{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T21:31:15Z","timestamp":1777757475965,"version":"3.51.4"},"reference-count":25,"publisher":"Mattioli1885","issue":"1","license":[{"start":{"date-parts":[[2023,5,6]],"date-time":"2023-05-06T00:00:00Z","timestamp":1683331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,6]],"date-time":"2023-05-06T00:00:00Z","timestamp":1683331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ultrasound J"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Subglottic secretion had been proven as one of the causes of microaspiration and increased risk of ventilator-associated pneumonia (VAP). The role of ultrasound to detect subglottic secretion has not yet been established.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study is to determine the sensitivity and specificity of upper airway ultrasound (US) in the detection of subglottic secretions as compared to computed tomography (CT) scanning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and methods<\/jats:title>\n                    <jats:p>\n                      A prospective observational study was carried out in adult trauma patients requiring mechanical ventilation and cervical CT scan. All patients had an endotracheal tube cuff-pressure maintained between 20 and 30\u00a0cm H\n                      <jats:sub>2<\/jats:sub>\n                      O. Airway US was performed at the bedside immediately before the patient was transferred to the CT scan suite. The sensitivity, specificity, and positive\/negative predictive values (PPV, NPV) of the upper airway US detection of subglottic secretions were then calculated and compared with CT findings.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Fifty participants were consecutively included. Subglottic secretions were detected in 31 patients using upper airway US. The sensitivity and specificity of upper airway US in detecting subglottic secretion were 96.7% and 90%, respectively (PPV 93.5%, NPV 94.7%). 18 (58%) patients with subglottic secretions developed VAP during their ICU stay (\n                      <jats:italic>p\u2009=\u20090.01<\/jats:italic>\n                      ). The area under the receiver operating curve (AUROC) was 0.977 (95% CI 0.936\u20131.00).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Upper airway US is a useful tool for detecting subglottic secretions with high sensitivity and specificity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical implications<\/jats:title>\n                    <jats:p>\n                      This study shows:\n                      <jats:list list-type=\"order\">\n                        <jats:list-item>\n                          <jats:p>Upper airway US may aid in detecting subglottic secretions, which are linked to VAP.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Detecting subglottic secretions at the bedside aids in determining the best frequency of subglottic aspiration to clean the subglottic trachea.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Upper airway US may also aid in detecting the correct ETT position.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:italic>Trial registration<\/jats:italic>\n                      Clinicaltrials.gov. Clinicaltrials.gov identifier NCT04739878 Date of registration 2nd May 2021 URL of trial registry record\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/ct2\/show\/NCT04739878\">https:\/\/clinicaltrials.gov\/ct2\/show\/NCT04739878<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13089-023-00318-5","type":"journal-article","created":{"date-parts":[[2023,5,6]],"date-time":"2023-05-06T05:02:19Z","timestamp":1683349339000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Airway ultrasound to detect subglottic secretion above endotracheal tube cuff"],"prefix":"10.5826","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4932-8907","authenticated-orcid":false,"given":"Osman","family":"Adi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chan Pei","family":"Fong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roslanuddin Mohd","family":"Sallehuddin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Azma Haryaty","family":"Ahmad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kok Meng","family":"Sum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zulrushdi Md","family":"Yusof","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriele","family":"Via","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guido","family":"Tavazzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27750","published-online":{"date-parts":[[2023,5,6]]},"reference":[{"key":"318_CR1","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s10877-020-00501-2","volume":"35","author":"CM Kumar","year":"2021","unstructured":"Kumar CM, Seet E, Van Zunder TCRV (2021) Measuring endotracheal tube intracuff pressure: no room for complacency. J Clin Monit Comput 35:3\u201310. https:\/\/doi.org\/10.1007\/s10877-020-00501-2","journal-title":"J Clin Monit Comput"},{"key":"318_CR2","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1007\/BF01706421","volume":"18","author":"P Mahul","year":"1992","unstructured":"Mahul P, Auboyer C, Jospe R, Ros A, Guerin C, Khouri Z, Galliez M, Dumont A, Gaudin O (1992) Prevention of nosocomial pneumonia in intubated patients: respective role of mechanical subglottic secretions drainage and stress ulcer prophylaxis. Intensive Care Med 18:20\u201325. https:\/\/doi.org\/10.1007\/BF01706421","journal-title":"Intensive Care Med"},{"issue":"2","key":"318_CR3","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.hrtlng.2011.09.001","volume":"41","author":"VA Hamilton","year":"2012","unstructured":"Hamilton VA, Grap MJ (2012) The role of the endotracheal tube cuff in microaspiration. Heart Lung J Crit Care 41(2):167\u2013172. https:\/\/doi.org\/10.1016\/j.hrtlng.2011.09.001","journal-title":"Heart Lung J Crit Care"},{"issue":"21","key":"318_CR4","doi-asserted-by":"publisher","first-page":"422","DOI":"10.21037\/atm.2018.10.40","volume":"6","author":"JC Lacherade","year":"2018","unstructured":"Lacherade JC, Azais MA, Pouplet C, Colin G (2018) Subglottic secretion drainage for ventilator-associated pneumonia prevention: an underused efficient measure. Ann Transl Med 6(21):422. https:\/\/doi.org\/10.21037\/atm.2018.10.40","journal-title":"Ann Transl Med"},{"issue":"155","key":"318_CR5","doi-asserted-by":"publisher","first-page":"190107","DOI":"10.1183\/16000617.0107-2019","volume":"29","author":"DP Pozuelo-Carrascosa","year":"2020","unstructured":"Pozuelo-Carrascosa DP, Herr\u00e1iz-Adillo \u00c1, Alvarez-Bueno C, A\u00f1\u00f3n JM, Mart\u00ednez-Vizca\u00edno V, Cavero-Redondo I (2020) Subglottic secretion drainage for preventing ventilator-associated pneumonia: an overview of systematic reviews: and an updated meta-analysis. Eur Respir Rev Off J Eur Respir Soc 29(155):190107. https:\/\/doi.org\/10.1183\/16000617.0107-2019","journal-title":"Eur Respir Rev Off J Eur Respir Soc"},{"issue":"suppl 4","key":"318_CR6","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1183\/23120541.RFMVC-2020.27","volume":"6","author":"Y Li","year":"2020","unstructured":"Li Y, Wang Y (2020) The association of subglottic secretion drainage and tracheal mucosa injury. ERJ Open Res 6(suppl 4):27. https:\/\/doi.org\/10.1183\/23120541.RFMVC-2020.27","journal-title":"ERJ Open Res"},{"issue":"6","key":"318_CR7","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.iccn.2013.02.007","volume":"29","author":"E Suys","year":"2013","unstructured":"Suys E, Nieboer K, Stiers W, De Regt J, Huyghens L, Spapen H (2013) Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions. Intensive Crit Care Nurs 29(6):317\u2013320. https:\/\/doi.org\/10.1016\/j.iccn.2013.02.007","journal-title":"Intensive Crit Care Nurs"},{"issue":"6","key":"318_CR8","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.2214\/ajr.163.6.7992723","volume":"163","author":"R Greene","year":"1994","unstructured":"Greene R, Thompson S, Jantsch HS, Teplick R, Cullen DJ, Greene EM, Whitman GJ, Hulka CA, Llewellyn HJ (1994) Detection of pooled secretions above endotracheal-tube cuffs: value of plain radiographs in sheep cadavers and patients. AJR Am J Roentgenol 163(6):1333\u20131337. https:\/\/doi.org\/10.2214\/ajr.163.6.7992723","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"318_CR9","doi-asserted-by":"publisher","first-page":"982","DOI":"10.2214\/AJR.13.11392","volume":"202","author":"SR Hong","year":"2014","unstructured":"Hong SR, Lee YJ, Hong YJ, Hur J, Kim YJ, Choi BW, Lee HJ (2014) Differentiation between mucus secretion and endoluminal tumors in the airway: analysis and comparison of CT findings. AJR Am J Roentgenol 202(5):982\u2013988. https:\/\/doi.org\/10.2214\/AJR.13.11392","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"318_CR10","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1097\/ALN.0000000000003528","volume":"133","author":"KM Tao","year":"2020","unstructured":"Tao KM, Zhu CC, Lu ZJ (2020) Ultrasound-guided visualization of subglottic secretions in intubated patients. Anesthesiology 133(6):1260. https:\/\/doi.org\/10.1097\/ALN.0000000000003528","journal-title":"Anesthesiology"},{"issue":"3","key":"318_CR11","doi-asserted-by":"publisher","first-page":"197","DOI":"10.23736\/S0375-9393.21.16110-3","volume":"88","author":"Y Ji","year":"2022","unstructured":"Ji Y, Gui M, Tao KM (2022) Ultrasound detection of subglottic secretions caused by gastric regurgitation in a patient under general anesthesia. Minerva Anestesiol 88(3):197\u2013198. https:\/\/doi.org\/10.23736\/S0375-9393.21.16110-3","journal-title":"Minerva Anestesiol"},{"key":"318_CR12","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/2032748","author":"F Bulamba","year":"2017","unstructured":"Bulamba F, Kintu A, Ayupo N, Kojjo C, Ssemogerere L, Wabule A, Kwizera A (2017) Achieving the recommended endotracheal tube cuff pressure: a randomized control study comparing loss of resistance syringe to pilot balloon palpation. Anesthesiol Res Pract. https:\/\/doi.org\/10.1155\/2017\/2032748","journal-title":"Anesthesiol Res Pract"},{"key":"318_CR13","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s40560-016-0174-z","volume":"4","author":"A Osman","year":"2016","unstructured":"Osman A, Sum KM (2016) Role of upper airway ultrasound in airway management. J Intensive Care 4:52. https:\/\/doi.org\/10.1186\/s40560-016-0174-z","journal-title":"J Intensive Care"},{"key":"318_CR14","doi-asserted-by":"publisher","first-page":"1824","DOI":"10.1007\/s00134-019-05689-9","volume":"45","author":"A Bianchini","year":"2019","unstructured":"Bianchini A, D\u2019Andrea R, Querci L, Mega C (2019) Echo-guided air-filled endotracheal tube cuff visualization. Intensive Care Med 45:1824\u20131825. https:\/\/doi.org\/10.1007\/s00134-019-05689-9","journal-title":"Intensive Care Med"},{"issue":"3","key":"318_CR15","doi-asserted-by":"publisher","first-page":"837","DOI":"10.2307\/2531595","volume":"44","author":"ER DeLong","year":"1988","unstructured":"DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44(3):837\u2013845","journal-title":"Biometrics"},{"issue":"6","key":"318_CR16","doi-asserted-by":"publisher","first-page":"W320","DOI":"10.2214\/AJR.07.2123","volume":"189","author":"S Strauss","year":"2007","unstructured":"Strauss S, Gavish E, Gottlieb P, Katsnelson L (2007) Interobserver and intraobserver variability in the sonographic assessment of fatty liver. AJR Am J Roentgenol 189(6):W320\u2013W323. https:\/\/doi.org\/10.2214\/AJR.07.2123","journal-title":"AJR Am J Roentgenol"},{"issue":"34","key":"318_CR17","doi-asserted-by":"publisher","first-page":"3730","DOI":"10.14260\/jemds\/2018\/838","volume":"7","author":"G Dhawan","year":"2018","unstructured":"Dhawan G (2018) Subglottic and closed endotracheal suctioning versus open endotracheal suctioning- effect on ventilator-associated pneumonia rates and length of intensive care unit stay. J Evol Med Dent Sci 7(34):3730\u20133733. https:\/\/doi.org\/10.14260\/jemds\/2018\/838","journal-title":"J Evol Med Dent Sci"},{"issue":"2","key":"318_CR18","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1213\/ANE.0b013e3182991d42","volume":"117","author":"M Sirisopana","year":"2013","unstructured":"Sirisopana M, Saint-Martin C, Wang NN, Manoukian J, Nguyen LH, Brown KA (2013) Novel measurements of the length of the subglottic airway in infants and young children. Anesth Analg 117(2):462\u2013470. https:\/\/doi.org\/10.1213\/ANE.0b013e3182991d42","journal-title":"Anesth Analg"},{"issue":"5","key":"318_CR19","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1002\/acr.23332","volume":"70","author":"FO Henes","year":"2018","unstructured":"Henes FO, Laudien M, Linsenhoff L, Bremer JP, Oqueka T, Adam G, Sch\u00f6n G, Bannas P (2018) Accuracy of magnetic resonance imaging for grading of subglottic stenosis in patients with granulomatosis with polyangiitis: correlation with pulmonary function tests and laryngoscopy. Arthritis Care Res 70(5):777\u2013784. https:\/\/doi.org\/10.1002\/acr.23332","journal-title":"Arthritis Care Res"},{"issue":"3","key":"318_CR20","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1148\/rg.2019180076","volume":"39","author":"J Shi","year":"2019","unstructured":"Shi J, Uyeda JW, Duran-Mendicuti A, Potter CA, Nunez DB (2019) Multidetector CT of laryngeal injuries principles of injury recognition. Radiographics 39(3):879\u2013892. https:\/\/doi.org\/10.1148\/rg.2019180076","journal-title":"Radiographics"},{"key":"318_CR21","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s13089-015-0031-7","volume":"7","author":"J Chenkin","year":"2015","unstructured":"Chenkin J, McCartney CJ, Jelic T, Romano M, Heslop C, Bandiera G (2015) Defining the learning curve of point-of-care ultrasound for confirming endotracheal tube placement by emergency physicians. Crit Ultrasound J 7:14. https:\/\/doi.org\/10.1186\/s13089-015-0031-7","journal-title":"Crit Ultrasound J"},{"key":"318_CR22","doi-asserted-by":"publisher","first-page":"31","DOI":"10.21037\/jeccm.2019.06.0","volume":"3","author":"O Adi","year":"2019","unstructured":"Adi O, Kok MS, Abdull Wahab SF (2019) Focused airway ultrasound: an armamentarium in future airway management. J Emerg Crit Care Med 3:31. https:\/\/doi.org\/10.21037\/jeccm.2019.06.0","journal-title":"J Emerg Crit Care Med"},{"issue":"1","key":"318_CR23","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s13089-020-00186-3","volume":"12","author":"O Adi","year":"2020","unstructured":"Adi O, Sum KM, Ahmad AH, Wahab MA, Neri L, Panebianco N (2020) Novel role of focused airway ultrasound in early airway assessment of suspected laryngeal trauma. Ultrasound J 12(1):37. https:\/\/doi.org\/10.1186\/s13089-020-00186-3","journal-title":"Ultrasound J"},{"issue":"1","key":"318_CR24","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/2036-7902-5-7","volume":"5","author":"O Adi","year":"2013","unstructured":"Adi O, Chuan TW, Rishya M (2013) A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation. Crit Ultrasound J 5(1):7. https:\/\/doi.org\/10.1186\/2036-7902-5-7","journal-title":"Crit Ultrasound J"},{"issue":"1","key":"318_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4103\/ijccm.IJCCM_350_17","volume":"22","author":"P Seguin","year":"2018","unstructured":"Seguin P, Perrichet H, Pabic EL, Launey Y, Tiercin M, Corre R, Brinchault G, Laviolle B (2018) Effect of continuous versus intermittent subglottic suctioning on tracheal mucosa by the mallinckrodt TaperGuard EVAC oral tracheal tube in intensive care unit ventilated patients: a prospective randomized study. Indian J Crit Care Med Peer-Rev Off Publ Indian Soc Crit Care Med 22(1):1\u20134. https:\/\/doi.org\/10.4103\/ijccm.IJCCM_350_17","journal-title":"Indian J Crit Care Med Peer-Rev Off Publ Indian Soc Crit Care Med"}],"container-title":["The Ultrasound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-023-00318-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13089-023-00318-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-023-00318-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:34:27Z","timestamp":1768408467000},"score":1,"resource":{"primary":{"URL":"https:\/\/theultrasoundjournal.springeropen.com\/articles\/10.1186\/s13089-023-00318-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,6]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["318"],"URL":"https:\/\/doi.org\/10.1186\/s13089-023-00318-5","relation":{},"ISSN":["2524-8987"],"issn-type":[{"value":"2524-8987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,6]]},"assertion":[{"value":"28 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by Medical Research and Ethics Committee of Malaysia Ministry of Health was granted [NMRR-21-1852-61475 (IIR)]. Informed consent was obtained from the patient's parents before enrolment in the study Ethical approval and consent were taken for this study. I declare that this manuscript depicts the Airway Ultrasound To Detect Subglottic Secretion Above Endotracheal Tube (ETT) Cuff Contributions from respective authors have been explicitly mentioned in the respective segment. This work has not been submitted to any other publication for publishing.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"23"}}