{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T18:51:34Z","timestamp":1782499894662,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T00:00:00Z","timestamp":1782432000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T00:00:00Z","timestamp":1782432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Leipzig"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Case Reports"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Percutaneous sacroiliac screw fixation is an effective option for unstable pelvic ring fractures. It is minimally invasive, causes little soft tissue damage, and reduces complication risk. Nevertheless, complications such as screw loosening or nerve root damage are reported. Although vascular injuries are also described, detailed management strategies are rarely found in the literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>A 58-year-old white German female suffered polytrauma, including a type c posterior pelvic ring fracture, after a fall from great height. The fracture was treated with screw osteosynthesis of the anterior and posterior ring. After transfer to our hospital for further treatment, X-ray and CT revealed sacroiliac screw malposition with suspected external iliac vein injury. During an interdisciplinary procedure involving angiology and trauma surgery, the screw was removed, and subsequent bleeding from the injured vein was controlled by coiling before a new sacroiliac screw was inserted. The subsequent hospital stay remained complication free.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Sacroiliac screw osteosynthesis is a safe and established procedure for unstable pelvic ring injuries. However, due to complex anatomy such as sacral dysmorphia and difficult fracture patterns, complications including nerve or vascular injury may occur. Preventing these requires careful preoperative planning to identify a suitable corridor. While 2D-fluoroscopy is well established intraoperatively, 3D-navigation further reduces malposition risk in challenging anatomy. In cases of screw malposition, exact analysis and interdisciplinary consultation are essential to determine the safest and most effective treatment and to successfully manage complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key clinical message<\/jats:title>\n                    <jats:p>The incorrect positioning of a sacroiliac screw can lead to serious complications. Exact analysis and the full spectrum of complication management is necessary for successful treatment of misplaced screws in pelvic surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13256-026-06278-3","type":"journal-article","created":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T18:09:35Z","timestamp":1782497375000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Successful minimal-invasive management of misplaced sacroiliac screw perforating the left external iliac vein: an interdisciplinary intervention by angiology and traumatology\u2014a case report"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-1753-6758","authenticated-orcid":false,"given":"Titus","family":"Drossel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"H\u00f6ch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Do\u00df","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrej","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Kleber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,26]]},"reference":[{"key":"6278_CR1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-024-05447-7","author":"Smith","year":"2020","unstructured":"Smith. High-impact trauma and pelvic fractures: a review. J Trauma Acute Care Surg. 2020. https:\/\/doi.org\/10.1007\/s00402-024-05447-7.","journal-title":"J Trauma Acute Care Surg"},{"key":"6278_CR2","doi-asserted-by":"publisher","DOI":"10.26676\/jevtm.22378","author":"J Giuliani","year":"2024","unstructured":"Giuliani J, Guelfi R, Cremonini C, Tartaglia D, Zocco G, Chiarugi M, Coccolini F. Anatomy and classification of pelvic trauma. J Endovasc Resusc Trauma Manag. 2024. https:\/\/doi.org\/10.26676\/jevtm.22378.","journal-title":"J Endovasc Resusc Trauma Manag"},{"key":"6278_CR3","first-page":"189","volume":"27","author":"H Melek","year":"2021","unstructured":"Melek H, et al. Posterior pelvic ring injuries: Evaluation and surgical management. J Orthop. 2021;27:189\u201398.","journal-title":"J Orthop"},{"issue":"11","key":"6278_CR4","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.73638","volume":"16","author":"T Funayama","year":"2024","unstructured":"Funayama T, Yanagisawa Y, Ogata Y, Okuwaki S, Tatsumura M. A Misplaced S2 Alar-Iliac Screw Causing L5 Spinal Nerve Injury: A Report of a Rare Case. Cureus. 2024;16(11): e73638. https:\/\/doi.org\/10.7759\/cureus.73638.","journal-title":"Cureus"},{"issue":"9","key":"6278_CR5","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1097\/BOT.0000000000001236","volume":"32","author":"JD Gire","year":"2018","unstructured":"Gire JD, Jiang SY, Gardner MJ, Bishop JA. Percutaneous versus open treatment of posterior pelvic ring injuries: changes in practice patterns over time. J Orthop Trauma. 2018;32(9):457\u201360. https:\/\/doi.org\/10.1097\/BOT.0000000000001236.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"6278_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2025.112169","volume":"56","author":"J Booth","year":"2025","unstructured":"Booth J, Gabbe PB, Neeman T, Perriman DM, Smith PN. Outcomes of surgically treated posterior pelvic fractures in an Australian population: a multicenter study. Injury. 2025;56(3): 112169. https:\/\/doi.org\/10.1016\/j.injury.2025.112169.","journal-title":"Injury"},{"issue":"10","key":"6278_CR7","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1097\/BOT.0b013e3181cf0404","volume":"24","author":"MJ Gardner","year":"2010","unstructured":"Gardner MJ, Morshed S, Nork SE, et al. Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra. J Orthop Trauma. 2010;24(10):622\u20139.","journal-title":"J Orthop Trauma"},{"key":"6278_CR8","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199704150-00002","author":"NA Ebraheim","year":"1997","unstructured":"Ebraheim NA, Xu R, Biyani A, Nadaud MC. Morphologic considerations of the first sacral pedicle for iliosacral screw placement. Spine (Phila Pa 1976). 1997. https:\/\/doi.org\/10.1097\/00007632-199704150-00002.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"6278_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2025.112171","volume":"56","author":"S Hoppler","year":"2025","unstructured":"Hoppler S, Notov D, Zeidler S, Pieroh P, Einhorn S, Kleber C, H\u00f6ch A, Osterhoff G. Which screw corridors can be used for bilateral fragility fractures of the pelvis with a transverse fracture component (FFP IVb)? Injury. 2025;56(2): 112171. https:\/\/doi.org\/10.1016\/j.injury.2025.112171.","journal-title":"Injury"},{"key":"6278_CR10","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/00003086-198905000-00009","volume":"242","author":"JM Matta","year":"1989","unstructured":"Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83\u201397.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"6278_CR11","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","volume":"9","author":"ML Routt Jr","year":"1995","unstructured":"Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9(3):207\u201314. https:\/\/doi.org\/10.1097\/00005131-199506000-00005.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"6278_CR12","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","volume":"11","author":"ML Routt Jr","year":"1997","unstructured":"Routt ML Jr, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11(8):584\u20139. https:\/\/doi.org\/10.1097\/00005131-199711000-00007.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"6278_CR13","first-page":"200","volume":"35","author":"JD Smith","year":"2021","unstructured":"Smith JD, Miller AN, Xu Y, et al. Comparison of 2D fluoroscopy and 3D navigation in iliosacral screw placement. J Orthop Trauma. 2021;35(4):200\u20136.","journal-title":"J Orthop Trauma"},{"issue":"12","key":"6278_CR14","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1097\/BOT.0000000000000092","volume":"28","author":"A Matityahu","year":"2014","unstructured":"Matityahu A, Kahler D, Krettek C, St\u00f6ckle U, Grutzner PA, Messmer P, Ljungqvist J, Gebhard F. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study. J Orthop Trauma. 2014;28(12):707\u201310. https:\/\/doi.org\/10.1097\/BOT.0000000000000092.","journal-title":"J Orthop Trauma"},{"key":"6278_CR15","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181d862db","volume-title":"Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique navigated vs","author":"J Zwingmann","year":"2010","unstructured":"Zwingmann J, Konrad G, Mehlhorn AT, S\u00fcdkamp NP, Oberst M. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique navigated vs. Conventional: J TraumaDec; 2010. https:\/\/doi.org\/10.1097\/TA.0b013e3181d862db."},{"key":"6278_CR16","doi-asserted-by":"publisher","first-page":"12254","DOI":"10.1038\/s41598-023-39165-8","volume":"13","author":"A Kramer","year":"2023","unstructured":"Kramer A, Naisan M, Kindel S, et al. Retrospective evaluation of percutaneous 3D-navigated screw fixation for fragility fractures of the sacrum: technical notes and four-year experience. Sci Rep. 2023;13:12254. https:\/\/doi.org\/10.1038\/s41598-023-39165-8.","journal-title":"Sci Rep"},{"issue":"4","key":"6278_CR17","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.ocl.2015.06.005","volume":"46","author":"JA Iorio","year":"2015","unstructured":"Iorio JA, Jakoi AM, Rehman S. Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop Clin North Am. 2015;46(4):511\u201321. https:\/\/doi.org\/10.1016\/j.ocl.2015.06.005.","journal-title":"Orthop Clin North Am"},{"issue":"2","key":"6278_CR18","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1097\/00005131-200502000-00005","volume":"19","author":"C Collinge","year":"2005","unstructured":"Collinge C, Coons D, Aschenbrenner J. Risks to the superior gluteal neurovascular bundle during percutaneous iliosacral screw insertion: an anatomical cadaver study. J Orthop Trauma. 2005;19(2):96\u2013101.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"6278_CR19","doi-asserted-by":"publisher","first-page":"110","DOI":"10.4103\/0974-8237.142303","volume":"5","author":"HR Alvis-Miranda","year":"2014","unstructured":"Alvis-Miranda HR, Farid-Escorcia H, Alcal\u00e1-Cerra G, Castellar-Leones SM, Moscote-Salazar LR. Sacroiliac screw fixation: A mini review of surgical technique. J Craniovertebr Junction Spine. 2014;5(3):110\u20133. https:\/\/doi.org\/10.4103\/0974-8237.142303.","journal-title":"J Craniovertebr Junction Spine"},{"issue":"1","key":"6278_CR20","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s00113-008-1546-1","volume":"113","author":"G Konrad","year":"2010","unstructured":"Konrad G, Zwingmann J, Kotter E, S\u00fcdkamp N, Oberst M. Variabilit\u00e4t der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Unfallchirurg. 2010;113(1):29\u201335. https:\/\/doi.org\/10.1007\/s00113-008-1546-1.","journal-title":"Unfallchirurg"},{"key":"6278_CR21","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.ijscr.2020.01.004","volume":"66","author":"JM Alkhateeb","year":"2020","unstructured":"Alkhateeb JM, Chelli SS, Aljawder AA. Percutaneous removal of sacroiliac screw following iatrogenic neurologic injury in posterior pelvic ring injury: A case report. Int J Surg Case Rep. 2020;66:416\u201320. https:\/\/doi.org\/10.1016\/j.ijscr.2020.01.004.","journal-title":"Int J Surg Case Rep"}],"container-title":["Journal of Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13256-026-06278-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-026-06278-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13256-026-06278-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T18:29:34Z","timestamp":1782498574000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13256-026-06278-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,26]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6278"],"URL":"https:\/\/doi.org\/10.1186\/s13256-026-06278-3","relation":{},"ISSN":["1752-1947"],"issn-type":[{"value":"1752-1947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,26]]},"assertion":[{"value":"25 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was not required for this single case report, in accordance with the institutional policy.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"346"}}