{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T18:20:42Z","timestamp":1787682042497,"version":"build-2784847793"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Insights Imaging"],"abstract":"<jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>The angular trajectory of the vestibular aqueduct (ATVA) has been proposed as a radiographic marker for developmental endotypes of Meni\u00e8re\u2019s disease. Current ATVA measurements rely on software-based proxies because the proximal vestibular aqueduct is often below the spatial resolution of conventional CT. Photon-counting CT (PCCT) may allow direct visualization of the proximal trajectory and enable patient-specific ATVA measurement. In this retrospective study, PCCT temporal bone scans from 64 patients (128 ears) were analyzed, and ATVA was measured directly by two independent readers, alongside additional VA morphometric parameters. The mean ATVA (106.9\u00b0 \u00b1 11.7\u00b0) was consistent with previously reported values, suggesting that PCCT can approximate established measurements without relying on geometric proxies. However, reproducibility was poor: interobserver agreement for ATVA was low (ICC\u2009=\u20090.24), and intra-observer agreement varied markedly between readers (ICC\u2009=\u20090.80 vs. 0.27). This variability can be related to subjective line placement, the curved anatomy of the VA, and the need to integrate information across multiple image slices. In contrast, midpoint VA diameter measurements, particularly in the P\u00f6schl plane, demonstrated moderate to good reproducibility. Methodological standardization, such as the use of individualized oblique reconstructions or minimum intensity projections, may improve the reliability of ATVA measurements. Alternatively, other surrogate markers, such as the retrolabyrinthine bone thickness, may provide superior reproducibility while maintaining clinical relevance for endotype differentiation. Overall, despite enabling direct visualization, the current PCCT-based ATVA assessment is limited by poor reproducibility and requires methodological refinement for routine clinical implementation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      \u2022\n                      <jats:bold>Question<\/jats:bold>\n                      Photon-counting CT can\u00a0directly assess the angular trajectory of the vestibular aqueduct for Meni\u00e8re\u2019s disease endotyping, avoiding software-based proxies used as conventional CT cannot resolve its proximal anatomy.\n                    <\/jats:p>\n                    <jats:p>\n                      \u2022\n                      <jats:bold>Findings<\/jats:bold>\n                      Photon-counting CT showed a mean ATVA of 106,9\u00b0, comparable to values previously reported in the literature, but with poor inter-reader agreement.\n                    <\/jats:p>\n                    <jats:p>\n                      \u2022\n                      <jats:bold>Critical relevance statement<\/jats:bold>\n                      Photon-counting CT enables direct patient-specific assessment of the angular trajectory of the vestibular aqueduct and may support clinically meaningful endotype categorization in Meni\u00e8re\u2019s disease.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13244-026-02372-8","type":"journal-article","created":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T17:41:35Z","timestamp":1787679695000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The angular trajectory of the vestibular aqueduct: evaluation using photon-counting CT"],"prefix":"10.1186","volume":"17","author":[{"given":"Frederik","family":"Van den Kerkhof","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas","family":"Boomgaert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lesley","family":"Cockmartin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9935-5543","authenticated-orcid":false,"given":"Robert","family":"Hermans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,25]]},"reference":[{"key":"2372_CR1","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3174\/ajnr.A8933","volume":"47","author":"AF Juliano","year":"2026","unstructured":"Juliano AF, Naik PK, Romo LV et al (2026) Postnatal development of the vestibular aqueduct trajectory on CT: establishing age-specific norms to distinguish normal from arrested (hypoplastic) development. AJNR Am J Neuroradiol 47:151\u2013157","journal-title":"AJNR Am J Neuroradiol"},{"key":"2372_CR2","doi-asserted-by":"publisher","first-page":"1239422","DOI":"10.3389\/fneur.2023.1239422","volume":"14","author":"LMH De Pont","year":"2023","unstructured":"De Pont LMH, Houben MTPM, Verhagen TO et al (2023) Visualization and clinical relevance of the endolymphatic duct and sac in M\u00e9ni\u00e8re\u2019s disease. Front Neurol 14:1239422. https:\/\/doi.org\/10.3389\/fneur.2023.1239422","journal-title":"Front Neurol"},{"key":"2372_CR3","doi-asserted-by":"publisher","first-page":"e170","DOI":"10.1097\/MAO.0000000000004482","volume":"46","author":"C Br\u00fclmann","year":"2025","unstructured":"Br\u00fclmann C, Spiegel J, M\u00fchle A et al (2025) Deafness progressing to cochlear implant eligibility is eight times more likely in the hypoplastic than the degenerative endotype of Meni\u00e8re\u2019s disease. Otol Neurotol 46:e170\u2013e175","journal-title":"Otol Neurotol"},{"key":"2372_CR4","doi-asserted-by":"publisher","first-page":"e548","DOI":"10.1097\/MAO.0000000000002198","volume":"40","author":"D B\u00e4chinger","year":"2019","unstructured":"B\u00e4chinger D, Luu NN, Kempfle J et al (2019) Vestibular aqueduct morphology correlates with endolymphatic sac pathologies in Meni\u00e8re\u2019s disease\u2014a correlative histology and computed tomography study. Otol Neurotol 40:e548\u2013e555","journal-title":"Otol Neurotol"},{"key":"2372_CR5","doi-asserted-by":"publisher","first-page":"579","DOI":"10.3174\/ajnr.A7452","volume":"43","author":"JC Benson","year":"2022","unstructured":"Benson JC, Rajendran K, Lane JI et al (2022) A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualisation of critical anatomic structures at reduced radiation dose. AJNR Am J Neuroradiol 43:579\u2013584","journal-title":"AJNR Am J Neuroradiol"},{"key":"2372_CR6","doi-asserted-by":"publisher","unstructured":"Jung D, Nagururu N, Hui F et al (2023) 2D measurements of the angle of the vestibular aqueduct using CT imaging. Brain Sci 13:47. https:\/\/doi.org\/10.3390\/brainsci13010047","DOI":"10.3390\/brainsci13010047"},{"key":"2372_CR7","doi-asserted-by":"publisher","first-page":"2008","DOI":"10.3390\/biomedicines12092008","volume":"12","author":"K Xia","year":"2024","unstructured":"Xia K, Lei P, Liu Y et al (2024) Angular trajectory of the vestibular aqueduct in a cohort of Chinese patients with unilateral M\u00e9ni\u00e8re\u2019s disease: association with other imaging indices and clinical profiles. Biomedicines 12:2008. https:\/\/doi.org\/10.3390\/biomedicines12092008","journal-title":"Biomedicines"},{"key":"2372_CR8","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1186\/s13244-023-01467-w","volume":"14","author":"R Hermans","year":"2023","unstructured":"Hermans R, Boomgaert L, Cockmartin L et al (2023) Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT. Insights Imaging 14:112. https:\/\/doi.org\/10.1186\/s13244-023-01467-w","journal-title":"Insights Imaging"},{"key":"2372_CR9","doi-asserted-by":"publisher","first-page":"3349","DOI":"10.1002\/lary.31339","volume":"134","author":"Y Huang","year":"2024","unstructured":"Huang Y, Tang R, Xu N et al (2024) Association between vestibular aqueduct morphology and Meniere\u2019s disease. Laryngoscope 134:3349\u20133354. https:\/\/doi.org\/10.1002\/lary.31339","journal-title":"Laryngoscope"},{"key":"2372_CR10","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.3174\/ajnr.A8339","volume":"45","author":"AF Juliano","year":"2024","unstructured":"Juliano AF, Lin K, Shekhrajka N et al (2024) Retrolabyrinthine bone thickness as a radiologic marker for the hypoplastic endotype in Meni\u00e8re disease. AJNR Am J Neuroradiol 45:1363\u20131369","journal-title":"AJNR Am J Neuroradiol"},{"key":"2372_CR11","unstructured":"Adams JC, Liberman MC (2010) Anatomy. In: Merchant SN, Nadol JB (eds) Schuknecht\u2019s pathology of the ear, 3rd edn. People\u2019s Medical, Shelton, p 82"},{"key":"2372_CR12","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1017\/S0022215118001597","volume":"132","author":"Y Quan","year":"2018","unstructured":"Quan Y, Gao XJ, Liu J et al (2018) Variability of vestibular aqueduct measurements among axial, single-oblique and double oblique computed tomography images. J Laryngol Otol 132:875\u2013880","journal-title":"J Laryngol Otol"},{"key":"2372_CR13","doi-asserted-by":"publisher","first-page":"30","DOI":"10.3174\/ajnr.A0735","volume":"29","author":"B \u00d6zgen","year":"2008","unstructured":"\u00d6zgen B, Cunnane ME, Caruso PA, Curtin HD (2008) Comparison of 45\u00b0 oblique reformats with axial reformats in CT evaluation of the vestibular aqueduct. AJNR Am J Neuroradiol 29:30\u201334","journal-title":"AJNR Am J Neuroradiol"},{"key":"2372_CR14","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.3174\/ajnr.A0495","volume":"28","author":"S Vijayasekaran","year":"2007","unstructured":"Vijayasekaran S, Halsted MJ, Boston M et al (2007) When is the vestibular aqueduct enlarged? A statistical analysis of the normative distribution of vestibular aqueduct size. AJNR J Neuroradiol 28:1133\u20131138","journal-title":"AJNR J Neuroradiol"},{"key":"2372_CR15","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.3174\/ajnr.A4735","volume":"37","author":"AF Juliano","year":"2016","unstructured":"Juliano AF, Ting EY, Mingkwansook V et al (2016) Vestibular aqueduct measurements in the 45\u00b0 oblique (P\u00f6schl) plane. AJNR Am J Neuroradiol 37:1331\u20131337","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Insights into Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-026-02372-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13244-026-02372-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13244-026-02372-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T17:41:36Z","timestamp":1787679696000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13244-026-02372-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,25]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2372"],"URL":"https:\/\/doi.org\/10.1186\/s13244-026-02372-8","relation":{},"ISSN":["1869-4101"],"issn-type":[{"value":"1869-4101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,25]]},"assertion":[{"value":"4 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the Ethics Committee of the University Hospitals Leuven, Belgium, reference number S69789. All CT exams were clinically indicated and did not take place specifically for this study. The requirement for informed consent was waived.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. Only screenshots of part of medical images are shared and can be considered anonymous.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"207"}}