{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T16:28:56Z","timestamp":1792513736167,"version":"4.5.0"},"reference-count":28,"publisher":"Mattioli1885","issue":"1","license":[{"start":{"date-parts":[[2025,1,13]],"date-time":"2025-01-13T00:00:00Z","timestamp":1736726400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,13]],"date-time":"2025-01-13T00:00:00Z","timestamp":1736726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ultrasound J"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Tele-robotic ultrasound (US) is a novel technique that might help overcome the current shortage of radiologists and poor access to radiologists and\/or sonographers in remote or rural areas. Despite the promising results of this technology in the past two decades, there is still insufficient data about its advantages and limits, as well as the implementation in routine clinical practice and the learning curve for the user. The purpose of this prospective cohort-based study is to evaluate the performance of a 5G-based tele-robotic US system for abdominal and thyroid gland assessment in a cohort of healthy volunteers and outpatients, as well as assessing the learning curve and patient satisfaction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      64 participants (23 male, 41 female) were consecutively included during the recruitment period, for a total of 51 abdominal and 37 thyroid gland US studies. The mean age was 45.23\u2009\u00b1\u200918.90\u00a0years old, and the body mass index of the abdominal cohort was 22.97\u2009\u00b1\u20092.95\u00a0kg\/m\n                      <jats:sup>2<\/jats:sup>\n                      . The learning curve estimated a minimum of 20 patients for abdominal tele-robotic US training, being almost non-existent in the thyroid gland cohort. All the variables showed no-statistical differences between standard US and tele-robotic US in the abdominal post-trained cohort except the visualization of the left kidney short axis and its interpolar length. Thyroid gland variables showed no statistical differences. The mean time of exploration for the tele-robotic US for abdomen and thyroid gland examinations were 18.33\u2009\u00b1\u20096.26\u00a0min and 4.64\u2009\u00b1\u20090.97\u00a0min respectively. Most participants (&gt;\u200970%) felt comfortable and safe while being examined by the tele-robotic US.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Tele-robotic US achieves equal performance in comparison with the standard US when evaluating abdominal structures in this cohort of patients, as well as a relatively fast learning curve and good patient satisfaction. The performance when assessing the thyroid gland is almost identical to the standard US, which makes it a strong first candidate for a future clinical implementation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13089-025-00408-6","type":"journal-article","created":{"date-parts":[[2025,1,13]],"date-time":"2025-01-13T05:33:51Z","timestamp":1736746431000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Validation of a tele-robotic ultrasound system for abdomen and thyroid gland explorations: a comparison with standard ultrasound"],"prefix":"10.5826","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6973-4246","authenticated-orcid":false,"given":"Andreu","family":"Antolin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6751-7491","authenticated-orcid":false,"given":"Nuria","family":"Roson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3073-4358","authenticated-orcid":false,"given":"Marina","family":"Planes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mar","family":"Castillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Alberti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3794-2224","authenticated-orcid":false,"given":"Manuel","family":"Escobar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27750","published-online":{"date-parts":[[2025,1,13]]},"reference":[{"issue":"6","key":"408_CR1","doi-asserted-by":"publisher","first-page":"e2430920","DOI":"10.2214\/AJR.24.30920","volume":"222","author":"JV Rawson","year":"2024","unstructured":"Rawson JV, Rubin E, Smetherman D (2024) Short-term strategies for augmenting the national radiologist workforce. AJR Am J Roentgenol 222(6):e2430920. https:\/\/doi.org\/10.2214\/AJR.24.30920","journal-title":"AJR Am J Roentgenol"},{"issue":"11","key":"408_CR2","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1016\/j.ijmedinf.2010.08.006","volume":"79","author":"AG Ekeland","year":"2010","unstructured":"Ekeland AG, Bowes A, Flottorp S (2010) Effectiveness of telemedicine: a systematic review of reviews. Int J Med Inform 79(11):736\u2013771. https:\/\/doi.org\/10.1016\/j.ijmedinf.2010.08.006","journal-title":"Int J Med Inform"},{"issue":"3","key":"408_CR3","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/j.mcna.2018.01.002","volume":"102","author":"RS Weinstein","year":"2018","unstructured":"Weinstein RS, Krupinski EA, Doarn CR (2018) Clinical examination component of telemedicine, telehealth, mHealth, and connected health medical practices. Med Clin North Am 102(3):533\u2013544. https:\/\/doi.org\/10.1016\/j.mcna.2018.01.002","journal-title":"Med Clin North Am"},{"key":"408_CR4","doi-asserted-by":"publisher","first-page":"244","DOI":"10.3389\/fpubh.2019.00244","volume":"7","author":"N Britton","year":"2019","unstructured":"Britton N, Miller MA, Safadi S, Siegel A, Levine AR, McCurdy MT (2019) Tele-ultrasound in resource-limited settings: a systematic review. Front Public Health 7:244. https:\/\/doi.org\/10.3389\/fpubh.2019.00244","journal-title":"Front Public Health"},{"issue":"7","key":"408_CR5","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1002\/jum.15525","volume":"40","author":"SJ Adams","year":"2021","unstructured":"Adams SJ, Burbridge B, Obaid H, Stoneham G, Babyn P, Mendez I (2021) Telerobotic sonography for remote diagnostic imaging: narrative review of current developments and clinical applications. J Ultrasound Med 40(7):1287\u20131306. https:\/\/doi.org\/10.1002\/jum.15525","journal-title":"J Ultrasound Med"},{"issue":"11","key":"408_CR6","doi-asserted-by":"publisher","first-page":"e012799","DOI":"10.1136\/bmjopen-2016-01279","volume":"6","author":"JF Cohen","year":"2016","unstructured":"Cohen JF, Korevaar DA, Altman DG et al (2016) STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open 6(11):e012799. https:\/\/doi.org\/10.1136\/bmjopen-2016-01279","journal-title":"BMJ Open"},{"issue":"5","key":"408_CR7","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/j.jacr.2017.01.046","volume":"14","author":"FN Tessler","year":"2017","unstructured":"Tessler FN, Middleton WD, Grant EG et al (2017) ACR thyroid imaging, reporting and data system (TI-RADS): white paper of the ACR TI-RADS committee. J Am Coll Radiol 14(5):587\u2013595. https:\/\/doi.org\/10.1016\/j.jacr.2017.01.046","journal-title":"J Am Coll Radiol"},{"issue":"3","key":"408_CR8","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1007\/s12020-022-03011-0","volume":"76","author":"YQ Zhang","year":"2022","unstructured":"Zhang YQ, Yin HH, He T, Guo LH, Zhao CK, Xu HX (2022) Clinical application of a 5G-based telerobotic ultrasound system for thyroid examination on a rural island: a prospective study. Endocrine 76(3):620\u2013634. https:\/\/doi.org\/10.1007\/s12020-022-03011-0","journal-title":"Endocrine"},{"issue":"1","key":"408_CR9","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1186\/s13054-021-03563-z","volume":"25","author":"S Duan","year":"2021","unstructured":"Duan S, Liu L, Chen Y et al (2021) A 5G-powered robot-assisted teleultrasound diagnostic system in an intensive care unit. Crit Care 25(1):134. https:\/\/doi.org\/10.1186\/s13054-021-03563-z","journal-title":"Crit Care"},{"key":"408_CR10","doi-asserted-by":"publisher","first-page":"102900","DOI":"10.1016\/j.bspc.2021.102900","volume":"70","author":"B Duan","year":"2021","unstructured":"Duan B, Xiong L, Guan X, Fu Y, Zhang Y (2021) Tele-operated robotic ultrasound system for medical diagnosis. Biomed Signal Process Control 70:102900. https:\/\/doi.org\/10.1016\/j.bspc.2021.102900","journal-title":"Biomed Signal Process Control"},{"issue":"3","key":"408_CR11","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/s1361-8415(99)80025-5","volume":"3","author":"F Pierrot","year":"1999","unstructured":"Pierrot F, Dombre E, D\u00e9goulange E et al (1999) Hippocrate: a safe robot arm for medical applications with force feedback. Med Image Anal 3(3):285\u2013300. https:\/\/doi.org\/10.1016\/s1361-8415(99)80025-5","journal-title":"Med Image Anal"},{"issue":"3","key":"408_CR12","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1109\/TRO.2009.2019785","volume":"25","author":"N Koizumi","year":"2009","unstructured":"Koizumi N, Warisawa S, Nagoshi M, Hashizume H, Mitsuishi M (2009) Construction methodology for a remote ultrasound diagnostic system. IEEE Trans Robot 25(3):522\u2013538. https:\/\/doi.org\/10.1109\/TRO.2009.2019785","journal-title":"IEEE Trans Robot"},{"key":"408_CR13","doi-asserted-by":"publisher","first-page":"212","DOI":"10.3233\/978-1-60750-939-4-212","volume":"95","author":"A Vilchis","year":"2003","unstructured":"Vilchis A, Masuda K, Troccaz J, Cinquin P (2003) Robot-based tele-echography: the TER system. Stud Health Technol Inform 95:212\u2013217. https:\/\/doi.org\/10.3233\/978-1-60750-939-4-212","journal-title":"Stud Health Technol Inform"},{"issue":"3","key":"408_CR14","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.carj.2016.08.002","volume":"68","author":"SJ Adams","year":"2017","unstructured":"Adams SJ, Burbridge BE, Badea A et al (2017) Initial experience using a telerobotic ultrasound system for adult abdominal sonography. Can Assoc Radiol J 68(3):308\u2013314. https:\/\/doi.org\/10.1016\/j.carj.2016.08.002","journal-title":"Can Assoc Radiol J"},{"issue":"11","key":"408_CR15","doi-asserted-by":"publisher","first-page":"2603","DOI":"10.1002\/jum.14619","volume":"37","author":"SJ Adams","year":"2018","unstructured":"Adams SJ, Burbridge BE, Badea A et al (2018) A crossover comparison of standard and telerobotic approaches to prenatal sonography. J Ultrasound Med 37(11):2603\u20132612. https:\/\/doi.org\/10.1002\/jum.14619","journal-title":"J Ultrasound Med"},{"key":"408_CR16","doi-asserted-by":"publisher","first-page":"102878","DOI":"10.1016\/j.media.2023.102878","volume":"89","author":"Z Jiang","year":"2023","unstructured":"Jiang Z, Salcudean SE, Navab N (2023) Robotic ultrasound imaging: state-of-the-art and future perspectives. Med Image Anal 89:102878. https:\/\/doi.org\/10.1016\/j.media.2023.102878","journal-title":"Med Image Anal"},{"issue":"7","key":"408_CR17","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1016\/s0301-5629(03)00063-2","volume":"29","author":"P Arbeille","year":"2003","unstructured":"Arbeille P, Poisson G, Vieyres P, Ayoub J, Porcher M, Boulay JL (2003) Echographic examination in isolated sites controlled from an expert center using a 2-D echograph guided by a teleoperated robotic arm. Ultrasound Med Biol 29(7):993\u20131000. https:\/\/doi.org\/10.1016\/s0301-5629(03)00063-2","journal-title":"Ultrasound Med Biol"},{"issue":"Suppl 1","key":"408_CR18","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1258\/1357633054461552","volume":"11","author":"F Courreges","year":"2005","unstructured":"Courreges F, Vieyres P, Istepanian RS, Arbeille P, Bru C (2005) Clinical trials and evaluation of a mobile, robotic tele-ultrasound system. J Telemed Telecare 11(Suppl 1):46\u201349. https:\/\/doi.org\/10.1258\/1357633054461552","journal-title":"J Telemed Telecare"},{"issue":"11","key":"408_CR19","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.7863\/jum.2007.26.11.1611","volume":"26","author":"T Martinelli","year":"2007","unstructured":"Martinelli T, Bosson JL, Bressollette L et al (2007) Robot-based tele-echography: clinical evaluation of the TER system in abdominal aortic exploration. J Ultrasound Med 26(11):1611\u20131616. https:\/\/doi.org\/10.7863\/jum.2007.26.11.1611","journal-title":"J Ultrasound Med"},{"issue":"4","key":"408_CR20","doi-asserted-by":"publisher","first-page":"W317","DOI":"10.2214\/AJR.05.0469","volume":"188","author":"P Arbeille","year":"2007","unstructured":"Arbeille P, Capri A, Ayoub J, Kieffer V, Georgescu M, Poisson G (2007) Use of a robotic arm to perform remote abdominal telesonography. AJR Am J Roentgenol 188(4):W317\u2013W322. https:\/\/doi.org\/10.2214\/AJR.05.0469","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"408_CR21","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.jacr.2021.07.023","volume":"19","author":"SJ Adams","year":"2022","unstructured":"Adams SJ, Burbridge B, Chatterson L, Babyn P, Mendez I (2022) A telerobotic ultrasound clinic model of ultrasound service delivery to improve access to imaging in rural and remote communities. J Am Coll Radiol 19(1):162\u2013171. https:\/\/doi.org\/10.1016\/j.jacr.2021.07.023","journal-title":"J Am Coll Radiol"},{"issue":"3","key":"408_CR22","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1007\/s00261-023-04123-5","volume":"49","author":"YQ Zhang","year":"2024","unstructured":"Zhang YQ, Sun LP, He T et al (2024) A 5G-based telerobotic ultrasound system provides qualified abdominal ultrasound services for patients on a rural island: a prospective and comparative study of 401 patients. Abdom Radiol 49(3):942\u2013957. https:\/\/doi.org\/10.1007\/s00261-023-04123-5","journal-title":"Abdom Radiol"},{"issue":"3","key":"408_CR23","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1002\/jum.16041","volume":"42","author":"W Jiang","year":"2023","unstructured":"Jiang W, Zhao X, Gan T et al (2023) Application of a tele-ultrasound robot during COVID-19 pandemic: a feasibility study. J Ultrasound Med 42(3):595\u2013601. https:\/\/doi.org\/10.1002\/jum.16041","journal-title":"J Ultrasound Med"},{"key":"408_CR24","doi-asserted-by":"publisher","first-page":"915071","DOI":"10.3389\/fpubh.2022.915071","volume":"10","author":"HH Chai","year":"2022","unstructured":"Chai HH, Ye RZ, Xiong LF et al (2022) Successful use of a 5G-based robot-assisted remote ultrasound system in a care center for disabled patients in rural China. Front Public Health 10:915071. https:\/\/doi.org\/10.3389\/fpubh.2022.915071","journal-title":"Front Public Health"},{"key":"408_CR25","doi-asserted-by":"publisher","first-page":"1149964","DOI":"10.3389\/fpubh.2023.1149964","volume":"11","author":"JY Ren","year":"2023","unstructured":"Ren JY, Lei YM, Lei BS et al (2023) The feasibility and satisfaction study of 5G-based robotic teleultrasound diagnostic system in health check-ups. Front Public Health 11:1149964. https:\/\/doi.org\/10.3389\/fpubh.2023.1149964","journal-title":"Front Public Health"},{"issue":"5","key":"408_CR26","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1089\/tmj.2008.0148","volume":"15","author":"C L\u00f6fgren","year":"2009","unstructured":"L\u00f6fgren C, Boman K, Olofsson M, Lindholm L (2009) Is cardiac consultation with remote-controlled real-time echocardiography a wise use of resources? Telemed J E Health 15(5):431\u2013438. https:\/\/doi.org\/10.1089\/tmj.2008.0148","journal-title":"Telemed J E Health"},{"issue":"1","key":"408_CR27","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1002\/jum.16070","volume":"42","author":"SJ Adams","year":"2023","unstructured":"Adams SJ, Penz E, Imeah B et al (2023) Economic evaluation of telerobotic ultrasound technology to remotely provide ultrasound services in rural and remote communities. J Ultrasound Med 42(1):109\u2013123. https:\/\/doi.org\/10.1002\/jum.16070","journal-title":"J Ultrasound Med"},{"issue":"4","key":"408_CR28","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1177\/021849230701500411","volume":"15","author":"P Sekar","year":"2007","unstructured":"Sekar P, Vilvanathan V (2007) Telecardiology: effective means of delivering cardiac care to rural children. Asian Cardiovasc Thorac Ann 15(4):320\u2013323. https:\/\/doi.org\/10.1177\/021849230701500411","journal-title":"Asian Cardiovasc Thorac Ann"}],"container-title":["The Ultrasound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-025-00408-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13089-025-00408-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13089-025-00408-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T12:05:24Z","timestamp":1773662724000},"score":1,"resource":{"primary":{"URL":"https:\/\/mattioli1885journals.com\/index.php\/theultrasoundjournal\/article\/view\/18107"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,13]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["408"],"URL":"https:\/\/doi.org\/10.1186\/s13089-025-00408-6","relation":{},"ISSN":["2524-8987"],"issn-type":[{"value":"2524-8987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,13]]},"assertion":[{"value":"23 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional Review Board approval was obtained from the Ethical Committee of Hospital Universitari Vall Hebron from Barcelona (Comit\u00e8 d'\u00c8tica de la Investigaci\u00f3 amb Medicaments (CEIm)) with the following code: PR(IDI)353\/2022. Informed Consent was obtained according to the hospital Ethic Committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed Consent was obtained according to the hospital Ethic Committee.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2"}}