{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T05:43:31Z","timestamp":1786427011840,"version":"build-2736575974"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T00:00:00Z","timestamp":1670889600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T00:00:00Z","timestamp":1670889600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81901829"],"award-info":[{"award-number":["81901829"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"National High Level Hospital Clinical Research Funding","award":["2022-PUMCH-A-004"],"award-info":[{"award-number":["2022-PUMCH-A-004"]}]},{"name":"National High Level Hospital Clinical Research Funding","award":["2022-PUMCH-A-109"],"award-info":[{"award-number":["2022-PUMCH-A-109"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>To investigate the feasibility of a deep learning-accelerated T2-weighted turbo spin echo (TSE) sequence (T2<jats:sub>DL<\/jats:sub>) applied to female pelvic MRI, using standard T2-weighted TSE (T2<jats:sub>S<\/jats:sub>) as reference.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In total, 24 volunteers and 48 consecutive patients with benign uterine diseases were enrolled. Patients in the menstrual phase were excluded. T2<jats:sub>S<\/jats:sub> and T2<jats:sub>DL<\/jats:sub> sequences in three planes were performed for each participant. Quantitative image evaluation was conducted by calculating the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Image geometric distortion was evaluated by measuring the diameters in all three directions of the uterus and lesions. Qualitative image evaluation including overall image quality, artifacts, boundary sharpness of the uterine zonal layers, and lesion conspicuity were assessed by three radiologists using a 5-point Likert scale, with 5 indicating the best quality. Comparative analyses were conducted for the two sequences.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>T2<jats:sub>DL<\/jats:sub> resulted in a 62.7% timing reduction (1:54\u00a0min for T2<jats:sub>DL<\/jats:sub> and 5:06\u00a0min for T2<jats:sub>S<\/jats:sub> in axial, sagittal, and coronal imaging, respectively). Compared to T2<jats:sub>S<\/jats:sub>, T2<jats:sub>DL<\/jats:sub> had significantly higher SNR (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.001) and CNR (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.007), and without geometric distortion (<jats:italic>p<\/jats:italic>\u2009=\u20090.925\u20130.981). Inter-observer agreement regarding qualitative evaluation was excellent (Kendall\u2019s W\u2009&gt;\u20090.75). T2<jats:sub>DL<\/jats:sub> provided superior image quality (all <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), boundary sharpness of the uterine zonal layers (all <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), lesion conspicuity (<jats:italic>p<\/jats:italic>\u2009=\u20090.002, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001, and <jats:italic>p<\/jats:italic>\u2009=\u20090.021), and fewer artifacts (all <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) in sagittal, axial, and coronal imaging.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Compared with standard TSE, deep learning-accelerated T2-weighted TSE is feasible to reduce acquisition time of female pelvic MRI with significant improvement of image quality.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13244-022-01321-5","type":"journal-article","created":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T16:21:16Z","timestamp":1670948476000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Comparison of a deep learning-accelerated T2-weighted turbo spin echo sequence and its conventional counterpart for female pelvic MRI: reduced acquisition times and improved image quality"],"prefix":"10.1186","volume":"13","author":[{"given":"Jing","family":"Ren","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei-Shi","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Xia","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcel Dominik","family":"Nickel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Ye","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin-Yu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2946-4752","authenticated-orcid":false,"given":"Yong-Lan","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng-Yu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua-Dan","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,13]]},"reference":[{"key":"1321_CR1","doi-asserted-by":"publisher","first-page":"2765","DOI":"10.1007\/s00330-016-4673-z","volume":"27","author":"M Bazot","year":"2017","unstructured":"Bazot M, Bharwani N, Huchon C et al (2017) European society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis. Eur Radiol 27:2765\u20132775. https:\/\/doi.org\/10.1007\/s00330-016-4673-z","journal-title":"Eur Radiol"},{"key":"1321_CR2","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1007\/s00330-018-5515-y","volume":"29","author":"S Nougaret","year":"2019","unstructured":"Nougaret S, Horta M, Sala E et al (2019) Endometrial cancer MRI staging: Updated Guidelines of the European Society of Urogenital Radiology. Eur Radiol 29:792\u2013805. https:\/\/doi.org\/10.1007\/s00330-018-5515-y","journal-title":"Eur Radiol"},{"key":"1321_CR3","doi-asserted-by":"publisher","first-page":"2557","DOI":"10.1007\/s00261-019-01984-7","volume":"44","author":"P Balcacer","year":"2019","unstructured":"Balcacer P, Shergill A, Litkouhi B (2019) MRI of cervical cancer with a surgical perspective: staging, prognostic implications and pitfalls. Abdom Radiol (NY) 44:2557\u20132571. https:\/\/doi.org\/10.1007\/s00261-019-01984-7","journal-title":"Abdom Radiol (NY)"},{"key":"1321_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07632-9","author":"L Manganaro","year":"2021","unstructured":"Manganaro L, Lakhman Y, Bharwani N et al (2021) Staging, recurrence and follow-up of uterine cervical cancer using MRI: Updated Guidelines of the European Society of Urogenital Radiology after revised FIGO staging 2018. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-020-07632-9","journal-title":"Eur Radiol"},{"key":"1321_CR5","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1007\/s00330-010-1998-x","volume":"21","author":"C Balleyguier","year":"2011","unstructured":"Balleyguier C, Sala E, Da Cunha T et al (2011) Staging of uterine cervical cancer with MRI: guidelines of the European Society of Urogenital Radiology. Eur Radiol 21:1102\u20131110. https:\/\/doi.org\/10.1007\/s00330-010-1998-x","journal-title":"Eur Radiol"},{"key":"1321_CR6","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1007\/s13244-017-0591-0","volume":"9","author":"PV Foti","year":"2018","unstructured":"Foti PV, Farina R, Palmucci S et al (2018) Endometriosis: clinical features, MR imaging findings and pathologic correlation. Insights Imaging 9:149\u2013172. https:\/\/doi.org\/10.1007\/s13244-017-0591-0","journal-title":"Insights Imaging"},{"key":"1321_CR7","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1007\/s00261-020-02586-4","volume":"46","author":"Q Zhang","year":"2021","unstructured":"Zhang Q, Ouyang H, Ye F et al (2021) Feasibility of intravoxel incoherent motion diffusion-weighted imaging in distinguishing adenocarcinoma originated from uterine corpus or cervix. Abdom Radiol (NY) 46:732\u2013744. https:\/\/doi.org\/10.1007\/s00261-020-02586-4","journal-title":"Abdom Radiol (NY)"},{"key":"1321_CR8","doi-asserted-by":"publisher","first-page":"108779","DOI":"10.1016\/j.ejrad.2019.108779","volume":"124","author":"YF Qi","year":"2020","unstructured":"Qi YF, He YL, Lin CY et al (2020) Diffusion-weighted imaging of cervical cancer: Feasibility of ultra-high b-value at 3T. Eur J Radiol 124:108779. https:\/\/doi.org\/10.1016\/j.ejrad.2019.108779","journal-title":"Eur J Radiol"},{"key":"1321_CR9","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.carj.2016.07.007","volume":"68","author":"S Vanderby","year":"2017","unstructured":"Vanderby S, Badea A, Pe\u00f1a S\u00e1nchez JN, Kalra N, Babyn P (2017) Variations in magnetic resonance imaging provision and processes among Canadian academic centres. Can Assoc Radiol J 68:56\u201365. https:\/\/doi.org\/10.1016\/j.carj.2016.07.007","journal-title":"Can Assoc Radiol J"},{"key":"1321_CR10","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1007\/s00330-006-0470-4","volume":"17","author":"A Stadler","year":"2007","unstructured":"Stadler A, Schima W, Ba-Ssalamah A, Kettenbach J, Eisenhuber E (2007) Artifacts in body MR imaging: their appearance and how to eliminate them. Eur Radiol 17:1242\u20131255. https:\/\/doi.org\/10.1007\/s00330-006-0470-4","journal-title":"Eur Radiol"},{"key":"1321_CR11","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1148\/rg.301095076","volume":"30","author":"RK Yang","year":"2010","unstructured":"Yang RK, Roth CG, Ward RJ, deJesus JO, Mitchell DG (2010) Optimizing abdominal MR imaging: approaches to common problems. Radiographics 30:185\u2013199. https:\/\/doi.org\/10.1148\/rg.301095076","journal-title":"Radiographics"},{"key":"1321_CR12","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202\u20131210. https:\/\/doi.org\/10.1002\/mrm.10171","journal-title":"Magn Reson Med"},{"key":"1321_CR13","doi-asserted-by":"publisher","first-page":"R297","DOI":"10.1088\/0031-9155\/60\/21\/r297","volume":"60","author":"KG Hollingsworth","year":"2015","unstructured":"Hollingsworth KG (2015) Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction. Phys Med Biol 60:R297-322. https:\/\/doi.org\/10.1088\/0031-9155\/60\/21\/r297","journal-title":"Phys Med Biol"},{"key":"1321_CR14","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182\u20131195. https:\/\/doi.org\/10.1002\/mrm.21391","journal-title":"Magn Reson Med"},{"key":"1321_CR15","doi-asserted-by":"publisher","first-page":"20150487","DOI":"10.1259\/bjr.20150487","volume":"88","author":"ON Jaspan","year":"2015","unstructured":"Jaspan ON, Fleysher R, Lipton ML (2015) Compressed sensing MRI: a review of the clinical literature. Br J Radiol 88:20150487. https:\/\/doi.org\/10.1259\/bjr.20150487","journal-title":"Br J Radiol"},{"key":"1321_CR16","doi-asserted-by":"publisher","first-page":"3055","DOI":"10.1002\/mrm.26977","volume":"79","author":"K Hammernik","year":"2018","unstructured":"Hammernik K, Klatzer T, Kobler E et al (2018) Learning a variational network for reconstruction of accelerated MRI data. Magn Reson Med 79:3055\u20133071. https:\/\/doi.org\/10.1002\/mrm.26977","journal-title":"Magn Reson Med"},{"key":"1321_CR17","doi-asserted-by":"publisher","DOI":"10.3390\/cancers13143593","author":"S Gassenmaier","year":"2021","unstructured":"Gassenmaier S, Afat S, Nickel MD et al (2021) Accelerated T2-weighted TSE imaging of the prostate using deep learning image reconstruction: a prospective comparison with standard T2-weighted TSE imaging. Cancers. https:\/\/doi.org\/10.3390\/cancers13143593","journal-title":"Cancers"},{"key":"1321_CR18","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1097\/rli.0000000000000743","volume":"56","author":"J Herrmann","year":"2021","unstructured":"Herrmann J, Gassenmaier S, Nickel D et al (2021) Diagnostic confidence and feasibility of a deep learning accelerated Haste sequence of the abdomen in a single breath-hold. Invest Radiol 56:313\u2013319. https:\/\/doi.org\/10.1097\/rli.0000000000000743","journal-title":"Invest Radiol"},{"key":"1321_CR19","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.2214\/ajr.20.23313","volume":"215","author":"MP Recht","year":"2020","unstructured":"Recht MP, Zbontar J, Sodickson DK et al (2020) Using deep learning to accelerate knee MRI at 3 T: results of an interchangeability study. AJR Am J Roentgenol 215:1421\u20131429. https:\/\/doi.org\/10.2214\/ajr.20.23313","journal-title":"AJR Am J Roentgenol"},{"key":"1321_CR20","doi-asserted-by":"publisher","first-page":"109600","DOI":"10.1016\/j.ejrad.2021.109600","volume":"137","author":"S Gassenmaier","year":"2021","unstructured":"Gassenmaier S, Afat S, Nickel D, Mostapha M, Herrmann J, Othman AE (2021) Deep learning-accelerated T2-weighted imaging of the prostate: reduction of acquisition time and improvement of image quality. Eur J Radiol 137:109600. https:\/\/doi.org\/10.1016\/j.ejrad.2021.109600","journal-title":"Eur J Radiol"},{"key":"1321_CR21","doi-asserted-by":"publisher","first-page":"81.e19","DOI":"10.1016\/j.crad.2018.09.008","volume":"74","author":"YL He","year":"2019","unstructured":"He YL, Ding N, Qi YF et al (2019) Visualising the boundary sharpness of uterine zonal structures using high-resolution T2-weighted images during the menstrual cycle. Clin Radiol 74:81.e19-81.e24. https:\/\/doi.org\/10.1016\/j.crad.2018.09.008","journal-title":"Clin Radiol"},{"key":"1321_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.placenta.2019.01.017","volume":"77","author":"AA Badachhape","year":"2019","unstructured":"Badachhape AA, Kumar A, Ghaghada KB et al (2019) Pre-clinical magnetic resonance imaging of retroplacental clear space throughout gestation. Placenta 77:1\u20137. https:\/\/doi.org\/10.1016\/j.placenta.2019.01.017","journal-title":"Placenta"},{"key":"1321_CR23","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.ejro.2018.12.003","volume":"6","author":"J Hossein","year":"2019","unstructured":"Hossein J, Fariborz F, Mehrnaz R, Babak R (2019) Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging. Eur J Radiol Open 6:36\u201341. https:\/\/doi.org\/10.1016\/j.ejro.2018.12.003","journal-title":"Eur J Radiol Open"},{"key":"1321_CR24","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1097\/rli.0000000000000785","volume":"56","author":"J Herrmann","year":"2021","unstructured":"Herrmann J, Nickel D, Mugler JP et al (2021) Development and evaluation of deep learning-accelerated single-breath-hold abdominal Haste at 3 T using variable refocusing flip angles. Invest Radiol 56:645\u2013652. https:\/\/doi.org\/10.1097\/rli.0000000000000785","journal-title":"Invest Radiol"},{"key":"1321_CR25","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1002\/jmri.20969","volume":"26","author":"O Dietrich","year":"2007","unstructured":"Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375\u2013385. https:\/\/doi.org\/10.1002\/jmri.20969","journal-title":"J Magn Reson Imaging"},{"key":"1321_CR26","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1148\/radiol.2453062151","volume":"245","author":"JT Heverhagen","year":"2007","unstructured":"Heverhagen JT (2007) Noise measurement and estimation in MR imaging experiments. Radiology 245:638\u2013639. https:\/\/doi.org\/10.1148\/radiol.2453062151","journal-title":"Radiology"},{"key":"1321_CR27","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1002\/jmri.20996","volume":"26","author":"KR Zand","year":"2007","unstructured":"Zand KR, Reinhold C, Haider MA, Nakai A, Rohoman L, Maheshwari S (2007) Artifacts and pitfalls in MR imaging of the pelvis. J Magn Reson Imaging 26:480\u2013497. https:\/\/doi.org\/10.1002\/jmri.20996","journal-title":"J Magn Reson Imaging"},{"key":"1321_CR28","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1002\/jmri.24850","volume":"42","author":"M Zaitsev","year":"2015","unstructured":"Zaitsev M, Maclaren J, Herbst M (2015) Motion artifacts in MRI: a complex problem with many partial solutions. J Magn Reson Imaging 42:887\u2013901. https:\/\/doi.org\/10.1002\/jmri.24850","journal-title":"J Magn Reson Imaging"},{"key":"1321_CR29","doi-asserted-by":"publisher","first-page":"3245","DOI":"10.1007\/s00330-020-06686-z","volume":"30","author":"T Tsuboyama","year":"2020","unstructured":"Tsuboyama T, Takei O, Okada A, Honda T, Kuriyama K (2020) Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis. Eur Radiol 30:3245\u20133253. https:\/\/doi.org\/10.1007\/s00330-020-06686-z","journal-title":"Eur Radiol"},{"key":"1321_CR30","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1093\/humupd\/dmz049","volume":"26","author":"C Chapron","year":"2020","unstructured":"Chapron C, Vannuccini S, Santulli P et al (2020) Diagnosing adenomyosis: an integrated clinical and imaging approach. Hum Reprod Update 26:392\u2013411. https:\/\/doi.org\/10.1093\/humupd\/dmz049","journal-title":"Hum Reprod Update"},{"key":"1321_CR31","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/s11912-017-0640-3","volume":"19","author":"SR Khan","year":"2017","unstructured":"Khan SR, Arshad M, Wallitt K, Stewart V, Bharwani N, Barwick TD (2017) What\u2019s new in imaging for gynecologic cancer? Curr Oncol Rep 19:85. https:\/\/doi.org\/10.1007\/s11912-017-0640-3","journal-title":"Curr Oncol Rep"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-022-01321-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-022-01321-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-022-01321-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T16:22:08Z","timestamp":1670948528000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-022-01321-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,13]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1321"],"URL":"https:\/\/doi.org\/10.1186\/s13244-022-01321-5","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,13]]},"assertion":[{"value":"16 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This prospective study was approved by our institutional review board and complied with ethical committee standards. Written informed consent was obtained from participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Co-author Jin-Xia Zhu and Xiao-Ye Wang are employees of Siemens Healthineers Ltd., Beijing, China and Marcel Dominik Nickel is an employee of Siemens Healthcare GmbH, Erlangen, Germany. The other authors have no conflicts of interest to disclose. The authors not employed by Siemens were in control of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"193"}}