{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T09:26:15Z","timestamp":1751534775956},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T00:00:00Z","timestamp":1720483200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T00:00:00Z","timestamp":1720483200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Case Reports"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The current study presents a novel and precise surgical technique for complete reconstruction of the aortic valve using glutaraldehyde-treated autologous pericardium in a patient with aortic valve disease and endocarditis. The technique aims to provide a more effective and reproducible method for aortic valve repair, with the goal of improving outcomes and quality of life for patients with aortic valve disease.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 35-year-old Iranian male with aortic valve disease and endocarditis underwent aortic valve reconstruction surgery. Preoperative echocardiography showed a degenerative aortic valve with severe regurgitation, reduced left ventricular ejection fraction, and specific aortic root dimensions. The surgical technique involved precise measurements and calculations to design the size and shape of the new aortic valve cusps using autologous pericardium, with the goal of optimizing coaptation and function. The surgeon calculated the intercommissural distance based on the aortic annulus diameter to determine cusp size and shape. He tailored the pericardial cusps to have a height equal to 80% of the coaptation margin length. Detailed suturing techniques were used to ensure proper alignment and coaptation of the new cusps. Intraoperative evaluation of the valve function using suction and transesophageal echocardiography showed good coaptation and minimal residual regurgitation. At the 3-year follow-up, the patient had a well-functioning aortic valve with only trivial leak and was in satisfactory clinical condition.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Glutaraldehyde-treated autologous pericardium is a validated leaflet alternative, and the causes of its failure are late annular dilatation and other technique breakdowns. Current evidence reveals that aortic valve reconstruction with glutaraldehyde-treated autologous pericardium is associated with many advantages with the potential to improve patient outcomes and quality of life. Further clinical studies are warranted to evaluate the long-term durability and efficacy of this approach.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13256-024-04637-6","type":"journal-article","created":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T00:01:54Z","timestamp":1720483314000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Precise reconstruction of the aortic valve using glutaraldehyde-treated autologous pericardium in new formula: a case report"],"prefix":"10.1186","volume":"18","author":[{"given":"Feridoun","family":"Sabzi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aghigh","family":"Heydari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atefeh","family":"Asadmobini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,9]]},"reference":[{"key":"4637_CR1","volume-title":"Valvular heart disease: a companion to Braunwald\u2019s heart disease","author":"SC Malaisrie","year":"2021","unstructured":"Malaisrie SC, McCarthy PM. Surgical approach to diseases of the aortic valve and aortic root. In: Otto CM, Bonow RO, editors. Valvular heart disease: a companion to Braunwald\u2019s heart disease. 5th ed. Philadelphia: Elsevier; 2021.","edition":"5"},{"key":"4637_CR2","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.12688\/f1000research.17995.1","volume":"8","author":"C Spadaccio","year":"2019","unstructured":"Spadaccio C, Alkhamees K, Al-Attar N. Recent advances in aortic valve replacement. F1000Research. 2019;8:1159.","journal-title":"F1000Research"},{"issue":"1","key":"4637_CR3","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/S0003-4975(02)03692-5","volume":"74","author":"WT Brinkman","year":"2002","unstructured":"Brinkman WT, Williams WH, Guyton RA, Jones EL, Craver JM. Valve replacement in patients on chronic renal dialysis: implications for valve prosthesis selection. Ann Thorac Surg. 2002;74(1):37\u201342.","journal-title":"Ann Thorac Surg"},{"issue":"1","key":"4637_CR4","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.jtcvs.2012.11.012","volume":"147","author":"S Ozaki","year":"2014","unstructured":"Ozaki S, Kawase I, Yamashita H, Uchida S, Nozawa Y, Takatoh M, et\u00a0al. A total of 404 cases of aortic valve reconstruction with glutaraldehyde-treated autologous pericardium. J Thorac Cardiovasc Surg. 2014;147(1):301\u20136.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"4","key":"4637_CR5","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1510\/icvts.2010.253682","volume":"12","author":"S Ozaki","year":"2011","unstructured":"Ozaki S, Kawase I, Yamashita H, Uchida S, Nozawa Y, Matsuyama T, et\u00a0al. Aortic valve reconstruction using self-developed aortic valve plasty system in aortic valve disease. Interact Cardiovasc Thorac Surg. 2011;12(4):550\u20133.","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"2","key":"4637_CR6","first-page":"32","volume":"10","author":"JS Aluru","year":"2022","unstructured":"Aluru JS, Barsouk A, Saginala K, Rawla P, Barsouk A. Valvular Heart Disease Epidemiology. Med Sci (Basel). 2022;10(2):32.","journal-title":"Med Sci (Basel)"},{"issue":"5","key":"4637_CR7","doi-asserted-by":"publisher","first-page":"610","DOI":"10.21470\/1678-9741-2019-0304","volume":"34","author":"MPBO S\u00e1","year":"2019","unstructured":"S\u00e1 MPBO, Perazzo \u00c1M, Zhigalov K, Komarov R, Kadyraliev B, Enginoev S, et\u00a0al. Aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium (Ozaki Procedure)\u2014a promising surgical technique. Braz J Cardiovasc Surg. 2019;34(5):610\u20134.","journal-title":"Braz J Cardiovasc Surg"},{"key":"4637_CR8","doi-asserted-by":"publisher","first-page":"24","DOI":"10.21037\/jovs-20-110","volume":"8","author":"A Albertini","year":"2022","unstructured":"Albertini A, Raviola E, Zucchetta F, Brega C, Mikus E, Tripodi A. Aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium to avoid the prosthesis-patient mismatch of a severely obese 57-year-old patient\u2014a case report. J Vis Surg. 2022;8:24.","journal-title":"J Vis Surg"},{"issue":"6","key":"4637_CR9","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1093\/icvts\/ivt033","volume":"16","author":"I Kawase","year":"2013","unstructured":"Kawase I, Ozaki S, Yamashita H, Uchida S, Nozawa Y, Matsuyama T, et\u00a0al. Aortic valve reconstruction with autologous pericardium for dialysis patients. Interact Cardiovasc Thorac Surg. 2013;16(6):738\u201342.","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"6","key":"4637_CR10","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1016\/S0022-5223(19)33497-X","volume":"47","author":"VO Bj\u00f6rk","year":"1964","unstructured":"Bj\u00f6rk VO, Hultquist G. Teflon and pericardial aortic valve prostheses. J Thorac Cardiovasc Surg. 1964;47(6):693\u2013701.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"4637_CR11","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.ejcts.2005.04.041","volume":"28","author":"Z Al Halees","year":"2005","unstructured":"Al Halees Z, Al Shahid M, Al Sanei A, Sallehuddin A, Duran C. Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve? Eur J Cardiothorac Surg. 2005;28(2):200\u20135.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"7","key":"4637_CR12","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1253\/circj.CJ-14-1092","volume":"79","author":"S Ozaki","year":"2015","unstructured":"Ozaki S, Kawase I, Yamashita H, Uchida S, Takatoh M, Hagiwara S, et\u00a0al. Aortic valve reconstruction using autologous pericardium for aortic stenosis. Circulation. 2015;79(7):1504\u201310.","journal-title":"Circulation"}],"container-title":["Journal of Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-024-04637-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13256-024-04637-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-024-04637-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T00:02:48Z","timestamp":1720483368000},"score":1,"resource":{"primary":{"URL":"https:\/\/jmedicalcasereports.biomedcentral.com\/articles\/10.1186\/s13256-024-04637-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,9]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4637"],"URL":"https:\/\/doi.org\/10.1186\/s13256-024-04637-6","relation":{},"ISSN":["1752-1947"],"issn-type":[{"value":"1752-1947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,9]]},"assertion":[{"value":"25 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All participants involved in this study have provided informed consent and the study has obtained ethics approval from the Institutional Review Board under the reference number IR.KUMS.REC.1402.326.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests associated with the research, ensuring the objectivity and impartiality of the study\u2019s findings.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"314"}}