{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T22:55:42Z","timestamp":1793228142807,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T00:00:00Z","timestamp":1738195200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T00:00:00Z","timestamp":1738195200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Plan for Science and Technology Research of Baoding","award":["2041ZF084"],"award-info":[{"award-number":["2041ZF084"]}]},{"name":"Natural Science Foundation of Hebei Province funding project","award":["H2023201903"],"award-info":[{"award-number":["H2023201903"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Med Res"],"DOI":"10.1186\/s40001-025-02317-9","type":"journal-article","created":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T05:38:41Z","timestamp":1738215521000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Agreement of zero-heat-flux thermometry compared with infrared tympanic temperature monitoring in adults undergoing major surgery"],"prefix":"10.1186","volume":"30","author":[{"given":"Jingyan","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Congzhe","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guiyuan","family":"Rong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinfeng","family":"Shao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-5603-0776","authenticated-orcid":false,"given":"Cheng","family":"Ran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,30]]},"reference":[{"issue":"2","key":"2317_CR1","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1097\/ALN.0b013e31817f6d76","volume":"109","author":"DI Sessler","year":"2008","unstructured":"Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology. 2008;109(2):318\u201338. https:\/\/doi.org\/10.1097\/ALN.0b013e31817f6d76.","journal-title":"Anesthesiology"},{"issue":"1","key":"2317_CR2","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/aln.0000000000003481","volume":"134","author":"DI Sessler","year":"2021","unstructured":"Sessler DI. Perioperative temperature monitoring. Anesthesiology. 2021;134(1):111\u20138. https:\/\/doi.org\/10.1097\/aln.0000000000003481.","journal-title":"Anesthesiology"},{"issue":"2","key":"2317_CR3","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1097\/00000542-200002000-00042","volume":"92","author":"DI Sessler","year":"2000","unstructured":"Sessler DI. Perioperative heat balance. Anesthesiology. 2000;92(2):578\u201396. https:\/\/doi.org\/10.1097\/00000542-200002000-00042.","journal-title":"Anesthesiology"},{"issue":"2","key":"2317_CR4","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1097\/00000542-200108000-00040","volume":"95","author":"DI Sessler","year":"2001","unstructured":"Sessler DI. Complications and treatment of mild hypothermia. Anesthesiology. 2001;95(2):531\u201343. https:\/\/doi.org\/10.1097\/00000542-200108000-00040.","journal-title":"Anesthesiology"},{"issue":"1","key":"2317_CR5","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1097\/aln.0000000000000681","volume":"123","author":"AV Scott","year":"2015","unstructured":"Scott AV, Stonemetz JL, Wasey JO, Johnson DJ, Rivers RJ, Koch CG, Frank SM. Compliance with surgical care improvement project for body temperature management (SCIP Inf-10) is associated with improved clinical outcomes. Anesthesiology. 2015;123(1):116\u201325. https:\/\/doi.org\/10.1097\/aln.0000000000000681.","journal-title":"Anesthesiology"},{"issue":"10","key":"2317_CR6","doi-asserted-by":"publisher","first-page":"166","DOI":"10.3238\/arztebl.2015.0166","volume":"112","author":"A Torossian","year":"2015","unstructured":"Torossian A, Br\u00e4uer A, H\u00f6cker J, Bein B, Wulf H, Horn EP. Preventing inadvertent perioperative hypothermia. Deutsches Arzteblatt Int. 2015;112(10):166\u201372. https:\/\/doi.org\/10.3238\/arztebl.2015.0166.","journal-title":"Deutsches Arzteblatt Int"},{"key":"2317_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph182010606","author":"H Hymczak","year":"2021","unstructured":"Hymczak H, Go\u0142\u0105b A, Mendrala K, Plicner D, Darocha T, Podsiad\u0142o P, Hudziak D, Goco\u0142 R, Kosi\u0144ski S. Core temperature measurement-principles of correct measurement, problems, and complications. Int J Environ Res Public Health. 2021. https:\/\/doi.org\/10.3390\/ijerph182010606.","journal-title":"Int J Environ Res Public Health"},{"issue":"6","key":"2317_CR8","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.resuscitation.2012.11.022","volume":"84","author":"D Krizanac","year":"2013","unstructured":"Krizanac D, Stratil P, Hoerburger D, Testori C, Wallmueller C, Schober A, Haugk M, Haller M, Behringer W, Herkner H, et al. Femoro-iliacal artery versus pulmonary artery core temperature measurement during therapeutic hypothermia: an observational study. Resuscitation. 2013;84(6):805\u20139. https:\/\/doi.org\/10.1016\/j.resuscitation.2012.11.022.","journal-title":"Resuscitation"},{"issue":"7","key":"2317_CR9","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1111\/j.1365-2044.1993.tb07127.x","volume":"48","author":"G Edge","year":"1993","unstructured":"Edge G, Morgan M. The genius infrared tympanic thermometer. An evaluation for clinical use. Anaesthesia. 1993;48(7):604\u20137. https:\/\/doi.org\/10.1111\/j.1365-2044.1993.tb07127.x.","journal-title":"Anaesthesia"},{"issue":"4","key":"2317_CR10","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1378\/chest.115.4.1002","volume":"115","author":"Y Amoateng-Adjepong","year":"1999","unstructured":"Amoateng-Adjepong Y, Del Mundo J, Manthous CA. Accuracy of an infrared tympanic thermometer. Chest. 1999;115(4):1002\u20135. https:\/\/doi.org\/10.1378\/chest.115.4.1002.","journal-title":"Chest"},{"issue":"2","key":"2317_CR11","first-page":"8p","volume":"212","author":"RH Fox","year":"1971","unstructured":"Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol. 1971;212(2):8p\u201310p.","journal-title":"J Physiol"},{"issue":"2","key":"2317_CR12","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1007\/s005400300026","volume":"17","author":"M Yamakage","year":"2003","unstructured":"Yamakage M, Namiki A. Deep temperature monitoring using a zero-heat-flow method. J Anesth. 2003;17(2):108\u201315. https:\/\/doi.org\/10.1007\/s005400300026.","journal-title":"J Anesth"},{"key":"2317_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/s22134760","author":"M Aj\u010devi\u0107","year":"2022","unstructured":"Aj\u010devi\u0107 M, Buoite Stella A, Furlanis G, Caruso P, Naccarato M, Accardo A, Manganotti P. A novel non-invasive thermometer for continuous core body temperature: comparison with tympanic temperature in an acute stroke clinical setting. Sensors (Basel, Switzerland). 2022. https:\/\/doi.org\/10.3390\/s22134760.","journal-title":"Sensors (Basel, Switzerland)"},{"issue":"6","key":"2317_CR14","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1177\/17504589211022314","volume":"32","author":"N Kameda","year":"2022","unstructured":"Kameda N. Clinical accuracy of non-contact forehead infrared thermometer and infrared tympanic thermometer in postoperative adult patients: a comparative study. J Perioper Pract. 2022;32(6):142\u20138. https:\/\/doi.org\/10.1177\/17504589211022314.","journal-title":"J Perioper Pract"},{"key":"2317_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-023-01078-2","author":"H Liang","year":"2023","unstructured":"Liang H, Wang JY, Liang Y, Shao XF, Ding YL, Jia HQ. Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery. J Clin Monit Comput. 2023. https:\/\/doi.org\/10.1007\/s10877-023-01078-2.","journal-title":"J Clin Monit Comput"},{"issue":"3","key":"2317_CR16","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1213\/ane.0000000000002706","volume":"126","author":"L Pei","year":"2018","unstructured":"Pei L, Huang Y, Mao G, Sessler DI. Axillary temperature, as recorded by the iThermonitor WT701, well represents core temperature in adults having noncardiac surgery. Anesth Analg. 2018;126(3):833\u20138. https:\/\/doi.org\/10.1213\/ane.0000000000002706.","journal-title":"Anesth Analg"},{"issue":"3","key":"2317_CR17","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1213\/ane.0000000000000319","volume":"119","author":"Y Eshraghi","year":"2014","unstructured":"Eshraghi Y, Nasr V, Parra-Sanchez I, Van Duren A, Botham M, Santoscoy T, Sessler DI. An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients. Anesth Analg. 2014;119(3):543\u20139. https:\/\/doi.org\/10.1213\/ane.0000000000000319.","journal-title":"Anesth Analg"},{"issue":"5","key":"2317_CR18","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1007\/s10877-019-00410-z","volume":"34","author":"E Morettini","year":"2020","unstructured":"Morettini E, Turchini F, Tofani L, Villa G, Ricci Z, Romagnoli S. Intraoperative core temperature monitoring: accuracy and precision of zero-heat flux heated controlled servo sensor compared with esophageal temperature during major surgery; the ESOSPOT study. J Clin Monit Comput. 2020;34(5):1111\u20139. https:\/\/doi.org\/10.1007\/s10877-019-00410-z.","journal-title":"J Clin Monit Comput"},{"issue":"4","key":"2317_CR19","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571\u201382. https:\/\/doi.org\/10.1080\/10543400701329422.","journal-title":"J Biopharm Stat"},{"issue":"3","key":"2317_CR20","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1093\/bja\/aem214","volume":"99","author":"PS Myles","year":"2007","unstructured":"Myles PS, Cui J. I. Using the Bland-Altman method to measure agreement with repeated measures. BJA Br J Anaesth. 2007;99(3):309\u201311. https:\/\/doi.org\/10.1093\/bja\/aem214.","journal-title":"BJA Br J Anaesth"},{"issue":"5","key":"2317_CR21","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1097\/eja.0000000000001322","volume":"38","author":"AJC Mittnacht","year":"2021","unstructured":"Mittnacht AJC, Lin HM, Liu X, Wax D. New-onset intra-operative hyperthermia in a large surgical patient population: a retrospective observational study. Eur J Anaesthesiol. 2021;38(5):487\u201393. https:\/\/doi.org\/10.1097\/eja.0000000000001322.","journal-title":"Eur J Anaesthesiol"},{"issue":"4","key":"2317_CR22","first-page":"303","volume":"91","author":"C Garceau","year":"2023","unstructured":"Garceau C, Cosgrove MS, Gonzalez K. Inadvertent perioperative hypothermia. AANA J. 2023;91(4):303\u20139.","journal-title":"AANA J"},{"key":"2317_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.aucc.2022.08.008","author":"T Ekers","year":"2022","unstructured":"Ekers T, Adamson N, Wells A, Presneill J. A pilot study of agreement between noninvasive thermometers and the core temperature of postoperative cardiothoracic surgical patients. Aust Crit Care. 2022. https:\/\/doi.org\/10.1016\/j.aucc.2022.08.008.","journal-title":"Aust Crit Care"},{"key":"2317_CR24","doi-asserted-by":"publisher","DOI":"10.3390\/biology10121327","author":"AJ Mah","year":"2021","unstructured":"Mah AJ, Ghazi Zadeh L, Khoshnam Tehrani M, Askari S, Gandjbakhche AH. Studying the accuracy and function of different thermometry techniques for measuring body temperature. Biology. 2021. https:\/\/doi.org\/10.3390\/biology10121327.","journal-title":"Biology"},{"issue":"11","key":"2317_CR25","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1097\/jcma.0000000000000770","volume":"85","author":"L Wan","year":"2022","unstructured":"Wan L, Shen PY, Zhang SX, Wang LZ. Agreement of infrared ear temperature with nasopharyngeal temperature and diagnostic performance on hypothermia in general anesthetized patients. J Chin Med Assoc JCMA. 2022;85(11):1093\u20137. https:\/\/doi.org\/10.1097\/jcma.0000000000000770.","journal-title":"J Chin Med Assoc JCMA"},{"issue":"1","key":"2317_CR26","doi-asserted-by":"publisher","first-page":"21746","DOI":"10.1038\/s41598-020-78753-w","volume":"10","author":"A Br\u00e4uer","year":"2020","unstructured":"Br\u00e4uer A, Fazliu A, Perl T, Heise D, Meissner K, Brandes IF. Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients. Sci Rep. 2020;10(1):21746. https:\/\/doi.org\/10.1038\/s41598-020-78753-w.","journal-title":"Sci Rep"},{"issue":"12","key":"2317_CR27","doi-asserted-by":"publisher","first-page":"1299","DOI":"10.1097\/eja.0000000000001492","volume":"38","author":"SY Lee","year":"2021","unstructured":"Lee SY, Bong CL, Siow YN, Allen JC. Tympanic membrane-infrared thermometry against zero heat flux thermometry for detection of postoperative hypothermia in children. Eur J Anaesthesiol. 2021;38(12):1299\u2013302. https:\/\/doi.org\/10.1097\/eja.0000000000001492.","journal-title":"Eur J Anaesthesiol"},{"issue":"5","key":"2317_CR28","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1007\/s10877-021-00758-1","volume":"36","author":"C Verheyden","year":"2022","unstructured":"Verheyden C, Neyrinck A, Laenen A, Rex S, Van Gerven E. Clinical evaluation of a cutaneous zero-heat-flux thermometer during cardiac surgery. J Clin Monit Comput. 2022;36(5):1279\u201387. https:\/\/doi.org\/10.1007\/s10877-021-00758-1.","journal-title":"J Clin Monit Comput"},{"issue":"4","key":"2317_CR29","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1053\/j.jvca.2016.03.141","volume":"30","author":"MT M\u00e4kinen","year":"2016","unstructured":"M\u00e4kinen MT, Pesonen A, Jousela I, P\u00e4iv\u00e4rinta J, Poikaj\u00e4rvi S, Alb\u00e4ck A, Salminen US, Pesonen E. Novel zero-heat-flux deep body temperature measurement in lower extremity vascular and cardiac surgery. J Cardiothorac Vasc Anesth. 2016;30(4):973\u20138. https:\/\/doi.org\/10.1053\/j.jvca.2016.03.141.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"2","key":"2317_CR30","doi-asserted-by":"publisher","first-page":"100","DOI":"10.5152\/tjar.2020.33","volume":"49","author":"H Aksu Erdost","year":"2021","unstructured":"Aksu Erdost H, \u00d6zkarde\u015fler S, De\u011firmenci AK, Dalak RM, Terzi C. Intraoperative temperature monitoring with zero heat flux technology (3M SpotOn Sensor) in comparison with tympanic and oesophageal temperature and hypotermia risk factors: an observational study. Turk J Anaesthesiol Reanim. 2021;49(2):100\u20136. https:\/\/doi.org\/10.5152\/tjar.2020.33.","journal-title":"Turk J Anaesthesiol Reanim"}],"container-title":["European Journal of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02317-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40001-025-02317-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02317-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T05:38:47Z","timestamp":1738215527000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurjmedres.biomedcentral.com\/articles\/10.1186\/s40001-025-02317-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,30]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2317"],"URL":"https:\/\/doi.org\/10.1186\/s40001-025-02317-9","relation":{},"ISSN":["2047-783X"],"issn-type":[{"value":"2047-783X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,30]]},"assertion":[{"value":"29 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the ethics committee of Baoding NO.1 Central Hospital. Written informed consent was obtained from the participating patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"60"}}