{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T01:39:11Z","timestamp":1773452351364,"version":"3.50.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T00:00:00Z","timestamp":1753488000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T00:00:00Z","timestamp":1753488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003625","name":"Ministry of Health and Welfare","doi-asserted-by":"publisher","award":["HG22C0069"],"award-info":[{"award-number":["HG22C0069"]}],"id":[{"id":"10.13039\/501100003625","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Antimicrob Resist Infect Control"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>This study evaluates the efficacy of dry-fogged hydrogen peroxide (dHP) as an \u201cuntact\u201d room disinfection automation system (URDAS) for rapid terminal room decontamination.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This prospective study was conducted at a university-affiliated hospital in Korea. After patient discharge, dHP technology was used to decontaminate single rooms. Environmental cultures were collected from inanimate surfaces and room air before and after the decontamination process. Routine manual cleaning and disinfection were performed only after environmental sampling during terminal decontamination.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>After applying URDAS using dHP, culture positivity in the surface samples decreased from 20.5% (16\/78) to 5.1% (4\/78). Particularly, bed-removable tables and bedsheets used by patients often remain contaminated even after disinfection. Thirty-six species were isolated from the air cultures before disinfection, which decreased to 23 species after disinfection, representing a 36.1% reduction. The most frequently isolated pathogens after disinfection were <jats:italic>S. aureus<\/jats:italic> on fabric materials from surface samples and <jats:italic>Aspergillus<\/jats:italic> species from air samples.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Our findings demonstrate that URDAS using dHP is an effective tool for disinfecting contaminated environmental surfaces and spaces in single isolation rooms with minimal risk of exposure to medical staff. However, further optimization is required to address the material- and pathogen-specific disinfection challenges.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s13756-025-01613-7","type":"journal-article","created":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T13:00:52Z","timestamp":1753534852000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Assessment of dry-fogged hydrogen peroxide as an \u201cuntact\u201d room disinfection automation system for rapid terminal decontamination of a single isolation room in a healthcare institution"],"prefix":"10.1186","volume":"14","author":[{"given":"Jin Woong","family":"Suh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeong Yeon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang Wook","family":"Sohn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung Eun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyeon Jeong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Woo Jin","family":"Chi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mi Na","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Kyung","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,26]]},"reference":[{"issue":"5","key":"1613_CR1","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.1016\/j.ajic.2012.12.004","volume":"41","author":"JA Otter","year":"2013","unstructured":"Otter JA, Yezli S, Salkeld JA, French GL. Evidence that contaminated surfaces contribute to the transmission of hospital pathogens and an overview of strategies to address contaminated surfaces in hospital settings. Am J Infect Control. 2013;41(5):S6\u201311.","journal-title":"Am J Infect Control"},{"key":"1613_CR2","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1097\/QCO.0b013e3283630f04","volume":"26","author":"DJ Weber","year":"2013","unstructured":"Weber DJ, Anderson D, Rutala WA. The role of the surface environment in healthcare-associated infections. Curr Opin Infect Dis. 2013;26:338\u201344.","journal-title":"Curr Opin Infect Dis"},{"key":"1613_CR3","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1186\/1471-2334-6-130","volume":"6","author":"A Kramer","year":"2006","unstructured":"Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect Dis. 2006;6:130.","journal-title":"BMC Infect Dis"},{"key":"1613_CR4","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1086\/591940","volume":"29","author":"PC Carling","year":"2008","unstructured":"Carling PC, Parry MM, Rupp ME, Po JL, Dick B, Von Beheren S, et al. Improving cleaning of the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol. 2008;29:1035\u201341.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1613_CR5","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1097\/CCM.0b013e3181cdf705","volume":"38","author":"PC Carling","year":"2010","unstructured":"Carling PC, Parry MF, Bruno-Murtha LA, Dick B. Improving environmental hygiene in 27 intensive care units to decrease multidrug-resistant bacterial transmission. Crit Care Med. 2010;38:1054\u20139.","journal-title":"Crit Care Med"},{"issue":"4","key":"1613_CR6","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1097\/QCO.0000000000000284","volume":"29","author":"DJ Weber","year":"2016","unstructured":"Weber DJ, Kanamori H, Rutala WA. No touch technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems. Curr Opin Infect Dis. 2016;29(4):424\u201331.","journal-title":"Curr Opin Infect Dis"},{"issue":"2","key":"1613_CR7","first-page":"352","volume":"14","author":"MOA Mohammed","year":"2023","unstructured":"Mohammed MOA. Surface microbial contamination and air quality before and after regular cleaning procedures. Atmos (Basel). 2023;14(2):352.","journal-title":"Atmos (Basel)"},{"issue":"1","key":"1613_CR8","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1053\/jhin.1998.0542","volume":"42","author":"B Friberg","year":"1999","unstructured":"Friberg B, Friberg S, Burman LG. Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental study. J Hosp Infect. 1999;42(1):61\u20138.","journal-title":"J Hosp Infect"},{"issue":"6","key":"1613_CR9","doi-asserted-by":"publisher","first-page":"703","DOI":"10.30802\/AALAS-JAALAS-19-000165","volume":"59","author":"T Kimura","year":"2020","unstructured":"Kimura T, Yahata H, Uchiyama Y. Examination of material compatibilities with ionized and vaporized hydrogen peroxide decontamination. J Am Assoc Lab Anim Sci. 2020;59(6):703\u201311.","journal-title":"J Am Assoc Lab Anim Sci"},{"issue":"3","key":"1613_CR10","doi-asserted-by":"publisher","first-page":"205","DOI":"10.3390\/bioengineering11030205","volume":"11","author":"A Ayub","year":"2024","unstructured":"Ayub A, Cheong YK, Castro JC, Cumberlege O, Chrysanthou A. Use of hydrogen peroxide vapour for microbiological disinfection in hospital environments: a review. Bioengineering. 2024;11(3):205.","journal-title":"Bioengineering"},{"key":"1613_CR11","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1086\/655016","volume":"31","author":"K Huslage","year":"2010","unstructured":"Huslage K, Rutala WA, Sickbert-Bennett E, Weber DJ. A quantitative approach to defining high-touch surfaces in hospitals. Infect Control Hosp Epidemiol. 2010;31:850\u20133.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1613_CR12","unstructured":"Centers for Disease Control and Prevention, Infection Control Africa Network. Best practices for environmental cleaning in healthcare facilities in resource-limited settings. https:\/\/www.cdc.gov\/healthcare-associated-infections\/media\/pdfs\/environmental-cleaning-rls-508.pdf; 2019 [accessed February 13, 2025]."},{"issue":"3","key":"1613_CR13","first-page":"138","volume":"33","author":"J Chai","year":"2018","unstructured":"Chai J, Donnelly T, Wong T, Bryce E. Environmental sampling of hospital surfaces: assessing methodological quality. Can J Infect Control. 2018;33(3):138\u201345.","journal-title":"Can J Infect Control"},{"key":"1613_CR14","unstructured":"CLSI. Performance standards for antimicrobial susceptibility testing; twenty-fifth informational supplement. CLSI document m100-S25. Wayne, Pennsylvania: Clinical and Laboratory Standards Institute. 2015;32:1\u2013184."},{"issue":"Suppl 2","key":"1613_CR15","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/S0195-6701(07)60015-2","volume":"65","author":"JM Boyce","year":"2007","unstructured":"Boyce JM. Environmental contamination makes an important contribution to hospital infection. J Hosp Infect. 2007;65(Suppl 2):50\u20134.","journal-title":"J Hosp Infect"},{"key":"1613_CR16","doi-asserted-by":"publisher","first-page":"3236526","DOI":"10.1155\/2019\/3236526","volume":"2019","author":"L Chaoui","year":"2019","unstructured":"Chaoui L, Mhand R, Mellouki F, Rhallabi N. Contamination of the surfaces of a health care environment by multidrug-resistant (MDR) bacteria. Int J Microbiol. 2019;2019:3236526.","journal-title":"Int J Microbiol"},{"key":"1613_CR17","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1053\/apmr.2002.32733","volume":"83","author":"WE Trick","year":"2002","unstructured":"Trick WE, Temple RS, Chen D, Wright MO, Solomon SL, Peterson LR. Patient colonization and environmental contamination by vancomycin-resistant enterococci in a rehabilitation facility. Arch Phys Med Rehabil. 2002;83:899\u2013902.","journal-title":"Arch Phys Med Rehabil"},{"key":"1613_CR18","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1001\/jama.287.11.1395","volume":"287","author":"AJ Ray","year":"2002","unstructured":"Ray AJ, Hoyen CK, Taub TF, Eckstein EC, Donskey CJ. Nosocomial transmission of vancomycin-resistant enterococci from surfaces. JAMA. 2002;287:1400\u20131.","journal-title":"JAMA"},{"key":"1613_CR19","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.jiph.2022.01.002","volume":"15","author":"SH Kim","year":"2022","unstructured":"Kim SH, Kim GR, Kim EY, Jeong J, Kim S, Shin JH. Carbapenemase-producing eenterobacterales from hospital environment and their relation to those from patient specimens. J Infect Public Health. 2022;15:241\u20134.","journal-title":"J Infect Public Health"},{"key":"1613_CR20","doi-asserted-by":"publisher","first-page":"e9495","DOI":"10.1016\/j.cmi.2016.08.020","volume":"22","author":"A Nutman","year":"2016","unstructured":"Nutman A, Lerner A, Schwartz D, Carmeli Y. Evaluation of carriage and environmental contamination by carbapenem-resistant acinetobacter baumannii. Clin Microbiol Infect. 2016;22:e9495\u20137.","journal-title":"Clin Microbiol Infect"},{"key":"1613_CR21","doi-asserted-by":"crossref","unstructured":"Russotto V, Cortegiani A, Fasciana T, Iozzo P, Raineri SM, Gregoretti C et al. What healthcare workers should know about environmental bacterial contamination in the intensive care unit. BioMed Res Int. 2017;6905450.","DOI":"10.1155\/2017\/6905450"},{"key":"1613_CR22","doi-asserted-by":"publisher","first-page":"105","DOI":"10.14192\/kjicp.2020.25.2.105","volume":"25","author":"HJ Shi","year":"2020","unstructured":"Shi HJ, Kim JH, Kim NY, Lee JB, Eom JS. Environmental culture of bacteria at the intensive care unit of a tertiary hospital in Korea: a consideration for improving medical environmental safety and healthcare-associated infection. Korean J Healthc Assoc Infect Control Prev. 2020;25:105\u201314.","journal-title":"Korean J Healthc Assoc Infect Control Prev"},{"key":"1613_CR23","doi-asserted-by":"publisher","first-page":"e0261802","DOI":"10.1371\/journal.pone.0261802","volume":"17","author":"M Urushidani","year":"2022","unstructured":"Urushidani M, Kawayoshi A, Kotaki T, Saeki K, Mori Y, Kameoka M. Inactivation of SARS-CoV-2 and influenza A virus by dry fogging hypochlorous acid solution and hydrogen peroxide solution. PLoS ONE. 2022;17:e0261802.","journal-title":"PLoS ONE"},{"key":"1613_CR24","doi-asserted-by":"publisher","first-page":"75338","DOI":"10.1007\/s11356-022-21174-1","volume":"29","author":"G Hesam","year":"2022","unstructured":"Hesam G, Vahabi Shekarloo M, Atamaleki A, Jalali M, Hajipour-Verdom B, Moradpour Z. Health risk assessment of inhalation exposure to dry fogging of hydrogen peroxide in a dental clinic during the COVID-19 pandemic. Environ Sci Pollut Res Int. 2022;29:75338\u201343.","journal-title":"Environ Sci Pollut Res Int"},{"key":"1613_CR25","doi-asserted-by":"publisher","first-page":"185","DOI":"10.26444\/aaem\/144136","volume":"29","author":"A Buk\u0142aha","year":"2022","unstructured":"Buk\u0142aha A, Wieczorek A, Majewski P, Iwaniuk D, Sacha P, Tryniszewska E, et al. New trends in application of the fumigation method in medical and non-medical fields. Ann Agric Environ Med. 2022;29:185\u20139.","journal-title":"Ann Agric Environ Med"},{"key":"1613_CR26","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1017\/ice.2017.226","volume":"39","author":"AR Marra","year":"2018","unstructured":"Marra AR, Schweizer ML, Edmond MB. No-touch disinfection methods to decrease multidrug-resistant organism infections: a systematic review and meta-analysis. Infect Control Hosp Epidemiol. 2018;39:20\u201331.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1613_CR27","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1093\/cid\/cis839","volume":"56","author":"CL Passaretti","year":"2013","unstructured":"Passaretti CL, Otter JA, Reich NG, Myers J, Shepard J, Ross T, et al. An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms. Clin Infect Dis. 2013;56:27\u201335.","journal-title":"Clin Infect Dis"},{"key":"1613_CR28","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1128\/JCM.02004-08","volume":"47","author":"JA Otter","year":"2009","unstructured":"Otter JA, French GL. Survival of nosocomial bacteria and spores on surfaces and inactivation by hydrogen peroxide vapor. J Clin Microbiol. 2009;47:205\u20137.","journal-title":"J Clin Microbiol"},{"key":"1613_CR29","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.jhin.2011.11.001","volume":"80","author":"T Pottage","year":"2012","unstructured":"Pottage T, Macken S, Walker JT, Bennett AM. Meticillin-resistant staphylococcus aureus is more resistant to vaporized hydrogen peroxide than commercial geobacillus stearothermophilus biological indicators. J Hosp Infect. 2012;80:41\u20135.","journal-title":"J Hosp Infect"},{"key":"1613_CR30","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13054-015-0752-9","volume":"19","author":"C Blazejewski","year":"2015","unstructured":"Blazejewski C, Wallet F, Rouz\u00e9 A, Le Guern R, Ponthieux S, Salleron J, et al. Efficiency of hydrogen peroxide in improving disinfection of ICU rooms. Crit Care. 2015;19:30.","journal-title":"Crit Care"},{"key":"1613_CR31","doi-asserted-by":"publisher","first-page":"103850","DOI":"10.1016\/j.fm.2021.103850","volume":"100","author":"V Visconti","year":"2021","unstructured":"Visconti V, Rigalma K, Coton E, Dantigny P. Impact of the physiological state of fungal spores on their inactivation by active chlorine and hydrogen peroxide. Food Microbiol. 2021;100:103850.","journal-title":"Food Microbiol"},{"key":"1613_CR32","doi-asserted-by":"publisher","first-page":"55","DOI":"10.3390\/foods10010055","volume":"10","author":"CF Kure","year":"2020","unstructured":"Kure CF, Langsrud S, M\u00f8retr\u00f8 T. Efficient reduction of food related mould spores on surfaces by hydrogen peroxide mist. Foods. 2020;10:55.","journal-title":"Foods"},{"key":"1613_CR33","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.jhin.2008.06.008","volume":"70","author":"S Shapey","year":"2008","unstructured":"Shapey S, Machin K, Levi K, Boswell TC. Activity of a dry mist hydrogen peroxide system against environmental clostridium difficile contamination in elderly care wards. J Hosp Infect. 2008;70:136\u201341.","journal-title":"J Hosp Infect"},{"key":"1613_CR34","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1016\/j.ajic.2013.11.022","volume":"42","author":"WA Rutala","year":"2014","unstructured":"Rutala WA, Gergen MF, Sickbert-Bennett EE, Williams DA, Weber DJ. Effectiveness of improved hydrogen peroxide in decontaminating privacy curtains contaminated with multidrug-resistant pathogens. Am J Infect Control. 2014;42:426\u20138.","journal-title":"Am J Infect Control"},{"key":"1613_CR35","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.ajic.2014.10.007","volume":"43","author":"S Lemmen","year":"2015","unstructured":"Lemmen S, Scheithauer S, H\u00e4fner H, Yezli S, Mohr M, Otter JA. Evaluation of hydrogen peroxide vapor for the inactivation of nosocomial pathogens on porous and nonporous surfaces. Am J Infect Control. 2015;43:82\u20135.","journal-title":"Am J Infect Control"},{"key":"1613_CR36","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.jhin.2007.07.019","volume":"67","author":"JA Otter","year":"2007","unstructured":"Otter JA, Cummins M, Ahmad F, van Tonder C, Drabu YJ. Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination. J Hosp Infect. 2007;67:182\u20138.","journal-title":"J Hosp Infect"},{"issue":"2","key":"1613_CR37","first-page":"e0340","volume":"3","author":"KA Reynolds","year":"2021","unstructured":"Reynolds KA, Sexton JD, Garavito F, Anderson B, Ivaska JM. Impact of a whole-room atomizing disinfection system on healthcare surface contamination, pathogen transfer, and labor efficiency. Crit Care Explor. 2021;3(2):e0340.","journal-title":"Crit Care Explor"},{"issue":"3","key":"1613_CR38","doi-asserted-by":"publisher","first-page":"100021","DOI":"10.1016\/j.indenv.2024.100021","volume":"1","author":"M T\u00e4ubel","year":"2024","unstructured":"T\u00e4ubel M, Castagnoli E, Salthammer T, Morawska L, Salonen H. The impact of cleaning on the microbiomes of indoor surfaces. Indoor Environ. 2024;1(3):100021.","journal-title":"Indoor Environ"}],"container-title":["Antimicrobial Resistance &amp; Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-025-01613-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13756-025-01613-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-025-01613-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T01:41:43Z","timestamp":1757295703000},"score":1,"resource":{"primary":{"URL":"https:\/\/aricjournal.biomedcentral.com\/articles\/10.1186\/s13756-025-01613-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,26]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1613"],"URL":"https:\/\/doi.org\/10.1186\/s13756-025-01613-7","relation":{},"ISSN":["2047-2994"],"issn-type":[{"value":"2047-2994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,26]]},"assertion":[{"value":"24 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"92"}}