{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T23:30:24Z","timestamp":1794958224309,"version":"4.9.1"},"reference-count":18,"publisher":"Mattioli1885","issue":"1","license":[{"start":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T00:00:00Z","timestamp":1673481600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T00:00:00Z","timestamp":1673481600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100008793","name":"Universidad del Rosario","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008793","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ultrasound J"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Spontaneous and traumatic pneumothorax are most often treated with chest tube (CT) thoracostomy. However, it appears that small-bore drainage systems have similar success rates with lower complications, pain, and discomfort for the patient. We present the description of the ultrasound-guided technique for pneumothorax drainage with an 8.3-French pigtail catheter (PC) in a case series of 10 patients.<\/jats:p>","DOI":"10.1186\/s13089-022-00303-4","type":"journal-article","created":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T06:12:25Z","timestamp":1673503945000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Management of pneumothorax with 8.3-French Pigtail Catheter: description of the ultrasound-guided technique and case series"],"prefix":"10.5826","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1929-2299","authenticated-orcid":false,"given":"Camilo","family":"Ram\u00edrez-Giraldo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6888-5595","authenticated-orcid":false,"given":"Carlos Eduardo","family":"Rey-Chaves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7089-018X","authenticated-orcid":false,"given":"David Rene","family":"Rodriguez Lima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27750","published-online":{"date-parts":[[2023,1,12]]},"reference":[{"issue":"5","key":"303_CR1","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1016\/j.jemermed.2021.07.006","volume":"61","author":"J Tran","year":"2021","unstructured":"Tran J, Haussner W, Shah K (2021) Traumatic pneumothorax: a review of current diagnostic practices and evolving management. J Emerg Med 61(5):517\u2013528. https:\/\/doi.org\/10.1016\/j.jemermed.2021.07.006","journal-title":"J Emerg Med"},{"issue":"1","key":"303_CR2","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.anclin.2018.09.009","volume":"37","author":"SM Galvagno","year":"2019","unstructured":"Galvagno SM, Nahmias JT, Young DA (2019) Advanced trauma life support\u00ae update 2019: management and applications for adults and special populations. Anesthesiol Clin 37(1):13\u201332","journal-title":"Anesthesiol Clin"},{"issue":"5","key":"303_CR3","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1016\/S0003-4975(97)00082-9","volume":"63","author":"ER Munnell","year":"1997","unstructured":"Munnell ER (1997) Thoracic drainage. Ann Thorac Surg 63(5):1497\u20131502","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"303_CR4","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1016\/j.chest.2018.01.048","volume":"153","author":"SH Chang","year":"2018","unstructured":"Chang SH, Kang YN, Chiu HY, Chiu YH (2018) A systematic review and meta-analysis comparing pigtail catheter and chest tube as the initial treatment for pneumothorax. Chest 153(5):1201\u20131212. https:\/\/doi.org\/10.1016\/j.chest.2018.01.048","journal-title":"Chest"},{"issue":"3","key":"303_CR5","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1007\/s00268-020-05852-0","volume":"45","author":"ZM Bauman","year":"2021","unstructured":"Bauman ZM, Kulvatunyou N, Joseph B, Gries L, O\u2019Keeffe T, Tang AL et al (2021) Randomized clinical trial of 14-French (14F) pigtail catheters versus 28\u201332F chest tubes in the management of patients with traumatic hemothorax and hemopneumothorax. World J Surg 45(3):880\u2013886. https:\/\/doi.org\/10.1007\/s00268-020-05852-0","journal-title":"World J Surg"},{"key":"303_CR6","doi-asserted-by":"publisher","unstructured":"Collins CD, Lopez A, Mathie A, Wood V, Jackson JE, Roddie ME. Quantification of pneumothorax size on chest\nradiographs using interpleural distances: regression analysis based on volume measurements from helical CT. AJR\nAm J Roentgenol. 1995 Nov;165(5):1127-30.https:\/\/doi.org\/10.2214\/ajr.165.5.7572489. PMID: 7572489.","DOI":"10.2214\/ajr.165.5.7572489"},{"issue":"12","key":"303_CR7","doi-asserted-by":"publisher","first-page":"2658","DOI":"10.1016\/j.ajem.2020.09.028","volume":"38","author":"T Maezawa","year":"2020","unstructured":"Maezawa T, Yanai M, Huh JY, Ariyoshi K (2020) Effectiveness and safety of small-bore tube thoracostomy (\u2264 20 Fr) for chest trauma patients\u202f: a retrospective observational study. Am J Emerg Med 38(12):2658\u20132660. https:\/\/doi.org\/10.1016\/j.ajem.2020.09.028","journal-title":"Am J Emerg Med"},{"issue":"47","key":"303_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/MD.0000000000013255","volume":"97","author":"M Fang","year":"2018","unstructured":"Fang M, Liu G, Luo G, Wu T (2018) Does pigtail catheters relieve pneumothorax? Medicine (Baltimore) 97(47):1\u20135","journal-title":"Medicine (Baltimore)"},{"issue":"3","key":"303_CR9","first-page":"292","volume":"4","author":"F Aziz","year":"2012","unstructured":"Aziz F, Penupolu S, Flores D (2012) Efficacy of percutaneous pigtail catheters for thoracostomy at bedside. J Thorac Dis 4(3):292\u2013295","journal-title":"J Thorac Dis"},{"issue":"4","key":"303_CR10","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/j.ajem.2009.01.033","volume":"28","author":"Y Lin","year":"2010","unstructured":"Lin Y, Tu C, Liang S, Chen H, Chen W, Hsia T et al (2010) Pigtail catheter for the management of pneumothorax in mechanically ventilated patients. Am J Emerg Med 28(4):466\u2013471. https:\/\/doi.org\/10.1016\/j.ajem.2009.01.033","journal-title":"Am J Emerg Med"},{"issue":"2","key":"303_CR11","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1002\/bjs.9377","volume":"101","author":"N Kulvatunyou","year":"2014","unstructured":"Kulvatunyou N, Erickson L, Vijayasekaran A, Gries L, Joseph B, Friese RF et al (2014) Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax. Br J Surg 101(2):17\u201322","journal-title":"Br J Surg"},{"issue":"2","key":"303_CR12","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1097\/TA.0b013e3182452444","volume":"72","author":"K Inaba","year":"2010","unstructured":"Inaba K, Lustenberger T, Recinos G, Georgiou C, Velmahos GC, Brown C et al (2010) Does size matter? A prospective analysis of 28\u201332 versus 36\u201340 French chest tube size in trauma. J Trauma Acute Care Surg 72(2):422\u2013427","journal-title":"J Trauma Acute Care Surg"},{"key":"303_CR13","doi-asserted-by":"publisher","DOI":"10.1186\/s13089-020-00172-9","author":"DR Rodriguez Lima","year":"2020","unstructured":"Rodriguez Lima DR, Yepes AF, Birchenall Jim\u00e9nez CI, Mercado D\u00edaz MA, Pinilla Rojas DI (2020) Real-time ultrasound-guided thoracentesis in the intensive care unit: prevalence of mechanical complications. Ultrasound J. https:\/\/doi.org\/10.1186\/s13089-020-00172-9","journal-title":"Ultrasound J"},{"key":"303_CR14","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-00284-8","author":"T Tsai","year":"2017","unstructured":"Tsai T, Lin M, Li Y, Chang C, Liao H, Hsu H et al (2017) The size of spontaneous pneumothorax is a predictor of unsuccessful catheter drainage. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-017-00284-8","journal-title":"Sci Rep"},{"issue":"5","key":"303_CR15","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.resinv.2018.06.003","volume":"56","author":"S Takeda","year":"2018","unstructured":"Takeda S, Nagata N, Yoshida Y, Matsumoto T, Aoyama T, Harada T et al (2018) Study of the usefulness of small-bore aspiration catheters (Aspiration Kit\u00ae) for treating pneumothorax. Respir Investig 56(5):405\u2013409. https:\/\/doi.org\/10.1016\/j.resinv.2018.06.003","journal-title":"Respir Investig"},{"issue":"5","key":"303_CR16","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1007\/s00595-013-0759-2","volume":"44","author":"ST Liman","year":"2014","unstructured":"Liman ST, Elicora A, Akgul AG, Topcu S, \u00d6zbay S, Mehmeto\u01e7lu SS et al (2014) Is a small-bore catheter efficient for most pleural pathologies? Surg Today 44(5):834\u2013838","journal-title":"Surg Today"},{"issue":"7","key":"303_CR17","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/j.ajem.2006.04.006","volume":"24","author":"WK Tsai","year":"2006","unstructured":"Tsai WK, Chen W, Chih LJ, Cheng WE, Chen CH, Hsu WH et al (2006) Pigtail catheters vs large-bore chest tubes for management of secondary spontaneous pneumothoraces in adults. Am J Emerg Med 24(7):795\u2013800","journal-title":"Am J Emerg Med"},{"issue":"10","key":"303_CR18","doi-asserted-by":"publisher","first-page":"1436","DOI":"10.1016\/j.rmed.2009.04.022","volume":"103","author":"IJ Benton","year":"2009","unstructured":"Benton IJ, Benfield GFA (2009) Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces. Respir Med 103(10):1436\u20131440. https:\/\/doi.org\/10.1016\/j.rmed.2009.04.022","journal-title":"Respir Med"}],"container-title":["The Ultrasound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-022-00303-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13089-022-00303-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-022-00303-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:34:26Z","timestamp":1768408466000},"score":1,"resource":{"primary":{"URL":"https:\/\/theultrasoundjournal.springeropen.com\/articles\/10.1186\/s13089-022-00303-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,12]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["303"],"URL":"https:\/\/doi.org\/10.1186\/s13089-022-00303-4","relation":{},"ISSN":["2524-8987"],"issn-type":[{"value":"2524-8987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,12]]},"assertion":[{"value":"26 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The present study is in line with the recommendations for biomedical research of the Helsinki Declaration of the World Medical Association and is in accordance with the regulations set forth in Resolution No. 008430 of 1993 (October 4, 1993) of the Ministry of Health of Colombia, which establishes the academic, technical, and administrative standards for health research. The images used in the present study were acquired from a single patient who signed an informed consent form for their use. The use of this information was approved and evaluated by the Research Technician of Mayor M\u00e9deri University Hospital and of the Ethics Committee of Del Rosario University (Universidad del Rosario\u2013UR) (DVO005 2013-CV1585).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The patients signed an informed consent form for the publication of the images used in the present study, specifically the institutional form of Mayor M\u00e9deri University Hospital. Based on this consent, all the information that can identify or be associated with the person is anonymized to guarantee the confidentiality of the patient.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1"}}