{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:40:48Z","timestamp":1787020848217,"version":"build-2736575974"},"reference-count":21,"publisher":"Mattioli1885","issue":"1","license":[{"start":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T00:00:00Z","timestamp":1684800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T00:00:00Z","timestamp":1684800000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ultrasound J"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Although lung sliding seen by point-of-care ultrasound (POCUS) is known to be affected to varying degrees by different physiologic and pathologic processes, it is typically only reported qualitatively in the critical care setting. Lung sliding amplitude quantitatively expresses the amount of pleural movement seen by POCUS but its determinants in mechanically ventilated patients are largely unknown.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This was a single-center, prospective, observational pilot study examining 40 hemithoraces in 20 adult patients receiving mechanical ventilation. Each subject had lung sliding amplitude measured in both B-mode and by pulsed wave Doppler at their bilateral lung apices and bases. Differences in lung sliding amplitude were correlated with anatomical location (apex vs base) as well as physiologic parameters including positive end expiratory pressure (PEEP), driving pressure, tidal volume and the ratio of arterial partial pressure of oxygen (PaO\n                      <jats:sub>2<\/jats:sub>\n                      ) to fraction of inspired oxygen (FiO\n                      <jats:sub>2<\/jats:sub>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      POCUS lung sliding amplitude was significantly lower at the lung apex compared to the lung base in both B-mode (3.6\u2009\u00b1\u20092.0\u00a0mm vs 8.6\u2009\u00b1\u20094.3\u00a0mm;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) and the pulsed wave Doppler mode (10.3\u2009\u00b1\u20094.6\u00a0cm\/s vs 13.9\u2009\u00b1\u20095.5\u00a0cm\/s;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) corresponding to expected distribution of ventilation to the lung bases. Inter-rater reliability of B-mode measurements was excellent (ICC\u2009=\u20090.91) and distance traversed in B-mode had a significant positive correlation with pleural line velocity (\n                      <jats:italic>r<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.32;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). There was a non-statistically significant trend towards lower lung sliding amplitude for PEEP\u2009\u2265\u200910\u00a0cmH\n                      <jats:sub>2<\/jats:sub>\n                      O, as well as for driving pressure\u2009\u2265\u200915\u00a0cmH\n                      <jats:sub>2<\/jats:sub>\n                      O in both ultrasound modes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      POCUS lung sliding amplitude was significantly lower at the lung apex than the lung base in mechanically ventilated patients. This was true when using both B-mode and pulsed wave Doppler. Lung sliding amplitude did not correlate with PEEP, driving pressure, tidal volume or PaO\n                      <jats:sub>2<\/jats:sub>\n                      :FiO\n                      <jats:sub>2<\/jats:sub>\n                      ratio. Our findings suggest that lung sliding amplitude can be quantified in mechanically ventilated patients in a physiologically predictable way and with high inter-rater reliability. A better understanding of POCUS derived lung sliding amplitude and its determinants may aid in the more accurate diagnosis of lung pathologies, including pneumothorax, and could serve as a means of further reducing radiation exposure and improving outcomes in critically ill patients.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13089-023-00326-5","type":"journal-article","created":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T04:03:19Z","timestamp":1684814599000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Determinants of point-of-care ultrasound lung sliding amplitude in mechanically ventilated patients"],"prefix":"10.5826","volume":"15","author":[{"given":"David N.","family":"Briganti","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine E.","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6748-9010","authenticated-orcid":false,"given":"Charles W.","family":"Lanks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27750","published-online":{"date-parts":[[2023,5,23]]},"reference":[{"issue":"5","key":"326_CR1","doi-asserted-by":"publisher","first-page":"1345","DOI":"10.1378\/chest.108.5.1345","volume":"108","author":"DA Lichtenstein","year":"1995","unstructured":"Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Chest 108(5):1345\u20131348","journal-title":"Chest"},{"issue":"1","key":"326_CR2","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1378\/chest.07-2800","volume":"134","author":"DA Lichtenstein","year":"2008","unstructured":"Lichtenstein DA, Mezi\u00e8re GA (2008) Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest 134(1):117\u2013125","journal-title":"Chest"},{"issue":"10","key":"326_CR3","doi-asserted-by":"publisher","first-page":"1434","DOI":"10.1007\/s001340000627","volume":"26","author":"D Lichtenstein","year":"2000","unstructured":"Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The, \u201clung point\u201d: an ultrasound sign specific to pneumothorax. Intensive Care Med 26(10):1434\u20131440","journal-title":"Intensive Care Med"},{"key":"326_CR4","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1186\/s40560-016-0180-1","volume":"4","author":"F Lee","year":"2016","unstructured":"Lee F (2016) Lung ultrasound\u2014a primary survey of the acutely dyspneic patient. J Intensive Care 4:57","journal-title":"J Intensive Care"},{"key":"326_CR5","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1097\/01.TA.0000133565.88871.E4","volume":"57","author":"K Rowan","year":"2004","unstructured":"Rowan K et al (2004) Hand-held thoracic sonography for detecting post-traumatic pneumothoraces: the extended focused assessment with sonography for trauma (EFAST). J Trauma 57:288\u2013295","journal-title":"J Trauma"},{"issue":"3","key":"326_CR6","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1378\/chest.129.3.545","volume":"129","author":"A Slater","year":"2006","unstructured":"Slater A, Goodwin M, Anderson KE, Gleeson FV (2006) COPD can mimic the appearance of pneumothorax on thoracic ultrasound. Chest 129(3):545\u2013550","journal-title":"Chest"},{"issue":"10","key":"326_CR7","doi-asserted-by":"publisher","first-page":"2034","DOI":"10.1016\/j.ajem.2016.07.032","volume":"34","author":"A Markota","year":"2016","unstructured":"Markota A et al (2016) Absence of lung sliding is not a reliable sign of pneumothorax in patients with high positive end-expiratory pressure. Am J Emerg Med 34(10):2034\u20132036","journal-title":"Am J Emerg Med"},{"issue":"3","key":"326_CR8","doi-asserted-by":"publisher","first-page":"509","DOI":"10.4103\/ejcdt.ejcdt_195_19","volume":"69","author":"MM Khalil","year":"2020","unstructured":"Khalil MM, Salem HM, Habib SM (2020) Validity of pleural sliding sign in patients on controlled mechanical ventilation. Egypt J Chest Dis Tuberc 69(3):509\u2013515","journal-title":"Egypt J Chest Dis Tuberc"},{"issue":"1","key":"326_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4266\/kjccm.2016.00955","volume":"32","author":"DA Lichtenstein","year":"2017","unstructured":"Lichtenstein DA (2017) Lung ultrasound (in the critically ill) superior to CT: the example of lung sliding. Korean J Crit Care Med 32(1):1\u20138","journal-title":"Korean J Crit Care Med"},{"issue":"21","key":"326_CR10","doi-asserted-by":"publisher","first-page":"5889","DOI":"10.12998\/wjcc.v9.i21.5889","volume":"9","author":"R Xiao","year":"2021","unstructured":"Xiao R, Shao Q, Zhao N, Liu F, Qian KJ (2021) Quantification analysis of pleural line movement for the diagnosis of pneumothorax. World J Clin Cases 9(21):5889\u20135899","journal-title":"World J Clin Cases"},{"key":"326_CR11","unstructured":"West JB, Luks AM (2020) Mechanics of breathing. In: West's respiratory physiology: the essentials, 11th edn, Wolters Kluwer, pp 116\u2013150"},{"issue":"3","key":"326_CR12","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1172\/JCI104505","volume":"41","author":"WC Ball","year":"1962","unstructured":"Ball WC, Stewart PB, Newsham LGS, Bates DV (1962) Regional pulmonary function studied with Xenon133. J Clin Invest 41(3):519\u2013531","journal-title":"J Clin Invest"},{"key":"326_CR13","first-page":"133","volume-title":"Physiologic basis of respiratory disease","author":"J Milic-Emili","year":"2005","unstructured":"Milic-Emili J (2005) Ventilation distribution. In: Hamid Q, Shannon J, Martin J (eds) Physiologic basis of respiratory disease, 1st edn. Hamilton, BC Decker, pp 133\u2013141","edition":"1"},{"key":"326_CR14","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1152\/jappl.1966.21.3.749","volume":"21","author":"J Milic-Emili","year":"1966","unstructured":"Milic-Emili J et al (1966) Regional distribution of inspired gas in the lung. J Appl Physiol 21:749\u2013759","journal-title":"J Appl Physiol"},{"issue":"11","key":"326_CR15","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1016\/j.ajem.2017.09.006","volume":"35","author":"G Rose","year":"2017","unstructured":"Rose G et al (2017) A novel method of assessing for lung sliding using doppler imaging. Am J Emerg Med 35(11):1738\u20131742","journal-title":"Am J Emerg Med"},{"issue":"1","key":"326_CR16","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/s13089-020-00184-5","volume":"12","author":"S Martins","year":"2020","unstructured":"Martins S, Nogue R (2020) Vertical displacement of pleura: a new method for bronchospasm evaluation? Ultrasound J 12(1):42","journal-title":"Ultrasound J"},{"issue":"8","key":"326_CR17","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1164\/rccm.200702-193OC","volume":"176","author":"S Grasso","year":"2007","unstructured":"Grasso S et al (2007) ARDSnet ventilatory protocol and alveolar hyperinflation: role of positive end-expiratory pressure. Am J Respir Crit Care Med 176(8):761\u2013767","journal-title":"Am J Respir Crit Care Med"},{"issue":"18","key":"326_CR18","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","volume":"342","author":"Acute Respiratory Distress Syndrome Network","year":"2000","unstructured":"Acute Respiratory Distress Syndrome Network (2000) Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342(18):1301\u20131308","journal-title":"N Engl J Med"},{"issue":"9","key":"326_CR19","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1007\/s00134-019-05710-1","volume":"45","author":"G Duclos","year":"2019","unstructured":"Duclos G et al (2019) Speckle tracking quantification of lung sliding for the diagnosis of pneumothorax: a multicentric observational study. Intensive Care Med 45(9):1212\u20131218","journal-title":"Intensive Care Med"},{"key":"326_CR20","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.ajem.2021.05.022","volume":"49","author":"E Fissore","year":"2021","unstructured":"Fissore E (2021) Pneumothorax diagnosis with lung sliding quantification by speckle tracking: a prospective multicentric observational study. Am J Emerg Med 49:14\u201317","journal-title":"Am J Emerg Med"},{"issue":"1","key":"326_CR21","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/s00134-018-5303-9","volume":"45","author":"G Duclos","year":"2019","unstructured":"Duclos G, Muller L, Leone M, Zieleskiewicz L (2019) A picture\u2019s worth a thousand words: speckle tracking for quantification and assessment of lung sliding. Intensive Care Med 45(1):101\u2013102","journal-title":"Intensive Care Med"}],"container-title":["The Ultrasound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-023-00326-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13089-023-00326-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-023-00326-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:34:27Z","timestamp":1768408467000},"score":1,"resource":{"primary":{"URL":"https:\/\/theultrasoundjournal.springeropen.com\/articles\/10.1186\/s13089-023-00326-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,23]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["326"],"URL":"https:\/\/doi.org\/10.1186\/s13089-023-00326-5","relation":{},"ISSN":["2524-8987"],"issn-type":[{"value":"2524-8987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,23]]},"assertion":[{"value":"9 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was approved by the Lundquist Institute for Biomedical Innovation\u2019s Institutional Review Board and written informed consent was obtained from each subject or their legally authorized representative.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No competing interest to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"25"}}