{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T18:48:27Z","timestamp":1782326907301,"version":"3.54.5"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the environmental impact associated with CT scanners equipped with deep-learning-based image reconstruction (DLIR) compared with scanners equipped with hybrid-iterative reconstruction (HIR), focusing on electricity consumption, carbon dioxide equivalent (CO\u2082e) emissions, and iodinated contrast media (ICM) utilization in a high-volume tertiary referral center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>In this retrospective single-center study, environmental data were collected over an 18-month period from four CT scanners: two using HIR (Group 1) and two using DLIR (Group 2), including body CT examinations. DLIR-based protocols were implemented with reduced tube voltage (80\u2013100\u2009kV vs 120\u2009kV) and optimized ICM doses. Electricity consumption, CO\u2082e emissions, and ICM utilization were quantified and compared between groups. Environmental outcomes were analyzed at the scanner level and normalized per examination.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 42,300 examinations were analyzed (23,096 in Group 1; 19,204 in Group 2). Electricity consumption was 123,000 kWh for Group 1 and 66,927 kWh for Group 2, corresponding to 30.75 and 16.73 tons of CO\u2082e emissions, respectively. At the scanner level, this represented a reduction of 28,037 kWh and 7.01 tons of CO\u2082e per scanner (4.67 tons\/year). DLIR-based protocols were associated with an ICM saving of 434\u2009L over 18 months, corresponding to 4.47 tons of avoided CO\u2082e emissions and 60,730\u2009L of water preserved. Combined CO\u2082e emissions from electricity and ICM were 49.62 tons in Group 1 and 29.10 tons in Group 2.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>DLIR-based optimized protocols were associated with improved environmental metrics, supporting their potential contribution to more sustainable radiology practices in high-volume settings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical relevance statement<\/jats:title>\n                    <jats:p>Deep learning-based image reconstruction enables routine body CT protocols with lower tube voltage and reduced ICM dose, supporting a clinically feasible transition toward more sustainable CT practice in high-volume imaging workflows.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>DLIR was associated with the implementation of lower tube voltage and reduced ICM dose, supporting more sustainable CT imaging based on protocol adaptations.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>In a high-volume tertiary referral center, deep learning-based image reconstruction was associated with a substantial reduction in electricity consumption and overall CO\u2082-equivalent emissions compared with hybrid iterative reconstruction.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Optimization of contrast media dosing with deep learning-based image reconstruction contributed meaningfully to environmental benefits.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13244-026-02333-1","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T18:09:42Z","timestamp":1782324582000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reduced environmental impact in body CT imaging with deep learning reconstruction: experience of a high-volume tertiary referral center"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8280-3787","authenticated-orcid":false,"given":"Paolo Niccol\u00f2","family":"Franco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesare","family":"Maino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Gandola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cammillo","family":"Talei Franzesi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rocco","family":"Corso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"De Ponti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Ippolito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"2333_CR1","doi-asserted-by":"publisher","first-page":"215","DOI":"10.3390\/jcm12010215","volume":"12","author":"E Picano","year":"2022","unstructured":"Picano E, Mangia C, D\u2019Andrea A (2022) Climate change, carbon dioxide emissions, and medical imaging contribution. J Clin Med 12:215. https:\/\/doi.org\/10.3390\/jcm12010215","journal-title":"J Clin Med"},{"key":"2333_CR2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.240398","volume":"313","author":"CL Thiel","year":"2024","unstructured":"Thiel CL, Vigil-Garcia M, Nande S et al (2024) Environmental life cycle assessment of a U.S. hospital-based radiology practice. Radiology 313:e240398. https:\/\/doi.org\/10.1148\/radiol.240398","journal-title":"Radiology"},{"key":"2333_CR3","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s41747-024-00424-6","volume":"8","author":"A Roletto","year":"2024","unstructured":"Roletto A, Zanardo M, Bonfitto GR et al (2024) The environmental impact of energy consumption and carbon emissions in radiology departments: a systematic review. Eur Radiol Exp 8:35. https:\/\/doi.org\/10.1186\/s41747-024-00424-6","journal-title":"Eur Radiol Exp"},{"key":"2333_CR4","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1097\/MOU.0000000000001337","volume":"35","author":"J Vosshenrich","year":"2025","unstructured":"Vosshenrich J, Merkle EM, Heye T (2025) The carbon footprint of modern imaging. Curr Opin Urol 35:674\u2013678. https:\/\/doi.org\/10.1097\/MOU.0000000000001337","journal-title":"Curr Opin Urol"},{"key":"2333_CR5","doi-asserted-by":"publisher","DOI":"10.1177\/20552076251386788","volume":"11","author":"I Toker","year":"2025","unstructured":"Toker I, Jansen S, Knoche J, Lorenz D (2025) Digital innovations for sustainable radiology: reducing waste, emissions, and inefficiencies in imaging workflows. Digit Health 11:20552076251386788. https:\/\/doi.org\/10.1177\/20552076251386788","journal-title":"Digit Health"},{"key":"2333_CR6","doi-asserted-by":"publisher","first-page":"20201223","DOI":"10.1259\/bjr.20201223","volume":"94","author":"D Ippolito","year":"2021","unstructured":"Ippolito D, Maino C, Pecorelli A et al (2021) Application of low-dose CT combined with model-based iterative reconstruction algorithm in oncologic patients during follow-up: dose reduction and image quality. Br J Radiol 94:20201223. https:\/\/doi.org\/10.1259\/bjr.20201223","journal-title":"Br J Radiol"},{"key":"2333_CR7","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1007\/s10140-018-1653-4","volume":"26","author":"D Ippolito","year":"2019","unstructured":"Ippolito D, De Vito A, Franzesi CT et al (2019) Evaluation of image quality and radiation dose saving comparing knowledge model-based iterative reconstruction on 80-kV CT pulmonary angiography (CTPA) with hybrid iterative reconstruction on 100-kV CT. Emerg Radiol 26:145\u2013153. https:\/\/doi.org\/10.1007\/s10140-018-1653-4","journal-title":"Emerg Radiol"},{"key":"2333_CR8","doi-asserted-by":"publisher","first-page":"191","DOI":"10.2214\/AJR.09.2953","volume":"194","author":"AC Silva","year":"2010","unstructured":"Silva AC, Lawder HJ, Hara A et al (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194:191\u2013199. https:\/\/doi.org\/10.2214\/AJR.09.2953","journal-title":"AJR Am J Roentgenol"},{"key":"2333_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111355","volume":"172","author":"H Chen","year":"2024","unstructured":"Chen H, Li Q, Zhou L, Li F (2024) Deep learning-based algorithms for low-dose CT imaging: a review. Eur J Radiol 172:111355. https:\/\/doi.org\/10.1016\/j.ejrad.2024.111355","journal-title":"Eur J Radiol"},{"key":"2333_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2025.112520","volume":"194","author":"C Maino","year":"2026","unstructured":"Maino C, Franco PN, Szafranska E et al (2026) Improved image quality and dose reduction in liver CT using deep learning-based reconstruction: a comparative study. Eur J Radiol 194:112520. https:\/\/doi.org\/10.1016\/j.ejrad.2025.112520","journal-title":"Eur J Radiol"},{"key":"2333_CR11","doi-asserted-by":"publisher","first-page":"787","DOI":"10.3390\/diagnostics10100787","volume":"10","author":"C-C Yang","year":"2020","unstructured":"Yang C-C (2020) Evaluation of impact of factors affecting CT radiation dose for optimizing patient dose levels. Diagnostics (Basel) 10:787. https:\/\/doi.org\/10.3390\/diagnostics10100787","journal-title":"Diagnostics (Basel)"},{"key":"2333_CR12","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1007\/s12194-016-0382-1","volume":"10","author":"KJ Chang","year":"2017","unstructured":"Chang KJ, Collins S, Li B, Mayo-Smith WW (2017) Optimizing CT technique to reduce radiation dose: effect of changes in kVp, iterative reconstruction, and noise index on dose and noise in a human cadaver. Radiol Phys Technol 10:180\u2013188. https:\/\/doi.org\/10.1007\/s12194-016-0382-1","journal-title":"Radiol Phys Technol"},{"key":"2333_CR13","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","volume":"47","author":"CH McCollough","year":"2009","unstructured":"McCollough CH, Primak AN, Braun N et al (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 47:27\u201340. https:\/\/doi.org\/10.1016\/j.rcl.2008.10.006","journal-title":"Radiol Clin North Am"},{"key":"2333_CR14","doi-asserted-by":"publisher","first-page":"2979","DOI":"10.1007\/s00261-024-04221-y","volume":"49","author":"X Lin","year":"2024","unstructured":"Lin X, Gao Y, Zhu C et al (2024) Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction. Abdom Radiol (NY) 49:2979\u20132987. https:\/\/doi.org\/10.1007\/s00261-024-04221-y","journal-title":"Abdom Radiol (NY)"},{"key":"2333_CR15","doi-asserted-by":"publisher","first-page":"109","DOI":"10.4314\/mmj.v37i2.8","volume":"37","author":"X Huang","year":"2025","unstructured":"Huang X, Shang J, Xiao Y et al (2025) Deep learning-based reconstruction improves image quality in low-dose head CT angiography. Malawi Med J 37:109\u2013114. https:\/\/doi.org\/10.4314\/mmj.v37i2.8","journal-title":"Malawi Med J"},{"key":"2333_CR16","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13871","volume":"24","author":"A Svalkvist","year":"2023","unstructured":"Svalkvist A, Fagman E, Vikgren J et al (2023) Evaluation of deep-learning image reconstruction for chest CT examinations at two different dose levels. J Appl Clin Med Phys 24:e13871. https:\/\/doi.org\/10.1002\/acm2.13871","journal-title":"J Appl Clin Med Phys"},{"key":"2333_CR17","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1097\/RCT.0000000000001674","volume":"49","author":"GV Toia","year":"2025","unstructured":"Toia GV, Ananthakrishnan L (2025) The environmental impact of iodinated contrast media: strategies for optimized use and recycling. J Comput Assist Tomogr 49:203\u2013214. https:\/\/doi.org\/10.1097\/RCT.0000000000001674","journal-title":"J Comput Assist Tomogr"},{"key":"2333_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jenvman.2023.119931","volume":"351","author":"H Yan","year":"2024","unstructured":"Yan H, Zhang T, Yang Y et al (2024) Occurrence of iodinated contrast media (ICM) in water environments and their control strategies with a particular focus on iodinated by-products formation: a comprehensive review. J Environ Manage 351:119931. https:\/\/doi.org\/10.1016\/j.jenvman.2023.119931","journal-title":"J Environ Manage"},{"key":"2333_CR19","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.envres.2015.04.003","volume":"140","author":"A Mendoza","year":"2015","unstructured":"Mendoza A, Ace\u00f1a J, P\u00e9rez S et al (2015) Pharmaceuticals and iodinated contrast media in a hospital wastewater: a case study to analyse their presence and characterise their environmental risk and hazard. Environ Res 140:225\u2013241. https:\/\/doi.org\/10.1016\/j.envres.2015.04.003","journal-title":"Environ Res"},{"key":"2333_CR20","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.radi.2024.06.023","volume":"30","author":"A England","year":"2024","unstructured":"England A, Rawashdeh M, Moore N et al (2024) More sustainable use of iodinated contrast media\u2014Why? Radiography (Lond) 30:74\u201380. https:\/\/doi.org\/10.1016\/j.radi.2024.06.023","journal-title":"Radiography (Lond)"},{"key":"2333_CR21","unstructured":"National Inventory Report 2023 (2023) Greenhouse gas emissions and removals in Italy 1990\u20132021. ISPRA, Rome"},{"key":"2333_CR22","first-page":"139","volume":"32","author":"JA Seibert","year":"2004","unstructured":"Seibert JA (2004) X-ray imaging physics for nuclear medicine technologists. Part 1: basic principles of x-ray production. J Nucl Med Technol 32:139\u2013147","journal-title":"J Nucl Med Technol"},{"key":"2333_CR23","unstructured":"Bushberg J, Seibert J, Leidholdt E, Boone J (2019) The essential physics of medical imaging, 4th edn. Wolters Kluwer, Philadelphia"},{"key":"2333_CR24","unstructured":"World Resources Institute, World Business Council for Sustainable Development (2015) GHG protocol scope 2 guidance. World Resources Institute (WRI)\/World Business Council for Sustainable Development (WBCSD), Washington, DC"},{"key":"2333_CR25","unstructured":"International Energy Agency (2023) Electricity generation by source. International Energy Agency (IEA), Paris"},{"key":"2333_CR26","doi-asserted-by":"publisher","unstructured":"Nghiem DX, Yahyavi-Firouz-Abadi N, Hwang GL et al (2025) The iodine opportunity for sustainable radiology: quantifying supply-chain strategies to cut contrast\u2019s carbon and costs. J Am Coll Radiol. https:\/\/doi.org\/10.1016\/j.jacr.2025.09.027","DOI":"10.1016\/j.jacr.2025.09.027"},{"key":"2333_CR27","doi-asserted-by":"publisher","first-page":"803","DOI":"10.3390\/w13060803","volume":"13","author":"W Gerbens-Leenes","year":"2021","unstructured":"Gerbens-Leenes W, Berger M, Allan J (2021) Water footprint and life cycle assessment: the complementary strengths of analyzing global freshwater appropriation and resulting local impacts. Water 13:803. https:\/\/doi.org\/10.3390\/w13060803","journal-title":"Water"},{"key":"#cr-split#-2333_CR28.1","unstructured":"International Organization for Standardization (2014) ISO 14046:2014: Environmental management - Water footprint -Principles, requirements and guidelines. Geneva: ISO"},{"key":"#cr-split#-2333_CR28.2","unstructured":"[accessed 2025 Sept 15]. https:\/\/www.iso.org\/standard\/43263.html"},{"key":"2333_CR29","doi-asserted-by":"publisher","first-page":"3951","DOI":"10.1007\/s00330-020-06724-w","volume":"30","author":"J Greffier","year":"2020","unstructured":"Greffier J, Hamard A, Pereira F et al (2020) Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study. Eur Radiol 30:3951\u20133959. https:\/\/doi.org\/10.1007\/s00330-020-06724-w","journal-title":"Eur Radiol"},{"key":"2333_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2022.100418","volume":"9","author":"T Nj\u00f8lstad","year":"2022","unstructured":"Nj\u00f8lstad T, Jensen K, Dybwad A et al (2022) Low-contrast detectability and potential for radiation dose reduction using deep learning image reconstruction\u2014a 20-reader study on a semi-anthropomorphic liver phantom. Eur J Radiol Open 9:100418. https:\/\/doi.org\/10.1016\/j.ejro.2022.100418","journal-title":"Eur J Radiol Open"},{"key":"2333_CR31","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2214\/AJR.19.22332","volume":"215","author":"CT Jensen","year":"2020","unstructured":"Jensen CT, Liu X, Tamm EP et al (2020) Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience. AJR Am J Roentgenol 215:50\u201357. https:\/\/doi.org\/10.2214\/AJR.19.22332","journal-title":"AJR Am J Roentgenol"},{"key":"2333_CR32","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1007\/s11547-023-01607-8","volume":"128","author":"D De Santis","year":"2023","unstructured":"De Santis D, Polidori T, Tremamunno G et al (2023) Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography. Radiol Med 128:434\u2013444. https:\/\/doi.org\/10.1007\/s11547-023-01607-8","journal-title":"Radiol Med"},{"key":"2333_CR33","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.23.30189","volume":"222","author":"JH Schoen","year":"2024","unstructured":"Schoen JH, Burdette JH, West TG et al (2024) Savings in CT net scan energy consumption: assessment using dose report metrics and comparison with savings in idle state energy consumption. AJR Am J Roentgenol 222:e2330189. https:\/\/doi.org\/10.2214\/AJR.23.30189","journal-title":"AJR Am J Roentgenol"},{"key":"2333_CR34","doi-asserted-by":"publisher","unstructured":"Hehenkamp P, Obmann MM, Kamber S et al (2025) CT energy consumption savings from a rapid-reactivation power save mode for interexamination idle periods. AJR Am J Roentgenol. https:\/\/doi.org\/10.2214\/AJR.25.33951","DOI":"10.2214\/AJR.25.33951"},{"key":"2333_CR35","doi-asserted-by":"publisher","unstructured":"Carver DE, Pruthi S, Struk O et al (2025) Measuring the environmental impact of MRI and CT: a life cycle assessment. J Am Coll Radiol. https:\/\/doi.org\/10.1016\/j.jacr.2025.09.030","DOI":"10.1016\/j.jacr.2025.09.030"},{"key":"2333_CR36","doi-asserted-by":"publisher","first-page":"7386","DOI":"10.1007\/s00330-024-10793-6","volume":"34","author":"K Yoshida","year":"2024","unstructured":"Yoshida K, Nagayama Y, Funama Y et al (2024) Low tube voltage and deep-learning reconstruction for reducing radiation and contrast medium doses in thin-slice abdominal CT: a prospective clinical trial. Eur Radiol 34:7386\u20137396. https:\/\/doi.org\/10.1007\/s00330-024-10793-6","journal-title":"Eur Radiol"},{"key":"2333_CR37","doi-asserted-by":"publisher","first-page":"e367","DOI":"10.2196\/jmir.8775","volume":"19","author":"T Greenhalgh","year":"2017","unstructured":"Greenhalgh T, Wherton J, Papoutsi C et al (2017) Beyond adoption: a new framework for theorizing and evaluating nonadoption, abandonment, and challenges to the scale-up, spread, and sustainability of health and care technologies. J Med Internet Res 19:e367. https:\/\/doi.org\/10.2196\/jmir.8775","journal-title":"J Med Internet Res"},{"key":"2333_CR38","doi-asserted-by":"publisher","first-page":"115014","DOI":"10.1088\/2515-7620\/acf81b","volume":"5","author":"L Bouza","year":"2023","unstructured":"Bouza L, Bugeau A, Lannelongue L (2023) How to estimate carbon footprint when training deep learning models? A guide and review. Environ Res Commun 5:115014. https:\/\/doi.org\/10.1088\/2515-7620\/acf81b","journal-title":"Environ Res Commun"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-026-02333-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-026-02333-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-026-02333-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T18:09:53Z","timestamp":1782324593000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13244-026-02333-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2333"],"URL":"https:\/\/doi.org\/10.1186\/s13244-026-02333-1","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"8 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective, single-center observational study was conducted in accordance with the Declaration of Helsinki. This study did not require approval by the local Ethics Committee, as no patients were prospectively enrolled, and no additional examinations or interventions were performed.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The analysis was conducted retrospectively on routinely acquired, fully anonymized technical data. Informed consent was therefore not required in accordance with local regulations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"170"}}