{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T07:18:17Z","timestamp":1794035897577,"version":"4.8.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T00:00:00Z","timestamp":1695427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T00:00:00Z","timestamp":1695427200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Young Scholars Fostering Fund of the First Affiliated Hospital of Nanjing Medical University","award":["PY2021002"],"award-info":[{"award-number":["PY2021002"]}]},{"DOI":"10.13039\/501100012166","name":"National key research and development program","doi-asserted-by":"crossref","award":["2022YFC2401604"],"award-info":[{"award-number":["2022YFC2401604"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>It is critical to early monitor and manage small-for-gestational age (SGA) infants with truly adverse outcomes not detected by conventional methods. We aimed to explore the value of diffusion-weighted imaging (DWI)-based virtual magnetic resonance elastography (vMRE) and intravoxel incoherent motion (IVIM)-based biexponential and stretched exponential parameters in predicting adverse outcomes of SGA infants.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Twenty SGA infants with adverse outcomes and forty without adverse outcomes were included in this prospective study. One DWI-based vMRE parameter [the stiffness value (<jats:italic>\u03bc<\/jats:italic><jats:sub>diff<\/jats:sub>)], five IVIM\u2013based parameters [true diffusion coefficient (<jats:italic>D<\/jats:italic>), pseudo-diffusion coefficient (<jats:italic>D<\/jats:italic><jats:sup><jats:italic>*<\/jats:italic><\/jats:sup>), perfusion fraction (<jats:italic>f<\/jats:italic>), diffusion distribution coefficient (<jats:italic>DDC<\/jats:italic>), and diffusion heterogeneity index (<jats:italic>Alpha<\/jats:italic>)] and apparent diffusion coefficient (<jats:italic>ADC<\/jats:italic>) were calculated and compared between groups. The predictive efficiency was compared by the logistic regression analysis and receiver operating characteristic curve analysis. The relationship between the <jats:italic>\u03bc<\/jats:italic><jats:sub>diff<\/jats:sub> value with gestational age was also evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The placental <jats:italic>\u03bc<\/jats:italic><jats:sub>diff<\/jats:sub> value was remarkably higher, and the <jats:italic>f<\/jats:italic>, <jats:italic>DDC<\/jats:italic>, and <jats:italic>ADC<\/jats:italic> values were considerably lower in the SGA infants with adverse outcomes compared with those without adverse outcomes. The <jats:italic>\u03bc<\/jats:italic><jats:sub>diff<\/jats:sub> and <jats:italic>f<\/jats:italic> value were predictive risk factors for SGA infants with adverse outcomes. A combined predictive model (<jats:italic>\u03bc<\/jats:italic><jats:sub>diff<\/jats:sub> and<jats:italic> f<\/jats:italic>) improved the predictive efficacy. Moreover, there was no statistically significant correlation between the placental stiffness value and gestational age.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Functional MRI parameters to quantify placenta elastography and microcirculation in SGA patients. This might be a useful tool to assess placental function and a vital non-invasive supplement for predicting adverse outcomes of SGA infants.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Critical relevance statement<\/jats:title>\n                <jats:p>This prospective study shows DWI-based virtual magnetic resonance elastography and intravoxel incoherent motion-based functional parameters to quantify placenta elastography and microcirculation in small-for-gestational-age patients, which could complement existing non-invasive methods for monitoring and predicting neonatal perinatal adverse outcome.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Key points<\/jats:title>\n                <jats:p>\u2022 vMRE is an emerging non-invasive imaging technique for evaluating placenta stiffness.<\/jats:p>\n                <jats:p>\u2022 SGA infants with adverse outcome have stiffer placental elasticity and lower microcirculation.<\/jats:p>\n                <jats:p>\u2022 Risk factors combination displayed better efficacy in predicting adverse outcomes of SGA.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Graphical Abstract<\/jats:title>\n                \n              <\/jats:sec>","DOI":"10.1186\/s13244-023-01503-9","type":"journal-article","created":{"date-parts":[[2023,9,25]],"date-time":"2023-09-25T08:30:14Z","timestamp":1695630614000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Value of placental virtual magnetic resonance elastography and intravoxel incoherent motion-based diffusion and perfusion in predicting adverse outcomes of small-for-gestational-age infants"],"prefix":"10.1186","volume":"14","author":[{"given":"Jing","family":"Deng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuwei","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yao","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiacheng","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aining","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xihu","family":"Mu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feifei","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feiyun","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,23]]},"reference":[{"key":"1503_CR1","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1002\/uog.22134","volume":"56","author":"CC Lees","year":"2020","unstructured":"Lees CC, Stampalija T, Baschat A et al (2020) ISUOG Practice Guidelines: diagnosis and management of small-for-gestational-age fetus and fetal growth restriction. Ultrasound Obstet Gynecol 56:298\u2013312","journal-title":"Ultrasound Obstet Gynecol"},{"key":"1503_CR2","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1148\/rg.2017160155","volume":"37","author":"S Fadl","year":"2017","unstructured":"Fadl S, Moshiri M, Fligner CL, Katz DS, Dighe M (2017) Placental imaging: normal appearance with review of pathologic findings. Radiographics 37:979\u2013998","journal-title":"Radiographics"},{"key":"1503_CR3","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.ajog.2021.11.1357","volume":"226","author":"CC Lees","year":"2022","unstructured":"Lees CC, Romero R, Stampalija T et al (2022) Clinical Opinion: The diagnosis and management of suspected fetal growth restriction: an evidence-based approach. Am J Obstet Gynecol 226:366\u2013378","journal-title":"Am J Obstet Gynecol"},{"key":"1503_CR4","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.neuroimage.2017.12.062","volume":"187","author":"D Le Bihan","year":"2019","unstructured":"Le Bihan D (2019) What can we see with IVIM MRI? Neuroimage 187:56\u201367","journal-title":"Neuroimage"},{"key":"1503_CR5","doi-asserted-by":"crossref","unstructured":"Federau C (2017) Intravoxel incoherent motion MRI as a means to measure in vivo perfusion: a review of the evidence.\u00a0NMR Biomed\u00a030:e3870","DOI":"10.1002\/nbm.3780"},{"key":"1503_CR6","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.placenta.2019.08.078","volume":"88","author":"T Chen","year":"2019","unstructured":"Chen T, Zhao M, Song J et al (2019) The effect of maternal hyperoxygenation on placental perfusion in normal and fetal growth restricted pregnancies using intravoxel incoherent motion. Placenta 88:28\u201335","journal-title":"Placenta"},{"key":"1503_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.placenta.2022.01.005","volume":"119","author":"M Malmberg","year":"2022","unstructured":"Malmberg M, Kragsterman E, Sinding M et al (2022) Perfusion fraction derived from IVIM analysis of diffusion-weighted MRI in the assessment of placental vascular malperfusion antenatally. Placenta 119:1\u20137","journal-title":"Placenta"},{"key":"1503_CR8","doi-asserted-by":"publisher","first-page":"5222","DOI":"10.1007\/s00330-023-09496-1","volume":"33","author":"Q Li","year":"2023","unstructured":"Li Q, Zhang T, Che F et al (2023) Intravoxel incoherent motion diffusion weighted imaging for preoperative evaluation of liver regeneration after hepatectomy in hepatocellular carcinoma. Eur Radiol 33:5222\u20135235","journal-title":"Eur Radiol"},{"key":"1503_CR9","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.ultrasmedbio.2016.08.037","volume":"43","author":"G Durhan","year":"2017","unstructured":"Durhan G, \u00dcnverdi H, Deveci C et al (2017) Placental elasticity and histopathological findings in normal and intra-uterine growth restriction pregnancies assessed with strain elastography in ex vivo placenta. Ultrasound Med Biol 43:111\u2013118","journal-title":"Ultrasound Med Biol"},{"key":"1503_CR10","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.ejrad.2017.10.007","volume":"97","author":"HH Arioz","year":"2017","unstructured":"Arioz HH, Alici DE, Kandemirli SG et al (2017) In vivo assessment of placental elasticity in intrauterine growth restriction by shear-wave elastography. Eur J Radiol 97:16\u201320","journal-title":"Eur J Radiol"},{"key":"1503_CR11","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1111\/1471-0528.13148","volume":"122","author":"I Monier","year":"2015","unstructured":"Monier I, Blondel B, Ego A, Kaminiski M, Goffinet F, Zeitlin J (2015) Poor effectiveness of antenatal detection of fetal growth restriction and consequences for obstetric management and neonatal outcomes: a French national study. BJOG 122:518\u2013527","journal-title":"BJOG"},{"key":"1503_CR12","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1148\/radiol.2017170025","volume":"285","author":"D Le Bihan","year":"2017","unstructured":"Le Bihan D, Ichikawa S, Motosugi U (2017) Diffusion and intravoxel incoherent motion MR imaging-based virtual elastography: a hypothesis-generating study in the liver. Radiology 285:609\u2013619","journal-title":"Radiology"},{"key":"1503_CR13","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00261-020-02595-3","volume":"46","author":"AN Abu","year":"2021","unstructured":"Abu AN, Dillman JR, Gandhi DB, Dudley JA, Trout AT, Miethke AG (2021) Association between liver diffusion-weighted imaging apparent diffusion coefficient values and other measures of liver disease in pediatric autoimmune liver disease patients. Abdom Radiol (NY) 46:197\u2013204","journal-title":"Abdom Radiol (NY)"},{"key":"1503_CR14","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/j.neurad.2022.10.006","volume":"50","author":"JS Aunan-Diop","year":"2022","unstructured":"Aunan-Diop JS, Andersen M, Friismose AI et al (2022) Virtual magnetic resonance elastography predicts the intraoperative consistency of meningiomas. J Neuroradiol 50:396\u2013401","journal-title":"J Neuroradiol"},{"key":"1503_CR15","doi-asserted-by":"publisher","unstructured":"Jung HN, Ryoo I, Suh S, Lee YH, Kim E (2022) Evaluating the elasticity of metastatic cervical lymph nodes in head and neck squamous cell carcinoma patients using DWI-based virtual MR elastography. Magn Reson Med Sci. https:\/\/doi.org\/10.2463\/mrms.mp.2022-0082","DOI":"10.2463\/mrms.mp.2022-0082"},{"key":"1503_CR16","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1148\/radiol.2020191498","volume":"295","author":"ML Kromrey","year":"2020","unstructured":"Kromrey ML, Le Bihan D, Ichikawa S, Motosugi U (2020) Diffusion-weighted MRI-based virtual elastography for the assessment of liver fibrosis. Radiology 295:127\u2013135","journal-title":"Radiology"},{"key":"1503_CR17","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1007\/s11102-021-01129-4","volume":"24","author":"K Lagerstrand","year":"2021","unstructured":"Lagerstrand K, Gaedes N, Eriksson S et al (2021) Virtual magnetic resonance elastography has the feasibility to evaluate preoperative pituitary adenoma consistency. Pituitary 24:530\u2013541","journal-title":"Pituitary"},{"key":"1503_CR18","doi-asserted-by":"crossref","unstructured":"Ota T, Hori M, Le Bihan D et al. (2021) Diffusion-based virtual MR elastography of the liver: can it be extended beyond liver fibrosis? J Clin Med 10","DOI":"10.3390\/jcm10194553"},{"key":"1503_CR19","doi-asserted-by":"publisher","first-page":"1682","DOI":"10.1002\/mrm.25180","volume":"71","author":"Z Yin","year":"2014","unstructured":"Yin Z, Magin RL, Klatt D (2014) Simultaneous MR elastography and diffusion acquisitions: diffusion-MRE (dMRE). Magn Reson Med 71:1682\u20131688","journal-title":"Magn Reson Med"},{"key":"1503_CR20","unstructured":"Lu J, Liu T, Li J, Li X, Yang J (2022) Intravoxel incoherent motion MR imaging-based virtual elastography for the assessment of placenta accreta. ISMRM 3779.\u00a0https:\/\/archive.ismrm.org\/2022\/3779.html"},{"key":"1503_CR21","unstructured":"Liu T, Lu J, Li J, Yang J (2022) Difference of stiffness between the fetal and the maternal part of the placenta by virtual magnetic resonance elastography. ISMRM 1322.\u00a0https:\/\/archive.ismrm.org\/2022\/1322.html"},{"key":"1503_CR22","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.placenta.2023.02.005","volume":"135","author":"J Deng","year":"2023","unstructured":"Deng J, Zhang A, Zhao M et al (2023) Placental perfusion using intravoxel incoherent motion MRI combined with Doppler findings in differentiating between very low birth weight infants and small for gestational age infants. Placenta 135:16\u201324","journal-title":"Placenta"},{"key":"1503_CR23","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich PA, Piven J, Hazlett HC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31:1116\u20131128","journal-title":"Neuroimage"},{"key":"1503_CR24","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1097\/AOG.0000000000003694","volume":"135","author":"JG Parchem","year":"2020","unstructured":"Parchem JG, Brock CO, Chen HY, Kalluri R, Barton JR, Sibai BM (2020) Placental growth factor and the risk of adverse neonatal and maternal outcomes. Obstet Gynecol 135:665\u2013673","journal-title":"Obstet Gynecol"},{"key":"1503_CR25","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.clinimag.2018.05.007","volume":"50","author":"EJ Song","year":"2018","unstructured":"Song EJ, Sohn YM, Seo M (2018) Diagnostic performances of shear-wave elastography and B-mode ultrasound to differentiate benign and malignant breast lesions: the emphasis on the cutoff value of qualitative and quantitative parameters. Clin Imaging 50:302\u2013307","journal-title":"Clin Imaging"},{"key":"1503_CR26","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.placenta.2020.05.003","volume":"96","author":"C Sun","year":"2020","unstructured":"Sun C, Groom KM, Oyston C, Chamley LW, Clark AR, James JL (2020) The placenta in fetal growth restriction: what is going wrong? Placenta 96:10\u201318","journal-title":"Placenta"},{"key":"1503_CR27","first-page":"1344","volume":"49","author":"X Tao","year":"2020","unstructured":"Tao X, Zhao CQ (2020) Placental pathology of fetal vascular malperfusion. Chin J Pathol 49:1344\u20131348","journal-title":"Chin J Pathol"},{"key":"1503_CR28","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.placenta.2020.03.004","volume":"93","author":"N Andescavage","year":"2020","unstructured":"Andescavage N, You W, Jacobs M et al (2020) Exploring in vivo placental microstructure in healthy and growth-restricted pregnancies through diffusion-weighted magnetic resonance imaging. Placenta 93:113\u2013118","journal-title":"Placenta"},{"key":"1503_CR29","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.placenta.2021.06.005","volume":"111","author":"J He","year":"2021","unstructured":"He J, Chen Z, Chen C, Liu P (2021) Comparative study of placental T2* and intravoxel incoherent motion in the prediction of fetal growth restriction. Placenta 111:47\u201353","journal-title":"Placenta"},{"key":"1503_CR30","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1177\/02841851211060410","volume":"64","author":"KK Nakao","year":"2023","unstructured":"Nakao KK, Kido A, Fujimoto K et al (2023) Placental functional assessment and its relationship to adverse pregnancy outcome: comparison of intravoxel incoherent motion (IVIM) MRI, T2-relaxation time, and umbilical artery Doppler ultrasound. Acta Radiol 64:370\u2013376","journal-title":"Acta Radiol"},{"key":"1503_CR31","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1080\/14767058.2017.1378334","volume":"32","author":"N Siauve","year":"2019","unstructured":"Siauve N, Hayot PH, Deloison B et al (2019) Assessment of human placental perfusion by intravoxel incoherent motion MR imaging. J Matern Fetal Neonatal Med 32:293\u2013300","journal-title":"J Matern Fetal Neonatal Med"},{"key":"1503_CR32","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.ajog.2022.08.010","volume":"228","author":"RW Redline","year":"2023","unstructured":"Redline RW, Roberts DJ, Parast MM et al (2023) Placental pathology is necessary to understand common pregnancy complications and achieve an improved taxonomy of obstetrical disease. Am J Obstet Gynecol 228:187\u2013202","journal-title":"Am J Obstet Gynecol"},{"key":"1503_CR33","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1002\/jmri.27684","volume":"54","author":"N Meng","year":"2021","unstructured":"Meng N, Fang T, Feng P et al (2021) Amide proton transfer-weighted imaging and multiple models diffusion-weighted imaging facilitates preoperative risk stratification of early-stage endometrial carcinoma. J Magn Reson Imaging 54:1200\u20131211","journal-title":"J Magn Reson Imaging"},{"key":"1503_CR34","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.placenta.2020.08.024","volume":"101","author":"HW Lai","year":"2020","unstructured":"Lai HW, Lyv GR, Wei YT, Zhou T (2020) The diagnostic value of two-dimensional shear wave elastography in gestational diabetes mellitus. Placenta 101:147\u2013153","journal-title":"Placenta"},{"key":"1503_CR35","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1007\/s00404-020-05697-x","volume":"302","author":"M Spiliopoulos","year":"2020","unstructured":"Spiliopoulos M, Kuo CY, Eranki A et al (2020) Characterizing placental stiffness using ultrasound shear-wave elastography in healthy and preeclamptic pregnancies. Arch Gynecol Obstet 302:1103\u20131112","journal-title":"Arch Gynecol Obstet"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01503-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-023-01503-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01503-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T03:03:08Z","timestamp":1700449388000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-023-01503-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,23]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1503"],"URL":"https:\/\/doi.org\/10.1186\/s13244-023-01503-9","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,23]]},"assertion":[{"value":"13 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Institutional Review Board approved the study, and informed consent was obtained from each participant.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent for the publication of the clinical details of participants was obtained from each patient.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"One of the authors (Feifei Qu) is an employee\u00a0of Siemens Healthineers. The remaining authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"153"}}