{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T06:25:39Z","timestamp":1786947939416,"version":"build-2736575974"},"reference-count":73,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T00:00:00Z","timestamp":1781136000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":67,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100012331","name":"Agentschap Innoveren en Ondernemen","doi-asserted-by":"publisher","award":["HBC.2021.0849"],"award-info":[{"award-number":["HBC.2021.0849"]}],"id":[{"id":"10.13039\/100012331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Antimicrob Resist Infect Control"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Manual chemical methods are commonly used for ultrasound probe disinfection but are known to be operator dependent and subject to variability. Automated ultraviolet-C (UV-C) light\n                    <jats:bold>-<\/jats:bold>\n                    emitting diode (LED) disinfection represents a chemical and mercury free alternative, however, clinical evidence comparing UV-C LED to conventional disinfectants for high-level disinfection of ultrasound probes remains limited. In this single-centre non-inferiority study conducted in the departments of gynaecology, obstetrics and urology of a Belgian university hospital, automated UV-C LED disinfection was compared to manual chlorine dioxide disinfection for the reprocessing of transabdominal and transvaginal ultrasound probes. Following clinical use, probes were decontaminated by healthcare practitioners alternating between both reprocessing methods. Samples were collected after treatment and processed for microbial analysis to assess the effectiveness of the decontamination process. A total of 296 probes were included, comprising 86 transabdominal and 210 transvaginal probes. UV-C LED disinfection achieved effectiveness rates of 92.86% for transabdominal probes and 97.17% for transvaginal probes, compared with 79.49% and 93.27%, respectively for chlorine dioxide disinfection. Positive samples following UV-C disinfection yielded single colonies whereas chlorine dioxide treated probes showed greater variability in colony counts and species diversity. Although the total reprocessing time for UV-C disinfection was longer, manual handling times were comparable between both methods. Here, we demonstrated that UV-C LED disinfection was non-inferior to chlorine dioxide disinfection for reprocessing of transabdominal and transvaginal ultrasound probes under routine conditions.\n                  <\/jats:p>","DOI":"10.1186\/s13756-026-01777-w","type":"journal-article","created":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T05:22:56Z","timestamp":1781155376000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A non-inferiority trial comparing manual and automated high-level disinfection for reprocessing of transabdominal and transvaginal ultrasound probes"],"prefix":"10.1186","volume":"15","author":[{"given":"Hannah","family":"Siwe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maryse","family":"Van Landegem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shari","family":"De Vriese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Astrid","family":"Luypaert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Merima","family":"Hecimovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven","family":"Weyers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabelle","family":"Dehaene","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Van Laecke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Meuleman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piet","family":"Cools","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,11]]},"reference":[{"issue":"2","key":"1777_CR1","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s13534-017-0021-8","volume":"7","author":"W Lee","year":"2017","unstructured":"Lee W, Roh Y. Ultrasonic transducers for medical diagnostic imaging. Biomed Eng Lett. 2017;7(2):91\u20137.","journal-title":"Biomed Eng Lett"},{"issue":"8","key":"1777_CR2","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1016\/j.ajic.2018.03.025","volume":"46","author":"RM Carrico","year":"2018","unstructured":"Carrico RM, Furmanek S, English C. Ultrasound probe use and reprocessing: Results from a national survey among U.S. infection preventionists. Am J Infect Control. 2018;46(8):913\u201320.","journal-title":"Am J Infect Control"},{"key":"1777_CR3","unstructured":"Centers for Disease Control and Prevention. Guideline for Disinfection and Sterilization in Healthcare Facilities. (2008). Available from: https:\/\/www.cdc.gov\/infection-control\/hcp\/disinfection-and-sterilization\/index.html [accessed 22 April 2026]."},{"issue":"6","key":"1777_CR4","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1007\/s00701-018-3532-x","volume":"160","author":"D Policicchio","year":"2018","unstructured":"Policicchio D, Doda A, Sgaramella E, et al. Ultrasound-guided brain surgery: echographic visibility of different pathologies and surgical applications in neurosurgical routine. Acta Neurochir. 2018;160(6):1175\u201385.","journal-title":"Acta Neurochir"},{"issue":"9","key":"1777_CR5","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1007\/BF02212583","volume":"12","author":"M Hignett","year":"1995","unstructured":"Hignett M, Claman P. High rates of perforation are found in endovaginal ultrasound probe covers before and after oocyte retrieval for in vitro fertilization-embryo transfer. J Assist Reprod Genet. 1995;12(9):606\u20139.","journal-title":"J Assist Reprod Genet"},{"issue":"10","key":"1777_CR6","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1002\/clc.4960161010","volume":"16","author":"S Fritz","year":"1993","unstructured":"Fritz S, Hust MH, Ochs C, et al. Use of a latex cover sheath for transesophageal echocardiography (TEE) instead of regular disinfection of the echoscope? Clin Cardiol. 1993;16(10):737\u201340.","journal-title":"Clin Cardiol"},{"issue":"6","key":"1777_CR7","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1002\/1097-0096(200007\/08)28:6<295::AID-JCU5>3.0.CO;2-G","volume":"28","author":"S Amis","year":"2000","unstructured":"Amis S, Ruddy M, Kibbler CC, Economides DL, MacLean AB. Assessment of condoms as probe covers for transvaginal sonography. J Clin Ultrasound. 2000;28(6):295\u20138.","journal-title":"J Clin Ultrasound"},{"issue":"2","key":"1777_CR8","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.idh.2019.11.003","volume":"25","author":"JM Basseal","year":"2020","unstructured":"Basseal JM, Westerway SC, Hyett JA. Analysis of the integrity of ultrasound probe covers used for transvaginal examinations. Infect Dis Health. 2020;25(2):77\u201381.","journal-title":"Infect Dis Health"},{"issue":"7","key":"1777_CR9","first-page":"E13","volume":"42","author":"AIUM Official Statement","year":"2023","unstructured":"AIUM Official Statement. Guidelines for Cleaning and Preparing External- and Internal-Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel. J Ultrasound Med. 2023;42(7):E13\u201322.","journal-title":"J Ultrasound Med"},{"issue":"80","key":"1777_CR10","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.15557\/JoU.2020.0008","volume":"20","author":"C Caraiani","year":"2020","unstructured":"Caraiani C, Yi D, Petresc B, Dietrich C. Indications for abdominal imaging: When and what to choose? J Ultrason. 2020;20(80):e43\u201354.","journal-title":"J Ultrason"},{"issue":"2","key":"1777_CR11","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.jiph.2013.09.008","volume":"7","author":"K Vickery","year":"2014","unstructured":"Vickery K, Gorgis VZ, Burdach J, Patel D. Evaluation of an automated high-level disinfection technology for ultrasound transducers. J Infect Public Health. 2014;7(2):153\u201360.","journal-title":"J Infect Public Health"},{"key":"1777_CR12","doi-asserted-by":"publisher","first-page":"A79","DOI":"10.1016\/j.ajic.2019.01.015","volume":"47","author":"WA Rutala","year":"2019","unstructured":"Rutala WA, Weber DJ. Reprocessing semicritical items: Outbreaks and current issues. Am J Infect Control. 2019;47:A79\u201389.","journal-title":"Am J Infect Control"},{"issue":"9","key":"1777_CR13","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1080\/08958378.2017.1390015","volume":"29","author":"NR Catlin","year":"2017","unstructured":"Catlin NR, Willson CJ, Stout M, et al. Evaluation of the respiratory tract toxicity of ortho-phthalaldehyde, a proposed alternative for the chemical disinfectant glutaraldehyde. Inhal Toxicol. 2017;29(9):414\u201327.","journal-title":"Inhal Toxicol"},{"issue":"2","key":"1777_CR14","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1539\/joh.48.75","volume":"48","author":"T Takigawa","year":"2006","unstructured":"Takigawa T, Endo Y. Effects of glutaraldehyde exposure on human health. J Occup Health. 2006;48(2):75\u201387.","journal-title":"J Occup Health"},{"key":"1777_CR15","unstructured":"Nelson AL, Porter L. Hydrogen Peroxide Toxicity. StatPearls. Treasure Island (FL): Copyright \u00a9 2026. StatPearls Publishing LLC.; 2026."},{"key":"1777_CR16","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13756-016-0110-y","volume":"5","author":"R Hoyer","year":"2016","unstructured":"Hoyer R, Adhikari S, Amini R. Ultrasound transducer disinfection in emergency medicine practice. Antimicrob Resist Infect Control. 2016;5:12.","journal-title":"Antimicrob Resist Infect Control"},{"issue":"2","key":"1777_CR17","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10396-010-0296-1","volume":"38","author":"H Koibuchi","year":"2011","unstructured":"Koibuchi H, Fujii Y, Kotani K, et al. Degradation of ultrasound probes caused by disinfection with alcohol. J Med Ultrason. 2011;38(2):97\u2013100.","journal-title":"J Med Ultrason"},{"issue":"1","key":"1777_CR18","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1177\/1742271X13511805","volume":"22","author":"N Dudley","year":"2014","unstructured":"Dudley N, Russell S, Ward B, Hoskins P. BMUS guidelines for the regular quality assurance testing of ultrasound scanners by sonographers. Ultrasound. 2014;22(1):8\u201314.","journal-title":"Ultrasound"},{"key":"1777_CR19","unstructured":"Siemens. General Handling of Siemens Healthineers Transducers. Available from: https:\/\/www.siemens-healthineers.com\/ultrasound\/ultrasound-transducer-catalog [accessed 22 April 2026]."},{"key":"1777_CR20","unstructured":"Philips. Transducer and System Care and Cleaning. Available from: https:\/\/www.philips.ae\/c-dam\/b2bhc\/us\/feature-details\/transducer-care\/Transducer-care-cleaning-english.pdf [accessed 22 April 2026]."},{"issue":"5","key":"1777_CR21","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1016\/j.ultrasmedbio.2017.01.002","volume":"43","author":"JS Abramowicz","year":"2017","unstructured":"Abramowicz JS, Evans DH, Fowlkes JB, Mar\u0161al K, terHaar G. Guidelines for Cleaning Transvaginal Ultrasound Transducers Between Patients. Ultrasound Med Biol. 2017;43(5):1076\u20139.","journal-title":"Ultrasound Med Biol"},{"key":"1777_CR22","unstructured":"Food and Drug Administration. De Novo classification request for Tristel Duo ULT high level disinfectant. 2023. Available from: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/reviews\/DEN220041.pdf [accessed 30 April 2026]."},{"key":"1777_CR23","unstructured":"EUDAMED - European Database on Medical Devices. Available from: https:\/\/ec.europa.eu\/tools\/eudamed\/#\/screen\/search-device\/9d462fdc-2a14-4988-904d-bc4c91c84350 [accessed 06 December 2025]."},{"issue":"1","key":"1777_CR24","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1002\/uog.24834","volume":"60","author":"C Kyriacou","year":"2022","unstructured":"Kyriacou C, Robinson E, Barcroft J, et al. Time-effectiveness and convenience of transvaginal ultrasound probe disinfection using ultraviolet vs chlorine dioxide multistep wipe system: prospective survey study. Ultrasound Obstet Gynecol. 2022;60(1):132\u20138.","journal-title":"Ultrasound Obstet Gynecol"},{"issue":"2","key":"1777_CR25","doi-asserted-by":"publisher","first-page":"e0298449","DOI":"10.1371\/journal.pone.0298449","volume":"19","author":"M Yasir","year":"2024","unstructured":"Yasir M, Willcox MDP. The use of ultraviolet light generated from light-emitting diodes for the disinfection of transvaginal ultrasound probes. PLoS ONE. 2024;19(2):e0298449.","journal-title":"PLoS ONE"},{"issue":"3","key":"1777_CR26","doi-asserted-by":"publisher","first-page":"102415","DOI":"10.1016\/j.amjoto.2020.102415","volume":"41","author":"M Tofanelli","year":"2020","unstructured":"Tofanelli M, Capriotti V, Saraniti C, et al. Disposable chlorine dioxide wipes for high-level disinfection in the ENT department: A systematic review. Am J Otolaryngol. 2020;41(3):102415.","journal-title":"Am J Otolaryngol"},{"issue":"8","key":"1777_CR27","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1086\/506397","volume":"27","author":"MJ Alfa","year":"2006","unstructured":"Alfa MJ, Nemes R, Olson N, Mulaire A. Manual methods are suboptimal compared with automated methods for cleaning of single-use biopsy forceps. Infect Control Hosp Epidemiol. 2006;27(8):841\u20136.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1777_CR28","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/B978-0-08-102565-9.00015-7","volume-title":"Decontamination in Hospitals and Healthcare","author":"JA Otter","year":"2020","unstructured":"Otter JA, Yezli S, Barbut F, Perl TM. 15 - An overview of automated room disinfection systems: When to use them and how to choose them. In: Walker J, editor. Decontamination in Hospitals and Healthcare. Second Edition): Woodhead Publishing; 2020. pp. 323\u201369."},{"issue":"5","key":"1777_CR29","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1213\/01.ANE.0000083641.58267.0C","volume":"97","author":"SG Venticinque","year":"2003","unstructured":"Venticinque SG, Kashyap VS, O\u2019Connell RJ. Chemical burn injury secondary to intraoperative transesophageal echocardiography. Anesth Analg. 2003;97(5):1260\u20131.","journal-title":"Anesth Analg"},{"key":"1777_CR30","unstructured":"World Health Organization. Global report on infection prevention and control. 2024. Available from: https:\/\/www.who.int\/publications\/i\/item\/9789240103986 [accessed 30 April 2026]."},{"key":"1777_CR31","unstructured":"World Health Organization. WHO Guidelines on Hand Hygiene in Health Care. 2009. Available from: https:\/\/organesdeconcertation.sante.belgique.be\/sites\/default\/files\/documents\/who_guidelines_on_hand_hygiene_in_health_care.pdf [accessed 30 April 2026]."},{"issue":"5","key":"1777_CR32","doi-asserted-by":"publisher","first-page":"928","DOI":"10.2214\/AJR.13.12407","volume":"203","author":"K Chu","year":"2014","unstructured":"Chu K, Obaid H, Babyn P, Blondeau J. Bacterial contamination of ultrasound probes at a tertiary referral university medical center. AJR Am J Roentgenol. 2014;203(5):928\u201332.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1777_CR33","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1002\/aorn.13572","volume":"115","author":"K de Souza Hajar","year":"2022","unstructured":"de Souza Hajar K, Quartim de Moraes Bruna C, Uchikawa Graziano K. Infection Transmission Associated With Contaminated Ultrasound Probes: A Systematic Review. Aorn j. 2022;115(1):42\u201351.","journal-title":"Aorn j"},{"issue":"5","key":"1777_CR34","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.urology.2007.01.047","volume":"69","author":"JL Gillespie","year":"2007","unstructured":"Gillespie JL, Arnold KE, Noble-Wang J, et al. Outbreak of Pseudomonas aeruginosa Infections After Transrectal Ultrasound-Guided Prostate Biopsy. Urology. 2007;69(5):912\u20134.","journal-title":"Urology"},{"key":"1777_CR35","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/1476-0711-8-7","volume":"8","author":"F Ulger","year":"2009","unstructured":"Ulger F, Esen S, Dilek A, et al. Are we aware how contaminated our mobile phones with nosocomial pathogens? Ann Clin Microbiol Antimicrob. 2009;8:7.","journal-title":"Ann Clin Microbiol Antimicrob"},{"issue":"2","key":"1777_CR36","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.jhin.2008.06.007","volume":"70","author":"J Ramesh","year":"2008","unstructured":"Ramesh J, Carter AO, Campbell MH, et al. Use of mobile phones by medical staff at Queen Elizabeth Hospital, Barbados: evidence for both benefit and harm. J Hosp Infect. 2008;70(2):160\u20135.","journal-title":"J Hosp Infect"},{"issue":"11","key":"1777_CR37","first-page":"348","volume":"106","author":"R Madar","year":"2005","unstructured":"Madar R, Novakova E, Baska T. The role of non-critical health-care tools in the transmission of nosocomial infections. Bratisl Lek Listy. 2005;106(11):348\u201350.","journal-title":"Bratisl Lek Listy"},{"issue":"10","key":"1777_CR38","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1007\/s00103-012-1548-6","volume":"55","author":"Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten","year":"2012","unstructured":"Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten. Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz. 2012;55(10):1244\u2013310.","journal-title":"Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz"},{"key":"1777_CR39","unstructured":"Health Technical Memorandum 01\u201301. Decontamination of reusable medical devices. Available from: https:\/\/data.parliament.uk\/DepositedPapers\/Files\/DEP2008-0967\/DEP2008-0967.pdf [accessed 30 April 2026]."},{"issue":"11","key":"1777_CR40","doi-asserted-by":"publisher","first-page":"e0268863","DOI":"10.1371\/journal.pone.0268863","volume":"17","author":"SA Rudhart","year":"2022","unstructured":"Rudhart SA, G\u00fcnther F, Dapper LI, et al. Analysis of bacterial contamination and the effectiveness of UV light-based reprocessing of everyday medical devices. PLoS ONE. 2022;17(11):e0268863.","journal-title":"PLoS ONE"},{"issue":"1","key":"1777_CR41","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1186\/s13756-024-01486-2","volume":"13","author":"Y Halmans","year":"2024","unstructured":"Halmans Y, Wellenstein DJ, Romijn M, et al. A multicenter study comparing the bacterial reduction on flexible endoscopes without a working channel between UV-C light disinfection versus standard endoscope Washer Disinfection: a randomized controlled trial. Antimicrob Resist Infect Control. 2024;13(1):128.","journal-title":"Antimicrob Resist Infect Control"},{"issue":"3","key":"1777_CR42","doi-asserted-by":"publisher","first-page":"e60","DOI":"10.1016\/j.jhin.2018.04.002","volume":"100","author":"M Muzslay","year":"2018","unstructured":"Muzslay M, Yui S, Ali S, Wilson APR. Ultraviolet-C decontamination of hand-held tablet devices in the healthcare environment using the Codonics D6000\u2122 disinfection system. J Hosp Infect. 2018;100(3):e60\u20133.","journal-title":"J Hosp Infect"},{"key":"1777_CR43","unstructured":"The British Standards Institution. BS8628:2022 - Disinfection using ultraviolet radiation. Methods for quantitative testing of automated ultraviolet disinfection activities by direct illumination. Determination of bactericidal, mycobactericidal, sporicidal, yeasticidal, fungicidal, virucidal and phagocidal activities."},{"key":"1777_CR44","unstructured":"Royal Netherlands Standardization Institute. NEN 8281:2025 - UV-C Disinfection of non-critical and semi-critical medical devices."},{"key":"1777_CR45","unstructured":"Association Fran\u00e7aise de Normalisation. AFNOR SPEC T72-902:2021 - Use of UV-C techology for disinfection and decontamination purposes."},{"issue":"7","key":"1777_CR46","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.3390\/microorganisms8071014","volume":"8","author":"M Kojima","year":"2020","unstructured":"Kojima M, Mawatari K, Emoto T, et al. Irradiation by a Combination of Different Peak-Wavelength Ultraviolet-Light Emitting Diodes Enhances the Inactivation of Influenza A Viruses. Microorganisms. 2020;8(7):1014.","journal-title":"Microorganisms"},{"key":"1777_CR47","doi-asserted-by":"publisher","first-page":"112410","DOI":"10.1016\/j.jphotobiol.2022.112410","volume":"228","author":"TKN Bui","year":"2022","unstructured":"Bui TKN, Mawatari K, Emoto T, et al. UV-LED irradiation reduces the infectivity of herpes simplex virus type 1 by targeting different viral components depending on the peak wavelength. J Photochem Photobiol B. 2022;228:112410.","journal-title":"J Photochem Photobiol B"},{"key":"1777_CR48","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.desal.2013.08.014","volume":"328","author":"K Oguma","year":"2013","unstructured":"Oguma K, Kita R, Sakai H, Murakami M, Takizawa S. Application of UV light emitting diodes to batch and flow-through water disinfection systems. Desalination. 2013;328:24\u201330.","journal-title":"Desalination"},{"key":"1777_CR49","first-page":"100271","volume":"25","author":"KD Rauch","year":"2024","unstructured":"Rauch KD, MacIsaac SA, Reid B, et al. A critical review of ultra-violet light emitting diodes as a one water disinfection technology. Water Res X. 2024;25:100271.","journal-title":"Water Res X"},{"issue":"12","key":"1777_CR50","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.ajic.2022.02.027","volume":"50","author":"L Pineau","year":"2022","unstructured":"Pineau L, Radix C, Weber DJ. Comparison of the sporicidal activity of a UV disinfection process with three FDA cleared sterilants. Am J Infect Control. 2022;50(12):1316\u201321.","journal-title":"Am J Infect Control"},{"issue":"2","key":"1777_CR51","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jhin.2006.10.008","volume":"65","author":"G Kac","year":"2007","unstructured":"Kac G, Gueneret M, Rodi A, et al. Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet light. J Hosp Infect. 2007;65(2):163\u20138.","journal-title":"J Hosp Infect"},{"key":"1777_CR52","doi-asserted-by":"crossref","unstructured":"Pichon M, Lebail-Carval K, Billaud G et al. Decontamination of Intravaginal Probes Infected by Human Papillomavirus (HPV) Using UV-C Decontamination System. J Clin Med. 2019;8(11).","DOI":"10.3390\/jcm8111776"},{"issue":"6","key":"1777_CR53","doi-asserted-by":"publisher","first-page":"785","DOI":"10.7863\/jum.2011.30.6.785","volume":"30","author":"S Bloc","year":"2011","unstructured":"Bloc S, Mercadal L, Garnier T, et al. Evaluation of a new disinfection method for ultrasound probes used for regional anesthesia: ultraviolet C light. J Ultrasound Med. 2011;30(6):785\u20138.","journal-title":"J Ultrasound Med"},{"issue":"2","key":"1777_CR54","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1086\/649794","volume":"31","author":"G Kac","year":"2010","unstructured":"Kac G, Podglajen I, Si-Mohamed A, et al. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol. 2010;31(2):165\u201370.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"1777_CR55","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1186\/1471-2334-12-174","volume":"12","author":"G Moore","year":"2012","unstructured":"Moore G, Ali S, Cloutman-Green EA, et al. Use of UV-C radiation to disinfect non-critical patient care items: a laboratory assessment of the Nanoclave Cabinet. BMC Infect Dis. 2012;12:174.","journal-title":"BMC Infect Dis"},{"issue":"9","key":"1777_CR56","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1093\/annweh\/wxaa080","volume":"64","author":"AM Madsen","year":"2020","unstructured":"Madsen AM, Phan HUT, Laursen M, White JK, Uhrbrand K. Evaluation of Methods for Sampling of Staphylococcus aureus and Other Staphylococcus Species from Indoor Surfaces. Ann Work Expo Health. 2020;64(9):1020\u201334.","journal-title":"Ann Work Expo Health"},{"issue":"8","key":"1777_CR57","doi-asserted-by":"publisher","first-page":"e0132149","DOI":"10.1371\/journal.pone.0132149","volume":"10","author":"H Duyvejonck","year":"2015","unstructured":"Duyvejonck H, Cools P, Decruyenaere J, et al. Validation of High Resolution Melting Analysis (HRM) of the Amplified ITS2 Region for the Detection and Identification of Yeasts from Clinical Samples: Comparison with Culture and MALDI-TOF Based Identification. PLoS ONE. 2015;10(8):e0132149.","journal-title":"PLoS ONE"},{"issue":"10","key":"1777_CR58","doi-asserted-by":"publisher","first-page":"e61","DOI":"10.1016\/j.ajic.2015.06.019","volume":"43","author":"G Messina","year":"2015","unstructured":"Messina G, Burgassi S, Messina D, Montagnani V, Cevenini G. A new UV-LED device for automatic disinfection of stethoscope membranes. Am J Infect Control. 2015;43(10):e61\u20136.","journal-title":"Am J Infect Control"},{"issue":"8","key":"1777_CR59","first-page":"e65963","volume":"16","author":"S Gibbons","year":"2024","unstructured":"Gibbons S, Dexter F, Loftus RW, et al. Surface Cleaning with a Microfiber Cloth and Water followed by Ultraviolet-C Light Exposure Achieves Non-Inferior Disinfection of a Pathogenic Staphylococcus aureus Strain versus Use of Germicidal Wipes. Cureus. 2024;16(8):e65963.","journal-title":"Cureus"},{"key":"1777_CR60","unstructured":"PDI. Sani-Cloth active safety sheet. Available from: https:\/\/www.galaxyhealthcare.ie\/wp-content\/uploads\/2022\/12\/Safety-Data-Sheet-PDI-Sani-Cloth-Active.pdf [accessed 30 April 2026]."},{"key":"1777_CR61","unstructured":"Food and Drug Administration. Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling. 2015. Available from: https:\/\/www.fda.gov\/media\/80265\/download [accessed 30 April 2026]."},{"key":"1777_CR62","doi-asserted-by":"publisher","first-page":"108836","DOI":"10.1016\/j.envint.2024.108836","volume":"190","author":"H Salonen","year":"2024","unstructured":"Salonen H, Salthammer T, Castagnoli E, T\u00e4ubel M, Morawska L. Cleaning products: Their chemistry, effects on indoor air quality, and implications for human health. Environ Int. 2024;190:108836.","journal-title":"Environ Int"},{"key":"1777_CR63","unstructured":"Food and Drug Administration. Guidance for Industry: Pyrogen and Endotoxins Testing: Questions and Answers. 2012. Available from: https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/guidance-industry-pyrogen-and-endotoxins-testing-questions-and-answers#_Toc315937935 [accessed 11 February 2026]."},{"issue":"2","key":"1777_CR64","doi-asserted-by":"publisher","first-page":"189","DOI":"10.3390\/hygiene4020015","volume":"4","author":"C K\u00fchnel","year":"2024","unstructured":"K\u00fchnel C, G\u00fchne F. Visualization of Effectiveness: The Use of a Set of Colored Cleaning Wipes for Visible Disinfection of Ultrasound Probes. Hygiene. 2024;4(2):189\u201396.","journal-title":"Hygiene"},{"issue":"2","key":"1777_CR65","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1586\/edm.10.6","volume":"5","author":"M Otto","year":"2010","unstructured":"Otto M. Staphylococcus colonization of the skin and antimicrobial peptides. Expert Rev Dermatol. 2010;5(2):183\u201395.","journal-title":"Expert Rev Dermatol"},{"issue":"4","key":"1777_CR66","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1128\/CMR.00109-13","volume":"27","author":"K Becker","year":"2014","unstructured":"Becker K, Heilmann C, Peters G. Coagulase-negative staphylococci. Clin Microbiol Rev. 2014;27(4):870\u2013926.","journal-title":"Clin Microbiol Rev"},{"issue":"3","key":"1777_CR67","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1046\/j.0022-202x.2001.00043.x","volume":"6","author":"K Chiller","year":"2001","unstructured":"Chiller K, Selkin BA, Murakawa GJ. Skin Microflora and Bacterial Infections of the Skin. J Investig Dermatol Symp Proc. 2001;6(3):170\u20134.","journal-title":"J Investig Dermatol Symp Proc"},{"key":"1777_CR68","doi-asserted-by":"publisher","first-page":"e01450","DOI":"10.1016\/j.idcr.2022.e01450","volume":"27","author":"J Koleri","year":"2022","unstructured":"Koleri J, Petkar HM, Husain AAM, Almaslamani MA, Omrani AS. Moraxella osloensis bacteremia, a case series and review of the literature. IDCases. 2022;27:e01450.","journal-title":"IDCases"},{"issue":"4","key":"1777_CR69","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1038\/nrmicro2537","volume":"9","author":"EA Grice","year":"2011","unstructured":"Grice EA, Segre JA. The skin microbiome. Nat Rev Microbiol. 2011;9(4):244\u201353.","journal-title":"Nat Rev Microbiol"},{"key":"1777_CR70","doi-asserted-by":"publisher","first-page":"101705","DOI":"10.1016\/j.nmni.2026.101705","volume":"70","author":"MP Ryan","year":"2026","unstructured":"Ryan MP, Tony Pembroke J. Delftia spp as Opportunistic Pathogens: a narrative review. New Microbes New Infect. 2026;70:101705.","journal-title":"New Microbes New Infect"},{"issue":"3","key":"1777_CR71","doi-asserted-by":"publisher","first-page":"574","DOI":"10.4056\/sigs.4688352","volume":"9","author":"L Zhang","year":"2014","unstructured":"Zhang L, Li X, Zhang F, Wang G. Genomic analysis of Agrobacterium radiobacter DSM 30147(T) and emended description of A. radiobacter (Beijerinck and van Delden 1902) Conn 1942 (Approved Lists 1980) emend. Sawada et al. 1993. Stand Genomic Sci. 2014;9(3):574\u201384.","journal-title":"Stand Genomic Sci"},{"key":"1777_CR72","unstructured":"European Commission. Mercury - Protecting human health and the environment from the harmful effects of mercury. Available from: https:\/\/environment.ec.europa.eu\/topics\/chemicals\/mercury_en [accessed 11 February 2026]."},{"key":"1777_CR73","doi-asserted-by":"publisher","first-page":"100557","DOI":"10.1016\/j.ese.2025.100557","volume":"25","author":"M Sousa","year":"2025","unstructured":"Sousa M, Machado I, Sim\u00f5es LC, Sim\u00f5es M. Biocides as drivers of antibiotic resistance: A critical review of environmental implications and public health risks. Environ Sci Ecotechnol. 2025;25:100557.","journal-title":"Environ Sci Ecotechnol"}],"container-title":["Antimicrobial Resistance &amp; Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13756-026-01777-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-026-01777-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13756-026-01777-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T06:01:55Z","timestamp":1786946515000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13756-026-01777-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,11]]},"references-count":73,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1777"],"URL":"https:\/\/doi.org\/10.1186\/s13756-026-01777-w","relation":{},"ISSN":["2047-2994"],"issn-type":[{"value":"2047-2994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,11]]},"assertion":[{"value":"12 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Ethical Committee of the Ghent University Hospital (reference number ONZ-2024-0561). Informed consent of patients was not required as the study did not involve direct patient contact or modification of standard care.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"HS is employed by eLEDricity and is a doctoral researcher at Ghent University. The study was conducted within a Baekeland PhD mandate involving the collaboration between Ghent University and eLEDricity. The study design was developed collaboratively between the academic investigators and the industrial partner, whereas scientific conduct of the study, data collection, analysis, interpretation, and manuscript preparation were performed under academic supervision by the PhD candidate and academic promotors. The manufacturer had no role in the final interpretation of the data or the decision to submit the manuscript for publication. All other authors declare they have nothing to disclose.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"107"}}