{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:21:40Z","timestamp":1787062900431,"version":"build-2736575974"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T00:00:00Z","timestamp":1749686400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T00:00:00Z","timestamp":1749686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Zhejiang Medical Health Science and Technology plan","award":["2022RC068"],"award-info":[{"award-number":["2022RC068"]}]},{"name":"Zhejiang Medical Health Science and Technology plan","award":["2022RC068"],"award-info":[{"award-number":["2022RC068"]}]},{"name":"Zhejiang Medical Health Science and Technology plan","award":["2022RC068"],"award-info":[{"award-number":["2022RC068"]}]},{"name":"Zhejiang Medical Health Science and Technology plan","award":["2022RC068"],"award-info":[{"award-number":["2022RC068"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Med Res"],"DOI":"10.1186\/s40001-025-02747-5","type":"journal-article","created":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T00:18:46Z","timestamp":1749687526000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effect of tibial rotational alignment and posterior slope on joint biomechanics in posterior-stabilized total knee arthroplasty: a finite element study"],"prefix":"10.1186","volume":"30","author":[{"given":"Long","family":"Shao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangdong","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaohua","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongli","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Tao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shicheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,12]]},"reference":[{"issue":"3","key":"2747_CR1","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1016\/j.arth.2022.10.011","volume":"38","author":"MJ DeFrance","year":"2023","unstructured":"DeFrance MJ, Scuderi GR. Are 20% of patients actually dissatisfied following total knee arthroplasty? A systematic review of the literature. J Arthroplasty. 2023;38(3):594\u20139. https:\/\/doi.org\/10.1016\/j.arth.2022.10.011.","journal-title":"J Arthroplasty"},{"issue":"9","key":"2747_CR2","doi-asserted-by":"publisher","first-page":"3168","DOI":"10.1016\/j.arth.2021.05.001","volume":"36","author":"S Rashed","year":"2021","unstructured":"Rashed S, Lakhani S, Mann A, Best LMJ, Shehzad S, Saeed MZ. The impact of the largest national joint registry on current knee replacement longevity estimates: an analysis and review of knee prosthesis brand and fixation technique. J Arthroplasty. 2021;36(9):3168-3173.e1. https:\/\/doi.org\/10.1016\/j.arth.2021.05.001.","journal-title":"J Arthroplasty"},{"issue":"12","key":"2747_CR3","doi-asserted-by":"publisher","first-page":"3854","DOI":"10.1016\/j.arth.2017.07.021","volume":"32","author":"R Gunaratne","year":"2017","unstructured":"Gunaratne R, Pratt DN, Banda J, Fick DP, Khan RJK, Robertson BW. Patient dissatisfaction following total knee arthroplasty: a systematic review of the literature. J Arthroplasty. 2017;32(12):3854\u201360. https:\/\/doi.org\/10.1016\/j.arth.2017.07.021.","journal-title":"J Arthroplasty"},{"issue":"8","key":"2747_CR4","doi-asserted-by":"publisher","first-page":"303","DOI":"10.47102\/annals-acadmedsg.V46N8p303","volume":"46","author":"Y Huang","year":"2017","unstructured":"Huang Y, Lee M, Chong HC, Ning Y, Lo NN, Yeo SJ. Reasons and factors behind post-total knee arthroplasty dissatisfaction in an asian population. Ann Acad Med Singap. 2017;46(8):303\u20139.","journal-title":"Ann Acad Med Singap"},{"issue":"11","key":"2747_CR5","doi-asserted-by":"publisher","first-page":"2751","DOI":"10.1007\/s11999-008-0452-8","volume":"466","author":"P Aglietti","year":"2008","unstructured":"Aglietti P, Sensi L, Cuomo P, Ciardullo A. Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res. 2008;466(11):2751\u20135. https:\/\/doi.org\/10.1007\/s11999-008-0452-8.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"2747_CR6","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1302\/0301-620X.89B1.17728","volume":"89","author":"M Ikeuchi","year":"2007","unstructured":"Ikeuchi M, Yamanaka N, Okanoue Y, Ueta E, Tani T. Determining the rotational alignment of the tibial component at total knee replacement: a comparison of two techniques. J Bone Joint Surg Br. 2007;89(1):45\u20139. https:\/\/doi.org\/10.1302\/0301-620X.89B1.17728.","journal-title":"J Bone Joint Surg Br"},{"key":"2747_CR7","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/00003086-200108000-00021","volume":"389","author":"DF Dalury","year":"2001","unstructured":"Dalury DF. Observations of the proximal tibia in total knee arthroplasty. Clin Orthop Relat Res. 2001;389:150\u20135. https:\/\/doi.org\/10.1097\/00003086-200108000-00021.","journal-title":"Clin Orthop Relat Res"},{"key":"2747_CR8","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/00003086-200403000-00030","volume":"420","author":"M Akagi","year":"2004","unstructured":"Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C. An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res. 2004;420:213\u20139. https:\/\/doi.org\/10.1097\/00003086-200403000-00030.","journal-title":"Clin Orthop Relat Res"},{"key":"2747_CR9","first-page":"405","volume":"55","author":"J Benjamin","year":"2006","unstructured":"Benjamin J. Component alignment in total knee arthroplasty. Instr Course Lect. 2006;55:405\u201312.","journal-title":"Instr Course Lect"},{"issue":"12","key":"2747_CR10","doi-asserted-by":"publisher","first-page":"2473","DOI":"10.1007\/s00264-012-1675-6","volume":"36","author":"A Sternheim","year":"2012","unstructured":"Sternheim A, Lochab J, Drexler M, et al. The benefit of revision knee arthroplasty for component malrotation after primary total knee replacement. Int Orthop. 2012;36(12):2473\u20138. https:\/\/doi.org\/10.1007\/s00264-012-1675-6.","journal-title":"Int Orthop"},{"issue":"6","key":"2747_CR11","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.1007\/s00167-017-4823-0","volume":"26","author":"AS Panni","year":"2018","unstructured":"Panni AS, Ascione F, Rossini M, et al. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2018;26(6):1636\u201344. https:\/\/doi.org\/10.1007\/s00167-017-4823-0.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"2747_CR12","doi-asserted-by":"publisher","first-page":"10529","DOI":"10.1038\/s41598-020-67613-2","volume":"10","author":"L Shao","year":"2020","unstructured":"Shao L, Wu XD, Wang T, et al. Approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation. Sci Rep. 2020;10(1):10529. https:\/\/doi.org\/10.1038\/s41598-020-67613-2.","journal-title":"Sci Rep"},{"issue":"5","key":"2747_CR13","doi-asserted-by":"publisher","first-page":"480","DOI":"10.3109\/17453674.2014.940573","volume":"85","author":"K Gromov","year":"2014","unstructured":"Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A. What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop. 2014;85(5):480\u20137. https:\/\/doi.org\/10.3109\/17453674.2014.940573.","journal-title":"Acta Orthop"},{"issue":"1","key":"2747_CR14","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s42836-021-00085-5","volume":"3","author":"S Takemura","year":"2021","unstructured":"Takemura S, Ikawa T, Ohyama Y, et al. The posterior tibial slope does not influence the flexion angle in posterior-stabilized mobile-bearing total knee arthroplasty. Arthroplasty. 2021;3(1):28. https:\/\/doi.org\/10.1186\/s42836-021-00085-5.","journal-title":"Arthroplasty"},{"issue":"1","key":"2747_CR15","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1055\/s-0038-1676564","volume":"33","author":"L Shao","year":"2020","unstructured":"Shao L, Wang T, Liao J, Xu W, Liang X, Huang W. Effect of tibial component alignment and posterior slope on tibial coverage in a chinese population: a three-dimensional anthropometric study. J Knee Surg. 2020;33(1):53\u201361. https:\/\/doi.org\/10.1055\/s-0038-1676564.","journal-title":"J Knee Surg"},{"issue":"5","key":"2747_CR16","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.1007\/s00167-017-4561-3","volume":"26","author":"MA Marra","year":"2018","unstructured":"Marra MA, Strzelczak M, Heesterbeek PJC, et al. Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics: a musculoskeletal simulation study. Knee Surg Sports Traumatol Arthrosc. 2018;26(5):1540\u20138. https:\/\/doi.org\/10.1007\/s00167-017-4561-3.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"8","key":"2747_CR17","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1016\/j.arth.2015.02.042","volume":"30","author":"S Okamoto","year":"2015","unstructured":"Okamoto S, Mizu-uchi H, Okazaki K, Hamai S, Nakahara H, Iwamoto Y. Effect of tibial posterior slope on knee kinematics, quadriceps force, and patellofemoral contact force after posterior-stabilized total knee arthroplasty. J Arthroplasty. 2015;30(8):1439\u201343. https:\/\/doi.org\/10.1016\/j.arth.2015.02.042.","journal-title":"J Arthroplasty"},{"issue":"10","key":"2747_CR18","doi-asserted-by":"publisher","first-page":"3188","DOI":"10.1007\/s00167-018-4925-3","volume":"26","author":"KT Kang","year":"2018","unstructured":"Kang KT, Kwon SK, Son J, Kwon OR, Lee JS, Koh YG. The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2018;26(10):3188\u201395. https:\/\/doi.org\/10.1007\/s00167-018-4925-3.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2747_CR19","doi-asserted-by":"publisher","first-page":"4908639","DOI":"10.1155\/2017\/4908639","volume":"2017","author":"KT Kang","year":"2017","unstructured":"Kang KT, Koh YG, Son J, Kwon OR, Lee JS, Kwon SK. Biomechanical effects of posterior condylar offset and posterior tibial slope on quadriceps force and joint contact forces in posterior-stabilized total knee arthroplasty. Biomed Res Int. 2017;2017:4908639. https:\/\/doi.org\/10.1155\/2017\/4908639.","journal-title":"Biomed Res Int"},{"issue":"1","key":"2747_CR20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1302\/2046-3758.71.BJR-2017-0143.R1","volume":"7","author":"KT Kang","year":"2018","unstructured":"Kang KT, Koh YG, Son J, Kwon OR, Lee JS, Kwon SK. A computational simulation study to determine the biomechanical influence of posterior condylar offset and tibial slope in cruciate retaining total knee arthroplasty. Bone Joint Res. 2018;7(1):69\u201378. https:\/\/doi.org\/10.1302\/2046-3758.71.BJR-2017-0143.R1.","journal-title":"Bone Joint Res"},{"issue":"1","key":"2747_CR21","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1186\/s13018-022-03037-0","volume":"17","author":"P Ma","year":"2022","unstructured":"Ma P, Muheremu A, Zhang S, Zheng Q, Wang W, Jiang K. Biomechanical effects of fixed-bearing femoral prostheses with different coronal positions in medial unicompartmental knee arthroplasty. J Orthop Surg Res. 2022;17(1):150. https:\/\/doi.org\/10.1186\/s13018-022-03037-0.","journal-title":"J Orthop Surg Res"},{"key":"2747_CR22","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/00003086-200111000-00006","volume":"392","author":"RL Barrack","year":"2001","unstructured":"Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L. Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res. 2001;392:46\u201355. https:\/\/doi.org\/10.1097\/00003086-200111000-00006.","journal-title":"Clin Orthop Relat Res"},{"key":"2747_CR23","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1097\/00003086-199811000-00021","volume":"356","author":"RA Berger","year":"1998","unstructured":"Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144\u201353. https:\/\/doi.org\/10.1097\/00003086-199811000-00021.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"2747_CR24","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/s0883-5403(03)00197-9","volume":"18","author":"SJ Incavo","year":"2003","unstructured":"Incavo SJ, Coughlin KM, Pappas C, Beynnon BD. Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty. J Arthroplasty. 2003;18(5):643\u20138. https:\/\/doi.org\/10.1016\/s0883-5403(03)00197-9.","journal-title":"J Arthroplasty"},{"key":"2747_CR25","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1097\/01.blo.0000160027.52481.32","volume":"436","author":"M Akagi","year":"2005","unstructured":"Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C. Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res. 2005;436:172\u20136. https:\/\/doi.org\/10.1097\/01.blo.0000160027.52481.32.","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"2747_CR26","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/j.arth.2010.03.015","volume":"26","author":"MP Bonnin","year":"2011","unstructured":"Bonnin MP, Saffarini M, Mercier PE, Laurent JR, Carrillon Y. Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty? J Arthroplasty. 2011;26(2):260-7.e72. https:\/\/doi.org\/10.1016\/j.arth.2010.03.015.","journal-title":"J Arthroplasty"},{"issue":"1","key":"2747_CR27","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1186\/s12891-017-1609-y","volume":"18","author":"JI Kim","year":"2017","unstructured":"Kim JI, Jang J, Lee KW, Han HS, Lee S, Lee MC. Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty. BMC Musculoskelet Disord. 2017;18(1):252. https:\/\/doi.org\/10.1186\/s12891-017-1609-y.","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"2747_CR28","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1002\/jor.23279","volume":"35","author":"OR Kwon","year":"2017","unstructured":"Kwon OR, Kang KT, Son J, Suh DS, Baek C, Koh YG. Importance of joint line preservation in unicompartmental knee arthroplasty: finite element analysis. J Orthop Res. 2017;35(2):347\u201352. https:\/\/doi.org\/10.1002\/jor.23279.","journal-title":"J Orthop Res"},{"issue":"2","key":"2747_CR29","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/s0021-9290(01)00179-8","volume":"35","author":"AC Godest","year":"2002","unstructured":"Godest AC, Beaugonin M, Haug E, Taylor M, Gregson PJ. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J Biomech. 2002;35(2):267\u201375. https:\/\/doi.org\/10.1016\/s0021-9290(01)00179-8.","journal-title":"J Biomech"},{"issue":"8","key":"2747_CR30","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.joca.2009.02.012","volume":"17","author":"L McCann","year":"2009","unstructured":"McCann L, Ingham E, Jin Z, Fisher J. Influence of the meniscus on friction and degradation of cartilage in the natural knee joint. Osteoarthritis Cartilage. 2009;17(8):995\u20131000. https:\/\/doi.org\/10.1016\/j.joca.2009.02.012.","journal-title":"Osteoarthritis Cartilage"},{"issue":"2","key":"2747_CR31","doi-asserted-by":"publisher","first-page":"91","DOI":"10.5792\/ksrr.2012.24.2.91","volume":"24","author":"HY Lee","year":"2012","unstructured":"Lee HY, Kim SJ, Kang KT, Kim SH, Park KK. The effect of tibial posterior slope on contact force and ligaments stresses in posterior-stabilized total knee arthroplasty-explicit finite element analysis. Knee Surg Relat Res. 2012;24(2):91\u20138. https:\/\/doi.org\/10.5792\/ksrr.2012.24.2.91.","journal-title":"Knee Surg Relat Res"},{"issue":"11","key":"2747_CR32","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.3928\/0147-7447-20011101-13","volume":"24","author":"DF Bindelglass","year":"2001","unstructured":"Bindelglass DF. Rotational alignment of the tibial component in total knee arthroplasty. Orthopedics. 2001;24(11):1049\u201352. https:\/\/doi.org\/10.3928\/0147-7447-20011101-13.","journal-title":"Orthopedics"},{"issue":"4","key":"2747_CR33","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.2106\/JBJS.RVW.O.00057","volume":"4","author":"R Ahmad","year":"2016","unstructured":"Ahmad R, Patel A, Mandalia V, Toms A. Posterior tibial slope: effect on, and interaction with, knee kinematics. JBJS Rev. 2016;4(4):e31\u20136. https:\/\/doi.org\/10.2106\/JBJS.RVW.O.00057.","journal-title":"JBJS Rev"},{"issue":"12","key":"2747_CR34","doi-asserted-by":"publisher","first-page":"2696","DOI":"10.1007\/s00167-012-2058-7","volume":"21","author":"X Shi","year":"2013","unstructured":"Shi X, Shen B, Kang P, Yang J, Zhou Z, Pei F. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2013;21(12):2696\u2013703. https:\/\/doi.org\/10.1007\/s00167-012-2058-7.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"2747_CR35","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.knee.2018.02.001","volume":"25","author":"HS Han","year":"2018","unstructured":"Han HS, Kang SB. Interactive effect of femoral posterior condylar offset and tibial posterior slope on knee flexion in posterior cruciate ligament-substituting total knee arthroplasty. Knee. 2018;25(2):335\u201340. https:\/\/doi.org\/10.1016\/j.knee.2018.02.001.","journal-title":"Knee"},{"issue":"9","key":"2747_CR36","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1302\/0301-620X.92B9.23516","volume":"92","author":"D Nicoll","year":"2010","unstructured":"Nicoll D, Rowley DI. Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br. 2010;92(9):1238\u201344. https:\/\/doi.org\/10.1302\/0301-620X.92B9.23516.","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"2747_CR37","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00264-013-2097-9","volume":"38","author":"YH Kim","year":"2014","unstructured":"Kim YH, Park JW, Kim JS, Park SD. The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop. 2014;38(2):379\u201385. https:\/\/doi.org\/10.1007\/s00264-013-2097-9.","journal-title":"Int Orthop"},{"issue":"11","key":"2747_CR38","doi-asserted-by":"publisher","first-page":"3330","DOI":"10.1007\/s00167-014-3144-9","volume":"23","author":"Y Shen","year":"2015","unstructured":"Shen Y, Li X, Fu X, Wang W. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope. Knee Surg Sports Traumatol Arthrosc. 2015;23(11):3330\u20136. https:\/\/doi.org\/10.1007\/s00167-014-3144-9.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"2747_CR39","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.orthres.2004.09.005","volume":"23","author":"G Li","year":"2005","unstructured":"Li G, Papannagari R, Most E, et al. Anterior tibial post impingement in a posterior stabilized total knee arthroplasty. J Orthop Res. 2005;23(3):536\u201341. https:\/\/doi.org\/10.1016\/j.orthres.2004.09.005.","journal-title":"J Orthop Res"},{"issue":"4","key":"2747_CR40","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.knee.2018.04.012","volume":"25","author":"M Krause","year":"2018","unstructured":"Krause M, Hubert J, Deymann S, et al. Bone microarchitecture of the tibial plateau in skeletal health and osteoporosis. Knee. 2018;25(4):559\u201367. https:\/\/doi.org\/10.1016\/j.knee.2018.04.012.","journal-title":"Knee"},{"issue":"1","key":"2747_CR41","doi-asserted-by":"publisher","first-page":"12319","DOI":"10.1038\/s41598-022-15759-6","volume":"12","author":"H Mizu-Uchi","year":"2022","unstructured":"Mizu-Uchi H, Ma Y, Ishibashi S, Colwell CW Jr, Nakashima Y, D\u2019Lima DD. Tibial sagittal and rotational alignment reduce patellofemoral stresses in posterior stabilized total knee arthroplasty. Sci Rep. 2022;12(1):12319. https:\/\/doi.org\/10.1038\/s41598-022-15759-6.","journal-title":"Sci Rep"},{"key":"2747_CR42","doi-asserted-by":"publisher","first-page":"1352794","DOI":"10.3389\/fbioe.2024.1352794","volume":"12","author":"N Guo","year":"2024","unstructured":"Guo N, Smith CR, Sch\u00fctz P, et al. Posterior tibial slope influences joint mechanics and soft tissue loading after total knee arthroplasty. Front Bioeng Biotechnol. 2024;12:1352794. https:\/\/doi.org\/10.3389\/fbioe.2024.1352794.","journal-title":"Front Bioeng Biotechnol."}],"container-title":["European Journal of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02747-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40001-025-02747-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02747-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T00:18:50Z","timestamp":1749687530000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurjmedres.biomedcentral.com\/articles\/10.1186\/s40001-025-02747-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,12]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2747"],"URL":"https:\/\/doi.org\/10.1186\/s40001-025-02747-5","relation":{},"ISSN":["2047-783X"],"issn-type":[{"value":"2047-783X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,12]]},"assertion":[{"value":"19 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee of Ningbo No.6 Hospital (No. K2021074). All methods were performed in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from participants for the publication of any potentially identifiable data included in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"476"}}