cochlea. A randomization scheme will be implemented whereby the participant, blinded to the intervention allocation, crosses over between the experimental and standard fitting program on a daily basis, and thus effectively acts as his own control, followed by a period of free choice between both maps to incorporate patient preference. With this new approach the occurrence of a first-order carryover effect and a limited sample size is addressed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>The experimental fitting strategy is thought to give rise to a steeper learning curve, result in better performance in challenging listening situations, improve sound quality, better complement residual acoustic hearing in the contralateral ear and be preferred by recipients of a CI. Concurrently, the suitability of the novel trial design will be considered in investigating these hypotheses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>\n                      ClinicalTrials.gov:\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03892941\">NCT03892941<\/jats:ext-link>\n                      . Registered 27 March 2019.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13063-020-04469-x","type":"journal-article","created":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T07:03:07Z","timestamp":1592895787000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Evaluating hearing performance with cochlear implants within the same patient using daily randomization and imaging-based fitting - The ELEPHANT study"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7633-6243","authenticated-orcid":false,"given":"L. J. G.","family":"Lambriks","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"van Hoof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. A.","family":"Debruyne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Janssen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Chalupper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. A.","family":"van der Heijden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. R.","family":"Hof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. A.","family":"Hellingman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. L. J.","family":"George","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. M. J.","family":"Devocht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,23]]},"reference":[{"key":"4469_CR1","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","volume":"352","author":"BS Wilson","year":"1991","unstructured":"Wilson BS, Finley CC, Lawson DT, Wolford RD, Eddington DK. Rabinowitz WM. Better speech recognition with cochlear implants. Nature. 1991;352:236.","journal-title":"Nature"},{"key":"4469_CR2","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1109\/TBME.2017.2718939","volume":"64","author":"F-G Zeng","year":"2017","unstructured":"Zeng F-G. Challenges in improving cochlear implant performance and accessibility. IEEE Trans Biomed Eng. 2017;64:1662\u20134.","journal-title":"IEEE Trans Biomed Eng"},{"key":"4469_CR3","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.otc.2011.08.023","volume":"45","author":"MK Cosetti","year":"2012","unstructured":"Cosetti MK, Waltzman SB. Outcomes in cochlear implantation: variables affecting performance in adults and children. Otolaryngol Clin North Am. 2012;45:155\u201371.","journal-title":"Otolaryngol Clin North Am"},{"key":"4469_CR4","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.wjorl.2017.12.010","volume":"3","author":"DB Pisoni","year":"2017","unstructured":"Pisoni DB, Kronenberger WG, Harris MS, Moberly AC. Three challenges for future research on cochlear implants. World J Otorhinolaryngol Neck Surg. 2017;3:240\u201354.","journal-title":"World J Otorhinolaryngol Neck Surg"},{"key":"4469_CR5","doi-asserted-by":"crossref","first-page":"3019","DOI":"10.1044\/2017_JSLHR-H-17-0035","volume":"60","author":"MF Dorman","year":"2017","unstructured":"Dorman MF, Gifford RH. Speech understanding in complex listening environments by listeners fit with cochlear implants. J Speech, Lang Hear Res. 2017;60:3019\u201326.","journal-title":"J Speech, Lang Hear Res"},{"key":"4469_CR6","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1097\/MAO.0000000000001821","volume":"39","author":"JPM Peters","year":"2018","unstructured":"Peters JPM, Wendrich AW, van Eijl RHM, Rhebergen KS, Versnel H, Grolman W. The sound of a cochlear implant investigated in patients with single-sided deafness and a cochlear implant. Otol Neurotol. 2018;39:707\u201314.","journal-title":"Otol Neurotol"},{"key":"4469_CR7","doi-asserted-by":"crossref","unstructured":"Nad\u00e8ge C, Val\u00e9rie G, Laura F, H\u00e9l\u00e8ne D-B, Vanina B, Olivier D, et al. The cost of cochlear implantation: a review of methodological considerations. Int J Otolaryngol. 2011;2011:1\u201313.","DOI":"10.1155\/2011\/210838"},{"key":"4469_CR8","doi-asserted-by":"crossref","first-page":"e660","DOI":"10.1097\/MAO.0000000000001909","volume":"39","author":"B Agabigum","year":"2018","unstructured":"Agabigum B, Mir A, Arianpour K, Svider PF, Walsh EM, Hong RS. Evolving trends in cochlear implantation: a critical look at the older population. Otol Neurotol. 2018;39:e660\u20134.","journal-title":"Otol Neurotol"},{"key":"4469_CR9","first-page":"237","volume":"28","author":"NR Peterson","year":"2010","unstructured":"Peterson NR, Pisoni DB, Miyamoto RT. Cochlear implants and spoken language processing abilities: review and assessment of the literature. Restor Neurol Neurosci. 2010;28:237\u201350.","journal-title":"Restor Neurol Neurosci"},{"key":"4469_CR10","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/PRS.0b013e318219c171","volume":"128","author":"PB Burns","year":"2011","unstructured":"Burns PB, Rohrich RJ, Chung KC. The levels of evidence and their role in evidence-based medicine. Plast Reconstr Surg. 2011;128:305.","journal-title":"Plast Reconstr Surg"},{"key":"4469_CR11","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1136\/emj.20.2.164","volume":"20","author":"J Kendall","year":"2003","unstructured":"Kendall J. Designing a research project: randomised controlled trials and their principles. Emerg Med J. 2003;20:164.","journal-title":"Emerg Med J"},{"key":"4469_CR12","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1017\/S0022215100138101","volume":"111","author":"KW Ah-See","year":"1997","unstructured":"Ah-See KW, Molony NC, Maran AGD. Trends in randomized controlled trials in ENT: a 30-year review. J Laryngol Otol. 1997;111:611\u20133.","journal-title":"J Laryngol Otol"},{"key":"4469_CR13","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1001\/jamaoto.2013.1744","volume":"139","author":"JM Gaylor","year":"2013","unstructured":"Gaylor JM, Raman G, Chung M, Lee J, Rao M, Lau J, et al. Cochlear implantation in adults: a systematic review and meta-analysis. JAMA Otolaryngol Neck Surg. 2013;139:265\u201372.","journal-title":"JAMA Otolaryngol Neck Surg"},{"key":"4469_CR14","doi-asserted-by":"crossref","unstructured":"Kraaijenga VJC, Ramakers GGJ, Smulders YE, van Zon A, Free RH, Frijns JHM, et al. No difference in behavioral and self-reported outcomes for simultaneous and sequential bilateral cochlear implantation: evidence from a multicenter randomized controlled trial. Front Neurosci. 2019;13:1\u201317.","DOI":"10.3389\/fnins.2019.00054"},{"key":"4469_CR15","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/MAO.0b013e318278506d","volume":"34","author":"J van Schoonhoven","year":"2013","unstructured":"van Schoonhoven J, Sparreboom M, van Zanten BGA, Scholten RJPM, Mylanus EAM, Dreschler WA, et al. The effectiveness of bilateral cochlear implants for severe-to-profound deafness in adults: a systematic review. Otol Neurotol. 2013;34:190\u20138.","journal-title":"Otol Neurotol"},{"key":"4469_CR16","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1056\/NEJM199301283280403","volume":"328","author":"NL Cohen","year":"1993","unstructured":"Cohen NL, Waltzman SB, Fisher SG. A prospective, randomized study of cochlear implants. The Department of Veterans Affairs Cochlear Implant Study Group. N Engl J Med. 1993;328:233\u20137.","journal-title":"N Engl J Med"},{"key":"4469_CR17","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1001\/jamaoto.2015.3305","volume":"142","author":"YE Smulders","year":"2016","unstructured":"Smulders YE, van Zon A, Stegeman I, Rinia AB, Van Zanten GA, Stokroos RJ, et al. Comparison of bilateral and unilateral cochlear implantation in adults: a randomized clinical trial. JAMA Otolaryngol Neck Surg. 2016;142:249\u201356.","journal-title":"JAMA Otolaryngol Neck Surg"},{"key":"4469_CR18","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1097\/MAO.0000000000000541","volume":"35","author":"CA Buchman","year":"2014","unstructured":"Buchman CA, Dillon MT, King ER, Adunka MC, Adunka OF, Pillsbury HC. Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol. 2014;35:1773\u20139.","journal-title":"Otol Neurotol"},{"key":"4469_CR19","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1080\/14670100.2016.1244033","volume":"17","author":"MT Dillon","year":"2016","unstructured":"Dillon MT, Buss E, King ER, Deres EJ, Obarowski SN, Anderson ML, et al. Comparison of two cochlear implant coding strategies on speech perception. Cochlear Implants Int. 2016;17:263\u201370.","journal-title":"Cochlear Implants Int"},{"key":"4469_CR20","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1097\/MAO.0000000000000301","volume":"35","author":"DB Koch","year":"2014","unstructured":"Koch DB, Quick A, Osberger MJ, Saoji A, Litvak L. Enhanced hearing in noise for cochlear implant recipients: clinical trial results for a commercially available speech-enhancement strategy. Otol Neurotol. 2014;35:803\u20139.","journal-title":"Otol Neurotol"},{"key":"4469_CR21","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1097\/MAO.0b013e31822a97f4","volume":"32","author":"D Riss","year":"2011","unstructured":"Riss D, Hamzavi J-S, Selberherr A, Kaider A, Blineder M, Starlinger V, et al. Envelope versus fine structure speech coding strategy: a crossover study. Otol Neurotol. 2011;32:1094\u2013101.","journal-title":"Otol Neurotol"},{"key":"4469_CR22","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1097\/01.aud.0000240811.67906.55","volume":"27","author":"C Willeboer","year":"2006","unstructured":"Willeboer C, Smoorenburg GF. Comparing cochlear implant users\u2019 speech performance with processor fittings based on conventionally determined T and C levels or on compound action potential thresholds and live-voice speech in a prospective balanced crossover study. Ear Hear. 2006;27:789\u201398.","journal-title":"Ear Hear"},{"key":"4469_CR23","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1177\/000331979004100901","volume":"41","author":"TJM Cleophas","year":"1990","unstructured":"Cleophas TJM. Underestimation of treatment effect in crossover trials. Angiology. 1990;41:673\u201380.","journal-title":"Angiology"},{"key":"4469_CR24","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.conb.2005.06.004","volume":"15","author":"JC Middlebrooks","year":"2005","unstructured":"Middlebrooks JC, Bierer JA, Snyder RL. Cochlear implants: the view from the brain. Curr Opin Neurobiol. 2005;15:488\u201393.","journal-title":"Curr Opin Neurobiol"},{"key":"4469_CR25","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1152\/physrev.00002.2002","volume":"82","author":"J Syka","year":"2002","unstructured":"Syka J. Plastic changes in the central auditory system after hearing loss, restoration of function, and during learning. Physiol Rev. 2002;82:601\u201336.","journal-title":"Physiol Rev"},{"key":"4469_CR26","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.heares.2014.10.001","volume":"322","author":"K Strelnikov","year":"2015","unstructured":"Strelnikov K, Marx M, Lagleyre S, Fraysse B, Deguine O, Barone P. PET-imaging of brain plasticity after cochlear implantation. Hear Res. 2015;322:180\u20137.","journal-title":"Hear Res"},{"key":"4469_CR27","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.heares.2007.08.004","volume":"238","author":"JB Fallon","year":"2008","unstructured":"Fallon JB, Irvine DRF, Shepherd RK. Cochlear implants and brain plasticity. Hear Res. 2008;238:110\u20137.","journal-title":"Hear Res"},{"key":"4469_CR28","doi-asserted-by":"crossref","unstructured":"Kral A, Tillein J. Brain plasticity under cochlear implant stimulation. Cochlear Brainstem Implant. 2006;64:89\u2013108.","DOI":"10.1159\/000094647"},{"key":"4469_CR29","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.neuroimage.2014.02.031","volume":"94","author":"D Bottari","year":"2014","unstructured":"Bottari D, Heimler B, Caclin A, Dalmolin A, Giard M-H, Pavani F. Visual change detection recruits auditory cortices in early deafness. Neuroimage. 2014;94:172\u201384.","journal-title":"Neuroimage"},{"key":"4469_CR30","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1038\/nn763","volume":"4","author":"EM Finney","year":"2001","unstructured":"Finney EM, Fine I, Dobkins KR. Visual stimuli activate auditory cortex in the deaf. Nat Neurosci. 2001;4:1171.","journal-title":"Nat Neurosci"},{"key":"4469_CR31","volume":"36","author":"DM Landsberger","year":"2015","unstructured":"Landsberger DM, Svrakic Svrakic J, Svirsky M. The relationship between insertion angles, default frequency allocations, and spiral ganglion place pitch in cochlear implants. Ear Hear. 2015;36:e207.","journal-title":"Ear Hear"},{"key":"4469_CR32","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/00003446-200206000-00003","volume":"23","author":"JHM Frijns","year":"2002","unstructured":"Frijns JHM, Briaire JJ, de Laat JAPM, Grote JJ. Initial evaluation of the Clarion CII cochlear implant: speech perception and neural response imaging. Ear Hear. 2002;23:184\u201397.","journal-title":"Ear Hear"},{"key":"4469_CR33","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1121\/1.419724","volume":"102","author":"RS Tyler","year":"1997","unstructured":"Tyler RS, Parkinson AJ, Woodworth GG, Lowder MW, Gantz BJ. Performance over time of adult patients using the Ineraid or Nucleus cochlear implant. J Acoust Soc Am. 1997;102:508\u201322.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR34","doi-asserted-by":"crossref","first-page":"51S","DOI":"10.1097\/00003446-199617031-00006","volume":"17","author":"K Robinson","year":"1996","unstructured":"Robinson K, Summerfield AQ. Adult auditory learning and training. Ear Hear. 1996;17:51S\u201365S.","journal-title":"Ear Hear"},{"key":"4469_CR35","doi-asserted-by":"crossref","first-page":"38S","DOI":"10.1097\/00003446-199617031-00005","volume":"17","author":"RS Tyler","year":"1996","unstructured":"Tyler RS, Summerfield AQ. Cochlear implantation: relationships with research on auditory deprivation and acclimatization. Ear Hear. 1996;17:38S\u201350S.","journal-title":"Ear Hear"},{"key":"4469_CR36","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin J-C, Pujol S, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012;30:1323\u201341.","journal-title":"Magn Reson Imaging"},{"key":"4469_CR37","first-page":"1","volume":"57","author":"H Johnson","year":"2007","unstructured":"Johnson H, Harris G, Williams K. BRAINSFit: mutual information rigid registrations of whole-brain 3D images, using the insight toolkit. Insight J. 2007;57:1\u201310.","journal-title":"Insight J"},{"key":"4469_CR38","doi-asserted-by":"crossref","first-page":"e231","DOI":"10.1097\/MAO.0000000000001726","volume":"39","author":"G Dees","year":"2018","unstructured":"Dees G, Smits JJ, Janssen AML, Hof JR, Gazibegovic D, van Hoof M, et al. A mid-scala cochlear implant electrode design achieves a stable post-surgical position in the cochlea of patients over time\u2014a prospective observational study. Otol Neurotol. 2018;39:e231\u20139.","journal-title":"Otol Neurotol"},{"key":"4469_CR39","doi-asserted-by":"crossref","first-page":"2","DOI":"10.3389\/fsurg.2016.00002","volume":"3","author":"G Dees","year":"2016","unstructured":"Dees G, van Hoof M, Stokroos R. A proposed method for accurate 3D analysis of cochlear implant migration using fusion of cone beam CT. Front Surg. 2016;3:2.","journal-title":"Front Surg"},{"key":"4469_CR40","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.1121\/1.399052","volume":"87","author":"DD Greenwood","year":"1990","unstructured":"Greenwood DD. A cochlear frequency-position function for several species\u201429 years later. J Acoust Soc Am. 1990;87:2592\u2013605.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR41","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s10162-010-0248-x","volume":"12","author":"O Macherey","year":"2011","unstructured":"Macherey O, Deeks JM, Carlyon RP. Extending the limits of place and temporal pitch perception in cochlear implant users. J Assoc Res Otolaryngol. 2011;12:233\u201351.","journal-title":"J Assoc Res Otolaryngol"},{"key":"4469_CR42","volume":"10","author":"W Nogueira","year":"2015","unstructured":"Nogueira W, Litvak LM, Saoji AA, B\u00fcchner A. Design and evaluation of a cochlear implant strategy based on a \u201cphantom\u201d channel. PLoS One. 2015;10:e0120148.","journal-title":"PLoS One"},{"key":"4469_CR43","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/AUD.0b013e3181e1d15e","volume":"31","author":"AA Saoji","year":"2010","unstructured":"Saoji AA, Litvak LM. Use of \u201cphantom electrode\u201d technique to extend the range of pitches available through a cochlear implant. Ear Hear. 2010;31:693\u2013701.","journal-title":"Ear Hear"},{"key":"4469_CR44","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1121\/1.1381538","volume":"110","author":"LM Friesen","year":"2001","unstructured":"Friesen LM, Shannon RV, Baskent D, Wang X. Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am. 2001;110:1150\u201363.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR45","doi-asserted-by":"crossref","unstructured":"Byrne D, Dillon H, Ching T, Katsch R, Keidser G. NAL-NL1 procedure for fitting nonlinear hearing aids: characteristics and comparisons with other procedures. J Am Acad Audiol. 2001;12:37\u201351.","DOI":"10.1055\/s-0041-1741117"},{"key":"4469_CR46","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1177\/108471380500900403","volume":"9","author":"S Scollie","year":"2005","unstructured":"Scollie S, Seewald R, Cornelisse L, Moodie S, Bagatto M, Laurnagaray D, et al. The desired sensation level multistage input\/output algorithm. Trends Amplif. 2005;9:159\u201397.","journal-title":"Trends Amplif"},{"key":"4469_CR47","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1159\/000439344","volume":"20","author":"EMJ Devocht","year":"2015","unstructured":"Devocht EMJ, George ELJ, Janssen AML, Stokroos RJ. Bimodal hearing aid retention after unilateral cochlear implantation. Audiol Neurotol. 2015;20:383\u201393.","journal-title":"Audiol Neurotol"},{"key":"4469_CR48","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1121\/1.1502902","volume":"112","author":"T Brand","year":"2002","unstructured":"Brand T, Hohmann V. An adaptive procedure for categorical loudness scaling. J Acoust Soc Am. 2002;112:1597\u2013604.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR49","doi-asserted-by":"crossref","first-page":"260","DOI":"10.3109\/00206099509071918","volume":"34","author":"AJ Bosman","year":"1995","unstructured":"Bosman AJ, Smoorenburg GF. Intelligibility of Dutch CVC syllables and sentences for listeners with normal hearing and with three types of hearing impairment. Audiology. 1995;34:260\u201384.","journal-title":"Audiology"},{"key":"4469_CR50","doi-asserted-by":"crossref","first-page":"233121651558313","DOI":"10.1177\/2331216515583138","volume":"19","author":"R Houben","year":"2015","unstructured":"Houben R, Dreschler WA. Optimization of the Dutch matrix test by random selection of sentences from a preselected subset. Trends Hear. 2015;19:2331216515583138.","journal-title":"Trends Hear"},{"key":"4469_CR51","doi-asserted-by":"crossref","first-page":"817","DOI":"10.3109\/14992027.2014.922223","volume":"53","author":"FL Theelen-van den Hoek","year":"2014","unstructured":"Theelen-van den Hoek FL, Houben R, Dreschler WA. Investigation into the applicability and optimization of the Dutch matrix sentence test for use with cochlear implant users. Int J Audiol. 2014;53:817\u201328.","journal-title":"Int J Audiol"},{"key":"4469_CR52","doi-asserted-by":"crossref","first-page":"2801","DOI":"10.1121\/1.1479152","volume":"111","author":"T Brand","year":"2002","unstructured":"Brand T, Kollmeier B. Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests. J Acoust Soc Am. 2002;111:2801\u201310.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR53","doi-asserted-by":"crossref","first-page":"48","DOI":"10.3109\/14992027.2014.945623","volume":"54","author":"MW Kaandorp","year":"2015","unstructured":"Kaandorp MW, Smits C, Merkus P, Goverts ST, Festen JM. Assessing speech recognition abilities with digits in noise in cochlear implant and hearing aid users. Int J Audiol. 2015;54:48\u201357.","journal-title":"Int J Audiol"},{"key":"4469_CR54","doi-asserted-by":"crossref","first-page":"233121651772790","DOI":"10.1177\/2331216517727900","volume":"21","author":"EMJ Devocht","year":"2017","unstructured":"Devocht EMJ, Janssen AML, Chalupper J, Stokroos RJ, George ELJ. The benefits of bimodal aiding on extended dimensions of speech perception: Intelligibility, listening effort, and sound quality. Trends Hear. 2017;21:2331216517727900.","journal-title":"Trends Hear"},{"key":"4469_CR55","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1121\/1.3589255","volume":"130","author":"ES Anderson","year":"2011","unstructured":"Anderson ES, Nelson DA, Kreft H, Nelson PB, Oxenham AJ. Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users. J Acoust Soc Am. 2011;130:364\u201375.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR56","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/AUD.0b013e31826709af","volume":"34","author":"T Zhang","year":"2013","unstructured":"Zhang T, Spahr AJ, Dorman MF, Saoji A. The relationship between auditory function of non-implanted ears and bimodal benefit. Ear Hear. 2013;34:133.","journal-title":"Ear Hear"},{"key":"4469_CR57","doi-asserted-by":"crossref","first-page":"EL217","DOI":"10.1121\/1.4813802","volume":"134","author":"JM Aronoff","year":"2013","unstructured":"Aronoff JM, Landsberger DM. The development of a modified spectral ripple test. J Acoust Soc Am. 2013;134:EL217\u201322.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR58","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/14992020400050014","volume":"43","author":"S Gatehouse","year":"2004","unstructured":"Gatehouse S, Noble W. The speech, spatial and qualities of hearing scale (SSQ). Int J Audiol. 2004;43:85\u201399.","journal-title":"Int J Audiol"},{"key":"4469_CR59","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3109\/14992027.2013.781278","volume":"52","author":"W Noble","year":"2013","unstructured":"Noble W, Jensen NS, Naylor G, Bhullar N, Akeroyd MA. A short form of the Speech, Spatial and Qualities of Hearing scale suitable for clinical use: The SSQ12. Int J Audiol. 2013;52:409\u201312.","journal-title":"Int J Audiol"},{"key":"4469_CR60","doi-asserted-by":"crossref","first-page":"375","DOI":"10.3109\/07853890109002092","volume":"33","author":"WJ Furlong","year":"2001","unstructured":"Furlong WJ, Feeny DH, Torrance GW, Barr RD. The Health Utilities Index (HUI\u00ae) system for assessing health-related quality of life in clinical studies. Ann Med. 2001;33:375\u201384.","journal-title":"Ann Med"},{"key":"4469_CR61","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1007\/s12508-016-0109-z","volume":"94","author":"M van Hoof","year":"2016","unstructured":"van Hoof M, Jeuring SFG, Jonkers DMAE, Masclee AAM, Pierik MJ, Stokroos RJ, et al. De Nederlandse vertaling en indruksvalidatie van de ICECAP-A: meten van kwaliteit van leven volgens de capability-benadering. Tijdschr voor gezondheidswetenschappen. 2016;94:313\u201320.","journal-title":"Tijdschr voor gezondheidswetenschappen"},{"key":"4469_CR62","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s11136-011-9927-2","volume":"21","author":"H Al-Janabi","year":"2012","unstructured":"Al-Janabi H, Flynn TN, Coast J. Development of a self-report measure of capability wellbeing for adults: the ICECAP-A. Qual Life Res. 2012;21:167\u201376.","journal-title":"Qual Life Res"},{"key":"4469_CR63","first-page":"3","volume":"25","author":"M Boretzki","year":"1999","unstructured":"Boretzki M. Quantification of significant sound quality attributes in the context of hearing instrument fine tuning. Phonak Hear Syst Focus. 1999;25:3\u201311.","journal-title":"Phonak Hear Syst Focus"},{"key":"4469_CR64","first-page":"1155","volume":"112","author":"J Cohen","year":"1992","unstructured":"Cohen J. Quantitative methods in psychology: a power primer. Psychol Bull. 1992;112:1155\u20139.","journal-title":"Psychol Bull"},{"key":"4469_CR65","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1007\/BF03011261","volume":"43","author":"J Lerman","year":"1996","unstructured":"Lerman J. Study design in clinical research: sample size estimation and power analysis. Can J Anaesth. 1996;43:184\u201391.","journal-title":"Can J Anaesth"},{"key":"4469_CR66","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.heares.2016.07.005","volume":"343","author":"M Stropahl","year":"2017","unstructured":"Stropahl M, Chen L-C, Debener S. Cortical reorganization in postlingually deaf cochlear implant users: intra-modal and cross-modal considerations. Hear Res. 2017;343:128\u201337.","journal-title":"Hear Res"},{"key":"4469_CR67","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1159\/000448581","volume":"21","author":"MA van der Jagt","year":"2016","unstructured":"van der Jagt MA, Briaire JJ, Verbist BM, Frijns JHM. Comparison of the HiFocus Mid-Scala and HiFocus 1J electrode array: angular insertion depths and speech perception outcomes. Audiol Neurotol. 2016;21:316\u201325.","journal-title":"Audiol Neurotol"},{"key":"4469_CR68","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/AUD.0b013e3180312669","volume":"28","author":"G Nogaki","year":"2007","unstructured":"Nogaki G, Fu Q-J, Galvin JJ III. The effect of training rate on recognition of spectrally shifted speech. Ear Hear. 2007;28:132.","journal-title":"Ear Hear"},{"key":"4469_CR69","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/AUD.0b013e31819769ac","volume":"30","author":"T Li","year":"2009","unstructured":"Li T, Galvin JJ III, Fu Q-J. Interactions between unsupervised learning and the degree of spectral mismatch on short-term perceptual adaptation to spectrally-shifted speech. Ear Hear. 2009;30:238.","journal-title":"Ear Hear"},{"key":"4469_CR70","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1038\/1633","volume":"1","author":"PM Hofman","year":"1998","unstructured":"Hofman PM, Van Riswick JGA, Van Opstal AJ. Relearning sound localization with new ears. Nat Neurosci. 1998;1:417.","journal-title":"Nat Neurosci"},{"key":"4469_CR71","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1038\/nn1141","volume":"6","author":"J Fritz","year":"2003","unstructured":"Fritz J, Shamma S, Elhilali M, Klein D. Rapid task-related plasticity of spectrotemporal receptive fields in primary auditory cortex. Nat Neurosci. 2003;6:1216.","journal-title":"Nat Neurosci"},{"key":"4469_CR72","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1038\/nn.2713","volume":"14","author":"C-C Lee","year":"2011","unstructured":"Lee C-C, Middlebrooks JC. Auditory cortex spatial sensitivity sharpens during task performance. Nat Neurosci. 2011;14:108.","journal-title":"Nat Neurosci"},{"key":"4469_CR73","doi-asserted-by":"crossref","first-page":"8574","DOI":"10.1523\/JNEUROSCI.0587-18.2018","volume":"38","author":"K van der Heijden","year":"2018","unstructured":"van der Heijden K, Rauschecker JP, Formisano E, Valente G, de Gelder B. Active sound localization sharpens spatial tuning in human primary auditory cortex. J Neurosci. 2018;38:8574\u201387.","journal-title":"J Neurosci"},{"key":"4469_CR74","doi-asserted-by":"crossref","unstructured":"Ali H, Noble JH, Gifford RH, Labadie RF, Dawant BM, Hansen JHL, et al. Image-guided customization of frequency-place mapping in cochlear implants. In: IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP); 2015 Apr 19-24; Brisbane (QLD). Piscataway (NY): IEEE; 2015. p. 5843\u20137.","DOI":"10.1109\/ICASSP.2015.7179092"},{"key":"4469_CR75","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1121\/1.1856273","volume":"117","author":"D Ba\u015fkent","year":"2005","unstructured":"Ba\u015fkent D, Shannon RV. Interactions between cochlear implant electrode insertion depth and frequency-place mapping. J Acoust Soc Am. 2005;117:1405\u201316.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR76","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1121\/1.1502901","volume":"112","author":"Q-J Fu","year":"2002","unstructured":"Fu Q-J, Shannon RV, Galvin JJ III. Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implant. J Acoust Soc Am. 2002;112:1664\u201374.","journal-title":"J Acoust Soc Am"},{"key":"4469_CR77","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1177\/0003489415616130","volume":"125","author":"EMJ Devocht","year":"2016","unstructured":"Devocht EMJ, Dees G, Arts RAGJ, Smits JJ, George ELJ, van Hoof M, et al. Revisiting place-pitch match in CI recipients using 3D imaging analysis. Ann Otol Rhinol Laryngol. 2016;125:378\u201384.","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"4469_CR78","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/01.aud.0000202357.40662.85","volume":"27","author":"A Faulkner","year":"2006","unstructured":"Faulkner A, Rosen S, Norman C. The right information may matter more than frequency-place alignment: simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion. Ear Hear. 2006;27:139\u201352.","journal-title":"Ear Hear"},{"key":"4469_CR79","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1097\/00003446-199908000-00006","volume":"20","author":"Q-J Fu","year":"1999","unstructured":"Fu Q-J, Shannon RV. Effects of electrode configuration and frequency allocation on vowel recognition with the Nucleus-22 cochlear implant. Ear Hear. 1999;20:332\u201344.","journal-title":"Ear Hear"},{"key":"4469_CR80","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1044\/jshr.3402.427","volume":"34","author":"GA Studebaker","year":"1991","unstructured":"Studebaker GA, Sherbecoe RL. Frequency-importance and transfer functions for recorded CID W-22 word lists. J Speech, Lang Hear Res. 1991;34:427\u201338.","journal-title":"J Speech, Lang Hear Res"},{"key":"4469_CR81","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1177\/108471389600100402","volume":"1","author":"LE Humes","year":"1996","unstructured":"Humes LE, Pavlovic C, Bray V, Barr M. Real-ear measurement of hearing threshold and loudness. Trends Amplif. 1996;1:121\u201335.","journal-title":"Trends Amplif"},{"key":"4469_CR82","doi-asserted-by":"crossref","first-page":"153","DOI":"10.3109\/01050399609047998","volume":"25","author":"J Kiessling","year":"1996","unstructured":"Kiessling J, Schubert M, Archut A. Adaptive fitting of hearing instruments by category loudness scaling (ScalAdapt). Scand Audiol. 1996;25:153\u201360.","journal-title":"Scand Audiol"},{"key":"4469_CR83","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1080\/010503901300007083","volume":"30","author":"AD Pastoors","year":"2001","unstructured":"Pastoors AD, Gebhart TM, Kiessling J. A fitting strategy for digital hearing aids based on loudness and sound quality. Scand Audiol. 2001;30:60\u20134.","journal-title":"Scand Audiol"}],"container-title":["Trials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13063-020-04469-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13063-020-04469-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13063-020-04469-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T21:38:56Z","timestamp":1667079536000},"score":1,"resource":{"primary":{"URL":"https:\/\/trialsjournal.biomedcentral.com\/articles\/10.1186\/s13063-020-04469-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,23]]},"references-count":83,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["4469"],"URL":"https:\/\/doi.org\/10.1186\/s13063-020-04469-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.23377\/v1","asserted-by":"object"}]},"ISSN":["1745-6215"],"issn-type":[{"value":"1745-6215","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,23]]},"assertion":[{"value":"20 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study has been approved by the ethics committee of the Maastricht University Medical Center (MUMC+)(NL64874.068.18 \/ METC 18\u2013028) and has been registered at clinicaltrials.gov (NCT03892941). All subjects included in this study have signed an informed consent form before participation.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"JC is employed at Advanced Bionics. All remaining authors declare they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"564"}}