{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:51:32Z","timestamp":1775091092658,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Case Reports"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The treatment for sliding esophageal hernia with mild gastroesophageal reflux is usually conservative, but surgical treatment is recommended for refractory sliding esophageal hernia, paraesophageal hernia liable to prolapse, or paraesophageal hernia with ulceration and\/or stenosis. Robotic surgery overcomes laparoscopic pitfalls by providing steady-state three-dimensional visualization, augmented dexterity with endo-wrist movements, and superior ergonomics for the surgeon.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>To investigate robotic paraesophageal hernia repair, a literature search was conducted using PubMed with the following key words: mini invasive surgery, robotic surgery, hiatal hernia, and Nissen fundoplication. We present the case of a 44-year-old Italian woman with a 20-year history of gastroesophageal reflux disease refractory to medical treatment, who underwent robotic Nissen fundoplication. In our center, we use the da Vinci\u00ae Xi\u2122 Surgical System, which is an advanced tool for minimally invasive surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Various reports published in the literature suggested that the robot-assisted approach was effective and was associated with very low postoperative morbidity and was accompanied by satisfactory symptomatic and anatomical radiological outcomes during a follow-up period.<\/jats:p>\n                <jats:p>The robotic approach to paraesophageal repair is safe and effective with low complication rates. With increased experience, the operative time, length of stay, and complications decrease without compromising surgical principles.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13256-020-2347-6","type":"journal-article","created":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T11:03:17Z","timestamp":1580814197000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Robotic voluminous paraesophageal hernia repair: a case report and review of the literature"],"prefix":"10.1186","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6845-7080","authenticated-orcid":false,"given":"Nicola","family":"Tartaglia","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanna","family":"Pavone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandra","family":"Di Lascia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernanda","family":"Vovola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Maddalena","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alberto","family":"Fersini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Pacilli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Ambrosi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,2,4]]},"reference":[{"issue":"4","key":"2347_CR1","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1007\/s00276-011-0904-9","volume":"34","author":"C Dean","year":"2012","unstructured":"Dean C, Etienne D, Carpentier B, Gielecki J, Tubbs RS, Loukas M. Hiatal hernias. Surg Radiol Anat. 2012;34(4):291\u20139.","journal-title":"Surg Radiol Anat"},{"key":"2347_CR2","unstructured":"Watson TJ, Moritz T. Hernia, Sliding (Paraesophageal). StatPearls [Internet]. Treasure Island: StatPearls Publishing; 2019\u20132018 Oct 27."},{"issue":"2","key":"2347_CR3","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.jtcvs.2009.10.005","volume":"139","author":"JD Luketich","year":"2010","unstructured":"Luketich JD, Nason KS, Christie NA, Pennathur A, Jobe BA, Landreneau RJ, Schuchert MJ. Outcomes after a decade of laparoscopic giant paraesophageal hernia repair. J Thorac Cardiovasc Surg. 2010;139(2):395\u2013404. 404","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"6","key":"2347_CR4","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1001\/archsurg.1997.01430300028005","volume":"132","author":"G Perdikis","year":"1997","unstructured":"Perdikis G, Hinder RA, Filipi CJ, Walenz T, McBride PJ, Smith SL, Katada N, Klingler PJ. Laparoscopic paraesophageal hernia repair. Arch Surg. 1997;132(6):586\u20139.","journal-title":"Arch Surg"},{"issue":"4","key":"2347_CR5","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1067\/msy.2000.108425","volume":"128","author":"AS Geha","year":"2000","unstructured":"Geha AS, Massad MG, Snow NJ, Baue AE. A 32-year experience in 100 patients with giant paraesophageal hernia: the case for abdominal approach and selective antireflux repair. Surgery. 2000;128(4):623\u201330.","journal-title":"Surgery"},{"issue":"1","key":"2347_CR6","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/S0002-9610(99)80096-8","volume":"171","author":"MG Patti","year":"1996","unstructured":"Patti MG, Goldberg HI, Arcerito M, Bortolasi L, Tong J, Way LW. Hiatal hernia size affects lower esophageal sphincter function, esophageal acid exposure, and the degree of mucosal injury. Am J Surg. 1996;171(1):182\u20136.","journal-title":"Am J Surg"},{"key":"2347_CR7","doi-asserted-by":"publisher","unstructured":"Lebenthal A, Waterford SD, Fisichella PM. Treatment and controversies in paraesophageal hernia repair. Front Surg. 2015:2\u201313. https:\/\/doi.org\/10.3389\/fsurg.2015.00013.","DOI":"10.3389\/fsurg.2015.00013"},{"key":"2347_CR8","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1186\/1756-0500-6-451","volume":"6","author":"N Takeuchi","year":"2013","unstructured":"Takeuchi N, Nomura Y. Paraesophageal hernia with incarceration of the gastric antrum and duodenal bulb: a case report. BMC Res Notes. 2013;6:451.","journal-title":"BMC Res Notes"},{"issue":"2","key":"2347_CR9","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/S0002-9610(73)80165-5","volume":"126","author":"LD Hill","year":"1973","unstructured":"Hill LD. Incarcerated paraesophageal hernia. A surgical emergency. Am J Surg. 1973;126(2):286\u201391.","journal-title":"Am J Surg"},{"issue":"1","key":"2347_CR10","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/S0022-5223(19)43239-X","volume":"53","author":"DB Skinner","year":"1967","unstructured":"Skinner DB, Belsey RH. Surgical management of esophageal reflux and hiatus hernia. Long-term results with 1,030 patients. J Thorac Cardiovasc Surg. 1967;53(1):33\u201354.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"2347_CR11","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1007\/s11605-009-1106-1","volume":"14","author":"M Polomsky","year":"2010","unstructured":"Polomsky M, Jones CE, Sepesi B, O\u2019Connor M, Matousek A, Hu R, Raymond DP, Litle VR, Watson TJ, Peters JH. Should elective repair of intrathoracic stomach be encouraged? J Gastrointest Surg. 2010;14(2):203\u201310.","journal-title":"J Gastrointest Surg"},{"issue":"4","key":"2347_CR12","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1097\/00000658-200210000-00012","volume":"236","author":"N Stylopoulos","year":"2002","unstructured":"Stylopoulos N, Gazelle GS, Rattner DW. Paraesophageal hernias: Operation or observation? Ann Surg. 2002;236(4):492\u2013500.","journal-title":"Ann Surg"},{"issue":"4","key":"2347_CR13","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1097\/SLA.0b013e3182a4e87c","volume":"258","author":"AH Zureikat","year":"2013","unstructured":"Zureikat AH, Moser AJ, Boone BA, Bartlett DL, Zenati M, Zeh HJ 3rd. 250 robotic pancreatic resections: safety and feasibility. Ann Surg. 2013;258(4):554\u20139. discussion 559-62","journal-title":"Ann Surg"},{"issue":"4","key":"2347_CR14","first-page":"1258","volume":"20","author":"MH Hyun","year":"2013","unstructured":"Hyun MH, Lee CH, Kwon YJ, Cho SI, Jang YJ, Kim DH, Kim JH, Park SH, Mok YJ, Park SS. Robot versus laparoscopic gastrectomy for cancer by an experienced surgeon: comparison of surgery, complications and surgical stress. AnnSurg Oncol. 2013;20(4):1258\u201365.","journal-title":"AnnSurg Oncol"},{"issue":"3","key":"2347_CR15","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1007\/s00464-003-8823-4","volume":"18","author":"JJ Andujar","year":"2004","unstructured":"Andujar JJ, Papasavas PK, Birdas T, Robke J, Raftopoulos Y, Gagn\u00e9 DJ, Caushaj PF, Landreneau RJ, Keenan RJ. Laparoscopic repair of large paraesophageal hernia is associated with a low incidence of recurrence and reoperation. Surg Endosc. 2004;18(3):444\u20137.","journal-title":"Surg Endosc"},{"issue":"3","key":"2347_CR16","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/s11605-011-1743-z","volume":"16","author":"BK Oelschlager","year":"2012","unstructured":"Oelschlager BK, Petersen RP, Brunt LM, Soper NJ, Sheppard BC, Mitsumori L, Rohrmann C, Swanstrom LL, Pellegrini CA. Laparoscopic paraesophageal hernia repair: defining long-term clinical and anatomic outcomes. J Gastrointest Surg. 2012;16(3):453\u20139.","journal-title":"J Gastrointest Surg"},{"issue":"5","key":"2347_CR17","first-page":"431","volume":"85","author":"V Neri","year":"2014","unstructured":"Neri V, Ambrosi A, Fersini A, Tartaglia N, Cianci P, Lapolla F, Forlano I. Laparoscopic cholecystectomy: evaluation of liver function tests. Ann Ital Chir. 2014;85(5):431\u20137.","journal-title":"Ann Ital Chir"},{"issue":"10","key":"2347_CR18","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1177\/000313481107701018","volume":"77","author":"NT Nguyen","year":"2011","unstructured":"Nguyen NT, Christie C, Masoomi H, Matin T, Laugenour K, Hohmann S. Utilization and outcomes of laparoscopic versus open paraesophageal hernia repair. Am Surg. 2011;77(10):1353\u20137.","journal-title":"Am Surg"},{"issue":"1","key":"2347_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/00129689-200202000-00001","volume":"12","author":"GH Ballantyne","year":"2002","unstructured":"Ballantyne GH. The pitfalls of laparoscopic surgery: challenges for robotics and telerobotic surgery. Surg Laparosc Endosc Percutan Tech. 2002;12(1):1\u20135.","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"2347_CR20","first-page":"242","volume":"87","author":"P Cianci","year":"2016","unstructured":"Cianci P, Fersini A, Tartaglia N, Ambrosi A, Neri V. Are there differences between the right and left laparoscopic adrenalectomy? Our experience. Ann Ital Chir. 2016;87:242\u20136.","journal-title":"Ann Ital Chir"},{"issue":"5","key":"2347_CR21","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1007\/s00423-012-0982-0","volume":"398","author":"T Gehrig","year":"2013","unstructured":"Gehrig T, Mehrabi A, Fischer L, Kenngott H, Hinz U, Gutt CN, M\u00fcller-Stich BP. Robotic-assisted paraesophageal hernia repair--a case-control study. Langenbecks Arch Surg. 2013;398(5):691\u20136.","journal-title":"Langenbecks Arch Surg"},{"issue":"4","key":"2347_CR22","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1007\/s00464-015-4363-y","volume":"30","author":"P Cianci","year":"2016","unstructured":"Cianci P, Fersini A, Tartaglia N, Altamura A, Lizzi V, Stoppino LP, Macarini L, Ambrosi A, Neri V. Spleen assessment after laparoscopic transperitoneal left adrenalectomy: preliminary results. Surg Endosc. 2016;30(4):1503\u20137.","journal-title":"Surg Endosc"},{"key":"2347_CR23","first-page":"165","volume":"17","author":"WA Draaisma","year":"2008","unstructured":"Draaisma WA, Gooszen HG, Consten EC, Broeders IA. Mid-term results of robot-assisted laparoscopic repair of large hiatal hernia: a symptomatic and radiological prospective cohort study. Surg Technol Int. 2008;17:165\u201370.","journal-title":"Surg Technol Int"},{"issue":"3","key":"2347_CR24","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1097\/SLE.0b013e31816f85e5","volume":"18","author":"C Braumann","year":"2008","unstructured":"Braumann C, Jacobi CA, Menenakos C, Ismail M, Rueckert JC, Mueller JM. Robotic-assisted laparoscopic and thoracoscopic surgery with the da Vinci system: a 4-year experience in a single institution. Surg Laparosc Endosc Percutan Tech. 2008;18(3):260\u20136.","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"issue":"4","key":"2347_CR25","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1089\/lap.2016.0096","volume":"26","author":"CA Galvani","year":"2016","unstructured":"Galvani CA, Loebl H, Osuchukwu O, Samam\u00e9 J, Apel ME, Ghaderi I. Robotic-assisted Paraesophageal Hernia Repair: Initial Experience at a Single Institution. J Laparoendosc Adv Surg Tech A. 2016;26(4):290\u20135.","journal-title":"J Laparoendosc Adv Surg Tech A"},{"issue":"1","key":"2347_CR26","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1007\/s11701-017-0697-x","volume":"12","author":"V Vasudevan","year":"2018","unstructured":"Vasudevan V, Reusche R, Nelson E, Kaza S. Robotic paraesophageal hernia repair: a single-center experience and systematic review. J Robot Surg. 2018;12(1):81\u20136.","journal-title":"J Robot Surg"},{"issue":"1","key":"2347_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/rcs.1595","volume":"11","author":"L Morelli","year":"2015","unstructured":"Morelli L, Guadagni S, Mariniello MD, Pisano R, D'Isidoro C, Belluomini MA, Caprili G, Di Candio G, Mosca F. Robotic giant hiatal hernia repair: 3\u2009year prospective evaluation and review of the literature. Int J Med Robot. 2015;11(1):1\u20137.","journal-title":"Int J Med Robot"},{"issue":"1","key":"2347_CR28","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/S1091-255X(02)00151-8","volume":"7","author":"S Diaz","year":"2003","unstructured":"Diaz S, Brunt LM, Klingensmith ME, Frisella PM, Soper NJ. Laparoscopic paraesophageal hernia repair, a challenging operation: medium-term outcome of 116 patients. J Gastrointest Surg. 2003;7(1):59\u201367.","journal-title":"J Gastrointest Surg"},{"issue":"5","key":"2347_CR29","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/S1072-7515(00)00260-X","volume":"190","author":"M Hashemi","year":"2000","unstructured":"Hashemi M, Peters JH, DeMeester TR, Huprich JE, Quek M, Hagen JA, Crookes PF, Theisen J, DeMeester SR, Sillin LF, Bremner CG. Laparoscopic repair of large type III hiatal hernia: objective followup reveals high recurrence rate. J Am Coll Surg. 2000;190(5):553\u201360.","journal-title":"J Am Coll Surg"},{"issue":"1","key":"2347_CR30","doi-asserted-by":"publisher","first-page":"e1730","DOI":"10.1002\/rcs.1730","volume":"13","author":"Inderpal S. Sarkaria","year":"2016","unstructured":"Sarkaria IS, Latif MJ, Bianco VJ, Bains MS, Rusch VW, Jones DR, Rizk NP. Early operative outcomes and learning curve of robotic assisted giant paraesophageal hernia repair. Int J Med Robot. 2017;13(1). https:\/\/doi.org\/10.1002\/rcs.1730.","journal-title":"The International Journal of Medical Robotics and Computer Assisted Surgery"}],"container-title":["Journal of Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-020-2347-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13256-020-2347-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-020-2347-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,3]],"date-time":"2021-02-03T00:34:41Z","timestamp":1612312481000},"score":1,"resource":{"primary":{"URL":"https:\/\/jmedicalcasereports.biomedcentral.com\/articles\/10.1186\/s13256-020-2347-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,4]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["2347"],"URL":"https:\/\/doi.org\/10.1186\/s13256-020-2347-6","relation":{},"ISSN":["1752-1947"],"issn-type":[{"value":"1752-1947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,4]]},"assertion":[{"value":"22 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The ethics committee of our institution approved the study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was obtained from all individual participants included in the study. Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"25"}}