{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T19:54:02Z","timestamp":1790452442814,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,8]],"date-time":"2022-10-08T00:00:00Z","timestamp":1665187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,8]],"date-time":"2022-10-08T00:00:00Z","timestamp":1665187200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"2021 Key clinical Specialty Program of Beijing, Beijing Municipal Key Clinical Specialty Excellence Program"},{"name":"Clinical and Translational Research Project of Chinese Academy of Medical Sciences","award":["2019XK320028"],"award-info":[{"award-number":["2019XK320028"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81901742"],"award-info":[{"award-number":["81901742"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["91859119"],"award-info":[{"award-number":["91859119"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Public Welfare Basic Scientific Research Project of Chinese Academy of Medical Sciences","award":["2019PT320008"],"award-info":[{"award-number":["2019PT320008"]}]},{"name":"National Public Welfare Basic Scientific Research Project of Chinese Academy of Medical Sciences","award":["2018PT32003"],"award-info":[{"award-number":["2018PT32003"]}]},{"name":"National High Level Hospital Clinical Research Funding","award":["2022-PUMCH-A-033"],"award-info":[{"award-number":["2022-PUMCH-A-033"]}]},{"name":"National High Level Hospital Clinical Research Funding","award":["2022-PUMCH-A-035"],"award-info":[{"award-number":["2022-PUMCH-A-035"]}]},{"name":"Chinese Academy of Medical Sciences innovation fund for medical sciences","award":["CIFMS 2021-I2M-C&T-B-022"],"award-info":[{"award-number":["CIFMS 2021-I2M-C&T-B-022"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Renal calculi are a common and recurrent urological disease and are usually detected by CT. In this study, we evaluated the diagnostic capability, image quality, and radiation dose of abdominal ultra-low-dose CT (ULDCT) with deep learning reconstruction (DLR) for detecting renal calculi.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Sixty patients with suspected renal calculi were prospectively enrolled. Low-dose CT (LDCT) images were reconstructed with hybrid iterative reconstruction (LD-HIR) and was regarded as the standard for stone and lesion detection. ULDCT images were reconstructed with HIR (ULD-HIR) and DLR (ULD-DLR). We then compared stone detection rate, abdominal lesion detection rate, image quality and radiation dose between LDCT and ULDCT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 130 calculi were observed on LD-HIR images. Stone detection rates of ULD-HIR and ULD-DLR images were 93.1% (121\/130) and 95.4% (124\/130). A total of 129 lesions were detected on the LD-HIR images. The lesion detection rate on ULD-DLR images was 92.2%, with 10 cysts\u2009&lt;\u20095\u00a0mm in diameter missed. The CT values of organs on ULD-DLR were similar to those on LD-HIR and lower than those on ULD-HIR. Signal-to-noise ratio was highest and noise lowest on ULD-DLR. The subjective image quality of ULD-DLR was similar to that of LD-HIR and better than that of ULD-HIR. The effective radiation dose of ULDCT (0.64\u2009\u00b1\u20090.17\u00a0mSv) was 77% lower than that of LDCT (2.75\u2009\u00b1\u20090.50\u00a0mSv).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>ULDCT combined with DLR could significantly reduce radiation dose while maintaining suitable image quality and stone detection rate in the diagnosis of renal calculi.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13244-022-01300-w","type":"journal-article","created":{"date-parts":[[2022,10,8]],"date-time":"2022-10-08T14:02:35Z","timestamp":1665237755000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Application of deep learning reconstruction of ultra-low-dose abdominal CT in the diagnosis of renal calculi"],"prefix":"10.1186","volume":"13","author":[{"given":"Xiaoxiao","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gumuyang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lili","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiahui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daming","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengyu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9606-9066","authenticated-orcid":false,"given":"Hao","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,8]]},"reference":[{"issue":"2","key":"1300_CR1","first-page":"51","volume":"10","author":"S Alatab","year":"2016","unstructured":"Alatab S, Pourmand G, El Howairis MF et al (2016) National profiles of urinary calculi: a comparison between developing and developed worlds. Iran J Kidney Dis 10(2):51\u201361","journal-title":"Iran J Kidney Dis"},{"issue":"9507","key":"1300_CR2","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/S0140-6736(06)68071-9","volume":"367","author":"OW Moe","year":"2006","unstructured":"Moe OW (2006) Kidney stones: pathophysiology and medical management. Lancet 367(9507):333\u2013344","journal-title":"Lancet"},{"issue":"3","key":"1300_CR3","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.eururo.2015.07.040","volume":"69","author":"C Turk","year":"2016","unstructured":"Turk C, Petrik A, Sarica K et al (2016) EAU guidelines on diagnosis and conservative management of urolithiasis. Eur Urol 69(3):468\u2013474","journal-title":"Eur Urol"},{"issue":"8","key":"1300_CR4","first-page":"490","volume":"99","author":"LF Fontenelle","year":"2019","unstructured":"Fontenelle LF, Sarti TD (2019) Kidney stones: treatment and prevention. Am Fam Phys 99(8):490\u2013496","journal-title":"Am Fam Phys"},{"issue":"3","key":"1300_CR5","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1017\/S1481803500012240","volume":"12","author":"ML Edmonds","year":"2010","unstructured":"Edmonds ML, Yan JW, Sedran RJ, Mcleod SL, Theakston KD (2010) The utility of renal ultrasonography in the diagnosis of renal colic in emergency department patients. CJEM 12(3):201\u2013206","journal-title":"CJEM"},{"issue":"3","key":"1300_CR6","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1097\/RUQ.0b013e3182625974","volume":"28","author":"CA Coursey","year":"2012","unstructured":"Coursey CA, Casalino DD, Remer EM et al (2012) ACR Appropriateness criteria\u00ae acute onset flank pain\u2013suspicion of stone disease. Ultrasound Q 28(3):227\u2013233","journal-title":"Ultrasound Q"},{"issue":"11","key":"1300_CR7","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1038\/nrurol.2016.154","volume":"13","author":"W Brisbane","year":"2016","unstructured":"Brisbane W, Bailey MR, Sorensen MD (2016) An overview of kidney stone imaging techniques. Nat Rev Urol 13(11):654\u2013662","journal-title":"Nat Rev Urol"},{"key":"1300_CR8","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.f2360","volume":"346","author":"JD Mathews","year":"2013","unstructured":"Mathews JD, Forsythe AV, Brady Z et al (2013) Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ 346:f2360","journal-title":"BMJ"},{"issue":"965","key":"1300_CR9","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1259\/bjr\/01948454","volume":"81","author":"EJ Hall","year":"2008","unstructured":"Hall EJ, Brenner DJ (2008) Cancer risks from diagnostic radiology. Br J Radiol 81(965):362\u2013378","journal-title":"Br J Radiol"},{"issue":"10","key":"1300_CR10","doi-asserted-by":"publisher","first-page":"e982","DOI":"10.1016\/j.ejrad.2012.06.019","volume":"81","author":"MM Rehani","year":"2012","unstructured":"Rehani MM, Ciraj-Bjelac O, Al-Naemi HM et al (2012) Radiation protection of patients in diagnostic and interventional radiology in Asian countries: impact of an IAEA project. Eur J Radiol 81(10):e982-989","journal-title":"Eur J Radiol"},{"issue":"1","key":"1300_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0969-8043(98)00021-9","volume":"50","author":"CJ Martin","year":"1999","unstructured":"Martin CJ, Sutton DG, Sharp PF (1999) Balancing patient dose and image quality. Appl Radiat Isot 50(1):1\u201319","journal-title":"Appl Radiat Isot"},{"issue":"6","key":"1300_CR12","doi-asserted-by":"publisher","first-page":"2762","DOI":"10.1016\/j.juro.2009.08.042","volume":"182","author":"FC Jellison","year":"2009","unstructured":"Jellison FC, Smith JC, Heldt JP et al (2009) Effect of low dose radiation computerized tomography protocols on distal ureteral calculus detection. J Urol 182(6):2762\u20132767","journal-title":"J Urol"},{"issue":"4","key":"1300_CR13","doi-asserted-by":"publisher","first-page":"927","DOI":"10.2214\/AJR.06.0793","volume":"188","author":"PA Poletti","year":"2007","unstructured":"Poletti PA, Platon A, Rutschmann OT, Schmidlin FR, Iselin CE, Becker CD (2007) Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic. AJR Am J Roentgenol 188(4):927\u2013933","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"1300_CR14","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s13244-014-0310-z","volume":"5","author":"PD Mclaughlin","year":"2014","unstructured":"Mclaughlin PD, Murphy KP, Hayes SA et al (2014) Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance. Insights Imaging 5(2):217\u2013230","journal-title":"Insights Imaging"},{"issue":"4","key":"1300_CR15","doi-asserted-by":"publisher","first-page":"W384","DOI":"10.2214\/AJR.14.13241","volume":"204","author":"A Padole","year":"2015","unstructured":"Padole A, Ali Khawaja RD, Kalra MK, Singh S (2015) CT radiation dose and iterative reconstruction techniques. AJR Am J Roentgenol 204(4):W384-392","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"1300_CR16","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.2214\/AJR.12.9382","volume":"199","author":"PJ Pickhardt","year":"2012","unstructured":"Pickhardt PJ, Lubner MG, Kim DH et al (2012) Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. AJR Am J Roentgenol 199(6):1266\u20131274","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"1300_CR17","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1148\/radiol.15142047","volume":"276","author":"CH Mccollough","year":"2015","unstructured":"Mccollough CH, Yu L, Kofler JM et al (2015) Degradation of CT low-contrast spatial resolution due to the use of iterative reconstruction and reduced dose levels. Radiology 276(2):499\u2013506","journal-title":"Radiology"},{"issue":"7","key":"1300_CR18","doi-asserted-by":"publisher","first-page":"2743","DOI":"10.1007\/s00330-018-5397-z","volume":"28","author":"AA Fingerle","year":"2018","unstructured":"Fingerle AA, No\u00ebl PB (2018) Dose reduction in abdominal CT: the road to submillisievert imaging. Eur Radiol 28(7):2743\u20132744","journal-title":"Eur Radiol"},{"issue":"6","key":"1300_CR19","doi-asserted-by":"publisher","first-page":"618","DOI":"10.4329\/wjr.v8.i6.618","volume":"8","author":"A Padole","year":"2016","unstructured":"Padole A, Sainani N, Lira D et al (2016) Assessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors. World J Radiol 8(6):618\u2013627","journal-title":"World J Radiol"},{"issue":"2","key":"1300_CR20","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1097\/RCT.0000000000000928","volume":"44","author":"Y Nakamura","year":"2020","unstructured":"Nakamura Y, Higaki T, Tatsugami F et al (2020) Possibility of deep learning in medical imaging focusing improvement of computed tomography image quality. J Comput Assist Tomogr 44(2):161\u2013167","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"1300_CR21","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.acra.2019.09.008","volume":"27","author":"T Higaki","year":"2020","unstructured":"Higaki T, Nakamura Y, Zhou J et al (2020) Deep learning reconstruction at CT: phantom study of the image characteristics. Acad Radiol 27(1):82\u201387","journal-title":"Acad Radiol"},{"issue":"5","key":"1300_CR22","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1007\/s00330-021-08438-z","volume":"32","author":"JA Van Stiphout","year":"2022","unstructured":"Van Stiphout JA, Driessen J, Koetzier LR et al (2022) The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis. Eur Radiol 32(5):2921\u20132929","journal-title":"Eur Radiol"},{"issue":"9","key":"1300_CR23","doi-asserted-by":"publisher","first-page":"2698","DOI":"10.1007\/s00261-020-02508-4","volume":"45","author":"K Narita","year":"2020","unstructured":"Narita K, Nakamura Y, Higaki T, Akagi M, Honda Y, Awai K (2020) Deep learning reconstruction of drip-infusion cholangiography acquired with ultra-high-resolution computed tomography. Abdom Radiol (NY) 45(9):2698\u20132704","journal-title":"Abdom Radiol (NY)"},{"issue":"6","key":"1300_CR24","doi-asserted-by":"publisher","first-page":"e180011","DOI":"10.1148\/ryai.2019180011","volume":"1","author":"Y Nakamura","year":"2019","unstructured":"Nakamura Y, Higaki T, Tatsugami F et al (2019) Deep learning\u2013based CT image reconstruction: initial evaluation targeting hypovascular hepatic metastases. Radiol Artif Intell 1(6):e180011","journal-title":"Radiol Artif Intell"},{"issue":"10","key":"1300_CR25","doi-asserted-by":"publisher","first-page":"5322","DOI":"10.1007\/s00330-019-06183-y","volume":"29","author":"F Tatsugami","year":"2019","unstructured":"Tatsugami F, Higaki T, Nakamura Y et al (2019) Deep learning-based image restoration algorithm for coronary CT angiography. Eur Radiol 29(10):5322\u20135329","journal-title":"Eur Radiol"},{"key":"1300_CR26","doi-asserted-by":"publisher","first-page":"5963","DOI":"10.1007\/s00330-022-08739-x","volume":"32","author":"G Zhang","year":"2022","unstructured":"Zhang G, Zhang X, Xu L et al (2022) Value of deep learning reconstruction at ultra-low-dose CT for evaluation of urolithiasis. Eur Radiol 32:5963","journal-title":"Eur Radiol"},{"issue":"11","key":"1300_CR27","doi-asserted-by":"publisher","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","volume":"29","author":"M Akagi","year":"2019","unstructured":"Akagi M, Nakamura Y, Higaki T et al (2019) Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT. Eur Radiol 29(11):6163\u20136171","journal-title":"Eur Radiol"},{"issue":"Suppl 1","key":"1300_CR28","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1111\/bju.15116","volume":"126","author":"MJ Roberts","year":"2020","unstructured":"Roberts MJ, Williams J, Khadra S et al (2020) A prospective, matched comparison of ultra-low and standard-dose computed tomography for assessment of renal colic. BJU Int 126(Suppl 1):27\u201332","journal-title":"BJU Int"},{"issue":"3","key":"1300_CR29","doi-asserted-by":"publisher","first-page":"553","DOI":"10.2214\/AJR.13.11350","volume":"202","author":"A Gervaise","year":"2014","unstructured":"Gervaise A, Naulet P, Beuret F et al (2014) Low-dose CT with automatic tube current modulation, adaptive statistical iterative reconstruction, and low tube voltage for the diagnosis of renal colic: impact of body mass index. AJR Am J Roentgenol 202(3):553\u2013560","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1300_CR30","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.crad.2016.10.005","volume":"72","author":"S Rob","year":"2017","unstructured":"Rob S, Bryant T, Wilson I, Somani BK (2017) Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol 72(1):11\u201315","journal-title":"Clin Radiol"},{"issue":"3","key":"1300_CR31","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.eururo.2015.07.040","volume":"69","author":"C T\u00fcrk","year":"2016","unstructured":"T\u00fcrk C, Pet\u0159\u00edk A, Sarica K et al (2016) EAU guidelines on diagnosis and conservative management of urolithiasis. Eur Urol 69(3):468\u2013474","journal-title":"Eur Urol"},{"key":"1300_CR32","doi-asserted-by":"publisher","first-page":"4700","DOI":"10.1007\/s00330-020-07566-2","volume":"31","author":"Y Nakamura","year":"2021","unstructured":"Nakamura Y, Narita K, Higaki T, Akagi M, Honda Y, Awai K (2021) Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT. Eur Radiol 31:4700\u20134709","journal-title":"Eur Radiol"},{"issue":"3","key":"1300_CR33","doi-asserted-by":"publisher","first-page":"566","DOI":"10.2214\/AJR.19.21809","volume":"214","author":"R Singh","year":"2020","unstructured":"Singh R, Digumarthy SR, Muse VV et al (2020) Image quality and lesion detection on deep learning reconstruction and iterative reconstruction of submillisievert chest and abdominal CT. AJR Am J Roentgenol 214(3):566\u2013573","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1300_CR34","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1148\/radiol.211838","volume":"303","author":"CT Jensen","year":"2022","unstructured":"Jensen CT, Gupta S, Saleh MM et al (2022) Reduced-dose deep learning reconstruction for abdominal CT of liver metastases. Radiology 303(1):90\u201398","journal-title":"Radiology"},{"issue":"2","key":"1300_CR35","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1148\/radiol.14131601","volume":"271","author":"A Lukasiewicz","year":"2014","unstructured":"Lukasiewicz A, Bhargavan-Chatfield M, Coombs L et al (2014) Radiation dose index of renal colic protocol CT studies in the United States: a report from the American college of radiology national radiology data registry. Radiology 271(2):445\u2013451","journal-title":"Radiology"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-022-01300-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-022-01300-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-022-01300-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,8]],"date-time":"2022-10-08T14:04:07Z","timestamp":1665237847000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-022-01300-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,8]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1300"],"URL":"https:\/\/doi.org\/10.1186\/s13244-022-01300-w","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,8]]},"assertion":[{"value":"10 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This prospective study received ethical approval from the Medical Ethics Committee of Beijing Union Medical College Hospital (HS-2427). Written informed consent of receiving both low-dose and ultra-low-dose abdominal CT was received from each enrolled patient.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors consent to the publication of this work.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Two authors (Min Xu and Jing Yan) are Canon Medical employees. All the other authors declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"163"}}