{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T20:41:58Z","timestamp":1789764118331,"version":"4.0.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,9,10]],"date-time":"2021-09-10T00:00:00Z","timestamp":1631232000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,10]],"date-time":"2021-09-10T00:00:00Z","timestamp":1631232000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Antimicrob Resist Infect Control"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives\/purpose<\/jats:title>\n                <jats:p>High-touch surfaces are a critical reservoir in the spread of nosocomial infections. Although disinfection and infection control protocols are well developed, they lack the ability to passively reduce the pathogenic load of high-touch surfaces. Copper and its alloys have been suggested as a surface that exhibit continuous biocidal effects. Antimicrobial studies on these surfaces are prevalent, while virucidal studies are not as well explored. The goal of this study was to first determine the virucidal activity of a copper\u2013nickel\u2013zinc alloy and to then examine the effect of soiling and virus preparation on virucidal activity.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A baculovirus vector was used as an easily quantifiable model of an infectious enveloped animal cell virus. Droplets containing virus were deposited on surfaces and allowed to stay wet using humidity control or were dried onto the surface. Virus was then recovered from the surface and assayed for infectivity. To examine how the composition of the droplet affected the survival of the virus, 3 different soiling conditions were tested. The first two were recommended by\u00a0the United States Environmental Protection Agency and the third consisted of cell debris resulting from virus amplification.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A copper\u2013nickel\u2013zinc alloy was shown to have strong virucidal effects for an enveloped\u00a0virus. Copper, nickel, and zinc ions were all shown to leach from the alloy surface and are the likely cause of virucidal activity by this surface. Virucidal activity was achieved under moderate soiling but lost under high soiling generated by routine virus amplification procedures. The surface was able to repeatably inactivate dried virus droplets under moderate soiling conditions, but unable to do so for virus droplets kept wet using high humidity.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Ion leaching was associated with virucidal activity in both wet and dried virus conditions. Soiling protected the virus by quenching metal ions, and not by inhibiting leaching. The composition of the solution containing virus plays a critical role in evaluating the virucidal activity of surfaces and surface coatings.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13756-021-01001-x","type":"journal-article","created":{"date-parts":[[2021,9,10]],"date-time":"2021-09-10T10:03:06Z","timestamp":1631268186000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Virus matrix interference on assessment of virucidal activity of high-touch surfaces designed to prevent hospital-acquired infections"],"prefix":"10.1186","volume":"10","author":[{"given":"Sadru-Dean","family":"Walji","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark R.","family":"Bruder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9393-5558","authenticated-orcid":false,"given":"Marc G.","family":"Aucoin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,10]]},"reference":[{"key":"1001_CR1","unstructured":"Scott II RD. The direct medical cost of healthcare-associated infections in U.S. Hospitals and the benefits of prevention. Technical Report CS200891-A, Centers for Disease Control and Prevention. 2009."},{"issue":"5","key":"1001_CR2","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1111\/ina.12170","volume":"25","author":"C Beggs","year":"2015","unstructured":"Beggs C, Knibbs LD, Johnson GR, Morawska L. Environmental contamination and hospital-acquired infection: factors that are easily overlooked. Indoor Air. 2015;25(5):462\u201374.","journal-title":"Indoor Air"},{"issue":"12","key":"1001_CR3","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1002\/jhm.2632","volume":"11","author":"A Kovacs-Litman","year":"2016","unstructured":"Kovacs-Litman A, Wong K, Shojania KG, Callery S, Vearncombe M, Leis JA. Do physicians clean their hands? Insights from a covert observational study: Covert Observation of Hand Hygiene. J Hosp Med. 2016;11(12):862\u20134.","journal-title":"J Hosp Med"},{"issue":"7","key":"1001_CR4","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1086\/660357","volume":"32","author":"FA Manian","year":"2011","unstructured":"Manian FA, Griesenauer S, Senkel D, Setzer JM, Doll SA, Perry AM, Wiechens M. Isolation of Acinetobacter baumannii complex and methicillin-resistant Staphylococcus aureus from hospital rooms following terminal cleaning and disinfection: can we do better? Infect Control Hosp Epidemiol. 2011;32(7):667\u201372.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"5","key":"1001_CR5","doi-asserted-by":"publisher","first-page":"1341","DOI":"10.1128\/AEM.01952-09","volume":"76","author":"C Espirito Santo","year":"2010","unstructured":"Espirito Santo C, Morais PV, Grass G. Isolation and characterization of bacteria resistant to metallic copper surfaces. Appl Environ Microbiol. 2010;76(5):1341\u20138.","journal-title":"Appl Environ Microbiol"},{"issue":"3","key":"1001_CR6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/BF03355432","volume":"2","author":"H Michels","year":"2008","unstructured":"Michels H, Moran W, Michel J. Antimicrobial properties of copper alloy surfaces, with a focus on hospital-acquired infections. Int J Metalcast. 2008;2(3):47\u201356.","journal-title":"Int J Metalcast"},{"issue":"1","key":"1001_CR7","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/s12560-010-9025-6","volume":"2","author":"P Vasickova","year":"2010","unstructured":"Vasickova P, Pavlik I, Verani M, Carducci A. Issues concerning survival of viruses on surfaces. Food Environ Virol. 2010;2(1):24\u201334.","journal-title":"Food Environ Virol"},{"issue":"4","key":"1001_CR8","doi-asserted-by":"publisher","first-page":"e95865","DOI":"10.1371\/journal.pone.0095865","volume":"9","author":"H-L Hong","year":"2014","unstructured":"Hong H-L, Hong S-B, Ko G-B, Huh JW, Sung H, Do K-H, Kim S-H, Lee S-O, Kim M-N, Jeong J-Y, Lim C-M, Kim YS, Woo JH, Koh Y, Choi S-H. Viral infection is not uncommon in adult patients with severe hospital-acquired pneumonia. PLoS ONE. 2014;9(4):e95865.","journal-title":"PLoS ONE"},{"issue":"1","key":"1001_CR9","doi-asserted-by":"publisher","first-page":"ofx006","DOI":"10.1093\/ofid\/ofx006","volume":"4","author":"EJ Chow","year":"2017","unstructured":"Chow EJ, Mermel LA (2017) Hospital-Acquired Respiratory Viral Infections: Incidence, Morbidity, and Mortality in Pediatric and Adult Patients. Open Forum. Infect Dis. 4(1):ofx006. https:\/\/doi.org\/10.1093\/ofid\/ofx006.","journal-title":"Infect Dis."},{"issue":"1","key":"1001_CR10","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jhin.2004.04.021","volume":"58","author":"J Barker","year":"2004","unstructured":"Barker J, Vipond I, Bloomfield S. Effects of cleaning and disinfection in reducing the spread of Norovirus contamination via environmental surfaces. J Hosp Infect. 2004;58(1):42\u20139.","journal-title":"J Hosp Infect"},{"key":"1001_CR11","unstructured":"EPA. Updated draft protocol for the evaluation of bactericidal activity of hard, nonporous copper containing surface products. 2016b. https:\/\/www.epa.gov\/pesticide-registration\/updated-draft-protocol-evaluation-bactericidal-activity-hard-non-porous; https:\/\/www.epa.gov\/sites\/default\/files\/2016-02\/documents\/copper_and_copperalloy_surface_protocol_revised_012916.pdf."},{"issue":"9","key":"1001_CR12","doi-asserted-by":"publisher","first-page":"736","DOI":"10.3390\/ma9090736","volume":"9","author":"V Villapun","year":"2016","unstructured":"Villapun V, Dover L, Cross A, Gonzalez S. Antibacterial metallic touch surfaces. Materials. 2016;9(9):736.","journal-title":"Materials"},{"issue":"1","key":"1001_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12866-016-0675-x","volume":"16","author":"J Hodek","year":"2016","unstructured":"Hodek J, Zajicova V, Lovetinska-Slamborova I, Stibor I, Mullerova J, Weber J. Protective hybrid coating containing silver, copper and zinc cations effective against human immunodeficiency virus and other enveloped viruses. BMC Microbiol. 2016;16(1):1\u201312.","journal-title":"BMC Microbiol"},{"key":"1001_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2020.02.008","author":"S-D Walji","year":"2020","unstructured":"Walji S-D, Aucoin MG. A critical evaluation of current protocols for self-sterilizing surfaces designed to reduce viral nosocomial infections. Am J Infect Control. 2020. https:\/\/doi.org\/10.1016\/j.ajic.2020.02.008.","journal-title":"Am J Infect Control"},{"key":"1001_CR15","doi-asserted-by":"publisher","first-page":"S15","DOI":"10.1016\/S0195-6701(01)90006-4","volume":"48","author":"J Steinmann","year":"2001","unstructured":"Steinmann J. Some principles of virucidal testing. J Hosp Infect. 2001;48:S15\u20137.","journal-title":"J Hosp Infect"},{"issue":"11","key":"1001_CR16","doi-asserted-by":"publisher","first-page":"e81295","DOI":"10.1371\/journal.pone.0081295","volume":"8","author":"Z Han","year":"2013","unstructured":"Han Z, Jin L, Platisa J, Cohen LB, Baker BJ, Pieribone VA. Fluorescent protein voltage probes derived from ArcLight that respond to membrane voltage changes with fast kinetics. PLoS ONE. 2013;8(11):e81295.","journal-title":"PLoS ONE"},{"issue":"3","key":"1001_CR17","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1093\/oxfordjournals.aje.a118408","volume":"27","author":"LJ Reed","year":"1983","unstructured":"Reed LJ, Muench H. A simple method of estimating fifty percent endpoints. Am J Epidemiol. 1983;27(3):493\u20137.","journal-title":"Am J Epidemiol"},{"key":"1001_CR18","unstructured":"EPA. Questions on copper surface efficacy protocol. 2016a. https:\/\/www.epa.gov\/sites\/default\/files\/2016-02\/documents\/questions-copper-surface-efficacy-protocol.pdf."},{"issue":"9","key":"1001_CR19","doi-asserted-by":"publisher","first-page":"2712","DOI":"10.1128\/AEM.02291-09","volume":"76","author":"LM Casanova","year":"2010","unstructured":"Casanova LM, Jeon S, Rutala WA, Weber DJ, Sobsey MD. Effects of air temperature and relative humidity on coronavirus survival on surfaces. Appl Environ Microbiol. 2010;76(9):2712\u20137.","journal-title":"Appl Environ Microbiol"},{"issue":"6","key":"1001_CR20","doi-asserted-by":"publisher","first-page":"01697","DOI":"10.1128\/mBio.01697-15","volume":"6","author":"SL Warnes","year":"2015","unstructured":"Warnes SL, Little ZR, Keevil CW. Human coronavirus 229e remains infectious on common touch surface materials. mBio. 2015;6(6):01697.","journal-title":"mBio"},{"issue":"3","key":"1001_CR21","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1128\/AEM.03280-14","volume":"81","author":"S Warnes","year":"2015","unstructured":"Warnes S, Summersgill E, Keevil C. Inactivation of murine norovirus on a range of copper alloy surfaces is accompanied by loss of capsid integrity. Appl Environ Microbiol. 2015;81(3):1085\u201391.","journal-title":"Appl Environ Microbiol"},{"key":"1001_CR22","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.coviro.2018.01.001","volume":"28","author":"JS Kutter","year":"2018","unstructured":"Kutter JS, Spronken MI, Fraaij PL, Fouchier RA, Herfst S. Transmission routes of respiratory viruses among humans. Curr Opin Virol. 2018;28:142\u201351.","journal-title":"Curr Opin Virol"},{"issue":"1","key":"1001_CR23","first-page":"64","volume":"9","author":"HT Michels","year":"2015","unstructured":"Michels HT, Keevil CW, Salgado CD, Schmidt MG. From Laboratory Research to a Clinical Trial: Copper Alloy Surfaces Kill Bacteria and Reduce Hospital-Acquired Infections. Health Environ Res Des J: HERD. 2015;9(1):64\u201379.","journal-title":"Health Environ Res Des J: HERD"},{"issue":"3","key":"1001_CR24","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.jhin.2005.12.008","volume":"63","author":"J Noyce","year":"2006","unstructured":"Noyce J, Michels H, Keevil C. Potential use of copper surfaces to reduce survival of epidemic meticillin-resistant Staphylococcus aureus in the healthcare environment. J Hosp Infect. 2006;63(3):289\u201397.","journal-title":"J Hosp Infect"},{"issue":"8","key":"1001_CR25","doi-asserted-by":"publisher","first-page":"2748","DOI":"10.1128\/AEM.01139-06","volume":"73","author":"JO Noyce","year":"2007","unstructured":"Noyce JO, Michels H, Keevil CW. Inactivation of influenza A virus on copper versus stainless steel surfaces. Appl Environ Microbiol. 2007;73(8):2748\u201350.","journal-title":"Appl Environ Microbiol"},{"issue":"15","key":"1001_CR26","doi-asserted-by":"publisher","first-page":"4940","DOI":"10.1128\/AEM.00388-15","volume":"81","author":"CS Manuel","year":"2015","unstructured":"Manuel CS, Moore MD, Jaykus LA. Destruction of the capsid and genome of GII.4 human norovirus occurs during exposure to metal alloys containing copper. Appl Environ Microbiol. 2015;81(15):4940\u20136.","journal-title":"Appl Environ Microbiol"},{"issue":"9","key":"1001_CR27","doi-asserted-by":"publisher","first-page":"e75017","DOI":"10.1371\/journal.pone.0075017","volume":"8","author":"SL Warnes","year":"2013","unstructured":"Warnes SL, Keevil CW. Inactivation of norovirus on dry copper alloy surfaces. PLoS ONE. 2013;8(9):e75017.","journal-title":"PLoS ONE"},{"issue":"12","key":"1001_CR28","doi-asserted-by":"publisher","first-page":"4099","DOI":"10.1128\/AEM.00424-10","volume":"76","author":"C Molteni","year":"2010","unstructured":"Molteni C, Abicht HK, Solioz M. Killing of bacteria by copper surfaces involves dissolved copper. Appl Environ Microbiol. 2010;76(12):4099\u2013101.","journal-title":"Appl Environ Microbiol"},{"issue":"1","key":"1001_CR29","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1002\/mbo3.2","volume":"1","author":"CE Santo","year":"2012","unstructured":"Santo CE, Quaranta D, Grass G. Antimicrobial metallic copper surfaces kill Staphylococcus haemolyticus via membrane damage: metallic copper causes membrane damage. MicrobiologyOpen. 2012;1(1):46\u201352.","journal-title":"MicrobiologyOpen"},{"issue":"5","key":"1001_CR30","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1093\/infdis\/jiy221","volume":"218","author":"KA Kormuth","year":"2018","unstructured":"Kormuth KA, Lin K, Prussin AJ, Vejerano EP, Tiwari AJ, Cox SS, Myerburg MM, Lakdawala SS, Marr LC. Influenza virus infectivity is retained in aerosols and droplets independent of relative humidity. J Infect Dis. 2018;218(5):739\u201347.","journal-title":"J Infect Dis"},{"issue":"3","key":"1001_CR31","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1017\/ice.2017.301","volume":"39","author":"J Boyce","year":"2018","unstructured":"Boyce J. Alcohols as surface disinfectants in healthcare settings. Infect Control Hosp Epidemiol. 2018;39(3):323\u20138.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"3","key":"1001_CR32","doi-asserted-by":"publisher","first-page":"e0118207","DOI":"10.1371\/journal.pone.0118207","volume":"10","author":"T Ramos","year":"2015","unstructured":"Ramos T, Dedesko S, Siegel JA, Gilbert JA, Stephens B. Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building. PLoS ONE. 2015;10(3):e0118207.","journal-title":"PLoS ONE"},{"issue":"3","key":"1001_CR33","first-page":"508","volume":"16","author":"DL Jarvis","year":"1994","unstructured":"Jarvis DL, Garcia A. Long-term stability of baculoviruses stored under various conditions. Biotechniques. 1994;16(3):508\u201313.","journal-title":"Biotechniques"}],"container-title":["Antimicrobial Resistance &amp; Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-021-01001-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13756-021-01001-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-021-01001-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,10]],"date-time":"2021-09-10T10:08:37Z","timestamp":1631268517000},"score":1,"resource":{"primary":{"URL":"https:\/\/aricjournal.biomedcentral.com\/articles\/10.1186\/s13756-021-01001-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,10]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1001"],"URL":"https:\/\/doi.org\/10.1186\/s13756-021-01001-x","relation":{},"ISSN":["2047-2994"],"issn-type":[{"value":"2047-2994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,10]]},"assertion":[{"value":"12 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval was not needed for this work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All\u00a0authors consent to have the content of this manuscript published.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interest or conflict of interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"133"}}