{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T08:21:22Z","timestamp":1791534082889,"version":"4.3.4"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"This study is supported by Alzheimer\u2019s Disease Research Center (ADRC) center grant","award":["P30 AG072972"],"award-info":[{"award-number":["P30 AG072972"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Accurate quantification of tau binding from <jats:sup>18<\/jats:sup>F-PI-2620 PET requires kinetic modeling and an input function. We aimed to implement a non-invasive Image-derived input function (IDIF) using the state-of-the-art total-body uEXPLORER PET\/CT scanner to quantify tau binding and tracer delivery rate from <jats:sup>18<\/jats:sup>F-PI-2620 in the brain. Additionally, we investigated the impact of scan duration on the quantification of kinetic parameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              <jats:sup>18<\/jats:sup>F-PI-2620 total-body PET dynamic (90\u00a0min) data from 15 elderly (66\u201392 years) participants were acquired. Time-activity curves were obtained from grey matter regions of interest (ROIs) known to be affected in Alzheimer\u2019s disease, including the medial temporal lobe, posterior cingulate, and lateral parietal cortex. These curves were fitted to the two-tissue compartmental model (2TCM) using a subject-specific IDIF (plasma and metabolite corrected) derived from the descending aorta. ROI-specific kinetic parameters were estimated for different scan durations ranging from 10 to 90\u00a0min. The parameters included blood fraction volume (v<jats:sub>b<\/jats:sub>), rate constants (K<jats:sub>1<\/jats:sub>, k<jats:sub>2<\/jats:sub>, k<jats:sub>3<\/jats:sub>, k<jats:sub>4<\/jats:sub>), total distribution volume (V<jats:sub>T<\/jats:sub>), distribution volume ratio (DVR), and tracer arrival delay. Logan graphical analysis was also used to estimate V<jats:sub>T<\/jats:sub> and compared with 2TCM. Differences in kinetic parameters were observed between ROIs, including significant reduction in tracer delivery rate (K<jats:sub>1<\/jats:sub>) in the medial temporal lobe (q\u2009&lt;\u20090.001). All kinetic parameters remained relatively stable (compared to parameters quantified with full 90-minute data) after the 60-minute scan window across all ROIs (<jats:italic>r<\/jats:italic>\u2009\u2265\u20090.89; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), with K<jats:sub>1<\/jats:sub> showing high stability after 30\u00a0min of scan duration (<jats:italic>r<\/jats:italic>\u2009\u2265\u20090.92; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Excellent correlation was observed between V<jats:sub>T<\/jats:sub> estimated using 2TCM and Logan plot analysis (<jats:italic>r<\/jats:italic>\u2009\u2265\u20090.96; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>This study demonstrated the utility of IDIF from a lager blood pool, derived using the total-body PET in quantifying <jats:sup>18<\/jats:sup>F-PI-2620 kinetics in the brain. Our findings suggest that a 60-minute scan window may be required for the reliable quantification of kinetic parameters using IDIF, whereas a 30-minute scan time may be sufficient for the quantification of K<jats:sub>1<\/jats:sub>.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s13550-025-01260-4","type":"journal-article","created":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:52:39Z","timestamp":1748613159000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Kinetic modeling of 18F-PI-2620 binding in the brain using an image-derived input function with total-body PET"],"prefix":"10.1186","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9178-6509","authenticated-orcid":false,"given":"Anjan","family":"Bhattarai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily Nicole","family":"Holy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiran","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin A.","family":"Spencer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guobao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"DeCarli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Audrey P.","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,30]]},"reference":[{"key":"1260_CR1","doi-asserted-by":"crossref","unstructured":"Kroth H, Oden F, Molette J, Schieferstein H, Capotosti F, Mueller A et al. Discovery and preclinical characterization of [18F]PI-2620, a next-generation tau PET tracer for the assessment of tau pathology in Alzheimer\u2019s disease and other tauopathies. Eur J Nucl Med Mol Imaging [Internet]. 2019 [cited 2024 Feb 11];46:2178\u201389. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC6667408\/","DOI":"10.1007\/s00259-019-04397-2"},{"key":"1260_CR2","doi-asserted-by":"crossref","unstructured":"Song M, Beyer L, Kaiser L, Barthel H, van Eimeren T, Marek K et al. Binding characteristics of [18F]PI-2620 distinguish the clinically predicted tau isoform in different tauopathies by PET. J Cereb Blood Flow Metab [Internet]. 2021 [cited 2024 Feb 6];41:2957\u201372. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC8545042\/","DOI":"10.1177\/0271678X211018904"},{"key":"1260_CR3","first-page":"920","volume":"61","author":"S Bullich","year":"2020","unstructured":"Bullich S, Barret O, Constantinescu C, Sandiego C, Mueller A, Berndt M, et al. Evaluation of dosimetry, quantitative methods, and Test-Retest variability of 18F-PI-2620 PET for the assessment of Tau deposits in the human brain. J Nucl Med Off Publ Soc Nucl Med. 2020;61:920\u20137.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"key":"1260_CR4","first-page":"911","volume":"61","author":"A Mueller","year":"2020","unstructured":"Mueller A, Bullich S, Barret O, Madonia J, Berndt M, Papin C, et al. Tau PET imaging with 18F-PI-2620 in patients with alzheimer disease and healthy controls: A First-in-Humans study. J Nucl Med Off Publ Soc Nucl Med. 2020;61:911\u20139.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"key":"1260_CR5","doi-asserted-by":"publisher","first-page":"2215","DOI":"10.1038\/s41380-023-02024-z","volume":"28","author":"M Wu","year":"2023","unstructured":"Wu M, Chen Z, Jiang M, Bao B, Li D, Yin X, et al. Friend or foe: role of pathological Tau in neuronal death. Mol Psychiatry. 2023;28:2215\u201327.","journal-title":"Mol Psychiatry"},{"key":"1260_CR6","doi-asserted-by":"crossref","unstructured":"Mormino EC, Toueg TN, Azevedo C, Castillo JB, Guo W, Nadiadwala A et al. Tau PET imaging with 18F-PI-2620 in aging and neurodegenerative diseases. Eur J Nucl Med Mol Imaging [Internet]. 2021 [cited 2024 Feb 6];48:2233\u201344. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC7755737\/","DOI":"10.1007\/s00259-020-04923-7"},{"key":"1260_CR7","doi-asserted-by":"publisher","unstructured":"Bischof GN, Brendel M, Barthel H, Theis H, Barbe M, Bartenstein P et al. Improved Tau PET SUVR Quantification in 4-Repeat Tau Phenotypes with [ 18 F]PI-2620. J Nucl Med [Internet]. 2024 [cited 2024 Jun 29];65:952\u20135. Available from: http:\/\/jnm.snmjournals.org\/lookup\/doi\/https:\/\/doi.org\/10.2967\/jnumed.123.265930","DOI":"10.2967\/jnumed.123.265930"},{"key":"1260_CR8","doi-asserted-by":"publisher","unstructured":"Bullich S, Mueller A, De Santi S, Koglin N, Krause S, Kaplow J et al. Evaluation of tau deposition using 18F-PI-2620 PET in MCI and early AD subjects\u2014a MissionAD tau sub-study. Alzheimers Res Ther [Internet]. 2022 [cited 2024 Feb 15];14:105. Available from: https:\/\/doi.org\/10.1186\/s13195-022-01048-x","DOI":"10.1186\/s13195-022-01048-x"},{"key":"1260_CR9","doi-asserted-by":"crossref","unstructured":"van der Weijden CWJ, Mossel P, Bartels AL, Dierckx RAJO, Luurtsema G, Lammertsma AA et al. Non-invasive kinetic modelling approaches for quantitative analysis of brain PET studies. Eur J Nucl Med Mol Imaging [Internet]. 2023 [cited 2024 Feb 6];50:1636\u201350. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC10119247\/","DOI":"10.1007\/s00259-022-06057-4"},{"key":"1260_CR10","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1186\/s13550-023-01050-w","volume":"13","author":"T Volpi","year":"2023","unstructured":"Volpi T, Maccioni L, Colpo M, Debiasi G, Capotosti A, Ciceri T, et al. An update on the use of image-derived input functions for human PET studies: new hopes or old illusions? EJNMMI Res. 2023;13:97.","journal-title":"EJNMMI Res"},{"key":"1260_CR11","doi-asserted-by":"crossref","unstructured":"Zanotti-Fregonara P, Chen K, Liow J-S, Fujita M, Innis RB. Image-derived input function for brain PET studies: many challenges and few opportunities. J Cereb Blood Flow Metab [Internet]. 2011 [cited 2024 Feb 7];31:1986\u201398. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3208145\/","DOI":"10.1038\/jcbfm.2011.107"},{"key":"1260_CR12","doi-asserted-by":"crossref","unstructured":"Wang Y, Li E, Cherry SR, Wang G, Total-Body PETK. Modeling and Potential Opportunities Using Deep Learning. PET Clin [Internet]. 2021 [cited 2024 Jun 17];16:613\u201325. Available from: https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1556859821000481","DOI":"10.1016\/j.cpet.2021.06.009"},{"key":"1260_CR13","doi-asserted-by":"crossref","unstructured":"Badawi RD, Shi H, Hu P, Chen S, Xu T, Price PM et al. First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*. J Nucl Med [Internet]. 2019 [cited 2024 Feb 6];60:299\u2013303. Available from: https:\/\/jnm.snmjournals.org\/content\/60\/3\/299","DOI":"10.2967\/jnumed.119.226498"},{"key":"1260_CR14","first-page":"861","volume":"62","author":"BA Spencer","year":"2021","unstructured":"Spencer BA, Berg E, Schmall JP, Omidvari N, Leung EK, Abdelhafez YG, et al. Performance evaluation of the uEXPLORER Total-Body PET\/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long axial field of view. J Nucl Med Off Publ Soc Nucl Med. 2021;62:861\u201370.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"key":"1260_CR15","doi-asserted-by":"publisher","unstructured":"Holy EN, Li E, Bhattarai A, Fletcher E, Alfaro ER, Harvey DJ et al. Non-invasive quantification of 18F-florbetaben with total-body EXPLORER PET. EJNMMI Res [Internet]. 2024 [cited 2024 Jun 24];14:39. Available from: https:\/\/doi.org\/10.1186\/s13550-024-01104-7","DOI":"10.1186\/s13550-024-01104-7"},{"key":"1260_CR16","doi-asserted-by":"publisher","unstructured":"Song M, Scheifele M, Barthel H, van Eimeren T, Beyer L, Marek K et al. Feasibility of short imaging protocols for [18F]PI-2620 tau-PET in progressive supranuclear palsy. Eur J Nucl Med Mol Imaging [Internet]. 2021 [cited 2024 Feb 6];48:3872\u201385. Available from: https:\/\/doi.org\/10.1007\/s00259-021-05391-3","DOI":"10.1007\/s00259-021-05391-3"},{"key":"1260_CR17","doi-asserted-by":"publisher","unstructured":"Braak H, Braak E. Neuropathological stageing of Alzheimer-related changes. Acta Neuropathol (Berl) [Internet]. 1991 [cited 2024 Feb 11];82:239\u201359. Available from: https:\/\/doi.org\/10.1007\/BF00308809","DOI":"10.1007\/BF00308809"},{"key":"1260_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cpet.2020.09.006","volume":"16","author":"L Nardo","year":"2021","unstructured":"Nardo L, Abdelhafez YG, Spencer BA, Badawi RD. Clinical implementation of Total-Body PET\/CT at university of California, Davis. PET Clin. 2021;16:1\u20137.","journal-title":"PET Clin"},{"key":"1260_CR19","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","volume":"17","author":"M Jenkinson","year":"2002","unstructured":"Jenkinson M, Bannister P, Brady M, Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage. 2002;17:825\u201341.","journal-title":"NeuroImage"},{"key":"1260_CR20","doi-asserted-by":"crossref","unstructured":"Fischl B. FreeSurfer. NeuroImage [Internet]. 2012 [cited 2024 Feb 7];62:774\u201381. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3685476\/","DOI":"10.1016\/j.neuroimage.2012.01.021"},{"key":"1260_CR21","doi-asserted-by":"crossref","unstructured":"Fischl B, Salat DH, Busa E, Albert M, Dieterich M, Haselgrove C et al. Whole Brain Segmentation: Automated Labeling of Neuroanatomical Structures in the Human Brain. Neuron [Internet]. 2002 [cited 2024 Feb 11];33:341\u201355. Available from: https:\/\/www.cell.com\/neuron\/abstract\/S0896-6273(02)00569-X","DOI":"10.1016\/S0896-6273(02)00569-X"},{"key":"1260_CR22","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1016\/j.neuroimage.2006.01.021","volume":"31","author":"RS Desikan","year":"2006","unstructured":"Desikan RS, S\u00e9gonne F, Fischl B, Quinn BT, Dickerson BC, Blacker D, et al. An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest. NeuroImage. 2006;31:968\u201380.","journal-title":"NeuroImage"},{"key":"1260_CR23","doi-asserted-by":"publisher","unstructured":"Meindl M, Zatcepin A, Gn\u00f6rich J, Scheifele M, Zaganjori M, Gro\u00df M et al. Assessment of [18F]PI-2620 Tau-PET Quantification via Non-Invasive Automatized Image Derived Input Function. Eur J Nucl Med Mol Imaging [Internet]. 2024 [cited 2024 Jun 4]; Available from: https:\/\/doi.org\/10.1007\/s00259-024-06741-7","DOI":"10.1007\/s00259-024-06741-7"},{"key":"1260_CR24","doi-asserted-by":"publisher","unstructured":"Bhattarai A, Holy EN, Li E, Wang Y, Spencer BA, Wang G et al. Comparison of delay correction methods to estimate 18F-florbetaben kinetics in the brain using an image derived input function on total-body EXPLORER PET. Alzheimers Dement [Internet]. 2023 [cited 2024 Feb 6];19:e079502. Available from: https:\/\/onlinelibrary.wiley.com\/doi\/abs\/https:\/\/doi.org\/10.1002\/alz.079502","DOI":"10.1002\/alz.079502"},{"key":"1260_CR25","first-page":"1274","volume":"63","author":"G Wang","year":"2022","unstructured":"Wang G, Nardo L, Parikh M, Abdelhafez YG, Li E, Spencer BA, et al. Total-Body PET multiparametric imaging of Cancer using a Voxelwise strategy of compartmental modeling. J Nucl Med Off Publ Soc Nucl Med. 2022;63:1274\u201381.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"key":"1260_CR26","doi-asserted-by":"publisher","unstructured":"Innis RB, Cunningham VJ, Delforge J, Fujita M, Gjedde A, Gunn RN et al. Consensus Nomenclature for in vivo Imaging of Reversibly Binding Radioligands. J Cereb Blood Flow Metab [Internet]. 2007 [cited 2024 Feb 7];27:1533\u20139. Available from: https:\/\/doi.org\/10.1038\/sj.jcbfm.9600493","DOI":"10.1038\/sj.jcbfm.9600493"},{"key":"1260_CR27","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/S0969-8051(00)00137-2","volume":"27","author":"J Logan","year":"2000","unstructured":"Logan J. Graphical analysis of PET data applied to reversible and irreversible tracers. Nucl Med Biol. 2000;27:661\u201370.","journal-title":"Nucl Med Biol"},{"key":"1260_CR28","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1001\/jamaneurol.2022.0676","volume":"79","author":"CB Young","year":"2022","unstructured":"Young CB, Winer JR, Younes K, Cody KA, Betthauser TJ, Johnson SC, et al. Divergent cortical Tau positron emission tomography patterns among patients with preclinical alzheimer disease. JAMA Neurol. 2022;79:592\u2013603.","journal-title":"JAMA Neurol"},{"key":"1260_CR29","doi-asserted-by":"publisher","unstructured":"Lowe VJ, Bruinsma TJ, Wiste HJ, Min H-K, Weigand SD, Fang P et al. Cross-sectional associations of tau-PET signal with cognition in cognitively unimpaired adults. Neurology [Internet]. 2019 [cited 2024 Jun 28];93. Available from: https:\/\/www.neurology.org\/doi\/https:\/\/doi.org\/10.1212\/WNL.0000000000007728","DOI":"10.1212\/WNL.0000000000007728"},{"key":"1260_CR30","doi-asserted-by":"publisher","first-page":"S411","DOI":"10.3233\/JAD-141467","volume":"42","author":"CE Wierenga","year":"2014","unstructured":"Wierenga CE, Hays CC, Zlatar ZZ. Cerebral blood flow measured by arterial spin labeling MRI as a preclinical marker of Alzheimer\u2019s disease. J Alzheimers Dis JAD. 2014;42:S411\u20139.","journal-title":"J Alzheimers Dis JAD"},{"key":"1260_CR31","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.3233\/JAD-201474","volume":"81","author":"KJ Bangen","year":"2021","unstructured":"Bangen KJ, Thomas KR, Sanchez DL, Edmonds EC, Weigand AJ, Delano-Wood L, et al. Entorhinal perfusion predicts future memory decline, neurodegeneration, and white matter hyperintensity progression in older adults. J Alzheimers Dis JAD. 2021;81:1711\u201325.","journal-title":"J Alzheimers Dis JAD"},{"key":"1260_CR32","doi-asserted-by":"crossref","unstructured":"Bernetti C, D\u2019Andrea V, Buoso A, Barbalace I, Greco F, Pilato F et al. Arterial Spin Labeling MRI in Alzheimer\u2019s Disease: A Systematic Review of Cerebral Perfusion Biomarkers. J Neuroimaging [Internet]. 2025 [cited 2025 Apr 2];35:e70035. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC11909582\/","DOI":"10.1111\/jon.70035"},{"key":"1260_CR33","doi-asserted-by":"publisher","unstructured":"Kimura Y, Naganawa M, Shidahara M, Ikoma Y, Watabe H. PET kinetic analysis \u2014Pitfalls and a solution for the Logan plot. Ann Nucl Med [Internet]. 2007 [cited 2025 Apr 12];21:1\u20138. Available from: http:\/\/link.springer.com\/https:\/\/doi.org\/10.1007\/BF03033993","DOI":"10.1007\/BF03033993"},{"key":"1260_CR34","doi-asserted-by":"crossref","unstructured":"Morris ED, Endres CJ, Schmidt KC, Christian BT, Muzic RF, Fisher RE. Kinetic Modeling in Positron Emission Tomography. Emiss Tomogr [Internet]. Elsevier; 2004 [cited 2024 Jun 2]. pp. 499\u2013540. Available from: https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/B9780127444826500260","DOI":"10.1016\/B978-012744482-6.50026-0"},{"key":"1260_CR35","doi-asserted-by":"publisher","unstructured":"Sari H, Mingels C, Alberts I, Hu J, Buesser D, Shah V et al. First results on kinetic modelling and parametric imaging of dynamic 18F-FDG datasets from a long axial FOV PET scanner in oncological patients. Eur J Nucl Med Mol Imaging [Internet]. 2022 [cited 2024 Jun 20];49:1997\u20132009. Available from: https:\/\/link.springer.com\/https:\/\/doi.org\/10.1007\/s00259-021-05623-6","DOI":"10.1007\/s00259-021-05623-6"},{"key":"1260_CR36","doi-asserted-by":"publisher","unstructured":"Reed MB, Godbersen GM, Vraka C, Rausch I, Ponce De Le\u00f3n M, Popper V et al. Comparison of cardiac image-derived input functions for quantitative whole body [18F]FDG imaging with arterial blood sampling. Front Physiol [Internet]. 2023 [cited 2025 Mar 18];14:1074052. Available from: https:\/\/www.frontiersin.org\/articles\/https:\/\/doi.org\/10.3389\/fphys.2023.1074052\/full","DOI":"10.3389\/fphys.2023.1074052\/full"},{"key":"1260_CR37","doi-asserted-by":"publisher","unstructured":"Provid\u00eancia L, Van Der Weijden CWJ, Mohr P, Van Sluis J, Van Snick JH, Slart RHJA et al. Can Internal Carotid Arteries Be Used for Noninvasive Quantification of Brain PET Studies? J Nucl Med [Internet]. 2024 [cited 2024 Jun 20];65:600\u20136. Available from: http:\/\/jnm.snmjournals.org\/lookup\/doi\/https:\/\/doi.org\/10.2967\/jnumed.123.266675","DOI":"10.2967\/jnumed.123.266675"}],"container-title":["EJNMMI Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13550-025-01260-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13550-025-01260-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13550-025-01260-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:52:43Z","timestamp":1748613163000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmires.springeropen.com\/articles\/10.1186\/s13550-025-01260-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1260"],"URL":"https:\/\/doi.org\/10.1186\/s13550-025-01260-4","relation":{},"ISSN":["2191-219X"],"issn-type":[{"value":"2191-219X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,30]]},"assertion":[{"value":"22 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval for this study was obtained from the UC Davis Institutional Review Board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All the participants recruited in the study were part of the UC Davis Alzheimer\u2019s Disease Research Center, over 65 years of age and gave written informed consent.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Consent to publish has been received from all participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"62"}}