{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T16:26:37Z","timestamp":1764433597311,"version":"3.38.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T00:00:00Z","timestamp":1741046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T00:00:00Z","timestamp":1741046400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Yunnan Province Science and Technology Department & Kunming Medical University Joint Special Fund for Applied Basic Research","award":["202301AY070001-042"],"award-info":[{"award-number":["202301AY070001-042"]}]},{"name":"Research and Application of Epidemiology, Pathogenesis, Diagnosis and Treatment of Cardiovascular Diseases in High Altitude of Yunnan Province Project","award":["202103AC100004"],"award-info":[{"award-number":["202103AC100004"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Case Reports"],"DOI":"10.1186\/s13256-025-05122-4","type":"journal-article","created":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T12:03:11Z","timestamp":1741089791000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Stent-induced hypersensitivity leading to refractory in-stent restenosis: a case report"],"prefix":"10.1186","volume":"19","author":[{"given":"Menghuai","family":"Ma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiong","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,3,4]]},"reference":[{"issue":"4","key":"5122_CR1","doi-asserted-by":"publisher","first-page":"E137","DOI":"10.1002\/ccd.26017","volume":"87","author":"Y Nakajima","year":"2016","unstructured":"Nakajima Y, Itoh T, Morino Y. Metal allergy to everolimus-eluting cobalt chromium stents confirmed by positive skin testing as a cause of recurrent multivessel in-stent restenosis. Catheter Cardiovasc Interv. 2016;87(4):E137-142.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"3","key":"5122_CR2","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1161\/CIRCULATIONAHA.114.012658","volume":"131","author":"F Otsuka","year":"2015","unstructured":"Otsuka F, Yahagi K, Ladich E, et al. Hypersensitivity reaction in the US Food and Drug Administration-approved second-generation drug-eluting stents: histopathological assessment with ex vivo optical coherence tomography. Circulation. 2015;131(3):322\u20134.","journal-title":"Circulation"},{"issue":"9","key":"5122_CR3","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1016\/j.jacc.2006.02.017","volume":"47","author":"S Wheatcroft","year":"2006","unstructured":"Wheatcroft S, Byrne J, Thomas M, et al. Life-threatening coronary artery spasm following sirolimus-eluting stent deployment. J Am Coll Cardiol. 2006;47(9):1911\u20132.","journal-title":"J Am Coll Cardiol"},{"issue":"6S1","key":"5122_CR4","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.carrev.2016.12.020","volume":"18","author":"A Jurado-Roman","year":"2017","unstructured":"Jurado-Roman A, Lopez-Lluva MT, Sanchez-Perez I, et al. Bioresorbable vascular scaffold to treat malignant in-stent restenosis in a patient with nickel allergy. Cardiovasc Revasc Med. 2017;18(6S1):38\u201340.","journal-title":"Cardiovasc Revasc Med"},{"issue":"1","key":"5122_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/ehjcr\/ytaa001","volume":"4","author":"T Jimba","year":"2020","unstructured":"Jimba T, Hashikata T, Matsushita M, et al. Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report. Eur Heart J Case Rep. 2020;4(1):1\u20135.","journal-title":"Eur Heart J Case Rep"},{"issue":"1","key":"5122_CR6","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s12928-020-00734-7","volume":"36","author":"J Aoki","year":"2021","unstructured":"Aoki J, Tanabe K. Mechanisms of drug-eluting stent restenosis. Cardiovasc Interv Ther. 2021;36(1):23\u20139.","journal-title":"Cardiovasc Interv Ther"},{"issue":"13","key":"5122_CR7","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1016\/j.jacc.2020.08.002","volume":"76","author":"ID Moussa","year":"2020","unstructured":"Moussa ID, Mohananey D, Saucedo J, et al. Trends and outcomes of restenosis after coronary stent implantation in the United States. J Am Coll Cardiol. 2020;76(13):1521\u201331.","journal-title":"J Am Coll Cardiol"},{"key":"5122_CR8","doi-asserted-by":"publisher","first-page":"1003322","DOI":"10.3389\/fbioe.2022.1003322","volume":"10","author":"W Hu","year":"2022","unstructured":"Hu W, Jiang J. Hypersensitivity and in-stent restenosis in coronary stent materials. Front Bioeng Biotechnol. 2022;10:1003322.","journal-title":"Front Bioeng Biotechnol"},{"issue":"2","key":"5122_CR9","doi-asserted-by":"publisher","first-page":"65","DOI":"10.2310\/6620.2011.10055","volume":"22","author":"JL Basko-Plluska","year":"2011","unstructured":"Basko-Plluska JL, Thyssen JP, Schalock PC. Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis. 2011;22(2):65\u201379.","journal-title":"Dermatitis"},{"issue":"1","key":"5122_CR10","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1038\/s41569-019-0234-x","volume":"17","author":"S Torii","year":"2020","unstructured":"Torii S, Jinnouchi H, Sakamoto A, et al. Drug-eluting coronary stents: insights from preclinical and pathology studies. Nat Rev Cardiol. 2020;17(1):37\u201351.","journal-title":"Nat Rev Cardiol"},{"key":"5122_CR11","first-page":"149","volume":"7","author":"J Bennett","year":"2013","unstructured":"Bennett J, Dubois C. A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease. Biologics. 2013;7:149\u201359.","journal-title":"Biologics"},{"issue":"22","key":"5122_CR12","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.1016\/j.jcin.2021.08.078","volume":"14","author":"ND van Hemert","year":"2021","unstructured":"van Hemert ND, Voskuil M, Rozemeijer R, et al. 3-year clinical outcomes after implantation of permanent-polymer versus polymer-free stent: ReCre8 landmark analysis. JACC Cardiovasc Interv. 2021;14(22):2477\u201386.","journal-title":"JACC Cardiovasc Interv"},{"issue":"2","key":"5122_CR13","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jacc.2020.05.026","volume":"76","author":"S Kufner","year":"2020","unstructured":"Kufner S, Ernst M, Cassese S, et al. 10-Year outcomes from a randomized trial of polymer-free versus durable polymer drug-eluting coronary stents. J Am Coll Cardiol. 2020;76(2):146\u201358.","journal-title":"J Am Coll Cardiol"},{"key":"5122_CR14","doi-asserted-by":"publisher","first-page":"109750","DOI":"10.1016\/j.msec.2019.109750","volume":"103","author":"AM Soliman","year":"2019","unstructured":"Soliman AM, Tolba SA, Sharafeldin IM, et al. Ni-free, built-in nanotubular drug eluting stents: experimental and theoretical insights. Mater Sci Eng C Mater Biol Appl. 2019;103:109750.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"3","key":"5122_CR15","doi-asserted-by":"publisher","first-page":"71","DOI":"10.3390\/bioengineering5030071","volume":"5","author":"A Sakamoto","year":"2018","unstructured":"Sakamoto A, Jinnouchi H, Torii S, et al. Understanding the impact of stent and scaffold material and strut design on coronary artery thrombosis from the basic and clinical points of view. Bioengineering. 2018;5(3):71.","journal-title":"Bioengineering"},{"issue":"9","key":"5122_CR16","doi-asserted-by":"publisher","first-page":"ytab370","DOI":"10.1093\/ehjcr\/ytab370","volume":"5","author":"H Yamamoto","year":"2021","unstructured":"Yamamoto H, Yoshida N, Kondo T, et al. In-stent restenosis due to delayed healing of abluminal bioresorbable polymer everolimus-eluting stent: insight from histopathological evaluation with directional coronary atherectomy. Eur Heart J Case Rep. 2021;5(9):ytab370.","journal-title":"Eur Heart J Case Rep"}],"container-title":["Journal of Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-025-05122-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13256-025-05122-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-025-05122-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T12:03:15Z","timestamp":1741089795000},"score":1,"resource":{"primary":{"URL":"https:\/\/jmedicalcasereports.biomedcentral.com\/articles\/10.1186\/s13256-025-05122-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,4]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5122"],"URL":"https:\/\/doi.org\/10.1186\/s13256-025-05122-4","relation":{},"ISSN":["1752-1947"],"issn-type":[{"value":"1752-1947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,4]]},"assertion":[{"value":"16 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"96"}}