{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T15:39:49Z","timestamp":1740152389399,"version":"3.37.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:00:00Z","timestamp":1721174400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:00:00Z","timestamp":1721174400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003593","name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003593","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002322","name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Res Notes"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>Conical orthopedic drill bits may have the potential to improve the stabilization of orthopedic screws. During perforations, heat energy is released, and elevated temperatures could be related to thermal osteonecrosis. This study was designed to evaluate the thermal behavior of an experimental conical drill bit, when compared to the conventional cylindrical drill, using polyurethane blocks perforations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The sample was divided into two groups, according to the method of drilling, including 25 polyurethane blocks in each: In Group 1, perforations were performed with a conventional orthopedic cylindrical drill; while in Group 2, an experimental conical drill was used. No statistically significant difference was observed in relation to the maximum temperature (MT) during the entire drilling in the groups, however the perforation time (PT) was slightly longer in Group 2. Each drill bit perforated five times and number of perforations was not correlated with a temperature increase, when evaluated universally or isolated by groups. The PT had no correlation with an increase in temperature when evaluating the perforations universally (<jats:italic>n<\/jats:italic>\u2009=\u200950) and in Group 1 alone; however, Group 2 showed an inversely proportional correlation for these variables, indicating that, for the conical drill bit, drillings with longer PT had lower MT.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13104-024-06862-0","type":"journal-article","created":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T18:02:39Z","timestamp":1721239359000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Thermographic analysis of perforations in polyurethane blocks performed with experimental conical drill bit in comparison to conventional orthopedic drill bit: a preliminary study"],"prefix":"10.1186","volume":"17","author":[{"given":"In\u00e1cio Bernhardt","family":"Rovaris","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anderson Luiz","family":"de Carvalho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriel Aardewijn","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel Guimar\u00e3es","family":"Gerardi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcelo Meller","family":"Alievi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,17]]},"reference":[{"issue":"7","key":"6862_CR1","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1111\/jsap.13484","volume":"63","author":"E Kvale","year":"2022","unstructured":"Kvale E, Kalmukov I, Grassato L, Kalff S, Solano M. Epicondylar plate fixation of humeral condylar fractures in immature French bulldogs: 45 cases (2014\u20132020). J Small Anim Pract. 2022;63(7):532\u201341. https:\/\/doi.org\/10.1111\/jsap.13484","journal-title":"J Small Anim Pract"},{"issue":"1","key":"6862_CR2","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1055\/s-0042-1756514","volume":"36","author":"O Gilman","year":"2023","unstructured":"Gilman O, Escauriaza L, Ogden D, Vandenberghe H, Roper D, Oxley B, Granger N. Thoracolumbar spinal stabilization with three dimensional-printed drill guides and pre-contoured polyaxial bone plates. Vet Comp Orthop Traumatol. 2023;36(1):46\u201352. https:\/\/doi.org\/10.1055\/s-0042-1756514","journal-title":"Vet Comp Orthop Traumatol"},{"doi-asserted-by":"publisher","unstructured":"Kot CCS, Verstraete FJM, Garcia TC, Stover SM, Arzi B. Biomechanical evaluation of locking versus nonlocking 2.0-mm malleable L-miniplate fixation of simulated caudal mandibular fractures in cats. Am J Vet Res. 2022;29(8):ajvr.22.03.0043. https:\/\/doi.org\/10.2460\/ajvr.22.03.0043","key":"6862_CR3","DOI":"10.2460\/ajvr.22.03.0043"},{"key":"6862_CR4","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s13246-020-00842-x","volume":"43","author":"E Shakouri","year":"2020","unstructured":"Shakouri E, Nezhad MG. An in vitro study of bone drilling: infrared thermography and evaluation of thermal changes of bone and drill bit. Phys Eng Sci Med. 2020;43:247\u201357. https:\/\/doi.org\/10.1007\/s13246-020-00842-x","journal-title":"Phys Eng Sci Med"},{"key":"6862_CR5","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.medengphy.2020.05.014","volume":"83","author":"L Shu","year":"2020","unstructured":"Shu L, Bai W, Shimada T, Ying Z, Li S, Sugita N. Thermographic assessment of heat-induced cellular damage during orthopedic surgery. Med Eng Phys. 2020;83:100\u20135. https:\/\/doi.org\/10.1016\/j.medengphy.2020.05.014","journal-title":"Med Eng Phys"},{"issue":"4","key":"6862_CR6","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","volume":"27","author":"G Augustin","year":"2012","unstructured":"Augustin G, Zigman T, Davila S, Udilljak T, Staroveski T, Brezak D, Babic S. Cortical bone drilling and thermal osteonecrosis. Clin Biomech. 2012;27(4):313\u201325. https:\/\/doi.org\/10.1016\/j.clinbiomech.2011.10.010","journal-title":"Clin Biomech"},{"issue":"1","key":"6862_CR7","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1177\/1943387520904212","volume":"14","author":"VK Kumar","year":"2021","unstructured":"Kumar VK, Prasad K, Sansgiri T, Ranganath K, Shwetha V, Al-Khuteja K. Self-drilling versus self-tapping screws: a 3D finite element analysis. Craniomaxillofac Trauma Reconstr. 2021;14(1):4\u201310. https:\/\/doi.org\/10.1177\/1943387520904212","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"6862_CR8","doi-asserted-by":"publisher","first-page":"6234","DOI":"10.1038\/s41598-023-33381-y","volume":"13","author":"K Alam","year":"2023","unstructured":"Alam K, Qamar SZ, Iqbal M, Piya S, Al-Kindi M, Qureshi A, et al. Effect of drill quality on biological damage in bone drilling. Sci Rep. 2023;13:6234. https:\/\/doi.org\/10.1038\/s41598-023-33381-y","journal-title":"Sci Rep"},{"issue":"4","key":"6862_CR9","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1080\/10910344.2013.837353","volume":"17","author":"J Soriano","year":"2013","unstructured":"Soriano J, Garay A, Aristimu\u00f1o P, Iriarte LM, Eguren JA, Arrazola PJ. Effects of rotational speed, feed rate and tool type on temperatures and cutting forces when drilling bovine cortical bone. Mach Sci Technol. 2013;17(4):611\u201336. https:\/\/doi.org\/10.1080\/10910344.2013.837353","journal-title":"Mach Sci Technol"},{"issue":"5","key":"6862_CR10","doi-asserted-by":"publisher","first-page":"69","DOI":"10.24243\/jmeb\/2.5.170","volume":"2","author":"MG Fernandes","year":"2018","unstructured":"Fernandes MG, Fonseca EM, Jorge RN, C\u00e9spedes MCM, Dias MI. Effect of drill speed on the strain distribution during drilling of bovine and human bones. J Biomech Eng. 2018;2(5):69\u201374. https:\/\/doi.org\/10.24243\/jmeb\/2.5.170","journal-title":"J Biomech Eng"},{"doi-asserted-by":"publisher","unstructured":"Ghazali M, Roseiro L, Garru\u00e7o A, Margalho L, Expedito F. Pre-drilling vs. self-drilling of pin bone insertion\u2013a thermography experimental evaluation. In: Tavares J, Natal Jorge R, editors. Lecture Notes in Computation Vision and Biomechanics. 2018. https:\/\/doi.org\/10.1007\/978-3-319-68195-5_118","key":"6862_CR11","DOI":"10.1007\/978-3-319-68195-5_118"},{"issue":"7","key":"6862_CR12","doi-asserted-by":"publisher","first-page":"e5226","DOI":"10.7759\/cureus.5226","volume":"11","author":"C Timon","year":"2019","unstructured":"Timon C, Keady C. Thermal osteonecrosis caused by bone drilling in orthopedic surgery: a literature review. Cureus. 2019;11(7):e5226. https:\/\/doi.org\/10.7759\/cureus.5226","journal-title":"Cureus"},{"key":"6862_CR13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.jor.2023.10.013","volume":"46","author":"\u00d6 Pazarc\u0131","year":"2023","unstructured":"Pazarc\u0131 \u00d6, G\u00fcndo\u011fdu F. Temperature change during orthopedic drilling procedures: an experimental surgical internal fixation simulation study. J Orthop. 2023;46:58\u201363. https:\/\/doi.org\/10.1016\/j.jor.2023.10.013","journal-title":"J Orthop"},{"issue":"2","key":"6862_CR14","doi-asserted-by":"publisher","first-page":"e0229328","DOI":"10.1371\/journal.pone.0229328","volume":"15","author":"MY Liu","year":"2020","unstructured":"Liu MY, Tsai TT, Lai PL, Hsieh MK, Chen LH, Tai CL. Biomechanical comparison of pedicle screw fixation strength in synthetic bones: effects of screw shape, core\/thread profile and cement augmentation. PLoS ONE. 2020;15(2):e0229328. https:\/\/doi.org\/10.1371\/journal.pone.0229328","journal-title":"PLoS ONE"},{"issue":"7","key":"6862_CR15","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1097\/BOT.0000000000002329","volume":"36","author":"CW Hodgkins","year":"2022","unstructured":"Hodgkins CW, Fleites J. Fibula nailing: a retrospective review of 110 consecutive FibuLock nails. J Orthop Trauma. 2022;36(7):366\u20139. https:\/\/doi.org\/10.1097\/BOT.0000000000002329","journal-title":"J Orthop Trauma"},{"issue":"1","key":"6862_CR16","doi-asserted-by":"publisher","first-page":"103242","DOI":"10.1016\/j.otsr.2022.103242","volume":"109","author":"M Shahin","year":"2023","unstructured":"Shahin M, Mass\u00e9 V, Belzile \u00c9, B\u00e9dard L, Angers M, Vendittoli PA. Midterm results of titanium conical Wagner stem with challenging femoral anatomy: survivorship and unique bone remodeling. Orthop Traumatol Surg Res. 2023;109(1):103242. https:\/\/doi.org\/10.1016\/j.otsr.2022.103242","journal-title":"Orthop Traumatol Surg Res"},{"unstructured":"Associa\u00e7\u00e3o Brasileira de Normas T\u00e9cnicas (ABNT). NBR 15678:2020. Implantes para cirurgia - Espuma r\u00edgida de poliuretano para ensaio de implantes e instrumentos - Requisitos, classifica\u00e7\u00e3o e m\u00e9todos de ensaio (Implants for surgery - Rigid polyurethane foam for implants and instruments testing - Requirements, classification and test methods). 2020. https:\/\/www.abntcatalogo.com.br\/pnm.aspx?Q=R3B0TnlLVCt2cTZCMmRzcUg2UVhPZ01IOUsxaGRpMkZJbjJMNW9RWE9kYz0=. Accessed 9 Dez 2023.","key":"6862_CR17"},{"unstructured":"Associa\u00e7\u00e3o Brasileira de Normas T\u00e9cnicas (ABNT). NBR 15675-4:2009. Implantes para ortopedia - Parafusos \u00f3sseos met\u00e1licos. Parte 4: M\u00e9todo de ensaio para determina\u00e7\u00e3o da resist\u00eancia ao arrancamento axial (Orthopedics implants - Metallic bone screws. Part 4: Test method for determining the axial pullout strength). 2009. https:\/\/www.abntcatalogo.com.br\/pnm.aspx?Q=OXBEUm1jMG8rbWxOdFdwbTE0UmRHUFhrR1pDNHNIbkNHeVZ6akMwclRvcz0=. Accessed 9 Dez 2023.","key":"6862_CR18"},{"key":"6862_CR19","doi-asserted-by":"publisher","first-page":"20737","DOI":"10.1038\/s41598-020-77762-z","volume":"10","author":"SA Gehrke","year":"2020","unstructured":"Gehrke SA, Treichel TLE, Arambur\u00fa J\u00fanior J, de Aza PN, Prados-Frutos JC. Effects of the technique and drill design used during the osteotomy on the thermal and histological stimulation. Sci Rep. 2020;10:20737. https:\/\/doi.org\/10.1038\/s41598-020-77762-z","journal-title":"Sci Rep"},{"issue":"1","key":"6862_CR20","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/0278-2391(86)90006-6","volume":"44","author":"RA Eriksson","year":"1986","unstructured":"Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg. 1986;44(1):4\u20137. https:\/\/doi.org\/10.1016\/0278-2391(86)90006-6","journal-title":"J Oral Maxillofac Surg"},{"issue":"1","key":"6862_CR21","doi-asserted-by":"publisher","first-page":"148","DOI":"10.3390\/jcm9010148","volume":"9","author":"A Scarano","year":"2020","unstructured":"Scarano A, Lorusso F, Noumbissi S. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with steel vs. Zirconia implant drill. J Clin Med. 2020;9(1):148. https:\/\/doi.org\/10.3390\/jcm9010148","journal-title":"J Clin Med"},{"key":"6862_CR22","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/j.medengphy.2020.01.007","volume":"78","author":"J Sui","year":"2020","unstructured":"Sui J, Wang C, Sugita N. Experimental study of temperature rise during bone drilling process. Med Eng Phys. 2020;78:64\u201373. https:\/\/doi.org\/10.1016\/j.medengphy.2020.01.007","journal-title":"Med Eng Phys"},{"issue":"1","key":"6862_CR23","doi-asserted-by":"publisher","first-page":"11817","DOI":"10.1038\/s41598-019-48416-6","volume":"9","author":"J Szalma","year":"2019","unstructured":"Szalma J, Lov\u00e1sz BV, Vajta L, So\u00f3s B, Lempel E, M\u00f6hlhenrich SC. The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times. Sci Rep. 2019;9(1):11817. https:\/\/doi.org\/10.1038\/s41598-019-48416-6","journal-title":"Sci Rep"},{"key":"6862_CR24","doi-asserted-by":"publisher","first-page":"1855","DOI":"10.1007\/s40430-016-0560-4","volume":"38","author":"MGA Fernandes","year":"2016","unstructured":"Fernandes MGA, Fonseca EMM, Natal. Thermal analysis during bone drilling using rigid polyurethane foams: numerical and experimental methodologies. J Braz Soc Mech Sci Eng. 2016;38:1855\u201363. https:\/\/doi.org\/10.1007\/s40430-016-0560-4","journal-title":"J Braz Soc Mech Sci Eng"},{"unstructured":"Teixeira TAS, Fernandes MG, Azevedo LD, Fonseca EMM, Jorge RN. Influence of drill bit diameter on drilling of polyurethane foams. Proceedings of the 7th International Conference on Mechanics and Materials in Design. 2017:843\u2013852.","key":"6862_CR25"}],"container-title":["BMC Research Notes"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13104-024-06862-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13104-024-06862-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13104-024-06862-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T18:03:36Z","timestamp":1721239416000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcresnotes.biomedcentral.com\/articles\/10.1186\/s13104-024-06862-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,17]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["6862"],"URL":"https:\/\/doi.org\/10.1186\/s13104-024-06862-0","relation":{},"ISSN":["1756-0500"],"issn-type":[{"type":"electronic","value":"1756-0500"}],"subject":[],"published":{"date-parts":[[2024,7,17]]},"assertion":[{"value":"21 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"197"}}