{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:45:43Z","timestamp":1792788343408,"version":"4.5.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Office of the Under Secretary of Defense for Health Affairs","award":["W81XWH1910591"],"award-info":[{"award-number":["W81XWH1910591"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Res Notes"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      Doppler ultrasonography of the common carotid artery is used to infer stroke volume change and a wearable Doppler ultrasound has been designed to improve this workflow. Previously, in a human model of hemorrhage and resuscitation comprising approximately 50,000 cardiac cycles, we found a strong, linear correlation between changing stroke volume, and measures from the carotid Doppler signal, however, optimal Doppler thresholds for detecting a 10% stroke volume change were not reported. In this\n                      <jats:italic>Research Note<\/jats:italic>\n                      , we present these thresholds, their sensitivities, specificities and areas under their receiver operator curves (AUROC).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Augmentation of carotid artery maximum velocity time integral and corrected flowtime by 18% and 4%, respectively, accurately captured 10% stroke volume rise. The sensitivity and specificity for these thresholds were identical at 89% and 100%. These data are similar to previous investigations in healthy volunteers monitored by the wearable ultrasound.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13104-021-05896-y","type":"journal-article","created":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T08:03:58Z","timestamp":1641801838000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Carotid artery velocity time integral and corrected flow time measured by a wearable Doppler ultrasound detect stroke volume rise from simulated hemorrhage to transfusion"],"prefix":"10.1186","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3654-1146","authenticated-orcid":false,"given":"Jon-\u00c9mile S.","family":"Kenny","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Barjaktarevic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David C.","family":"Mackenzie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai","family":"Elfarnawany","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew M.","family":"Eibl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph K.","family":"Eibl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chul-Ho","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce D.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,10]]},"reference":[{"issue":"1","key":"5896_CR1","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1186\/s13054-021-03498-5","volume":"25","author":"J-ES Kenny","year":"2021","unstructured":"Kenny J-ES, Barjaktarevic I. Letter to the editor: stroke volume is the key measure of fluid responsiveness. Crit Care. 2021;25(1):104.","journal-title":"Crit Care"},{"issue":"5","key":"5896_CR2","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1053\/j.jvca.2021.01.040","volume":"35","author":"J-\u00c9S Kenny","year":"2021","unstructured":"Kenny J-\u00c9S. Functional hemodynamic monitoring with a wireless ultrasound patch. J Cardiothorac Vasc Anesth. 2021;35(5):1509\u201315.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"2","key":"5896_CR3","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1378\/chest.12-1274","volume":"143","author":"PE Marik","year":"2013","unstructured":"Marik PE, Levitov A, Young A, Andrews L. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest. 2013;143(2):364\u201370.","journal-title":"Chest"},{"key":"5896_CR4","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1097\/CCM.0000000000003356","volume":"11","author":"I Barjaktarevic","year":"2018","unstructured":"Barjaktarevic I, Toppen WE, Hu S, Montoya EA, Ong S, Buhr R, et al. Ultrasound assessment of the change in carotid corrected flow time in fluid responsiveness in undifferentiated shock. Crit Care Med. 2018;11:1040\u20136.","journal-title":"Crit Care Med"},{"issue":"10","key":"5896_CR5","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1002\/jum.15301","volume":"39","author":"L Beier","year":"2020","unstructured":"Beier L, Davis J, Esener D, Grant C, Fields JM. Carotid ultrasound to predict fluid responsiveness: a systematic review. J Ultrasound Med. 2020;39(10):1965\u201376.","journal-title":"J Ultrasound Med"},{"issue":"6","key":"5896_CR6","doi-asserted-by":"publisher","first-page":"e0439","DOI":"10.1097\/CCE.0000000000000439","volume":"3","author":"J-\u00c9S Kenny","year":"2021","unstructured":"Kenny J-\u00c9S, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Math ZYB, Eibl AM, et al. Carotid Doppler measurement variability in functional hemodynamic monitoring: an analysis of 17,822 cardiac cycles. Crit Care Explor. 2021;3(6):e0439.","journal-title":"Crit Care Explor."},{"issue":"1","key":"5896_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-79139-8","volume":"11","author":"J-\u00c9S Kenny","year":"2021","unstructured":"Kenny J-\u00c9S, Munding CE, Eibl JK, Eibl AM, Long BF, Boyes A, et al. A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery. Sci Rep. 2021;11(1):1\u201311.","journal-title":"Sci Rep"},{"issue":"2","key":"5896_CR8","doi-asserted-by":"publisher","first-page":"e60-e3","DOI":"10.1016\/j.bja.2021.05.007","volume":"127","author":"J-\u00c9S Kenny","year":"2021","unstructured":"Kenny J-\u00c9S, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Yang Z, Eibl AM, et al. Carotid Doppler ultrasonography correlates with stroke volume in a human model of hypovolaemia and resuscitation: analysis of 48570 cardiac cycles. Br J Anaesth. 2021;127(2):e60\u20133.","journal-title":"Br J Anaesth"},{"issue":"1","key":"5896_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40635-019-0284-8","volume":"8","author":"J-\u00c9S Kenny","year":"2020","unstructured":"Kenny J-\u00c9S, Barjaktarevic I, Mackenzie DC, Eibl AM, Parrotta M, Long BF, et al. Diagnostic characteristics of 11 formulae for calculating corrected flow time as measured by a wearable Doppler patch. Intensiv Care Med Exp. 2020;8(1):1\u201311.","journal-title":"Intensiv Care Med Exp."},{"issue":"1","key":"5896_CR10","doi-asserted-by":"publisher","first-page":"e0072","DOI":"10.1097\/CCE.0000000000000072","volume":"2","author":"J\u00c9S Kenny","year":"2020","unstructured":"Kenny J\u00c9S, Barjaktarevic I, Eibl AM, Parrotta M, Long BF, Eibl JK, et al. A carotid Doppler patch accurately tracks stroke volume changes during a preload-modifying maneuver in healthy volunteers. Crit Care Explor. 2020;2(1):e0072.","journal-title":"Crit Care Explor."},{"issue":"1","key":"5896_CR11","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1186\/s13054-018-2171-1","volume":"22","author":"S Magder","year":"2018","unstructured":"Magder S. The meaning of blood pressure. Crit Care. 2018;22(1):257.","journal-title":"Crit Care"},{"issue":"1","key":"5896_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0301-5629(94)00090-5","volume":"21","author":"F Hansen","year":"1995","unstructured":"Hansen F, Mangell P, Sonesson B, L\u00e4nne T. Diameter and compliance in the human common carotid artery\u2014variations with age and sex. Ultrasound Med Biol. 1995;21(1):1\u20139.","journal-title":"Ultrasound Med Biol"},{"key":"5896_CR13","first-page":"94","volume-title":"Clinical Applications of Doppler Ultrasound, Ch 4","author":"KJW Taylor","year":"1995","unstructured":"Taylor KJW, Burns PN, Wells PNT. Clinical Applications of Doppler Ultrasound, Ch 4. 2nd ed. Raven Press; 1995. p. 94.","edition":"2"},{"issue":"2","key":"5896_CR14","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1097\/01.CCM.0000254725.35802.17","volume":"35","author":"X Monnet","year":"2007","unstructured":"Monnet X, Chemla D, Osman D, Anguel N, Richard C, Pinsky MR, et al. Measuring aortic diameter improves accuracy of esophageal Doppler in assessing fluid responsiveness. Crit Care Med. 2007;35(2):477\u201382.","journal-title":"Crit Care Med"},{"issue":"3","key":"5896_CR15","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1097\/MCC.0000000000000198","volume":"21","author":"K Ameloot","year":"2015","unstructured":"Ameloot K, Palmers P-J, Malbrain ML. The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review. Curr Opin Crit Care. 2015;21(3):232\u20139.","journal-title":"Curr Opin Crit Care."},{"issue":"1","key":"5896_CR16","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.bja.2020.03.013","volume":"125","author":"B Saugel","year":"2020","unstructured":"Saugel B, Hoppe P, Nicklas JY, Kouz K, K\u00f6rner A, Hempel JC, et al. Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis. Br J Anaesth. 2020;125(1):25\u201337.","journal-title":"Br J Anaesth"},{"issue":"2","key":"5896_CR17","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.autneu.2004.02.007","volume":"111","author":"VA Convertino","year":"2004","unstructured":"Convertino VA, Ludwig DA, Cooke WH. Stroke volume and sympathetic responses to lower-body negative pressure reveal new insight into circulatory shock in humans. Auton Neurosci. 2004;111(2):127\u201334.","journal-title":"Auton Neurosci"},{"issue":"5","key":"5896_CR18","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1152\/japplphysiol.01009.2017","volume":"124","author":"M Skytioti","year":"2018","unstructured":"Skytioti M, S\u00f8vik S, Elstad M. Respiratory pump maintains cardiac stroke volume during hypovolemia in young, healthy volunteers. J Appl Physiol. 2018;124(5):1319\u201325.","journal-title":"J Appl Physiol"},{"issue":"8","key":"5896_CR19","first-page":"839","volume":"82","author":"M Vettorello","year":"2016","unstructured":"Vettorello M, Sher S, Santambrogio S, Calini A, Tardini F, Lippi M, et al. Validation of a novel index of hemorrhage using a lower body negative pressure shock model. Minerva Anestesiol. 2016;82(8):839\u201349.","journal-title":"Minerva Anestesiol"},{"issue":"3","key":"5896_CR20","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1097\/01.ta.0000196663.34175.33","volume":"61","author":"VA Convertino","year":"2006","unstructured":"Convertino VA, Cooke WH, Holcomb JB. Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia. J Trauma Acute Care Surg. 2006;61(3):629\u201334.","journal-title":"J Trauma Acute Care Surg"},{"issue":"4","key":"5896_CR21","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1007\/s00134-010-2128-6","volume":"37","author":"SA Bartels","year":"2011","unstructured":"Bartels SA, Bezemer R, de Vries FJW, Milstein DM, Lima A, Cherpanath TG, et al. Multi-site and multi-depth near-infrared spectroscopy in a model of simulated (central) hypovolemia: lower body negative pressure. Intensive Care Med. 2011;37(4):671\u20137.","journal-title":"Intensive Care Med"}],"container-title":["BMC Research Notes"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13104-021-05896-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13104-021-05896-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13104-021-05896-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T08:21:09Z","timestamp":1641802869000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcresnotes.biomedcentral.com\/articles\/10.1186\/s13104-021-05896-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,10]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5896"],"URL":"https:\/\/doi.org\/10.1186\/s13104-021-05896-y","relation":{},"ISSN":["1756-0500"],"issn-type":[{"value":"1756-0500","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,10]]},"assertion":[{"value":"12 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Research Ethics Board of the Mayo Clinic (IRB number 19-010136); written and informed consent was obtained for all subjects.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"JESK, ME, ZY, AME, JKE are employees of Flosonics Medical, a start-up building the wearable ultrasound, IB reports consulting fees for GE Healthcare, DCM, CHK and BDJ report no conflicts.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"7"}}