{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T23:26:57Z","timestamp":1792193217859,"version":"4.4.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T00:00:00Z","timestamp":1697328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T00:00:00Z","timestamp":1697328000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82171897"],"award-info":[{"award-number":["82171897"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003399","name":"Shanghai Science and Technology Committee","doi-asserted-by":"crossref","award":["19411965500"],"award-info":[{"award-number":["19411965500"]}],"id":[{"id":"10.13039\/501100003399","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Shanghai Municipal Key Clinical Specialty","award":["shslczdzk03202"],"award-info":[{"award-number":["shslczdzk03202"]}]},{"name":"Clinical Research Plan of SHDC","award":["SHDC2020CR1029B"],"award-info":[{"award-number":["SHDC2020CR1029B"]}]},{"name":"Clinical Research Project of Zhongshan Hospital, Fudan University","award":["2020ZSLC61"],"award-info":[{"award-number":["2020ZSLC61"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>To evaluate the image quality of reduced field-of-view (rFOV) DWI for abdominal imaging at 5.0 Tesla (T) compared with 3.0 T.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Fifteen volunteers were included into this prospective study. All the subjects underwent the 3.0 T and 5.0 T MR examinations (time interval: 2\u2009\u00b1\u20091.9 days). Free-breathing (FB), respiratory-triggered (RT), and navigator-triggered (NT) spin-echo echo-planner imaging-based rFOV-DWI examinations were conducted at 3.0 T and 5.0 T (FB<jats:sub>3.0 T<\/jats:sub>, NT<jats:sub>3.0 T<\/jats:sub>, RT<jats:sub>3.0 T<\/jats:sub>, FB<jats:sub>5.0 T<\/jats:sub>, NT<jats:sub>5.0 T<\/jats:sub>, and RT<jats:sub>5.0 T<\/jats:sub>) with two <jats:italic>b<\/jats:italic> values (<jats:italic>b<\/jats:italic>\u2009=\u20090 and 800 s\/mm<jats:sup>2<\/jats:sup>), respectively. The signal-to-noise ratio (SNR) of different acquisition approaches were determined and statistically compared. The image quality was assessed and statistically compared with a 5-point scoring system.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The SNRs of any 5.0 T DWI images were significantly higher than those of any 3.0 T DWI images for same anatomic locations. Moreover, 5.0 T rFOV-DWIs had the significantly higher sharpness scores than 3.0 T rFOV-DWIs. Similar distortion scores were observed at both 3.0 T and 5.0 T. Finally, RT<jats:sub>5.0 T<\/jats:sub> displayed the best overall image quality followed by NT<jats:sub>5.0 T<\/jats:sub>, FB<jats:sub>5.0 T<\/jats:sub>, RT<jats:sub>3.0 T<\/jats:sub>, NT<jats:sub>3.0 T<\/jats:sub> and FB<jats:sub>3.0 T<\/jats:sub> (RT<jats:sub>5.0 T<\/jats:sub>\u2009=\u20093.9\u2009\u00b1\u20090.3, NT<jats:sub>5.0 T<\/jats:sub>\u2009=\u20093.8\u2009\u00b1\u20090.3, FB<jats:sub>5.0 T<\/jats:sub>\u2009=\u20093.4\u2009\u00b1\u20090.3, RT<jats:sub>3.0 T<\/jats:sub>\u2009=\u20093.2\u2009\u00b1\u20090.4, NT<jats:sub>3.0 T<\/jats:sub>\u2009=\u20093.1\u2009\u00b1\u20090.4, and FB<jats:sub>3.0 T<\/jats:sub>\u2009=\u20092.7\u2009\u00b1\u20090.4, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The 5.0 T rFOV-DWI showed better overall image quality and improved SNR compared to 3.0 T rFOV-DWI, which holds clinical potential for identifying the abdominal abnormalities in routine practice.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Critical relevance statement<\/jats:title>\n                <jats:p>This study provided evidence that abdominal 5.0 Tesla reduced field of view diffusion-weighted imaging (5.0 T rFOV-DWI) exhibited enhanced image quality and higher SNR compared to its 3.0 Tesla counterparts, holding clinical promise for accurately visualizing abdominal abnormalities.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Key points<\/jats:title>\n                <jats:p>\u2022 rFOV-DWI was firstly integrated with high-field-MRI for visualizing various abdominal organs.<\/jats:p>\n                <jats:p>\u2022 This study indicated the feasibility of abdominal 5.0 T-rFOV-DWI.<\/jats:p>\n                <jats:p>\u2022 Better image quality was identified for 5.0 T rFOV-DWI.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Graphical Abstract<\/jats:title>\n                \n              <\/jats:sec>","DOI":"10.1186\/s13244-023-01513-7","type":"journal-article","created":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T21:01:41Z","timestamp":1697403701000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Higher field reduced FOV diffusion-weighted imaging for abdominal imaging at 5.0 Tesla: image quality evaluation compared with 3.0 Tesla"],"prefix":"10.1186","volume":"14","author":[{"given":"Yunfei","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruofan","family":"Sheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongming","family":"Dai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengsu","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,10,15]]},"reference":[{"key":"1513_CR1","doi-asserted-by":"publisher","first-page":"2164509","DOI":"10.1155\/2020\/2164509","volume":"2020","author":"Z Geng","year":"2020","unstructured":"Geng Z, Zhang Y, Yin S et al (2020) Preoperatively grading rectal cancer with the combination of intravoxel incoherent motions imaging and diffusion kurtosis imaging. Contrast Media Mol Imaging 2020:2164509","journal-title":"Contrast Media Mol Imaging"},{"key":"1513_CR2","doi-asserted-by":"publisher","first-page":"6019","DOI":"10.2147\/CMAR.S262973","volume":"12","author":"G Shi","year":"2020","unstructured":"Shi G, Han X, Wang Q et al (2020) Evaluation of multiple prognostic factors of hepatocellular carcinoma with intra-voxel incoherent motions imaging by extracting the histogram metrics. Cancer Manag Res 12:6019","journal-title":"Cancer Manag Res"},{"key":"1513_CR3","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1002\/jmri.26293","volume":"49","author":"L Tang","year":"2019","unstructured":"Tang L, Zhou XJ (2019) Diffusion MRI of cancer: from low to high b-values. J Magn Reson Imaging 49:23\u201340","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR4","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.3348\/kjr.2015.16.6.1216","volume":"16","author":"H Kim","year":"2015","unstructured":"Kim H, Lee JM, Yoon JH et al (2015) Reduced field-of-view diffusion-weighted magnetic resonance imaging of the pancreas: comparison with conventional single-shot echo-planar imaging. Korean J Radiol 16:1216\u20131225","journal-title":"Korean J Radiol"},{"key":"1513_CR5","doi-asserted-by":"publisher","first-page":"e3849","DOI":"10.1002\/nbm.3849","volume":"31","author":"I Saniour","year":"2018","unstructured":"Saniour I, Gaborit G, Perrier AL et al (2018) Electro-optic probe for real-time assessments of RF electric field produced in an MRI scanner: feasibility tests at 3 and 4.7 T. NMR Biomed 31:e3849","journal-title":"NMR Biomed"},{"key":"1513_CR6","doi-asserted-by":"publisher","first-page":"20180492","DOI":"10.1259\/bjr.20180492","volume":"92","author":"G Barisano","year":"2019","unstructured":"Barisano G, Sepehrband F, Ma S et al (2019) Clinical 7 T MRI: Are we there yet? A review about magnetic resonance imaging at ultra-high field. Br J Radiol 92:20180492","journal-title":"Br J Radiol"},{"key":"1513_CR7","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1002\/jmri.25913","volume":"47","author":"MC de Jong","year":"2018","unstructured":"de Jong MC, de Graaf P, Pouwels PJ et al (2018) 9.4 T and 17.6 T MRI of retinoblastoma: ex vivo evaluation of microstructural anatomy and disease extent compared with histopathology. J Magn Reson Imaging 47:1487\u20131497","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR8","doi-asserted-by":"publisher","first-page":"e4113","DOI":"10.1002\/nbm.4113","volume":"32","author":"M Zaiss","year":"2019","unstructured":"Zaiss M, Anemone A, Goerke S et al (2019) Quantification of hydroxyl exchange of D-Glucose at physiological conditions for optimization of glucoCEST MRI at 3, 7 and 9.4 Tesla. NMR Biomed 32:e4113","journal-title":"NMR Biomed"},{"issue":"7","key":"1513_CR9","first-page":"340","volume":"2005","author":"R Sadleir","year":"2005","unstructured":"Sadleir R, Grant S, Silver X et al (2005) Magnetic resonance electrical impedance tomography (MREIT) at 11 tesla field strength: preliminary experimental study. Int J Bioelectromagn 2005(7):340\u2013343","journal-title":"Int J Bioelectromagn"},{"key":"1513_CR10","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1002\/nbm.3091","volume":"27","author":"Z Zhang","year":"2014","unstructured":"Zhang Z, Zeng Q, Liu Y, Li C, Feng D, Wang J (2014) Assessment of the intrinsic radiosensitivity of glioma cells and monitoring of metabolite ratio changes after irradiation by 14.7-T high-resolution 1H MRS. NMR Biomed 27:547\u2013552","journal-title":"NMR Biomed"},{"key":"1513_CR11","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1002\/mrm.24156","volume":"68","author":"RM Heidemann","year":"2012","unstructured":"Heidemann RM, Ivanov D, Trampel R et al (2012) Isotropic submillimeter fMRI in the human brain at 7 T: combining reduced field-of-view imaging and partially parallel acquisitions. Magn Reson Med 68:1506\u20131516","journal-title":"Magn Reson Med"},{"key":"1513_CR12","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1002\/mrm.21167","volume":"57","author":"BJ Wilm","year":"2007","unstructured":"Wilm BJ, Svensson J, Henning A, Pruessmann KP, Boesiger P, Kollias SS (2007) Reduced field-of-view MRI using outer volume suppression for spinal cord diffusion imaging. Magn Reson Med 57:625\u2013630","journal-title":"Magn Reson Med"},{"key":"1513_CR13","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1002\/jmri.27590","volume":"54","author":"M Tanabe","year":"2021","unstructured":"Tanabe M, Higashi M, Benkert T et al (2021) Reduced field-of-view diffusion-weighted magnetic resonance imaging of the pancreas with tilted excitation plane: a preliminary study. J Magn Reson Imaging 54:715","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR14","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1016\/j.mri.2013.01.013","volume":"31","author":"CJ Wargo","year":"2013","unstructured":"Wargo CJ, Gore JC (2013) Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7 T. Magn Reson Imaging 31:810\u2013819","journal-title":"Magn Reson Imaging"},{"key":"1513_CR15","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1016\/j.mri.2010.06.025","volume":"28","author":"C von Morze","year":"2010","unstructured":"von Morze C, Kelley DA, Shepherd TM, Banerjee S, Xu D, Hess CP (2010) Reduced field-of-view diffusion-weighted imaging of the brain at 7 T. Magn Reson Imaging 28:1541\u20131545","journal-title":"Magn Reson Imaging"},{"key":"1513_CR16","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1148\/radiol.220114","volume":"306","author":"Z Shi","year":"2023","unstructured":"Shi Z, Zhao X, Zhu S et al (2023) Time-of-flight intracranial MRA at 3 T versus 5 T versus 7 T: visualization of distal small cerebral arteries. Radiology 306:207\u2013217","journal-title":"Radiology"},{"key":"1513_CR17","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1002\/jmri.28097","volume":"56","author":"Y Zhang","year":"2022","unstructured":"Zhang Y, Yang C, Liang L et al (2022) Preliminary experience of 50 T higher field abdominal diffusion-weighted MRI: agreement of apparent diffusion coefficient with 3.0 T imaging. J Magn Reson Imaging 56:1009\u20131017","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR18","first-page":"1","volume-title":"Challenges and opportunities of ultra-high field MRI","author":"A Dula","year":"2010","unstructured":"Dula A, Welch E, Creasy J et al (2010) Challenges and opportunities of ultra-high field MRI. The Third International Conference on the Development of Biomedical Engineering in Vietnam, Springer, pp 1\u20135"},{"key":"1513_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41747-021-00216-2","volume":"5","author":"B Vachha","year":"2021","unstructured":"Vachha B, Huang SY (2021) MRI with ultrahigh field strength and high-performance gradients: challenges and opportunities for clinical neuroimaging at 7 T and beyond. Eur Radiol Exp 5:1\u201318","journal-title":"Eur Radiol Exp"},{"key":"1513_CR20","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1097\/RMR.0b013e3180f612b3","volume":"18","author":"ME Ladd","year":"2007","unstructured":"Ladd ME (2007) High-field-strength magnetic resonance: potential and limits. Top Magn Reson Imaging 18:139\u2013152","journal-title":"Top Magn Reson Imaging"},{"key":"1513_CR21","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1007\/s00330-010-2029-7","volume":"21","author":"GH Welsch","year":"2011","unstructured":"Welsch GH, Apprich S, Zbyn S et al (2011) Biochemical (T2, T2* and magnetisation transfer ratio) MRI of knee cartilage: feasibility at ultra-high field (7T) compared with high field (3T) strength. Eur Radiol 21:1136\u20131143","journal-title":"Eur Radiol"},{"key":"1513_CR22","doi-asserted-by":"publisher","first-page":"109936","DOI":"10.1016\/j.ejrad.2021.109936","volume":"143","author":"F Donati","year":"2021","unstructured":"Donati F, Casini C, Cervelli R, Morganti R, Boraschi P (2021) Diffusion-weighted MRI of solid pancreatic lesions: comparison between reduced field-of-view and large field-of-view sequences. Eur J Radiol 143:109936","journal-title":"Eur J Radiol"},{"key":"1513_CR23","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1002\/jmri.25814","volume":"47","author":"Y Peng","year":"2018","unstructured":"Peng Y, Li Z, Tang H et al (2018) Comparison of reduced field-of-view diffusion-weighted imaging (DWI) and conventional DWI techniques in the assessment of rectal carcinoma at 3.0 T: image quality and histological T staging. J Magn Reson Imaging 47:967\u2013975","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR24","doi-asserted-by":"publisher","first-page":"e0155557","DOI":"10.1371\/journal.pone.0155557","volume":"11","author":"RS Samson","year":"2016","unstructured":"Samson RS, L\u00e9vy S, Schneider T et al (2016) ZOOM or non-ZOOM? Assessing spinal cord diffusion tensor imaging protocols for multi-centre studies. PLoS One 11:e0155557","journal-title":"PLoS One"},{"key":"1513_CR25","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1002\/jmri.26527","volume":"49","author":"BR Steensma","year":"2019","unstructured":"Steensma BR, Luttje M, Voogt IJ et al (2019) Comparing signal-to-noise ratio for prostate imaging at 7T and 3T. J Magn Reson Imaging 49:1446\u20131455","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR26","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1148\/radiol.2293020782","volume":"229","author":"WA Willinek","year":"2003","unstructured":"Willinek WA, Born M, Simon B et al (2003) Time-of-flight MR angiography: comparison of 3.0-T imaging and 1.5-T imaging\u2014initial experience. Radiology 229:913\u2013920","journal-title":"Radiology"},{"key":"1513_CR27","doi-asserted-by":"publisher","first-page":"2440","DOI":"10.1016\/j.jacc.2007.03.028","volume":"49","author":"AS Cheng","year":"2007","unstructured":"Cheng AS, Pegg TJ, Karamitsos TD et al (2007) Cardiovascular magnetic resonance perfusion imaging at 3-tesla for the detection of coronary artery disease: a comparison with 15-tesla. J Am Coll Cardiol 49:2440\u20132449","journal-title":"J Am Coll Cardiol"},{"key":"1513_CR28","doi-asserted-by":"publisher","first-page":"915","DOI":"10.2214\/AJR.08.1260","volume":"192","author":"H Kandpal","year":"2009","unstructured":"Kandpal H, Sharma R, Madhusudhan KS, Kapoor KS (2009) Respiratory-triggered versus breath-hold diffusion-weighted MRI of liver lesions: comparison of image quality and apparent diffusion coefficient values. AJR Am J Roentgenol 192:915\u2013922","journal-title":"AJR Am J Roentgenol"},{"key":"1513_CR29","doi-asserted-by":"publisher","first-page":"1656","DOI":"10.1002\/jmri.24929","volume":"42","author":"MW Barentsz","year":"2015","unstructured":"Barentsz MW, Taviani V, Chang JM et al (2015) Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: diagnostic value of reduced field of view DWI. J Magn Reson Imaging 42:1656\u20131665","journal-title":"J Magn Reson Imaging"},{"key":"1513_CR30","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.clbc.2013.12.001","volume":"14","author":"H Dong","year":"2014","unstructured":"Dong H, Li Y, Li H, Wang B, Hu B (2014) Study of the reduced field-of-view diffusion-weighted imaging of the breast. Clin Breast Cancer 14:265\u2013271","journal-title":"Clin Breast Cancer"},{"key":"1513_CR31","first-page":"334","volume":"39","author":"Y Lu","year":"2015","unstructured":"Lu Y, Hatzoglou V, Banerjee S et al (2015) Repeatability investigation of reduced field-of-view diffusion weighted magnetic resonance imaging on thyroid glands. J Comput Assist Tomo 39:334","journal-title":"J Comput Assist Tomo"},{"key":"1513_CR32","doi-asserted-by":"publisher","first-page":"S234","DOI":"10.1016\/j.acra.2020.12.011","volume":"28","author":"FN Harder","year":"2021","unstructured":"Harder FN, Kamal O, Kaissis GA et al (2021) Qualitative and quantitative comparison of respiratory triggered reduced field-of-view (FOV) versus full FOV diffusion weighted imaging (DWI) in pancreatic pathologies. Acad Radiol 28:S234\u2013S243","journal-title":"Acad Radiol"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01513-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-023-01513-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-023-01513-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T14:04:06Z","timestamp":1700316246000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-023-01513-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,15]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1513"],"URL":"https:\/\/doi.org\/10.1186\/s13244-023-01513-7","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,15]]},"assertion":[{"value":"21 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This prospective study was approved by our local ethics institutional review board, and all participants gave written consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The consent to publish from all authors was obtained.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"171"}}