{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T16:49:04Z","timestamp":1781887744870,"version":"3.54.5"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T00:00:00Z","timestamp":1688428800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T00:00:00Z","timestamp":1688428800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Hamburg-Eppendorf (UKE)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Antimicrob Resist Infect Control"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Admission to a room previously occupied by patients carrying environmentally robust pathogens implies an increased risk of acquiring those pathogens. Therefore, \u2018No-touch\u2019 automated room disinfection systems, including devices based on UV-C irradiation, are discussed to improve terminal cleaning. It is still unclear if clinical isolates of relevant pathogens behave differently under UV-C irradiation compared to laboratory strains used in the approval process of disinfection procedures. In this study we analysed the susceptibility of well characterized clonally divergent vancomycin-resistant enterococci (VRE) strains, including a linezolid-resistant isolate, against UV-C radiation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Susceptibility against UV-C of ten clonally divergent clinical isolates of VRE was determined in comparison to the commonly used test organism <jats:italic>Enterococcus hirae<\/jats:italic> ATCC 10541. Ceramic tiles contaminated with 10<jats:sup>5<\/jats:sup> to 10<jats:sup>6<\/jats:sup> colony forming units\/25\u00a0cm\u00b2 of the different enterococci were positioned at a distance of 1.0 and 1.5\u00a0m and irradiated for 20\u00a0s, resulting in a UV-C dose of 50 and 22\u00a0mJ\/cm\u00b2, respectively. Reduction factors were calculated after quantitative culture of the bacteria recovered from treated and untreated surfaces.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Susceptibility to UV-C varied considerably among the strains studied, with the mean value of the most robust strain being up to a power of ten lower compared to the most sensitive strain at both UV-C doses. The two most tolerant strains belonged to MLST sequence types ST80 and ST1283. The susceptibility of the laboratory strain <jats:italic>E. hirae<\/jats:italic> ATCC 10541 ranged between the most sensitive and most tolerant isolates for both irradiation doses. However, for UV-C dose of 22\u00a0mJ\/cm\u00b2, the reduction of the most tolerant isolate of ST1283 was statistically significantly lower compared to <jats:italic>E. hirae<\/jats:italic> ATCC 10541. The most susceptible strains belonged to the MLST sequence types ST117 and ST203.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>These results indicate that UV-C doses reported in the literature are sufficient for the reduction of commonly used reference strains of enterococci but could be insufficient for the reduction of tolerant patient VRE-isolates in a hospital setting. Therefore, for future studies, the most tolerant clinical isolates should be used to validate automated UV-C devices or longer exposure times should be expected to ensure efficacy in the real world.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13756-023-01259-3","type":"journal-article","created":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T12:06:40Z","timestamp":1688472400000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Tolerance of clinical vancomycin-resistant Enterococcus faecium isolates against UV-C light from a mobile source"],"prefix":"10.1186","volume":"12","author":[{"given":"B.","family":"Knobling","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Franke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Belmar Campos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"B\u00fcttner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Christner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. M.","family":"Klupp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. M.","family":"Maurer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. K.","family":"Knobloch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,4]]},"reference":[{"key":"1259_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms9020343","author":"JE Wi\u00dfmann","year":"2021","unstructured":"Wi\u00dfmann JE, Kirchhoff L, Br\u00fcggemann Y, Todt D, Steinmann J, Steinmann E. Persistence of pathogens on Inanimate Surfaces: a narrative review. Microorganisms. 2021. https:\/\/doi.org\/10.3390\/microorganisms9020343.","journal-title":"Microorganisms"},{"key":"1259_CR2","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/978-3-319-08057-4_2","volume-title":"Use of Biocidal Surfaces for reduction of Healthcare Acquired Infections","author":"A Kramer","year":"2014","unstructured":"Kramer A, Assadian O. Survival of microorganisms on Inanimate Surfaces. In: Borkow G, editor. Use of Biocidal Surfaces for reduction of Healthcare Acquired Infections. Cham: Springer International Publishing; 2014. pp. 7\u201326. https:\/\/doi.org\/10.1007\/978-3-319-08057-4_2."},{"key":"1259_CR3","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/j.jhin.2015.08.005","volume":"91","author":"BG Mitchell","year":"2015","unstructured":"Mitchell BG, Dancer SJ, Anderson M, Dehn E. Risk of organism acquisition from prior room occupants: a systematic review and meta-analysis. J Hosp Infect. 2015;91:211\u20137. https:\/\/doi.org\/10.1016\/j.jhin.2015.08.005.","journal-title":"J Hosp Infect"},{"key":"1259_CR4","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.ajic.2013.01.003","volume":"41","author":"P Carling","year":"2013","unstructured":"Carling P. Methods for assessing the adequacy of practice and improving room disinfection. Am J Infect Control. 2013;41:20\u20135. https:\/\/doi.org\/10.1016\/j.ajic.2013.01.003.","journal-title":"Am J Infect Control"},{"key":"1259_CR5","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jhin.2013.01.008","volume":"84","author":"G FitzGerald","year":"2013","unstructured":"FitzGerald G, Moore G, Wilson APR. Hand hygiene after touching a patient\u2019s surroundings: the opportunities most commonly missed. J Hosp Infect. 2013;84:27\u201331. https:\/\/doi.org\/10.1016\/j.jhin.2013.01.008.","journal-title":"J Hosp Infect"},{"key":"1259_CR6","doi-asserted-by":"publisher","first-page":"ofab008","DOI":"10.1093\/ofid\/ofab008","volume":"8","author":"H Kanamori","year":"2021","unstructured":"Kanamori H, Rutala WA, Gergen MF, Sickbert-Bennett EE, Knelson LP, Anderson DJ, et al. Microbial Assessment of Health Care-Associated Pathogens on various environmental Sites in patient rooms after terminal room disinfection. Open Forum Infect Dis. 2021;8:ofab008. https:\/\/doi.org\/10.1093\/ofid\/ofab008.","journal-title":"Open Forum Infect Dis"},{"key":"1259_CR7","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1086\/670215","volume":"34","author":"DJ Anderson","year":"2013","unstructured":"Anderson DJ, Gergen MF, Smathers E, Sexton DJ, Chen LF, Weber DJ, Rutala WA. Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device. Infect Control Hosp Epidemiol. 2013;34:466\u201371. https:\/\/doi.org\/10.1086\/670215.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1259_CR8","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1186\/s13756-021-00945-4","volume":"10","author":"F Astrid","year":"2021","unstructured":"Astrid F, Beata Z, van den Nest M, Julia E, Elisabeth P, Magda D-E. The use of a UV-C disinfection robot in the routine cleaning process: a field study in an academic hospital. Antimicrob Resist Infect Control. 2021;10:84. https:\/\/doi.org\/10.1186\/s13756-021-00945-4.","journal-title":"Antimicrob Resist Infect Control"},{"key":"1259_CR9","doi-asserted-by":"publisher","unstructured":"Otter JA, Yezli S, Barbut F, Perl TM. An overview of automated room disinfection systems: When to use them and how to choose them. In: Decontamination in Hospitals and Healthcare: Elsevier; 2020. p.\u00a0323\u2013369. doi:https:\/\/doi.org\/10.1016\/B978-0-08-102565-9.00015-7.","DOI":"10.1016\/B978-0-08-102565-9.00015-7"},{"key":"1259_CR10","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/S0140-6736(00)02509-5","volume":"356","author":"I Reiss","year":"2000","unstructured":"Reiss I, Borkhardt A, F\u00fcssle R, Sziegoleit A, Gortner L. Disinfectant contaminated with Klebsiella oxytoca as a source of sepsis in babies. The Lancet. 2000;356:310. https:\/\/doi.org\/10.1016\/S0140-6736(00)02509-5.","journal-title":"The Lancet"},{"key":"1259_CR11","doi-asserted-by":"publisher","first-page":"618263","DOI":"10.3389\/fpubh.2021.618263","volume":"9","author":"B Knobling","year":"2021","unstructured":"Knobling B, Franke G, Klupp EM, Belmar Campos C, Knobloch JK. Evaluation of the effectiveness of two automated Room Decontamination Devices under Real-Life conditions. Front Public Health. 2021;9:618263. https:\/\/doi.org\/10.3389\/fpubh.2021.618263.","journal-title":"Front Public Health"},{"key":"1259_CR12","doi-asserted-by":"publisher","DOI":"10.3390\/ma14051075","author":"N Bono","year":"2021","unstructured":"Bono N, Ponti F, Punta C, Candiani G. Effect of UV irradiation and TiO2-Photocatalysis on Airborne Bacteria and viruses: an overview. Mater (Basel). 2021. https:\/\/doi.org\/10.3390\/ma14051075.","journal-title":"Mater (Basel)"},{"key":"1259_CR13","doi-asserted-by":"publisher","DOI":"10.6028\/jres.126.021","author":"M Masjoudi","year":"2021","unstructured":"Masjoudi M, Mohseni M, Bolton JR. Sensitivity of Bacteria, Protozoa, Viruses, and other microorganisms to Ultraviolet Radiation. J RES NATL INST STAN. 2021. https:\/\/doi.org\/10.6028\/jres.126.021.","journal-title":"J RES NATL INST STAN"},{"key":"1259_CR14","doi-asserted-by":"publisher","first-page":"13393","DOI":"10.1021\/es303652q","volume":"46","author":"CW McKinney","year":"2012","unstructured":"McKinney CW, Pruden A. Ultraviolet disinfection of antibiotic resistant bacteria and their antibiotic resistance genes in water and wastewater. Environ Sci Technol. 2012;46:13393\u2013400. https:\/\/doi.org\/10.1021\/es303652q.","journal-title":"Environ Sci Technol"},{"key":"1259_CR15","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1186\/1471-2334-10-197","volume":"10","author":"MM Nerandzic","year":"2010","unstructured":"Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis. 2010;10:197. https:\/\/doi.org\/10.1186\/1471-2334-10-197.","journal-title":"BMC Infect Dis"},{"key":"1259_CR16","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1017\/ice.2016.35","volume":"37","author":"JM Boyce","year":"2016","unstructured":"Boyce JM, Farrel PA, Towle D, Fekieta R, Aniskiewicz M. Impact of Room Location on UV-C irradiance and UV-C dosage and Antimicrobial Effect delivered by a Mobile UV-C light device. Infect Control Hosp Epidemiol. 2016;37:667\u201372. https:\/\/doi.org\/10.1017\/ice.2016.35.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1259_CR17","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1080\/15459624.2016.1166369","volume":"13","author":"KC Jelden","year":"2016","unstructured":"Jelden KC, Gibbs SG, Smith PW, Hewlett AL, Iwen PC, Schmid KK, Lowe JJ. Comparison of hospital room surface disinfection using a novel ultraviolet germicidal irradiation (UVGI) generator. J Occup Environ Hyg. 2016;13:690\u20138. https:\/\/doi.org\/10.1080\/15459624.2016.1166369.","journal-title":"J Occup Environ Hyg"},{"key":"1259_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2022.01.006","author":"AJ Beswick","year":"2022","unstructured":"Beswick AJ, Fry C, Bradley CR, Pottage T, Sharpe S, Haill CF, et al. Automated room decontamination: report of a Healthcare infection Society Working Party. J Hosp Infect. 2022. https:\/\/doi.org\/10.1016\/j.jhin.2022.01.006.","journal-title":"J Hosp Infect"},{"key":"1259_CR19","doi-asserted-by":"publisher","unstructured":"Deutsches Institut f\u00fcr Normung e.V. Chemical disinfectants and antiseptics - application of european Standards for chemical disinfectants and antiseptics; german version EN 14885:2018. Berlin: Beuth Verlag GmbH. doi:https:\/\/doi.org\/10.31030\/3085857.","DOI":"10.31030\/3085857"},{"key":"1259_CR20","doi-asserted-by":"publisher","first-page":"3788","DOI":"10.1128\/JCM.01946-15","volume":"53","author":"M de Been","year":"2015","unstructured":"de Been M, Pinholt M, Top J, Bletz S, Mellmann A, van Schaik W, et al. Core Genome Multilocus sequence typing Scheme for High- Resolution typing of Enterococcus faecium. J Clin Microbiol. 2015;53:3788\u201397. https:\/\/doi.org\/10.1128\/JCM.01946-15.","journal-title":"J Clin Microbiol"},{"key":"1259_CR21","doi-asserted-by":"publisher","first-page":"3491","DOI":"10.1093\/jac\/dkaa345","volume":"75","author":"V Bortolaia","year":"2020","unstructured":"Bortolaia V, Kaas RS, Ruppe E, Roberts MC, Schwarz S, Cattoir V, et al. ResFinder 4.0 for predictions of phenotypes from genotypes. J Antimicrob Chemother. 2020;75:3491\u2013500. https:\/\/doi.org\/10.1093\/jac\/dkaa345.","journal-title":"J Antimicrob Chemother"},{"key":"1259_CR22","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1186\/s12859-018-2336-6","volume":"19","author":"PTLC Clausen","year":"2018","unstructured":"Clausen PTLC, Aarestrup FM, Lund O. Rapid and precise alignment of raw reads against redundant databases with KMA. BMC Bioinformatics. 2018;19:307. https:\/\/doi.org\/10.1186\/s12859-018-2336-6.","journal-title":"BMC Bioinformatics"},{"key":"1259_CR23","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1093\/jac\/dkz092","volume":"74","author":"H Hasman","year":"2019","unstructured":"Hasman H, Clausen PTLC, Kaya H, Hansen F, Knudsen JD, Wang M, et al. LRE-Finder, a web tool for detection of the 23S rRNA mutations and the optrA, cfr, cfr(B) and poxtA genes encoding linezolid resistance in enterococci from whole-genome sequences. J Antimicrob Chemother. 2019;74:1473\u20136. https:\/\/doi.org\/10.1093\/jac\/dkz092.","journal-title":"J Antimicrob Chemother"},{"key":"1259_CR24","doi-asserted-by":"publisher","unstructured":"Deutsches Institut f\u00fcr Normung e.V. Chemical disinfectants and antiseptics - methods of airborne room disinfection by automated process - determination of bactericidal, mycobactericidal, sporicidal, fungicidal, yeasticidal, virucidal and phagocidal activities; german version EN 17272:2020. Berlin: Beuth Verlag GmbH. doi:https:\/\/doi.org\/10.31030\/3071835.","DOI":"10.31030\/3071835"},{"key":"1259_CR25","volume-title":"R: a Language and Environment for Statistical Computing","author":"R Core Team","year":"2020","unstructured":"R Core Team. R: a Language and Environment for Statistical Computing. Vienna, Austria: R Foundation for Statistical Computing; 2020."},{"key":"1259_CR26","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.21105\/joss.01686","volume":"4","author":"H Wickham","year":"2019","unstructured":"Wickham H, Averick M, Bryan J, Chang W, McGowan L, Fran\u00e7ois R, et al. Welcome to the Tidyverse JOSS. 2019;4:1686. https:\/\/doi.org\/10.21105\/joss.01686.","journal-title":"Welcome to the Tidyverse JOSS"},{"key":"1259_CR27","unstructured":"Alboukadel Kassambara. ggpubr: \u2018ggplot2\u2019. Based Publication Ready Plots; 2020."},{"key":"1259_CR28","unstructured":"Alboukadel Kassambara. rstatix: Pipe-Friendly Framework for Basic Statistical Tests; 2021."},{"key":"1259_CR29","volume-title":"Psych: procedures for psychological, psychometric, and Personality Research","author":"William Revelle","year":"2021","unstructured":"William Revelle. Psych: procedures for psychological, psychometric, and Personality Research. Evanston, Illinois: Northwestern University; 2021."},{"key":"1259_CR30","volume-title":"An R companion to Applied Regression","author":"John Fox and Sanford Weisberg","year":"2019","unstructured":"John Fox and Sanford Weisberg. An R companion to Applied Regression. Thousand Oaks CA: Sage; 2019."},{"key":"1259_CR31","unstructured":"UVD Robots\u00ae ApS. The UVD Robots Guide for healthcare associated pathogens. Odense, Denmark; 04.2021."},{"key":"1259_CR32","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jhin.2013.05.005","volume":"84","author":"N Mahida","year":"2013","unstructured":"Mahida N, Vaughan N, Boswell T. First UK evaluation of an automated ultraviolet-C room decontamination device (Tru-D\u2122). J Hosp Infect. 2013;84:332\u20135. https:\/\/doi.org\/10.1016\/j.jhin.2013.05.005.","journal-title":"J Hosp Infect"},{"key":"1259_CR33","doi-asserted-by":"publisher","first-page":"1426","DOI":"10.1017\/ice.2016.198","volume":"37","author":"AM Shams","year":"2016","unstructured":"Shams AM, Rose LJ, Edwards JR, Cali S, Harris AD, Jacob JT, et al. Assessment of the overall and multidrug-resistant organism Bioburden on Environmental Surfaces in Healthcare Facilities. Infect Control Hosp Epidemiol. 2016;37:1426\u201332. https:\/\/doi.org\/10.1017\/ice.2016.198.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1259_CR34","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1186\/s13756-021-00981-0","volume":"10","author":"A van Arkel","year":"2021","unstructured":"van Arkel A, Willemsen I, Kluytmans J. The correlation between ATP measurement and microbial contamination of inanimate surfaces. Antimicrob Resist Infect Control. 2021;10:116. https:\/\/doi.org\/10.1186\/s13756-021-00981-0.","journal-title":"Antimicrob Resist Infect Control"}],"container-title":["Antimicrobial Resistance &amp; Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-023-01259-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13756-023-01259-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-023-01259-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T12:12:18Z","timestamp":1688472738000},"score":1,"resource":{"primary":{"URL":"https:\/\/aricjournal.biomedcentral.com\/articles\/10.1186\/s13756-023-01259-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,4]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1259"],"URL":"https:\/\/doi.org\/10.1186\/s13756-023-01259-3","relation":{},"ISSN":["2047-2994"],"issn-type":[{"value":"2047-2994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,4]]},"assertion":[{"value":"29 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"63"}}