{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T01:18:44Z","timestamp":1782523124643,"version":"3.54.5"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T00:00:00Z","timestamp":1758672000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T00:00:00Z","timestamp":1758672000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>To compare overall image quality, lesion conspicuity and detectability on 3D-T1w-GRE arterial phase high-resolution MR images with deep learning reconstruction (3D-DLR) against standard-of-care reconstruction (SOC-Recon) in patients with suspected pancreatic disease.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and methods<\/jats:title>\n            <jats:p>Patients who underwent a pancreatic MR exam with a high-resolution 3D-T1w-GRE arterial phase acquisition on a 3.0-T MR system between December 2021 and June 2022 in our center were retrospectively included. A new deep learning-based reconstruction algorithm (3D-DLR) was used to additionally reconstruct arterial phase images. Two radiologists blinded to the reconstruction type assessed images for image quality, artifacts and lesion conspicuity using a Likert scale and counted the lesions. Signal-to-noise ratio and lesion contrast-to-noise ratio were calculated for each reconstruction. Quantitative data were evaluated using paired <jats:italic>t<\/jats:italic>-tests. Ordinal data such as image quality, artifacts and lesions conspicuity were analyzed using paired-Wilcoxon tests. Interobserver agreement for image quality and artifact assessment was evaluated using Cohen\u2019s kappa.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Thirty-two patients (mean age 62 years\u2009\u00b1\u200912, 16 female) were included. 3D-DLR significantly improved SNR for each pancreatic segment and lesion CNR compared to SOC-Recon (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01), and demonstrated significantly higher average image quality score (3.34 vs 2.68, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). 3D DLR also significantly reduced artifacts compared to SOC-Recon (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01) for one radiologist.<\/jats:p>\n            <jats:p>3D-DLR exhibited significantly higher average lesion conspicuity (2.30 vs 1.85, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). The sensitivity was increased with 3D-DLR compared to SOC-Recon for both reader 1 and reader 2 (1 vs 0.88 and 0.88 vs 0.83, <jats:italic>p<\/jats:italic>\u2009=\u20090.62 for both results).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>3D-DLR images demonstrated higher overall image quality, leading to better lesion conspicuity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Critical relevance statement<\/jats:title>\n            <jats:p>3D deep learning reconstruction can be applied to gadolinium-enhanced pancreatic 3D-T1w arterial phase high-resolution images without additional acquisition time to further improve image quality and lesion conspicuity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>3D DLR has not yet been applied to pancreatic MRI high-resolution sequences.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>This method improves SNR, CNR, and overall 3D T1w arterial pancreatic image quality.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Enhanced lesion conspicuity may improve pancreatic lesion detectability.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s13244-025-02066-7","type":"journal-article","created":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T12:15:19Z","timestamp":1758716119000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["3D gadolinium-enhanced high-resolution near-isotropic pancreatic imaging at 3.0-T MR using deep-learning reconstruction"],"prefix":"10.1186","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9205-1807","authenticated-orcid":false,"given":"Sylvie","family":"Guan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Poujol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elodie","family":"Gouhier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caroline","family":"Touloupas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Delpla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabelle","family":"Boulay-Coletta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Zins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,24]]},"reference":[{"key":"2066_CR1","doi-asserted-by":"publisher","first-page":"S142","DOI":"10.1016\/j.ijsu.2015.12.053","volume":"28","author":"M Scialpi","year":"2016","unstructured":"Scialpi M, Reginelli A, D\u2019Andrea A et al (2016) Pancreatic tumors imaging: an update. Int J Surg 28:S142\u2013S155. https:\/\/doi.org\/10.1016\/j.ijsu.2015.12.053","journal-title":"Int J Surg"},{"key":"2066_CR2","doi-asserted-by":"publisher","first-page":"5267","DOI":"10.1007\/s00330-018-5565-1","volume":"28","author":"S Lee","year":"2018","unstructured":"Lee S, Kim JH, Kim SY et al (2018) Comparison of diagnostic performance between CT and MRI in differentiating non-diffuse-type autoimmune pancreatitis from pancreatic ductal adenocarcinoma. Eur Radiol 28:5267\u20135274. https:\/\/doi.org\/10.1007\/s00330-018-5565-1","journal-title":"Eur Radiol"},{"key":"2066_CR3","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1148\/radiol.10100015","volume":"257","author":"JH Kim","year":"2010","unstructured":"Kim JH, Park SH, Yu ES et al (2010) Visually isoattenuating pancreatic adenocarcinoma at dynamic-enhanced CT: frequency, clinical and pathologic characteristics, and diagnosis at imaging examinations. Radiology 257:87\u201396. https:\/\/doi.org\/10.1148\/radiol.10100015","journal-title":"Radiology"},{"key":"2066_CR4","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.3348\/kjr.2018.0931","volume":"20","author":"JH Yoon","year":"2019","unstructured":"Yoon JH, Nickel MD, Peeters JM, Lee JM (2019) Rapid imaging: recent advances in abdominal MRI for reducing acquisition time and its clinical applications. Korean J Radiol 20:1597\u20131615. https:\/\/doi.org\/10.3348\/kjr.2018.0931","journal-title":"Korean J Radiol"},{"key":"2066_CR5","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1007\/s00261-019-02254-2","volume":"45","author":"I Mannes","year":"2020","unstructured":"Mannes I, Dallongeville A, Badat N et al (2020) Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders. Abdom Radiol (NY) 45:1082\u20131091. https:\/\/doi.org\/10.1007\/s00261-019-02254-2","journal-title":"Abdom Radiol (NY)"},{"key":"2066_CR6","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/s00261-014-0196-8","volume":"40","author":"L Legrand","year":"2015","unstructured":"Legrand L, Duchatelle V, Molini\u00e9 V et al (2015) Pancreatic adenocarcinoma: MRI conspicuity and pathologic correlations. Abdom Imaging 40:85\u201394. https:\/\/doi.org\/10.1007\/s00261-014-0196-8","journal-title":"Abdom Imaging"},{"key":"2066_CR7","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1016\/j.crad.2007.03.005","volume":"62","author":"H Chandarana","year":"2007","unstructured":"Chandarana H, Babb J, Macari M (2007) Signal characteristic and enhancement patterns of pancreatic adenocarcinoma: evaluation with dynamic gadolinium enhanced MRI. Clin Radiol 62:876\u2013883. https:\/\/doi.org\/10.1016\/j.crad.2007.03.005","journal-title":"Clin Radiol"},{"key":"2066_CR8","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1097\/RCT.0000000000001221","volume":"45","author":"Y Kim","year":"2021","unstructured":"Kim Y, Hwang J, Hong SS et al (2021) Clinical feasibility of high-resolution contrast-enhanced dynamic T1-weighted magnetic resonance imaging of the upper abdomen using compressed sensing. J Comput Assist Tomogr 45:669. https:\/\/doi.org\/10.1097\/RCT.0000000000001221","journal-title":"J Comput Assist Tomogr"},{"key":"2066_CR9","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182\u20131195. https:\/\/doi.org\/10.1002\/mrm.21391","journal-title":"Magn Reson Med"},{"key":"2066_CR10","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1007\/s13244-018-0668-4","volume":"9","author":"T Sartoretti","year":"2018","unstructured":"Sartoretti T, Reischauer C, Sartoretti E et al (2018) Common artefacts encountered on images acquired with combined compressed sensing and SENSE. Insights Imaging 9:1107\u20131115. https:\/\/doi.org\/10.1007\/s13244-018-0668-4","journal-title":"Insights Imaging"},{"key":"2066_CR11","doi-asserted-by":"publisher","unstructured":"Lebel RM (2020) Performance characterization of a novel deep learning-based MR image reconstruction pipeline. Preprint at https:\/\/doi.org\/10.48550\/arXiv.2008.06559","DOI":"10.48550\/arXiv.2008.06559"},{"key":"2066_CR12","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.3390\/diagnostics11122181","volume":"11","author":"S Gassenmaier","year":"2021","unstructured":"Gassenmaier S, K\u00fcstner T, Nickel D et al (2021) Deep learning applications in magnetic resonance imaging: has the future become present? Diagnostics (Basel) 11:2181. https:\/\/doi.org\/10.3390\/diagnostics11122181","journal-title":"Diagnostics (Basel)"},{"key":"2066_CR13","doi-asserted-by":"publisher","first-page":"8447","DOI":"10.1007\/s00330-021-08008-3","volume":"31","author":"K Shanbhogue","year":"2021","unstructured":"Shanbhogue K, Tong A, Smereka P et al (2021) Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence. Eur Radiol 31:8447\u20138457. https:\/\/doi.org\/10.1007\/s00330-021-08008-3","journal-title":"Eur Radiol"},{"key":"2066_CR14","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1007\/s00261-022-03687-y","volume":"48","author":"LA Ginocchio","year":"2023","unstructured":"Ginocchio LA, Smereka PN, Tong A et al (2023) Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection. Abdom Radiol (NY) 48:282\u2013290. https:\/\/doi.org\/10.1007\/s00261-022-03687-y","journal-title":"Abdom Radiol (NY)"},{"key":"2066_CR15","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.diii.2022.11.002","volume":"104","author":"S Afat","year":"2023","unstructured":"Afat S, Herrmann J, Almansour H et al (2023) Acquisition time reduction of diffusion-weighted liver imaging using deep learning image reconstruction. Diagn Interv Imaging 104:178\u2013184. https:\/\/doi.org\/10.1016\/j.diii.2022.11.002","journal-title":"Diagn Interv Imaging"},{"key":"2066_CR16","doi-asserted-by":"publisher","first-page":"111149","DOI":"10.1016\/j.ejrad.2023.111149","volume":"168","author":"Q Chen","year":"2023","unstructured":"Chen Q, Fang S, Yuchen Y et al (2023) Clinical feasibility of deep learning reconstruction in liver diffusion-weighted imaging: improvement of image quality and impact on apparent diffusion coefficient value. Eur J Radiol 168:111149. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111149","journal-title":"Eur J Radiol"},{"key":"2066_CR17","doi-asserted-by":"publisher","unstructured":"Matsuyama T, Ohno Y, Yamamoto K et al (2022) Comparison of utility of deep learning reconstruction on 3D MRCPs obtained with three different k-space data acquisitions in patients with IPMN. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-022-08877-2","DOI":"10.1007\/s00330-022-08877-2"},{"key":"2066_CR18","doi-asserted-by":"publisher","first-page":"7585","DOI":"10.1007\/s00330-023-09703-z","volume":"33","author":"K Shiraishi","year":"2023","unstructured":"Shiraishi K, Nakaura T, Uetani H et al (2023) Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time. Eur Radiol 33:7585\u20137594. https:\/\/doi.org\/10.1007\/s00330-023-09703-z","journal-title":"Eur Radiol"},{"key":"2066_CR19","doi-asserted-by":"publisher","first-page":"2500","DOI":"10.1007\/s00330-022-09227-y","volume":"33","author":"Y Zhang","year":"2023","unstructured":"Zhang Y, Peng W, Xiao Y et al (2023) Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction. Eur Radiol 33:2500\u20132509. https:\/\/doi.org\/10.1007\/s00330-022-09227-y","journal-title":"Eur Radiol"},{"key":"2066_CR20","doi-asserted-by":"publisher","first-page":"437","DOI":"10.4274\/dir.2023.232113","volume":"29","author":"JH Son","year":"2023","unstructured":"Son JH, Lee Y, Lee H-J et al (2023) LAVA HyperSense and deep-learning reconstruction for near-isotropic (3D) enhanced magnetic resonance enterography in patients with Crohn\u2019s disease: utility in noise reduction and image quality improvement. Diagn Interv Radiol 29:437\u2013449. https:\/\/doi.org\/10.4274\/dir.2023.232113","journal-title":"Diagn Interv Radiol"},{"key":"2066_CR21","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/RLI.0000000000000825","volume":"57","author":"S Afat","year":"2022","unstructured":"Afat S, Wessling D, Afat C et al (2022) Analysis of a deep learning-based superresolution algorithm tailored to partial fourier gradient echo sequences of the abdomen at 1.5 T: reduction of breath-hold time and improvement of image quality. Invest Radiol 57:157\u2013162. https:\/\/doi.org\/10.1097\/RLI.0000000000000825","journal-title":"Invest Radiol"},{"key":"2066_CR22","doi-asserted-by":"publisher","unstructured":"Chaika M, Afat S, Wessling D et al (2022) Deep learning-based super-resolution gradient echo imaging of the pancreas: improvement of image quality and reduction of acquisition time. Diagn Interv Imaging. https:\/\/doi.org\/10.1016\/j.diii.2022.06.006","DOI":"10.1016\/j.diii.2022.06.006"},{"key":"2066_CR23","doi-asserted-by":"publisher","unstructured":"Chaika M, Brendel JM, Ursprung S et al (2024) Deep learning reconstruction of prospectively accelerated MRI of the pancreas: clinical evaluation of shortened breath-hold examinations with Dixon fat suppression. Invest Radiol. https:\/\/doi.org\/10.1097\/RLI.0000000000001110","DOI":"10.1097\/RLI.0000000000001110"},{"key":"2066_CR24","doi-asserted-by":"publisher","first-page":"109729","DOI":"10.1016\/j.ejrad.2021.109729","volume":"139","author":"W Sun","year":"2021","unstructured":"Sun W, Wang W, Zhu K et al (2021) Feasibility of compressed sensing technique for isotropic dynamic contrast-enhanced liver magnetic resonance imaging. Eur J Radiol 139:109729. https:\/\/doi.org\/10.1016\/j.ejrad.2021.109729","journal-title":"Eur J Radiol"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-025-02066-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-025-02066-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-025-02066-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T12:15:20Z","timestamp":1758716120000},"score":1,"resource":{"primary":{"URL":"https:\/\/insightsimaging.springeropen.com\/articles\/10.1186\/s13244-025-02066-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,24]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2066"],"URL":"https:\/\/doi.org\/10.1186\/s13244-025-02066-7","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,24]]},"assertion":[{"value":"22 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This is a single-center retrospective study that has received approval from an institutional review board (Groupe Ethique Recherche Medicale, IRB 00012157). Written informed consent was waived by the Institutional Review Board, but a non-opposition form was sent to all subjects (patients) in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Included in the non-opposition form mentioned above.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"J.P. is employed by GE HealthCare. M.Z. is an associate Editor for Radiology and on the Advisory Editorial Board of European Radiology (European Society of Gastrointestinal and Abdominal Radiology) and, as such, did not participate in the selection or review processes for this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"204"}}