{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T09:38:55Z","timestamp":1789810735961,"version":"4.0.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"vor","delay-in-days":37,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Antimicrob Resist Infect Control"],"DOI":"10.1186\/s13756-025-01669-5","type":"journal-article","created":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T04:26:46Z","timestamp":1764390406000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Is UV-C light disinfection suitable as a disinfection method for medical devices: a scoping review"],"prefix":"10.1186","volume":"15","author":[{"given":"Yana","family":"Halmans","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Wellenstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joost","family":"Hopman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Takes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guido","family":"van den Broek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,29]]},"reference":[{"issue":"46","key":"1669_CR1","doi-asserted-by":"publisher","first-page":"1800516","DOI":"10.2807\/1560-7917.ES.2018.23.46.1800516","volume":"23","author":"C Suetens","year":"2018","unstructured":"Suetens C, Latour K, K\u00e4rki T, Ricchizzi E, Kinross P, Moro ML, et al. Prevalence of healthcare-associated infections, estimated incidence and composite antimicrobial resistance index in acute care hospitals and long-term care facilities: results from two European point prevalence surveys, 2016 to 2017. Eurosurveill. 2018;23(46):1800516.","journal-title":"Eurosurveill"},{"key":"1669_CR2","unstructured":"Scott RD. The direct medical costs of healthcare-associated infections in US hospitals and the benefits of prevention. 2009."},{"key":"1669_CR3","doi-asserted-by":"publisher","first-page":"A79","DOI":"10.1016\/j.ajic.2019.01.015","volume":"47","author":"WA Rutala","year":"2019","unstructured":"Rutala WA, Weber DJ. Reprocessing semicritical items: Outbreaks and current issues. Am J Infect Control. 2019;47:A79\u201389.","journal-title":"Am J Infect Control"},{"issue":"2","key":"1669_CR4","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1128\/CMR.00085-12","volume":"26","author":"J Kovaleva","year":"2013","unstructured":"Kovaleva J, Peters FT, van der Mei HC, Degener JE. Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev. 2013;26(2):231\u201354.","journal-title":"Clin Microbiol Rev"},{"key":"1669_CR5","doi-asserted-by":"publisher","first-page":"587352","DOI":"10.3389\/fmedt.2020.587352","volume":"2","author":"J Josephs-Spaulding","year":"2020","unstructured":"Josephs-Spaulding J, Singh OV. Medical device sterilization and reprocessing in the era of multidrug-resistant (MDR) bacteria: issues and regulatory concepts. Front Med Technol. 2020;2:587352. https:\/\/doi.org\/10.3389\/fmedt.2020.587352.","journal-title":"Front Med Technol"},{"issue":"11","key":"1669_CR6","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.mpaic.2010.08.005","volume":"11","author":"S Veerabadran","year":"2010","unstructured":"Veerabadran S, Parkinson IM. Cleaning, disinfection and sterilization of equipment. Anaesth Intensive Care Med. 2010;11(11):451\u20134.","journal-title":"Anaesth Intensive Care Med"},{"key":"1669_CR7","unstructured":"Center for Disease Control and Prevention (CDC). Guideline for Disinfection and Sterilization in Healthcare Facilities 2008 [Available from: https:\/\/www.cdc.gov\/infectioncontrol\/guidelines\/disinfection\/rational-approach.html."},{"issue":"3","key":"1669_CR8","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/j.idc.2016.04.002","volume":"30","author":"WA Rutala","year":"2016","unstructured":"Rutala WA, Weber DJ. Disinfection and Sterilization in Health Care Facilities: An Overview and Current Issues. Infect Dis Clin North Am. 2016;30(3):609\u201337.","journal-title":"Infect Dis Clin North Am"},{"key":"1669_CR9","doi-asserted-by":"crossref","unstructured":"Recommended practices for high-level disinfection. Aorn j. 2005;81(2):402-12.","DOI":"10.1016\/S0001-2092(06)60423-7"},{"issue":"1","key":"1669_CR10","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1002\/lary.26770","volume":"128","author":"LJ Sowerby","year":"2018","unstructured":"Sowerby LJ, Rudmik L. The cost of being clean: A cost analysis of nasopharyngoscope reprocessing techniques. Laryngoscope. 2018;128(1):64\u201371.","journal-title":"Laryngoscope"},{"issue":"3","key":"1669_CR11","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1308\/003588412X13171221589937","volume":"94","author":"K Tzanidakis","year":"2012","unstructured":"Tzanidakis K, Choudhury N, Bhat S, Weerasinghe A, Marais J. Evaluation of disinfection of flexible nasendoscopes using Tristel wipes: a prospective single blind study. Ann R Coll Surg Engl. 2012;94(3):185\u20138.","journal-title":"Ann R Coll Surg Engl"},{"issue":"1","key":"1669_CR12","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.idc.2010.11.009","volume":"25","author":"WA Rutala","year":"2011","unstructured":"Rutala WA, Weber DJ. Sterilization, high-level disinfection, and environmental cleaning. Infect Dis Clin North Am. 2011;25(1):45\u201376.","journal-title":"Infect Dis Clin North Am"},{"issue":"8","key":"1669_CR13","doi-asserted-by":"publisher","first-page":"2363","DOI":"10.1007\/s00405-020-05978-w","volume":"277","author":"SA Rudhart","year":"2020","unstructured":"Rudhart SA, G\u00fcnther F, Dapper L, Thangavelu K, Gehrt F, Stankovic P, et al. UV light-based decontamination: an effective and fast way for disinfection of endoscopes in otorhinolaryngology? Eur Arch Otorhinolaryngol. 2020;277(8):2363\u20139.","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"1669_CR14","doi-asserted-by":"publisher","first-page":"52","DOI":"10.20411\/pai.v5i1.372","volume":"5","author":"JL Cadnum","year":"2020","unstructured":"Cadnum JL, Li DF, Redmond SN, John AR, Pearlmutter B, Donskey CJ. Effectiveness of ultraviolet-C light and a high-level disinfection cabinet for decontamination of N95 respirators. Pathog Immun. 2020;5(1):52\u201367.","journal-title":"Pathog Immun."},{"issue":"10","key":"1669_CR15","doi-asserted-by":"publisher","first-page":"4075","DOI":"10.1007\/s00405-021-06737-1","volume":"278","author":"SA Rudhart","year":"2021","unstructured":"Rudhart SA, G\u00fcnther F, Dapper L, Thangavelu K, Geisthoff UW, Stankovic P, et al. UV light-based reprocessing of flexible endoscopes without working channel in Oto-Rhino-Laryngology: an effective method? Eur Arch Otorhinolaryngol. 2021;278(10):4075\u201380.","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"1669_CR16","doi-asserted-by":"publisher","first-page":"102161","DOI":"10.1016\/j.pdpdt.2020.102161","volume":"33","author":"T Dos Santos","year":"2021","unstructured":"Dos Santos T, de Castro LF. Evaluation of a portable ultraviolet C (UV-C) device for hospital surface decontamination. Photodiagnosis Photodyn Ther. 2021;33:102161.","journal-title":"Photodiagnosis Photodyn Ther"},{"issue":"1","key":"1669_CR17","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1080\/1364557032000119616","volume":"8","author":"H Arksey","year":"2005","unstructured":"Arksey H, O\u2019Malley L. Scoping studies: towards a methodological framework. Int J Soc Res Methodol. 2005;8(1):19\u201332.","journal-title":"Int J Soc Res Methodol"},{"key":"1669_CR18","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/1748-5908-5-69","volume":"5","author":"D Levac","year":"2010","unstructured":"Levac D, Colquhoun H, O\u2019Brien KK. Scoping studies: advancing the methodology. Implement Sci. 2010;5:69.","journal-title":"Implement Sci"},{"issue":"7","key":"1669_CR19","doi-asserted-by":"publisher","first-page":"467","DOI":"10.7326\/M18-0850","volume":"169","author":"AC Tricco","year":"2018","unstructured":"Tricco AC, Lillie E, Zarin W, O\u2019Brien KK, Colquhoun H, Levac D, et al. PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation. Ann Intern Med. 2018;169(7):467\u201373.","journal-title":"Ann Intern Med"},{"issue":"2","key":"1669_CR20","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jhin.2006.10.008","volume":"65","author":"G Kac","year":"2007","unstructured":"Kac G, Gueneret M, Rodi A, Abergel E, Grataloup C, Denari\u00e9 N, et al. Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet light. J Hosp Infect. 2007;65(2):163\u20138.","journal-title":"J Hosp Infect"},{"issue":"2","key":"1669_CR21","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1086\/649794","volume":"31","author":"G Kac","year":"2010","unstructured":"Kac G, Podglajen I, Si-Mohamed A, Rodi A, Grataloup C, Meyer G. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol. 2010;31(2):165\u201370.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"6","key":"1669_CR22","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1055\/a-0874-1971","volume":"41","author":"J Schmitz","year":"2020","unstructured":"Schmitz J, Kossow A, de Oelmeier Murcia K, Heese S, Braun J, M\u00f6llmann U, et al. Disinfection of transvaginal ultrasound probes by ultraviolet C-a\u00a0clinical evaluation of automated and manual reprocessing methods. Ultraschall med. 2020;41(6):681\u20137.","journal-title":"Ultraschall med"},{"issue":"2","key":"1669_CR23","first-page":"163","volume":"31","author":"GQ Chen","year":"2018","unstructured":"Chen GQ, Chen YH, Yi L, Yin J, Gao Q, Song JN, et al. Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe. Biomed Environ Sci. 2018;31(2):163\u20137.","journal-title":"Biomed Environ Sci"},{"issue":"12","key":"1669_CR24","doi-asserted-by":"publisher","first-page":"3512","DOI":"10.1002\/lary.30869","volume":"133","author":"UC Ezeh","year":"2023","unstructured":"Ezeh UC, Achlatis E, Crosby T, Kwak PE, Phillips MS, Amin MR. The effectiveness of ultraviolet smart D60 in reducing contamination of flexible fiberoptic laryngoscopes. Laryngoscope. 2023;133(12):3512\u20139. https:\/\/doi.org\/10.1002\/lary.30869.","journal-title":"Laryngoscope"},{"key":"1669_CR25","doi-asserted-by":"publisher","DOI":"10.1111\/coa.14119","author":"Y Halmans","year":"2023","unstructured":"Halmans Y, Wellenstein DJ, Romijn M, Cremers S, Smit JJ, Hopman J, et al. Is ultraviolet light disinfection fit to be the future standard for the disinfection of flexible endoscopes without a working channel? Clin Otolaryngol. 2023. https:\/\/doi.org\/10.1111\/coa.14119.","journal-title":"Clin Otolaryngol"},{"key":"1669_CR26","doi-asserted-by":"crossref","unstructured":"Rutala WA, Weber DJ. Disinfection, Sterilization, and Control of Hospital Waste. Mandell Douglas Bennett\u2019s Princ Pract Infect Dis. 2015:3294-309.e4","DOI":"10.1016\/B978-1-4557-4801-3.00301-5"},{"issue":"10","key":"1669_CR27","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1086\/656244","volume":"31","author":"WA Rutala","year":"2010","unstructured":"Rutala WA, Gergen MF, Weber DJ. Room decontamination with UV radiation. Infect Control Hosp Epidemiol. 2010;31(10):1025\u20139.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"8","key":"1669_CR28","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1086\/661222","volume":"32","author":"JM Boyce","year":"2011","unstructured":"Boyce JM, Havill NL, Moore BA. Terminal decontamination of patient rooms using an automated mobile UV light unit. Infect Control Hosp Epidemiol. 2011;32(8):737\u201342.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1669_CR29","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1186\/1471-2334-10-197","volume":"10","author":"MM Nerandzic","year":"2010","unstructured":"Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis. 2010;10:197.","journal-title":"BMC Infect Dis"},{"issue":"4","key":"1669_CR30","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1177\/153567600501000406","volume":"10","author":"MU Owens","year":"2005","unstructured":"Owens MU, Deal DR, Shoemaker MO, Knudson GB, Meszaros JE, Deal JL. High-dose ultraviolet C light inactivates spores of Bacillus atrophaeus and Bacillus anthracis sterne on nonreflective surfaces. Appl Biosaf. 2005;10(4):240\u20137.","journal-title":"Appl Biosaf"},{"issue":"3","key":"1669_CR31","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1582\/LEUKOS.2007.03.03.005","volume":"3","author":"MW First","year":"2007","unstructured":"First MW, Banahan KF, Dumyahn TS. Performance of ultraviolet germicidal irradiation lamps and luminaires in long-term service. Leukos. 2007;3(3):181\u20138.","journal-title":"Leukos"},{"issue":"8","key":"1669_CR32","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.ajic.2006.09.010","volume":"35","author":"LF Muscarella","year":"2007","unstructured":"Muscarella LF. Prevention of disease transmission during flexible laryngoscopy. Am J Infect Control. 2007;35(8):536\u201344. https:\/\/doi.org\/10.1016\/j.ajic.2006.09.010.","journal-title":"Am J Infect Control"},{"key":"1669_CR33","unstructured":"Preventie SWI. Reiniging, desinfectie en sterilisatie in de openbare gezondheidszorg: Documentatiecentrum, Stichting Werkgroep Infectie Preventie, Leids\u00a0\u2026; 2002."},{"issue":"10","key":"1669_CR34","doi-asserted-by":"publisher","first-page":"2349","DOI":"10.1002\/lary.25421","volume":"125","author":"K Atiyeh","year":"2015","unstructured":"Atiyeh K, Chitkara A, Achlatis S, Branski RC, Amin MR. Allergic reaction to ortho-phthalaldehyde following flexible laryngoscopy. Laryngoscope. 2015;125(10):2349\u201352. https:\/\/doi.org\/10.1002\/lary.25421.","journal-title":"Laryngoscope"},{"issue":"2","key":"1669_CR35","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1539\/joh.48.75","volume":"48","author":"T Takigawa","year":"2006","unstructured":"Takigawa T, Endo Y. Effects of glutaraldehyde exposure on human health. J Occup Health. 2006;48(2):75\u201387. https:\/\/doi.org\/10.1539\/joh.48.75.","journal-title":"J Occup Health"}],"container-title":["Antimicrobial Resistance &amp; Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-025-01669-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13756-025-01669-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-025-01669-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T16:49:29Z","timestamp":1767631769000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13756-025-01669-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,29]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1669"],"URL":"https:\/\/doi.org\/10.1186\/s13756-025-01669-5","relation":{},"ISSN":["2047-2994"],"issn-type":[{"value":"2047-2994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,29]]},"assertion":[{"value":"21 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2"}}