{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T05:54:27Z","timestamp":1793944467348,"version":"4.8.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,19]],"date-time":"2023-06-19T00:00:00Z","timestamp":1687132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,19]],"date-time":"2023-06-19T00:00:00Z","timestamp":1687132800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Dynamic chest radiography (DCR) is a real-time sequential high-resolution digital X-ray imaging system of the thorax in motion over the respiratory cycle, utilising pulsed image exposure and a larger field of view than fluoroscopy coupled with a low radiation dose, where post-acquisition image processing by computer algorithm automatically characterises the motion of thoracic structures. We conducted a systematic review of the literature and found 29 relevant publications describing its use in humans including the assessment of diaphragm and chest wall motion, measurement of pulmonary ventilation and perfusion, and the assessment of airway narrowing. Work is ongoing in several other areas including assessment of diaphragmatic paralysis. We assess the findings, methodology and limitations of DCR, and we discuss the current and future roles of this promising medical imaging technology.<\/jats:p>\n                  <jats:p>\n                    <jats:bold>Critical relevance statement<\/jats:bold>\n                    Dynamic chest radiography provides a wealth of clinical information, but further research is required to identify its clinical niche.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Graphical abstract<\/jats:bold>\n                  <\/jats:p>","DOI":"10.1186\/s13244-023-01451-4","type":"journal-article","created":{"date-parts":[[2023,6,18]],"date-time":"2023-06-18T20:02:03Z","timestamp":1687118523000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["Dynamic chest radiography: a state-of-the-art review"],"prefix":"10.1186","volume":"14","author":[{"given":"Fred","family":"Fyles","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9334-486X","authenticated-orcid":false,"given":"Thomas S.","family":"FitzMaurice","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan E.","family":"Robinson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ram","family":"Bedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Burhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin J.","family":"Walshaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,19]]},"reference":[{"issue":"5","key":"1451_CR1","doi-asserted-by":"publisher","first-page":"665","DOI":"10.6009\/jjrt.KJ00001364425","volume":"58","author":"R Tanaka","year":"2002","unstructured":"Tanaka R, Sanada S, Suzuki M, Matsui T, Uoyama Y (2002) New method of screening chest radiography with computer analysis of respiratory kinetics. Nihon Hoshasen Gijutsu Gakkai Zasshi 58(5):665\u2013669","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"9","key":"1451_CR2","first-page":"579","volume":"63","author":"S Sanada","year":"2003","unstructured":"Sanada S, Tanaka R, Kobayashi T, Suzuki M, Inoue H (2003) Screening chest X-ray examination with kinetic analysis using flat-panel detector. Nippon Igaku Hoshasen Gakkai Zasshi 63(9):579\u2013581","journal-title":"Nippon Igaku Hoshasen Gakkai Zasshi"},{"issue":"8","key":"1451_CR3","doi-asserted-by":"publisher","first-page":"984","DOI":"10.6009\/jjrt.KJ00000921844","volume":"59","author":"R Tanaka","year":"2003","unstructured":"Tanaka R, Sanada S, Kobayashi T, Suzuki M, Matsui T, Inoue H (2003) Development of breathing chest radiography: study of exposure timing. Nihon Hoshasen Gijutsu Gakkai Zasshi 59(8):984\u2013992","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"1","key":"1451_CR4","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1007\/s10278-004-1045-z","volume":"19","author":"R Tanaka","year":"2006","unstructured":"Tanaka R, Sanada S, Kobayashi T, Suzuki M, Matsui T, Matsui O (2006) Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system. J Digit Imaging 19(1):41\u201351","journal-title":"J Digit Imaging"},{"issue":"5","key":"1451_CR5","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1007\/s11548-009-0364-4","volume":"4","author":"R Tanaka","year":"2009","unstructured":"Tanaka R, Sanada S, Fujimura M et al (2009) Pulmonary blood flow evaluation using a dynamic flat-panel detector: feasibility study with pulmonary diseases. Int J Comput Assist Radiol Surg 4(5):449\u2013455","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"1451_CR6","first-page":"475","volume":"57","author":"C Weissman","year":"1984","unstructured":"Weissman C, Askanazi J, Milic-Emili J, Kinney JM (1984) Effect of respiratory apparatus on respiration. J Appl Physiol Respir Environ Exerc Physiol 57(2):475\u2013480","journal-title":"J Appl Physiol Respir Environ Exerc Physiol"},{"issue":"1","key":"1451_CR7","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1183\/09031936.97.10010161","volume":"10","author":"JN Han","year":"1997","unstructured":"Han JN, Stegen K, Cauberghs M, Van de Woestijne KP (1997) Influence of awareness of the recording of breathing on respiratory pattern in healthy humans. Eur Respir J 10(1):161\u2013166","journal-title":"Eur Respir J"},{"issue":"10","key":"1451_CR8","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1097\/01.rli.0000236904.79265.68","volume":"41","author":"R Tanaka","year":"2006","unstructured":"Tanaka R, Sanada S, Okazaki N et al (2006) Evaluation of pulmonary function using breathing chest radiography with a dynamic flat panel detector: primary results in pulmonary diseases. Invest Radiol 41(10):735\u2013745","journal-title":"Invest Radiol"},{"issue":"1","key":"1451_CR9","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s10278-007-9017-8","volume":"21","author":"R Tanaka","year":"2008","unstructured":"Tanaka R, Sanada S, Okazaki N et al (2008) Detectability of regional lung ventilation with flat-panel detector-based dynamic radiography. J Digit Imaging 21(1):109\u2013120","journal-title":"J Digit Imaging"},{"issue":"2","key":"1451_CR10","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1007\/s12194-008-0020-7","volume":"1","author":"R Tanaka","year":"2008","unstructured":"Tanaka R, Sanada S, Fujimura M et al (2008) Development of functional chest imaging with a dynamic flat-panel detector (FPD). Radiol Phys Technol 1(2):137\u2013143","journal-title":"Radiol Phys Technol"},{"issue":"6","key":"1451_CR11","doi-asserted-by":"publisher","first-page":"738","DOI":"10.6009\/jjrt.65.738","volume":"65","author":"H Kawashima","year":"2009","unstructured":"Kawashima H, Tanaka R, Sanada S (2009) Reproducibility of dynamic chest radiography with a flat-panel detector-respiratory changes in pixel value. Nihon Hoshasen Gijutsu Gakkai Zasshi 65(6):738\u2013744","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"1","key":"1451_CR12","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1007\/s12194-009-0074-1","volume":"3","author":"R Tanaka","year":"2010","unstructured":"Tanaka R, Sanada S, Fujimura M et al (2010) Development of pulmonary blood flow evaluation method with a dynamic flat-panel detector: quantitative correlation analysis with findings on perfusion scan. Radiol Phys Technol 3(1):40\u201345","journal-title":"Radiol Phys Technol"},{"issue":"2","key":"1451_CR13","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1007\/s10278-008-9116-1","volume":"22","author":"Y Tsuchiya","year":"2009","unstructured":"Tsuchiya Y, Kodera Y, Tanaka R, Sanada S (2009) Quantitative kinetic analysis of lung nodules using the temporal subtraction technique in dynamic chest radiographies performed with a flat panel detector. J Digit Imaging 22(2):126\u2013135","journal-title":"J Digit Imaging"},{"issue":"1","key":"1451_CR14","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s11548-010-0491-y","volume":"6","author":"R Tanaka","year":"2011","unstructured":"Tanaka R, Sanada S, Fujimura M et al (2011) Ventilatory impairment detection based on distribution of respiratory-induced changes in pixel values in dynamic chest radiography: a feasibility study. Int J Comput Assist Radiol Surg 6(1):103\u2013110","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"1451_CR15","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.2.2.024002","volume":"2","author":"R Tanaka","year":"2015","unstructured":"Tanaka R, Sanada S, Sakuta K, Kawashima H (2015) Quantitative analysis of rib kinematics based on dynamic chest bone images: preliminary results. J Med Imaging (Bellingham) 2(2):024002","journal-title":"J Med Imaging (Bellingham)"},{"issue":"4","key":"1451_CR16","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.acra.2016.11.014","volume":"24","author":"Y Yamada","year":"2017","unstructured":"Yamada Y, Ueyama M, Abe T et al (2017) Time-resolved quantitative analysis of the diaphragms during tidal breathing in a standing position using dynamic chest radiography with a flat panel detector system (\u201cdynamic X-ray phrenicography\u201d): initial experience in 172 volunteers. Acad Radiol 24(4):393\u2013400","journal-title":"Acad Radiol"},{"key":"1451_CR17","doi-asserted-by":"crossref","unstructured":"Tanaka R, Matsuda H, Sanada S (2017) Time-series analysis of lung texture on bone-suppressed dynamic chest radiograph for the evaluation of pulmonary function: a preliminary study: SPIE","DOI":"10.1117\/12.2254377"},{"key":"1451_CR18","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.ejrad.2016.12.014","volume":"87","author":"Y Yamada","year":"2017","unstructured":"Yamada Y, Ueyama M, Abe T et al (2017) Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system (\u201cdynamic X-ray phrenicography\u201d). Eur J Radiol 87:76\u201382","journal-title":"Eur J Radiol"},{"key":"1451_CR19","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ejrad.2017.04.016","volume":"92","author":"Y Yamada","year":"2017","unstructured":"Yamada Y, Ueyama M, Abe T et al (2017) Difference in the craniocaudal gradient of the maximum pixel value change rate between chronic obstructive pulmonary disease patients and normal subjects using sub-mGy dynamic chest radiography with a flat panel detector system. Eur J Radiol 92:37\u201344","journal-title":"Eur J Radiol"},{"key":"1451_CR20","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.ejrad.2019.01.034","volume":"113","author":"T Hida","year":"2019","unstructured":"Hida T, Yamada Y, Ueyama M et al (2019) Time-resolved quantitative evaluation of diaphragmatic motion during forced breathing in a health screening cohort in a standing position: dynamic chest phrenicography. Eur J Radiol 113:59\u201365","journal-title":"Eur J Radiol"},{"key":"1451_CR21","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ejrad.2018.12.023","volume":"112","author":"T Hida","year":"2019","unstructured":"Hida T, Yamada Y, Ueyama M et al (2019) Decreased and slower diaphragmatic motion during forced breathing in severe COPD patients: time-resolved quantitative analysis using dynamic chest radiography with a flat panel detector system. Eur J Radiol 112:28\u201336","journal-title":"Eur J Radiol"},{"key":"1451_CR22","doi-asserted-by":"crossref","unstructured":"Kitahara Y, Tanaka R, Roth HR, Oda H, Mori K, Kasahara K et al (eds) (2019) Lung segmentation based on a deep learning approach for dynamic chest radiography. Medical Imaging 2019: Computer-Aided Diagnosis; 01 Mar 2019","DOI":"10.1117\/12.2512711"},{"issue":"1","key":"1451_CR23","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s12957-021-02158-w","volume":"19","author":"J Hanaoka","year":"2021","unstructured":"Hanaoka J, Yoden M, Hayashi K et al (2021) Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection. World J Surg Oncol 19(1):43","journal-title":"World J Surg Oncol"},{"key":"1451_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2020.100263","volume":"7","author":"T Hino","year":"2020","unstructured":"Hino T, Hata A, Hida T et al (2020) Projected lung areas using dynamic X-ray (DXR). Eur J Radiol Open 7:100263","journal-title":"Eur J Radiol Open"},{"issue":"5","key":"1451_CR25","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1159\/000506881","volume":"99","author":"N Ohkura","year":"2020","unstructured":"Ohkura N, Kasahara K, Watanabe S et al (2020) Dynamic-ventilatory digital radiography in air flow limitation: a change in lung area reflects air trapping. Respiration 99(5):382\u2013388","journal-title":"Respiration"},{"issue":"10","key":"1451_CR26","doi-asserted-by":"publisher","first-page":"4800","DOI":"10.1002\/mp.14407","volume":"47","author":"R Tanaka","year":"2020","unstructured":"Tanaka R, Matsumoto I, Tamura M et al (2020) Comparison of dynamic flat-panel detector-based chest radiography with nuclear medicine ventilation\u2013perfusion imaging for the evaluation of pulmonary function: a clinical validation study. Med Phys 47(10):4800\u20134809","journal-title":"Med Phys"},{"key":"1451_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.109141","volume":"129","author":"S Watase","year":"2020","unstructured":"Watase S, Sonoda A, Matsutani N et al (2020) Evaluation of intrathoracic tracheal narrowing in patients with obstructive ventilatory impairment using dynamic chest radiography: a preliminary study. Eur J Radiol 129:109141","journal-title":"Eur J Radiol"},{"issue":"11","key":"1451_CR28","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1002\/acm2.13071","volume":"21","author":"S Yamamoto","year":"2020","unstructured":"Yamamoto S, Hasebe T, Tomita K et al (2020) Pulmonary perfusion by chest digital dynamic radiography: comparison between breath-holding and deep-breathing acquisition. J Appl Clin Med Phys 21(11):247\u2013255","journal-title":"J Appl Clin Med Phys"},{"key":"1451_CR29","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.jcf.2022.01.007","volume":"21","author":"TS FitzMaurice","year":"2022","unstructured":"FitzMaurice TS, McCann C, Nazareth D, Shaw M, McNamara PS, Walshaw MJ (2022) Measuring the effect of elexacaftor\/tezacaftor\/ivacaftor combination therapy on the respiratory pump in people with CF using dynamic chest radiography. J Cyst Fibros 21:1036\u20131041","journal-title":"J Cyst Fibros"},{"issue":"1","key":"1451_CR30","doi-asserted-by":"publisher","first-page":"00343","DOI":"10.1183\/23120541.00343-2021","volume":"8","author":"TS FitzMaurice","year":"2022","unstructured":"FitzMaurice TS, McCann C, Nazareth DS, Walshaw MJ (2022) Characterisation of hemidiaphragm dysfunction using dynamic chest radiography: a pilot study. ERJ Open Res 8(1):00343\u201302021","journal-title":"ERJ Open Res"},{"key":"1451_CR31","doi-asserted-by":"publisher","first-page":"1393","DOI":"10.2147\/COPD.S309960","volume":"16","author":"N Ohkura","year":"2021","unstructured":"Ohkura N, Tanaka R, Watanabe S et al (2021) Chest dynamic-ventilatory digital radiography in chronic obstructive or restrictive lung disease. Int J Chron Obstruct Pulmon Dis 16:1393\u20131399","journal-title":"Int J Chron Obstruct Pulmon Dis"},{"issue":"9","key":"1451_CR32","doi-asserted-by":"publisher","first-page":"4016","DOI":"10.21037\/qims-20-1217","volume":"11","author":"R Tanaka","year":"2021","unstructured":"Tanaka R, Matsumoto I, Tamura M et al (2021) Dynamic chest radiography: clinical validation of ventilation and perfusion metrics derived from changes in radiographic lung density compared to nuclear medicine imaging. Quant Imaging Med Surg 11(9):4016\u20134027","journal-title":"Quant Imaging Med Surg"},{"key":"1451_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109866","volume":"142","author":"M Ueyama","year":"2021","unstructured":"Ueyama M, Hashimoto S, Takeda A et al (2021) Prediction of forced vital capacity with dynamic chest radiography in interstitial lung disease. Eur J Radiol 142:109866","journal-title":"Eur J Radiol"},{"key":"1451_CR34","doi-asserted-by":"crossref","unstructured":"FitzMaurice TS, McCann C, Nazareth DS, McNamara PS, Walshaw MJ (2022) Use of dynamic chest radiography to assess treatment of pulmonary exacerbations in cystic fibrosis. Radiology 212641","DOI":"10.1148\/radiol.212641"},{"key":"1451_CR35","unstructured":"Hart D, Hillier MC, Shrimpton PC (2012) Doses to patients from radiographic and fluoroscopic X-ray imaging procedures in the UK: 2010 review (HPA-CRCE-034)"},{"issue":"5","key":"1451_CR36","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.crad.2020.12.003","volume":"76","author":"F Moloney","year":"2021","unstructured":"Moloney F, Kavanagh RG, Ronan NJ et al (2021) Ultra-low-dose thoracic CT with model-based iterative reconstruction (MBIR) in cystic fibrosis patients undergoing treatment with cystic fibrosis transmembrane conductance regulators (CFTR). Clin Radiol 76(5):393","journal-title":"Clin Radiol"},{"key":"1451_CR37","unstructured":"Wall BF, Haylock R, Jansen JTM, Hillier MC, Hart D, Shrimpton PC (2011) Radiation risks from medical X-ray examinations as a function of the age and sex of the patient (HPA-CRCE-028)"},{"issue":"1","key":"1451_CR38","doi-asserted-by":"publisher","first-page":"00714","DOI":"10.1183\/23120541.00714-2020","volume":"7","author":"A Boussuges","year":"2021","unstructured":"Boussuges A, Finance J, Chaumet G, Br\u00e9geon F (2021) Diaphragmatic motion recorded by M-mode ultrasonography: limits of normality. ERJ Open Res 7(1):00714\u201302020","journal-title":"ERJ Open Res"},{"key":"1451_CR39","doi-asserted-by":"crossref","unstructured":"Fitzmaurice T (2021) A study comparing ultrasound versus X-rays to diagnose paralysed diaphragm muscles ISRCTN Registry: ISRCTN Registry. Available from: https:\/\/www.isrctn.com\/ISRCTN31111675","DOI":"10.1186\/ISRCTN31111675"},{"key":"1451_CR40","first-page":"1","volume":"10","author":"S Motamedi-Fakhr","year":"2016","unstructured":"Motamedi-Fakhr S, Wilson RC, Iles R (2016) Tidal breathing patterns derived from structured light plethysmography in COPD patients compared with healthy subjects. Med Devices (Auckl) 10:1\u20139","journal-title":"Med Devices (Auckl)"},{"issue":"3","key":"1451_CR41","first-page":"548","volume":"96","author":"PC Pratt","year":"1967","unstructured":"Pratt PC, Klugh GA (1967) A method for the determination of total lung capacity from posteroanterior and lateral chest roentgenograms. Am Rev Respir Dis 96(3):548\u2013552","journal-title":"Am Rev Respir Dis"},{"issue":"1","key":"1451_CR42","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s12194-007-0003-0","volume":"1","author":"R Tanaka","year":"2008","unstructured":"Tanaka R, Sanada S, Tsujioka K, Matsui T, Takata T, Matsui O (2008) Development of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom. Radiol Phys Technol 1(1):27\u201332","journal-title":"Radiol Phys Technol"},{"issue":"4","key":"1451_CR43","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1253\/circj.CJ-20-1259","volume":"85","author":"H Miyatake","year":"2021","unstructured":"Miyatake H, Asada K, Tabata T, Eguchi Y, Matsutani N, Nakagawa Y (2021) Novel pulmonary circulation imaging using dynamic chest radiography for acute pulmonary embolism. Circ J 85(4):400","journal-title":"Circ J"},{"key":"1451_CR44","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-021-02517-4","author":"S Hoshino","year":"2021","unstructured":"Hoshino S, Miyatake H, Maruo Y (2021) Using dynamic digital radiography to assess pulmonary circulation imaging in a patient with congenital heart disease. Int J Cardiovasc Imaging. https:\/\/doi.org\/10.1007\/s10554-021-02517-4","journal-title":"Int J Cardiovasc Imaging"},{"issue":"6","key":"1451_CR45","doi-asserted-by":"publisher","first-page":"e264","DOI":"10.1093\/ehjci\/jeac027","volume":"23","author":"Y Yamasaki","year":"2022","unstructured":"Yamasaki Y, Moriyama S, Tatsumoto R, Abe K, Ishigami K (2022) Chronic thromboembolic pulmonary hypertension after acute pulmonary thromboembolism revealed by dynamic chest radiography. Eur Heart J Cardiovasc Imaging 23(6):e264\u2013e265","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"2","key":"1451_CR46","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1148\/radiol.2021204631","volume":"300","author":"Y Yamasaki","year":"2021","unstructured":"Yamasaki Y, Ishigami K (2021) Dynamic chest radiography of pulmonary arteriovenous malformation. Radiology 300(2):285","journal-title":"Radiology"},{"issue":"12","key":"1451_CR47","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.crad.2013.06.017","volume":"68","author":"P Leong","year":"2013","unstructured":"Leong P, Bardin PG, Lau KK (2013) What\u2019s in a name? Expiratory tracheal narrowing in adults explained. Clin Radiol 68(12):1268\u20131275","journal-title":"Clin Radiol"},{"issue":"3","key":"1451_CR48","doi-asserted-by":"publisher","first-page":"00055","DOI":"10.1183\/23120541.00055-2021","volume":"7","author":"A Mitropoulos","year":"2021","unstructured":"Mitropoulos A, Song W-J, Almaghlouth F, Kemp S, Polkey M, Hull JH (2021) Detection and diagnosis of large airway collapse: a systematic review. ERJ Open Res 7(3):00055\u201302021","journal-title":"ERJ Open Res"},{"issue":"1","key":"1451_CR49","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2021","unstructured":"Rajendran K, Petersilka M, Henning A et al (2021) First clinical photon-counting detector CT system: technical evaluation. Radiology 303(1):130\u2013138","journal-title":"Radiology"},{"issue":"6","key":"1451_CR50","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.2214\/AJR.14.13629","volume":"204","author":"Y Kim","year":"2015","unstructured":"Kim Y, Kim YK, Lee BE et al (2015) Ultra-low-dose CT of the thorax using iterative reconstruction: evaluation of image quality and radiation dose reduction. AJR Am J Roentgenol 204(6):1197\u20131202","journal-title":"AJR Am J Roentgenol"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01451-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-023-01451-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01451-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,18]],"date-time":"2023-06-18T21:02:19Z","timestamp":1687122139000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-023-01451-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,19]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1451"],"URL":"https:\/\/doi.org\/10.1186\/s13244-023-01451-4","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,19]]},"assertion":[{"value":"15 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Competing interests: MJW, TSF and FF report support for educational conference travel from Konica Minolta, Inc. RB reports personal fees from Konica Minolta Inc., outside the submitted work. TSF reports honoraria for the presentation of educational material from Konica Minolta Healthcare, Inc., outside the submitted work. None of the other authors declare any competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"107"}}