{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T16:54:53Z","timestamp":1782752093846,"version":"3.54.5"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T00:00:00Z","timestamp":1710201600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T00:00:00Z","timestamp":1710201600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Med Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Necrosis of the femoral head is the main complication in femoral neck fracture patients with triangle cannulated screw fixation. Instant postoperative fixation instability is a main reason for the higher risk of femoral head necrosis. Biomechanical studies have shown that cross screw fixation can effectively optimize fixation stability in patients with proximal humerus fractures and pedicle screw fixation, but whether this method can also effectively optimize the fixation stability of femoral neck fractures and reduce the corresponding risk of femoral head necrosis has yet to be identified. In this study, a retrospective review of imaging data in femoral neck fracture patients was performed. The cross angle between the femoral neck and the caudal cannulated screw was reported; if the angle between the screw and the transverse plane increased, it was recorded as positive; otherwise, it was recorded as negative. Angle values and their corresponding absolute values were compared in patients with and without femoral head necrosis. Regression analysis identified potential risk factors for femoral head necrosis. Moreover, the biomechanical effect of the screw\u2013femoral neck angle on fixation stability was also verified by numerical mechanical simulations. Clinical review presented significantly larger positive angle values in patients with femoral head necrosis, which was also proven to be an independent risk factor for this complication. Moreover, fixation stability progressively deteriorated with increasing angle between the caudal screw and the transverse plane. Therefore, increasing the angle between the caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.<\/jats:p>","DOI":"10.1186\/s40001-024-01737-3","type":"journal-article","created":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T06:43:33Z","timestamp":1710225813000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture"],"prefix":"10.1186","volume":"29","author":[{"given":"Jian","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shengyu","family":"Wan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaozhong","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caidong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lipeng","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingchi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,12]]},"reference":[{"key":"1737_CR1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199706000-00004","author":"TJ Bray","year":"1997","unstructured":"Bray TJ. Femoral neck fracture fixation. Clinical decision making. Clin Orthop Related Res. 1997. https:\/\/doi.org\/10.1097\/00003086-199706000-00004.","journal-title":"Clin Orthop Related Res"},{"key":"1737_CR2","first-page":"1124","volume":"69","author":"C Bastard","year":"2019","unstructured":"Bastard C. Femoral neck fracture. Rev Prat. 2019;69:1124\u20138.","journal-title":"Rev Prat"},{"key":"1737_CR3","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1097\/01.blo.0000238815.40777.d2","volume":"455","author":"HK Hamelinck","year":"2007","unstructured":"Hamelinck HK, Haagmans M, Snoeren MM, Biert J, van Vugt AB, Fr\u00f6lke JP. Safety of computer-assisted surgery for cannulated hip screws. Clin Orthop Relat Res. 2007;455:241\u20135. https:\/\/doi.org\/10.1097\/01.blo.0000238815.40777.d2.","journal-title":"Clin Orthop Relat Res"},{"key":"1737_CR4","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph19127348","author":"W Konarski","year":"2022","unstructured":"Konarski W, Pobo\u017cy T, \u015aliwczy\u0144ski A, Kotela I, Krakowiak J, Hordowicz M, Kotela A. Avascular necrosis of femoral head-overview and current state of the art. Int J Environ Res Public Health. 2022. https:\/\/doi.org\/10.3390\/ijerph19127348.","journal-title":"Int J Environ Res Public Health"},{"key":"1737_CR5","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.gendis.2019.04.006","volume":"7","author":"H Lu","year":"2020","unstructured":"Lu H, Shen H, Zhou S, Ni W, Jiang D. Biomechanical analysis of the computer-assisted internal fixation of a femoral neck fracture. Genes Dis. 2020;7:448\u201355. https:\/\/doi.org\/10.1016\/j.gendis.2019.04.006.","journal-title":"Genes Dis"},{"key":"1737_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2022.09.006","author":"H Lin","year":"2022","unstructured":"Lin H, Lai C, Zhou Z, Wang C, Yu X. Femoral neck system vs. four cannulated screws in the treatment of Pauwels III femoral neck fracture. J Orthop Sci. 2022. https:\/\/doi.org\/10.1016\/j.jos.2022.09.006.","journal-title":"J Orthop Sci"},{"key":"1737_CR7","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","volume":"46","author":"GP Slobogean","year":"2015","unstructured":"Slobogean GP, Sprague SA, Scott T, Bhandari M. Complications following young femoral neck fractures. Injury. 2015;46:484\u201391. https:\/\/doi.org\/10.1016\/j.injury.2014.10.010.","journal-title":"Injury"},{"issue":"Suppl 1","key":"1737_CR8","doi-asserted-by":"publisher","first-page":"S70","DOI":"10.1016\/j.injury.2021.09.024","volume":"54","author":"F Randelli","year":"2023","unstructured":"Randelli F, Vigan\u00f2 M, Liccardi A, Mazzoleni MG, Basile G, Menon A, Cosmelli N. Femoral neck fractures: key points to consider for fixation or replacement a narrative review of recent literature. Injury. 2023;54(Suppl 1):S70-s77. https:\/\/doi.org\/10.1016\/j.injury.2021.09.024.","journal-title":"Injury"},{"key":"1737_CR9","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/bot.0000000000000291","volume":"29","author":"AV Florschutz","year":"2015","unstructured":"Florschutz AV, Langford JR, Haidukewych GJ, Koval KJ. Femoral neck fractures: current management. J Orthop Trauma. 2015;29:121\u20139. https:\/\/doi.org\/10.1097\/bot.0000000000000291.","journal-title":"J Orthop Trauma"},{"key":"1737_CR10","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1016\/j.injury.2019.02.010","volume":"50","author":"J Herzog","year":"2019","unstructured":"Herzog J, Wendlandt R, Hillbricht S, Burgkart R, Schulz AP. Optimising the tip-apex-distance in trochanteric femoral fracture fixation using the ADAPT-navigated technique, a longitudinal matched cohort study. Injury. 2019;50:744\u201351. https:\/\/doi.org\/10.1016\/j.injury.2019.02.010.","journal-title":"Injury"},{"key":"1737_CR11","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1177\/0954411918789963","volume":"232","author":"E Sensoz","year":"2018","unstructured":"Sensoz E, \u00d6zkal FM, Acar V, Cakir F. Finite element analysis of the impact of screw insertion distal to the trochanter minor on the risk of iatrogenic subtrochanteric fracture. Proc Inst Mech Eng. 2018;232:807\u201318. https:\/\/doi.org\/10.1177\/0954411918789963.","journal-title":"Proc Inst Mech Eng"},{"key":"1737_CR12","doi-asserted-by":"publisher","first-page":"108658","DOI":"10.1016\/j.biopha.2019.108658","volume":"112","author":"L Tianye","year":"2019","unstructured":"Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, Qingwen Z. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharm. 2019;112:108658. https:\/\/doi.org\/10.1016\/j.biopha.2019.108658.","journal-title":"Biomed Pharm"},{"key":"1737_CR13","doi-asserted-by":"publisher","first-page":"215145932199266","DOI":"10.1177\/2151459321992666","volume":"12","author":"Y Shu","year":"2021","unstructured":"Shu Y, Chen M, Yu W, Ge Z, Hu H, Zhang X, Zeng X, Liu X. PHILOS plate plus oblique insertion of autologous fibula for 2-part proximal humerus fractures with medial column disruption: a retrospective study. Geriatr Orthop Surgery Rehabilit. 2021;12:2151459321992666. https:\/\/doi.org\/10.1177\/2151459321992666.","journal-title":"Geriatr Orthop Surgery Rehabilit"},{"key":"1737_CR14","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1186\/s12893-022-01557-4","volume":"22","author":"D Li","year":"2022","unstructured":"Li D, Lv W, Chen W, Meng J, Liu S, Duan Z, Yu B. Application of a lateral intertubercular sulcus plate in the treatment of proximal humeral fractures: a finite element analysis. BMC Surg. 2022;22:98. https:\/\/doi.org\/10.1186\/s12893-022-01557-4.","journal-title":"BMC Surg"},{"key":"1737_CR15","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1097\/BOT.0b013e318229acca","volume":"26","author":"PR Kuzyk","year":"2012","unstructured":"Kuzyk PR, Zdero R, Shah S, Olsen M, Waddell JP, Schemitsch EH. Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis. J Orthop Trauma. 2012;26:414\u201321. https:\/\/doi.org\/10.1097\/BOT.0b013e318229acca.","journal-title":"J Orthop Trauma"},{"key":"1737_CR16","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1148\/radiol.14131390","volume":"272","author":"J Thevenot","year":"2014","unstructured":"Thevenot J, Hirvasniemi J, Pulkkinen P, M\u00e4\u00e4tt\u00e4 M, Korpelainen R, Saarakkala S, J\u00e4ms\u00e4 T. Assessment of risk of femoral neck fracture with radiographic texture parameters: a retrospective study. Radiology. 2014;272:184\u201391. https:\/\/doi.org\/10.1148\/radiol.14131390.","journal-title":"Radiology"},{"key":"1737_CR17","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1097\/js9.0000000000000369","volume":"109","author":"YS Deng","year":"2023","unstructured":"Deng YS, Jiang GL, Cao YF, Deng HY, Yang HP, Zhu ZB, Wu DQ, Wang QG. Orientated-quantitative computed tomography study on individualized axial safety target area of femoral neck screw channel and establishment of a stable spatial coordinate system based on anterior cortex of femoral neck basilar. Int J Surgery. 2023;109:1158\u201368. https:\/\/doi.org\/10.1097\/js9.0000000000000369.","journal-title":"Int J Surgery"},{"key":"1737_CR18","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1055\/s-0031-1278427","volume":"15","author":"AH Karantanas","year":"2011","unstructured":"Karantanas AH, Drakonaki EE. The role of MR imaging in avascular necrosis of the femoral head. Semin Musculoskeletal Radiol. 2011;15:281\u2013300. https:\/\/doi.org\/10.1055\/s-0031-1278427.","journal-title":"Semin Musculoskeletal Radiol"},{"key":"1737_CR19","doi-asserted-by":"crossref","unstructured":"Perazzo H, Fernandes FF, Soares JC, Fittipaldi J, Cardoso SW, Grinsztejn B, Veloso VG: Learning curve and intra\/interobserver agreement of transient elastography in chronic hepatitis C patients with or without HIV co-infection. Clin Res Hepatol Gastroenterol 2016, 40:73-82.","DOI":"10.1016\/j.clinre.2015.04.004"},{"key":"1737_CR20","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/j.1469-1809.1993.tb00897.x","volume":"57","author":"MS Srivastava","year":"1993","unstructured":"Srivastava MS. Estimation of the intraclass correlation coefficient. Ann Hum Genet. 1993;57:159\u201365. https:\/\/doi.org\/10.1111\/j.1469-1809.1993.tb00897.x.","journal-title":"Ann Hum Genet"},{"key":"1737_CR21","doi-asserted-by":"publisher","first-page":"3046","DOI":"10.1007\/s00330-015-4145-x","volume":"26","author":"E Pompe","year":"2016","unstructured":"Pompe E, de Jong PA, de Jong WU, Takx RA, Eikendal AL, Willemink MJ, Oudkerk M, Budde RP, Lammers JW, Mohamed Hoesein FA. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography. Eur Radiol. 2016;26:3046\u201353. https:\/\/doi.org\/10.1007\/s00330-015-4145-x.","journal-title":"Eur Radiol"},{"key":"1737_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-022-09157-9","author":"J Li","year":"2022","unstructured":"Li J, Zhang Z, Xie T, Song Z, Song Y, Zeng J. The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods. Eur Radiol. 2022. https:\/\/doi.org\/10.1007\/s00330-022-09157-9.","journal-title":"Eur Radiol"},{"key":"1737_CR23","doi-asserted-by":"publisher","DOI":"10.1097\/js9.0000000000000273","author":"J Li","year":"2023","unstructured":"Li J, Xie Y, Sun S, Xue C, Xu W, Xu C, Xi Z. Regional differences in bone mineral density biomechanically induce a higher risk of adjacent vertebral fracture after percutaneous vertebroplasty: a case-comparative study. Int J Surgery. 2023. https:\/\/doi.org\/10.1097\/js9.0000000000000273.","journal-title":"Int J Surgery"},{"key":"1737_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2023.08.003","author":"Z Xi","year":"2023","unstructured":"Xi Z, Xie Y, Chen S, Sun S, Zhang X, Yang J, Li J. The cranial vertebral body suffers a higher risk of adjacent vertebral fracture due to the poor biomechanical environment in patients with percutaneous vertebralplasty. Spine J. 2023. https:\/\/doi.org\/10.1016\/j.spinee.2023.08.003.","journal-title":"Spine J"},{"key":"1737_CR25","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.862951","volume":"10","author":"JC Li","year":"2022","unstructured":"Li JC, Xie TH, Zhang Z, Song ZT, Song YM, Zeng JC. The Mismatch between bony endplates and grafted bone increases screw loosening risk for OLIF patients with ALSR fixation biomechanically. Front Bioeng Biotechnol. 2022;10: 862951. https:\/\/doi.org\/10.3389\/fbioe.2022.862951.","journal-title":"Front Bioeng Biotechnol"},{"key":"1737_CR26","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.922848","volume":"10","author":"JC Li","year":"2022","unstructured":"Li JC, Yang ZQ, Xie TH, Song ZT, Song YM, Zeng JC. Deterioration of the fixation segment\u2019s stress distribution and the strength reduction of screw holding position together cause screw loosening in ALSR fixed OLIF patients with poor BMD. Front Bioeng Biotechnol. 2022;10: 922848. https:\/\/doi.org\/10.3389\/fbioe.2022.922848.","journal-title":"Front Bioeng Biotechnol"},{"key":"1737_CR27","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1016\/j.injury.2019.02.008","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Han L, Zhang H, Zhao Z, Su X, Zhou J, Li C, Yin P, Hao M, Wang K, Xu G, Zhang L, Zhang L, Tang P. Medial sustainable nail versus proximal femoral nail antirotation in treating AO\/OTA 31\u2013A2.3 fractures: finite element analysis and biomechanical evaluation. Injury. 2019;50:648\u201356. https:\/\/doi.org\/10.1016\/j.injury.2019.02.008.","journal-title":"Injury"},{"key":"1737_CR28","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Yin P, Zhang L, Chen H, Tang P. Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis. Injury. 2019;50:1895\u2013900. https:\/\/doi.org\/10.1016\/j.injury.2019.08.024.","journal-title":"Injury"},{"key":"1737_CR29","doi-asserted-by":"publisher","first-page":"3009","DOI":"10.1111\/os.13497","volume":"14","author":"S Nie","year":"2022","unstructured":"Nie S, Li J, Li M, Hao M, Wang K, Xiong Y, Gan X, Zhang L, Tang P. Finite-element analysis of a novel cephalomedullary nail for restricted sliding to reduce risk of implant failure in unstable intertrochanteric fractures. Orthop Surg. 2022;14:3009\u201318. https:\/\/doi.org\/10.1111\/os.13497.","journal-title":"Orthop Surg"},{"key":"1737_CR30","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1186\/s13018-021-02655-4","volume":"16","author":"J Li","year":"2021","unstructured":"Li J, Xu C, Zhang X, Xi Z, Sun S, Zhang K, Fang X, Xie L, Liu Y, Song Y. Disc measurement and nucleus calibration in a smoothened lumbar model increases the accuracy and efficiency of in-silico study. J Orthop Surg Res. 2021;16:498. https:\/\/doi.org\/10.1186\/s13018-021-02655-4.","journal-title":"J Orthop Surg Res"},{"key":"1737_CR31","doi-asserted-by":"publisher","DOI":"10.1177\/21925682221081224","author":"C Xu","year":"2022","unstructured":"Xu C, Xi Z, Fang Z, Zhang X, Wang N, Li J, Liu Y. Annulus calibration increases the computational accuracy of the lumbar finite element model. Global Spine J. 2022. https:\/\/doi.org\/10.1177\/21925682221081224.","journal-title":"Global Spine J"},{"key":"1737_CR32","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/s0021-9290(97)00123-1","volume":"31","author":"JH Keyak","year":"1998","unstructured":"Keyak JH, Rossi SA, Jones KA, Skinner HB. Prediction of femoral fracture load using automated finite element modeling. J Biomech. 1998;31:125\u201333. https:\/\/doi.org\/10.1016\/s0021-9290(97)00123-1.","journal-title":"J Biomech"},{"key":"1737_CR33","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s11914-021-00690-y","volume":"19","author":"GS Lewis","year":"2021","unstructured":"Lewis GS, Mischler D, Wee H, Reid JS, Varga P. Finite element analysis of fracture fixation. Curr Osteoporos Rep. 2021;19:403\u201316. https:\/\/doi.org\/10.1007\/s11914-021-00690-y.","journal-title":"Curr Osteoporos Rep"},{"key":"1737_CR34","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2021.106273","volume":"208","author":"KN Chethan","year":"2021","unstructured":"Chethan KN, Shyamasunder Bhat N, Zuber M, Satish Shenoy B. Finite element analysis of hip implant with varying in taper neck lengths under static loading conditions. Comput Methods Progr Biomed. 2021;208: 106273. https:\/\/doi.org\/10.1016\/j.cmpb.2021.106273.","journal-title":"Comput Methods Progr Biomed"},{"key":"1737_CR35","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1302\/2046-3758.112.Bjr-2021-0282.R1","volume":"11","author":"CH Jung","year":"2022","unstructured":"Jung CH, Cha Y, Yoon HS, Park CH, Yoo JI, Kim JT, Jeon Y. Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture\u202f: a finite element analysis. Bone Joint Rese. 2022;11:102\u201311. https:\/\/doi.org\/10.1302\/2046-3758.112.Bjr-2021-0282.R1.","journal-title":"Bone Joint Rese"},{"key":"1737_CR36","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.jspd.2015.12.008","volume":"4","author":"F Amirouche","year":"2016","unstructured":"Amirouche F, Solitro GF, Magnan BP. Stability and spine pedicle screws fixation strength-a comparative study of bone density and insertion angle. Spine deformity. 2016;4:261\u20137. https:\/\/doi.org\/10.1016\/j.jspd.2015.12.008.","journal-title":"Spine deformity"},{"key":"1737_CR37","doi-asserted-by":"publisher","first-page":"E497","DOI":"10.1097\/bsd.0000000000000130","volume":"30","author":"K Matsukawa","year":"2017","unstructured":"Matsukawa K, Yato Y, Hynes RA, Imabayashi H, Hosogane N, Asazuma T, Matsui T, Kobayashi Y, Nemoto K. Cortical bone trajectory for thoracic pedicle screws: a technical note. Clin Spine Surg. 2017;30:E497-e504. https:\/\/doi.org\/10.1097\/bsd.0000000000000130.","journal-title":"Clin Spine Surg"},{"key":"1737_CR38","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1002\/jor.24235","volume":"37","author":"JWA Fletcher","year":"2019","unstructured":"Fletcher JWA, Windolf M, Richards RG, Gueorguiev B, Buschbaum J, Varga P. Importance of locking plate positioning in proximal humeral fractures as predicted by computer simulations. J Orthop Res. 2019;37:957\u201364. https:\/\/doi.org\/10.1002\/jor.24235.","journal-title":"J Orthop Res"},{"key":"1737_CR39","doi-asserted-by":"publisher","first-page":"1816","DOI":"10.1016\/j.jse.2019.02.013","volume":"28","author":"JWA Fletcher","year":"2019","unstructured":"Fletcher JWA, Windolf M, Richards RG, Gueorguiev B, Varga P. Screw configuration in proximal humerus plating has a significant impact on fixation failure risk predicted by finite element models. J Shoulder Elbow Surg. 2019;28:1816\u201323. https:\/\/doi.org\/10.1016\/j.jse.2019.02.013.","journal-title":"J Shoulder Elbow Surg"},{"key":"1737_CR40","doi-asserted-by":"publisher","first-page":"352","DOI":"10.2106\/00004623-199803000-00007","volume":"80","author":"KJ Koval","year":"1998","unstructured":"Koval KJ, Sala DA, Kummer FJ, Zuckerman JD. Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture. J Bone Joint Surgery Am. 1998;80:352\u20136. https:\/\/doi.org\/10.2106\/00004623-199803000-00007.","journal-title":"J Bone Joint Surgery Am"},{"key":"1737_CR41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jor.2021.05.029","volume":"26","author":"TF Raven","year":"2021","unstructured":"Raven TF, H\u00f6chtl-Lee L, Friedl W, Moghaddam A. Long-term results after over 17 years-Intramedullary gliding nail as treatment for traumatic femoral neck fractures. J Orthop. 2021;26:1\u20137. https:\/\/doi.org\/10.1016\/j.jor.2021.05.029.","journal-title":"J Orthop"}],"container-title":["European Journal of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-024-01737-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40001-024-01737-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-024-01737-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T09:09:22Z","timestamp":1710493762000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurjmedres.biomedcentral.com\/articles\/10.1186\/s40001-024-01737-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,12]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1737"],"URL":"https:\/\/doi.org\/10.1186\/s40001-024-01737-3","relation":{},"ISSN":["2047-783X"],"issn-type":[{"value":"2047-783X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,12]]},"assertion":[{"value":"10 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics Committee of Zigong Fourth People's Hospital declare that the biomedical research involving people completed in our hospital in this paper, the research scheme meets the scientific and ethical requirements (2023\u2013009).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no conflicts of interest to disclose in relation to this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"170"}}