{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T03:07:12Z","timestamp":1768446432694,"version":"3.49.0"},"reference-count":15,"publisher":"Mattioli1885","issue":"1","license":[{"start":{"date-parts":[[2020,4,21]],"date-time":"2020-04-21T00:00:00Z","timestamp":1587427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,4,21]],"date-time":"2020-04-21T00:00:00Z","timestamp":1587427200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ultrasound J"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Intra-aortic balloon counterpulsation (IAoBC) is a mechanical circulatory support device that has been used for more than 50\u00a0years, mainly for cardiogenic shock. Although its effect on mortality is controversial, IAoBC is still used in a wide variety of pre- and postoperative clinical settings in cardiac surgery centers. IAoBC has a complication rate of approximately 30%, mostly associated with problems during insertion and malpositioning. Thus, an insertion technique based on the use of ultrasound at the patient\u2019s bedside in the intensive care unit (ICU) is proposed.<\/jats:p>","DOI":"10.1186\/s13089-020-00166-7","type":"journal-article","created":{"date-parts":[[2020,4,21]],"date-time":"2020-04-21T14:02:37Z","timestamp":1587477757000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Ultrasound-guided insertion of intra-aortic balloon counterpulsation in intensive care: description of the technique"],"prefix":"10.5826","volume":"12","author":[{"given":"David Rene","family":"Rodriguez Lima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ever Juli\u00e1n","family":"Duran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ever Leonardo","family":"Rojas D\u00edaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dar\u00edo Isa\u00edas","family":"Pinilla Rojas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario Andr\u00e9s","family":"Mercado D\u00edaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yury Forl\u00e1n","family":"Bustos Mart\u00ednez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27750","published-online":{"date-parts":[[2020,4,21]]},"reference":[{"issue":"1","key":"166_CR1","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1186\/s13019-016-0513-0","volume":"11","author":"H Parissis","year":"2016","unstructured":"Parissis H, Graham V, Lampridis S, Lau M, Hooks G, Mhandu PC (2016) IABP: history-evolution-pathophysiology-indications: what we need to know. J Cardiothorac Surg 11(1):122","journal-title":"J Cardiothorac Surg"},{"issue":"5","key":"166_CR2","first-page":"313","volume":"6","author":"RJ Freedman","year":"1991","unstructured":"Freedman RJ (1991) The intra-aortic balloon pump system: current roles and future directions. J Appl Cardiol 6(5):313\u2013318","journal-title":"J Appl Cardiol"},{"issue":"4","key":"166_CR3","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1016\/0003-4975(90)90220-Z","volume":"50","author":"A Kantrowitz","year":"1990","unstructured":"Kantrowitz A (1990) Origins of intraaortic balloon pumping. Ann Thoracic Surg 50(4):672\u2013674","journal-title":"Ann Thoracic Surg"},{"issue":"5","key":"166_CR4","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/0002-8703(62)90012-1","volume":"63","author":"SD Moulopoulos","year":"1962","unstructured":"Moulopoulos SD, Topaz S, Kolff WJ (1962) Diastolic balloon pumping (with carbon dioxide) in the aorta\u2014a mechanical assistance to the failing circulation. Am Heart J 63(5):669\u2013675","journal-title":"Am Heart J"},{"issue":"1","key":"166_CR5","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1161\/CIRCULATIONAHA.109.929810","volume":"122","author":"AJ Rastan","year":"2010","unstructured":"Rastan AJ, Tillmann E, Subramanian S, Lehmkuhl L, Funkat AK, Leontyev S, Doenst T, Walther T, Gutberlet M, Mohr FW (2010) Visceral arterial compromise during intra-aortic balloon counterpulsation therapy. Circulation. 122(1):92\u201399","journal-title":"Circulation."},{"issue":"2","key":"166_CR6","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/0002-9149(80)90644-X","volume":"45","author":"JM Isner","year":"1980","unstructured":"Isner JM, Cohen SR, Virmani R, Lawrinson W, Roberts WC (1980) Complications of the intraaortic balloon counterpulsation device: clinical and morphologic observations in 45 necropsy patients. Am J Cardiol 45(2):260\u2013268","journal-title":"Am J Cardiol"},{"issue":"4","key":"166_CR7","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1111\/j.1540-8191.2006.00268.x","volume":"21","author":"HB Erdogan","year":"2006","unstructured":"Erdogan HB, Goksedef D, Erentug V, Polat A, Bozbuga N, Mansuroglu D, Guler M, Akinci E, Yakut C (2006) In which patients should sheathless IABP be used? An analysis of vascular complications in 1211 cases. J Card Surg 21(4):342\u2013346","journal-title":"J Card Surg"},{"key":"166_CR8","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.ijcard.2016.01.045","volume":"207","author":"Y Poirier","year":"2016","unstructured":"Poirier Y, Voisine P, Plourde G, Rimac G, Perez AB, Costerousse O, Bertrand OF (2016) Efficacy and safety of preoperative intra-aortic balloon pump use in patients undergoing cardiac surgery: a systematic review and meta-analysis. Int J Cardiol 207:67\u201379","journal-title":"Int J Cardiol"},{"issue":"1","key":"166_CR9","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/1749-8090-5-20","volume":"5","author":"H Parissis","year":"2010","unstructured":"Parissis H, Leotsinidis M, Akbar MT, Apostolakis E, Dougenis D (2010) The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome. J Cardiothorac Surg 5(1):20","journal-title":"J Cardiothorac Surg"},{"issue":"2","key":"166_CR10","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1177\/0267659117727825","volume":"33","author":"MM de Jong","year":"2018","unstructured":"de Jong MM, Lorusso R, Al Awami F, Matteuci F, Parise O, Lozekoot P, Bonacchi M, Maessen JG, Johnson DM, Gelsomino S (2018) Vascular complications following intra-aortic balloon pump implantation: an updated review. Perfusion. 33(2):96\u2013104","journal-title":"Perfusion."},{"issue":"2","key":"166_CR11","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/S0022-5223(19)37989-9","volume":"79","author":"R Rajani","year":"1980","unstructured":"Rajani R, Keon WJ, Bedard P (1980) Rupture of an intra-aortic balloon. A case report. J Thoracic Cardiovasc Surg 79(2):301\u2013302","journal-title":"J Thoracic Cardiovasc Surg"},{"issue":"2","key":"166_CR12","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1097\/00003643-200202000-00015","volume":"19","author":"I Medved","year":"2002","unstructured":"Medved I (2002) Ultrasound-guided placement of intra-aortic balloon pump. Eur J Anaesthesiol 19(2):149\u2013150","journal-title":"Eur J Anaesthesiol"},{"issue":"1","key":"166_CR13","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/S0002-9149(97)89148-5","volume":"77","author":"T Nishioka","year":"1996","unstructured":"Nishioka T, Friedman A, Cercek B, Chaux A, Luo H, Berglund H, Kim CJ, Blanche C, Siegel RJ (1996) Usefulness of transesophageal echocardiography for positioning the intraaortic balloon pump in the operating room. Am J Cardiol 77(1):105\u2013106","journal-title":"Am J Cardiol"},{"issue":"1","key":"166_CR14","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1213\/ANE.0b013e3182140b9a","volume":"113","author":"MA Klopman","year":"2011","unstructured":"Klopman MA, Chen EP, Sniecinski RM (2011) Positioning an intraaortic balloon pump using intraoperative transesophageal echocardiogram guidance. Anesth Analg 113(1):40\u201343","journal-title":"Anesth Analg"},{"issue":"9","key":"166_CR15","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.echo.2013.07.009","volume":"26","author":"RT Hahn","year":"2013","unstructured":"Hahn RT, Abraham T, Adams MS, Bruce CJ, Glas KE, Lang RM, Reeves ST, Shanewise JS, Siu SC, Stewart W, Picard MH (2013) Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American society of echocardiography and the society of cardiovascular anesthesiologists. J Am Soc Echocardiogr 26(9):921\u2013964","journal-title":"J Am Soc Echocardiogr"}],"container-title":["The Ultrasound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-020-00166-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13089-020-00166-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-020-00166-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:34:15Z","timestamp":1768408455000},"score":1,"resource":{"primary":{"URL":"https:\/\/theultrasoundjournal.springeropen.com\/articles\/10.1186\/s13089-020-00166-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,21]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["166"],"URL":"https:\/\/doi.org\/10.1186\/s13089-020-00166-7","relation":{},"ISSN":["2524-8987"],"issn-type":[{"value":"2524-8987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,21]]},"assertion":[{"value":"22 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The present study is in line with the recommendations for biomedical research of the Helsinki Declaration of the World Medical Association and is in accordance with the regulations set forth in Resolution No. 008430 of 1993 (October 4, 1993) of the Ministry of Health of Colombia, which establishes the academic, technical and administrative standards for health research. The images used in the present study were acquired from a single patient who signed an informed consent form for their use. The use of this information was approved and evaluated by the Research Technician of Mayor M\u00e9deri University Hospital and of the Ethics Committee of Del Rosario University (Universidad del Rosario\u2013UR) (DVO005 1052-CV1206).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The patients signed an informed consent form for the publication of the images used in the present study, specifically the institutional form of Mayor M\u00e9deri University Hospital. Based on this consent, all the information that can identify or be associated with the person is anonymized to guarantee the confidentiality of the patient.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"23"}}