{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T04:21:35Z","timestamp":1744258895130,"version":"3.40.4"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Case Reports"],"DOI":"10.1186\/s13256-025-05113-5","type":"journal-article","created":{"date-parts":[[2025,4,5]],"date-time":"2025-04-05T01:24:26Z","timestamp":1743816266000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Perioperative anesthesia management for elderly patients with permanent pacemakers undergoing retropubic prostatectomy in Ethiopia East Africa: a case report and review of the literature"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-3250-101X","authenticated-orcid":false,"given":"Eniyew Assimie","family":"Alemu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Biruk Adie","family":"Admass","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Demelash Gedefaye","family":"Anteneh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Desyibelew Chanie","family":"Mekonnen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-0266-5708","authenticated-orcid":false,"given":"Molla Amsalu","family":"Tadesse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,4]]},"reference":[{"issue":"3","key":"5113_CR1","first-page":"42","volume":"3","author":"M Kotsakou","year":"2015","unstructured":"Kotsakou M, Kioumis I, Lazaridis G, Pitsiou G, Lampaki S, Papaiwannou A, et al. Pacemaker insertion. Ann Transl Med. 2015;3(3):42.","journal-title":"Ann Transl Med"},{"key":"5113_CR2","first-page":"643","volume":"48","author":"C Wm","year":"1960","unstructured":"Wm C. A transistorized self-contained implantable pacemaker for the long-term correction of complete heart block. Surgery. 1960;48:643\u201354.","journal-title":"Surgery"},{"issue":"2","key":"5113_CR3","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1111\/j.1076-7460.2006.04815.x","volume":"15","author":"SM Bailey","year":"2006","unstructured":"Bailey SM, Wilkoff BL. Complications of pacemakers and defibrillators in the elderly. Am J Geriatr Cardiol. 2006;15(2):102\u20137.","journal-title":"Am J Geriatr Cardiol"},{"issue":"14","key":"5113_CR4","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1161\/CIRCULATIONAHA.113.001555","volume":"128","author":"R Lampert","year":"2013","unstructured":"Lampert R. Managing with pacemakers and implantable cardioverter defibrillators. Circulation. 2013;128(14):1576\u201385.","journal-title":"Circulation"},{"issue":"10","key":"5113_CR5","volume":"15","author":"P Sahu","year":"2023","unstructured":"Sahu P, Acharya S, Totade M. Evolution of pacemakers and implantable cardioverter defibrillators (ICDs) in cardiology. Cureus. 2023;15(10): e46389.","journal-title":"Cureus"},{"key":"5113_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10102192","author":"B Rauch","year":"2021","unstructured":"Rauch B, Salzwedel A, Bjarnason-Wehrens B, Albus C, Meng K, Schmid JP, et al. Cardiac rehabilitation in German speaking countries of Europe-evidence-based guidelines from Germany, Austria and Switzerland LLKardReha-DACH\u2014part 1. J Clin Med. 2021. https:\/\/doi.org\/10.3390\/jcm10102192.","journal-title":"J Clin Med."},{"issue":"5","key":"5113_CR7","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1097\/ALN.0000000000000839","volume":"123","author":"MA Rozner","year":"2015","unstructured":"Rozner MA, Schulman PM. Creating an anesthesiologist-run pacemaker and defibrillator service: closing the perioperative care gap for these patients. Anesthesiology. 2015;123(5):990\u20132.","journal-title":"Anesthesiology"},{"issue":"29","key":"5113_CR8","doi-asserted-by":"crossref","first-page":"2699","DOI":"10.1093\/eurheartj\/ehy373","volume":"39","author":"CJ Leuner","year":"2018","unstructured":"Leuner CJ, Weldegerima AH. Cardiology services in Ethiopia. Eur Heart J. 2018;39(29):2699\u2013700.","journal-title":"Eur Heart J"},{"issue":"1","key":"5113_CR9","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.cjca.2016.09.008","volume":"33","author":"E Duceppe","year":"2017","unstructured":"Duceppe E, Parlow J, MacDonald P, Lyons K, McMullen M, Srinathan S, et al. Canadian cardiovascular society guidelines on perioperative cardiac risk assessment and management for patients who undergo noncardiac surgery. Can J Cardiol. 2017;33(1):17\u201332.","journal-title":"Can J Cardiol"},{"key":"5113_CR10","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.xjon.2023.03.001","volume":"14","author":"S Argaw","year":"2023","unstructured":"Argaw S, Genetu A, Vervoort D, Agwar FD. The state of cardiac surgery in Ethiopia. JTCVS Open. 2023;14:261\u20139.","journal-title":"JTCVS Open"},{"key":"5113_CR11","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.bjan.2013.02.003","volume":"64","author":"AG Rapsang","year":"2014","unstructured":"Rapsang AG, Bhattacharyya P. Pacemakers and implantable cardioverter defibrillators-general and anesthetic considerations. Rev Bras Anestesiol. 2014;64:205\u201314.","journal-title":"Rev Bras Anestesiol"},{"key":"5113_CR12","doi-asserted-by":"publisher","DOI":"10.4103\/2394-6954.180655","author":"S Govindswamy","year":"2015","unstructured":"Govindswamy S, Geetha S. Anesthesia management of an elderly patient having permanent pacemaker for total hip replacement. Karnataka Anaesth J. 2015. https:\/\/doi.org\/10.4103\/2394-6954.180655.","journal-title":"Karnataka Anaesth J"},{"issue":"4","key":"5113_CR13","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1093\/bja\/66.4.509","volume":"66","author":"S Finfer","year":"1991","unstructured":"Finfer S. Pacemaker failure on induction of anaesthesia. BJA Br J Anaesth. 1991;66(4):509\u201312.","journal-title":"BJA Br J Anaesth"},{"key":"5113_CR14","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1023\/A:1009748202307","volume":"2","author":"RW Peters","year":"1998","unstructured":"Peters RW, Gold MR. Reversible prolonged pacemaker failure due to electrocautery. J Interv Card Electrophysiol. 1998;2:343\u20134.","journal-title":"J Interv Card Electrophysiol"},{"issue":"7","key":"5113_CR15","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1016\/j.hrthm.2010.12.023","volume":"8","author":"GH Crossley","year":"2011","unstructured":"Crossley GH, Poole JE, Rozner MA, Asirvatham SJ, Cheng A, Chung MK, et al. The Heart Rhythm Society (HRS)\/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management this document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Heart Rhythm. 2011;8(7):1114\u201354.","journal-title":"Heart Rhythm"},{"issue":"9","key":"5113_CR16","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1093\/europace\/eux353","volume":"20","author":"A Bonny","year":"2018","unstructured":"Bonny A, Ngantcha M, Jeilan M, Okello E, Kaviraj B, Talle MA, et al. Statistics on the use of cardiac electronic devices and interventional electrophysiological procedures in Africa from 2011 to 2016: report of the Pan African Society of Cardiology (PASCAR) Cardiac Arrhythmias and Pacing Task Forces. Ep Europace. 2018;20(9):1513\u201326.","journal-title":"Ep Europace"},{"issue":"4","key":"5113_CR17","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1097\/ALN.0000000000002571","volume":"130","author":"PM Schulman","year":"2019","unstructured":"Schulman PM, Treggiari MM, Yanez ND, Henrikson CA, Jessel PM, Dewland TA, et al. Electromagnetic interference with protocolized electrosurgery dispersive electrode positioning in patients with implantable cardioverter defibrillators. Anesthesiology. 2019;130(4):530\u201340.","journal-title":"Anesthesiology"},{"issue":"11","key":"5113_CR18","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1093\/bjaed\/mkw020","volume":"16","author":"HC Bryant","year":"2016","unstructured":"Bryant HC, Roberts PR, Diprose P. Perioperative management of patients with cardiac implantable electronic devices. BJA Education. 2016;16(11):388\u201396.","journal-title":"BJA Education"},{"key":"5113_CR19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12872-019-01312-3","volume":"20","author":"J Liu","year":"2020","unstructured":"Liu J, Wen L, Yao S, Zheng P, Zhao S, Yang J. Adverse clinical events caused by pacemaker battery depletion: two case reports. BMC Cardiovasc Disord. 2020;20:1\u20135.","journal-title":"BMC Cardiovasc Disord"},{"key":"5113_CR20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13104-015-1818-0","volume":"9","author":"M Salahuddin","year":"2016","unstructured":"Salahuddin M, Cader FA, Nasrin S, Chowdhury MZ. The pacemaker-Twiddler\u2019s syndrome: an infrequent cause of pacemaker failure. BMC Res Notes. 2016;9:1\u20135.","journal-title":"BMC Res Notes"},{"key":"5113_CR21","first-page":"627","volume-title":"Editorial III: implanted cardiac pacemakers and defibrillators in anaesthetic practice","author":"S Senthuran","year":"2002","unstructured":"Senthuran S, Toff W, Vuylsteke A, Solesbury P, Menon D. Editorial III: implanted cardiac pacemakers and defibrillators in anaesthetic practice. Oxford: Oxford University Press; 2002. p. 627\u201331."},{"issue":"4","key":"5113_CR22","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/S0733-8651(18)30650-7","volume":"3","author":"ML Dohrmann","year":"1985","unstructured":"Dohrmann ML, Goldschlager NF. Myocardial stimulation threshold in patients with cardiac pacemakers: effect of physiologic variables, pharmacologic agents, and lead electrodes. Cardiol Clin. 1985;3(4):527\u201337.","journal-title":"Cardiol Clin"},{"issue":"15","key":"5113_CR23","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/0002-9149(85)90420-5","volume":"56","author":"GA Lamas","year":"1985","unstructured":"Lamas GA, Rebecca GS, Braunwald NS, Antman EM. Pacemaker malfunction after nitrous oxide anesthesia. Am J Cardiol. 1985;56(15):995.","journal-title":"Am J Cardiol"},{"issue":"6","key":"5113_CR24","first-page":"565","volume":"58","author":"S Thiagarajah","year":"1983","unstructured":"Thiagarajah S, Azar I, Agres M, Lear E. Pacemaker malfunction associated with positive-pressure ventilation. J Am Soc Anesth. 1983;58(6):565\u20136.","journal-title":"J Am Soc Anesth"},{"key":"5113_CR25","volume-title":"Pacemaker syndrome","author":"AM Iqbal","year":"2024","unstructured":"Iqbal AM, Jamal SF. Pacemaker syndrome. Treasure Island: StatPearls Publishing; 2024."},{"issue":"6","key":"5113_CR26","first-page":"588","volume":"60","author":"JM Forand","year":"1984","unstructured":"Forand JM, Schweiss JF. Pacemaker syndrome during anesthesia. J Am Soc Anesth. 1984;60(6):588\u20139.","journal-title":"J Am Soc Anesth"},{"issue":"9","key":"5113_CR27","doi-asserted-by":"crossref","first-page":"736","DOI":"10.4103\/ija.IJA_346_17","volume":"61","author":"M Chakravarthy","year":"2017","unstructured":"Chakravarthy M, Prabhakumar D, George A. Anaesthetic consideration in patients with cardiac implantable electronic devices scheduled for surgery. Indian J Anaesth. 2017;61(9):736\u201343.","journal-title":"Indian J Anaesth"},{"issue":"4","key":"5113_CR28","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1097\/ALN.0000000000003217","volume":"132","author":"American Society of Anesthesiologists","year":"2020","unstructured":"American Society of Anesthesiologists. Patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators 2020: an updated report by the American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Cardiac Implantable Electronic Devices: Erratum. Anesthesiology. 2020;132(4):938.","journal-title":"Anesthesiology"}],"container-title":["Journal of Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-025-05113-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13256-025-05113-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-025-05113-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T16:42:54Z","timestamp":1744216974000},"score":1,"resource":{"primary":{"URL":"https:\/\/jmedicalcasereports.biomedcentral.com\/articles\/10.1186\/s13256-025-05113-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,4]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5113"],"URL":"https:\/\/doi.org\/10.1186\/s13256-025-05113-5","relation":{},"ISSN":["1752-1947"],"issn-type":[{"type":"electronic","value":"1752-1947"}],"subject":[],"published":{"date-parts":[[2025,4,4]]},"assertion":[{"value":"11 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The participants provided written informed consent, which included the assurance of his right to decline participation and maintain confidentiality.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. Additionally a copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"157"}}