{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T10:26:44Z","timestamp":1769077604831,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T00:00:00Z","timestamp":1750636800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T00:00:00Z","timestamp":1750636800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010814","name":"Anhui Provincial Department of Education","doi-asserted-by":"publisher","award":["ZR2022B001"],"award-info":[{"award-number":["ZR2022B001"]}],"id":[{"id":"10.13039\/501100010814","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Med Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>To compare the biomechanical characteristics of thoracolumbar fractures treated with uniplanar screws, monoaxial screws, and polyaxial screws using finite element analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>CT data of the thoracolumbar spine T<jats:sub>12<\/jats:sub>\u2013L<jats:sub>2<\/jats:sub> from a healthy volunteer were collected, and using finite element software, models of both normal and fractured spines were created. Three different fixation models were constructed with monoaxial screws (Mps group), polyaxial screws (Pps group), and uniplanar screws (Ups group), respectively. The L<jats:sub>2<\/jats:sub> vertebra was fixed and a compressive load of 150 N and a torque of 10 N\u2022m were applied at the T<jats:sub>12<\/jats:sub> end to simulate flexion, extension, lateral bending, and rotation movements of the spine. The range of motion (ROM) and internal fixation stress within the screws and rods were recorded for each movement direction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A finite element model of the healthy human spine T<jats:sub>12<\/jats:sub>\u2013L<jats:sub>2<\/jats:sub> was established and validated for accuracy. All three fixation models demonstrated decreased ROM in all tested movements. The UPS group showed the lowest percentage of ROM in flexion, extension, and lateral bending movements, with a mid-range percentage of ROM in rotation, and relatively the best stability. The PPS group had the highest ROM percentages in all directions of movement, with the worst relative stability. The maximum von Mises stress for pedicle screws and rods in all fixation modes occurred in flexion, with the MPS group\u2019s screws showing significantly higher stress peaks in flexion and both rotations than those of the PPS and UPS groups. The rods of the PPS group had significantly lower stress peaks in all motion states compared to those of the MPS and UPS groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Uniplanar screws can effectively distribute stress, reduce the risk of screw and rod breakage, and ensure stability of spinal fixation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40001-025-02785-z","type":"journal-article","created":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T06:50:49Z","timestamp":1750661449000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Finite element analysis of percutaneous uniplanar screw fixation in the treatment of thoracolumbar fractures"],"prefix":"10.1186","volume":"30","author":[{"given":"Shen","family":"Cao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Xuan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chengbao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yubing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,23]]},"reference":[{"key":"2785_CR1","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1007\/s0010140-005-0457-5","volume":"12","author":"FV Bensch","year":"2006","unstructured":"Bensch FV, Koivikko MP, Kiuru MJ, Koskinen SK. The incidence and distribution of burst fractures. Emerg Radiol. 2006;12:124\u20139.","journal-title":"Emerg Radiol"},{"key":"2785_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuchi.2023.101457","volume":"69","author":"B Nathan","year":"2023","unstructured":"Nathan B, Ibrahima T, Arnaud D. Single midline skin incision for long segment posterior percutaneous pedicle screw fixation. Neurochirurgie. 2023;69: 101457.","journal-title":"Neurochirurgie"},{"key":"2785_CR3","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1016\/j.wneu.2020.05.071","volume":"140","author":"AA Momin","year":"2020","unstructured":"Momin AA, Steinmetz MP. Evolution of minimally invasive lumbar spine surgery. World Neurosurg. 2020;140:622\u20136.","journal-title":"World Neurosurg"},{"key":"2785_CR4","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1007\/s00590-018-2122-1","volume":"28","author":"G Caruso","year":"2018","unstructured":"Caruso G, Lombardi E, Andreotti M, Lorusso V, Gildone A, Padovani S, Massari L. Minimally invasive fixation techniques for thoracolumbar fractures: comparison between percutaneous pedicle screw with PPSIS and PPSK. Eur J Orthop Surg Traumatol. 2018;28:849\u201358.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2785_CR5","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000011560","volume":"97","author":"Q Zhao","year":"2018","unstructured":"Zhao Q, Zhang H, Hao D, Guo H, Wang B, He B. Complications of percutaneous pedicle screw fixation in treating thoracolumbar and lumbar fracture. Medicine. 2018;97: e11560.","journal-title":"Medicine"},{"key":"2785_CR6","doi-asserted-by":"publisher","first-page":"933","DOI":"10.3390\/jcm14030933","volume":"31","author":"R Viola","year":"2025","unstructured":"Viola R, Juh\u00e1sz \u00c1, S\u00fcvegh D, Veres DS, Gati A, Viola \u00c1, Al-Smadi MW. Impact of treatment modalities and fracture stability on survival in thoracolumbar fractures: a 5-year observational study. J Clin Med. 2025;31:933.","journal-title":"J Clin Med"},{"key":"2785_CR7","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1111\/os.12643","volume":"12","author":"TN Wang","year":"2022","unstructured":"Wang TN, Wu BL, Duan RM, Yuan YS, Qu MG, Zhang S, Huang W, Liu T, Yu XB. Treatment of thoracolumbar fractures through different short segment pedicle screw fixation techniques: a finite element analysis. Orthop Surg. 2022;12:601\u20138.","journal-title":"Orthop Surg"},{"key":"2785_CR8","first-page":"802","volume":"34","author":"K Paksoy","year":"2024","unstructured":"Paksoy K, Avci I, Abdioglu AA, Senturk S, Yaman O. Finite element analysis of bilateral double rod constructs in thoracolumbar fractures. Turk Neurosurg. 2024;34:802\u20138.","journal-title":"Turk Neurosurg"},{"key":"2785_CR9","doi-asserted-by":"publisher","first-page":"6356","DOI":"10.1021\/acsbiomaterials.0c01096","volume":"6","author":"T Liu","year":"2020","unstructured":"Liu T, Chen Y, Apicella A, Mu Z, Yu T, Huang Y, Wang C. Effect of porous microstructures on the biomechanical characteristics of a root analogue implant: an animal study and a finite element analysis. ACS Biomater Sci Eng. 2020;6:6356\u201367.","journal-title":"ACS Biomater Sci Eng"},{"key":"2785_CR10","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s40001-022-00769-x","volume":"27","author":"J Yan","year":"2022","unstructured":"Yan J, Liao Z, Yu Y. Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture. Eur J Med Res. 2022;27:142.","journal-title":"Eur J Med Res"},{"key":"2785_CR11","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1080\/10255842.2023.2243360","volume":"27","author":"C Xu","year":"2024","unstructured":"Xu C, Bai X, Ruan D, Zhang C. Comparative finite element analysis of posterior short segment fixation constructs with or without intermediate screws in the fractured vertebrae for the treatment of type a thoracolumbar fracture. Comput Methods Biomech Biomed Engin. 2024;27:1398\u2013409.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"2785_CR12","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0099156","volume":"9","author":"CQ Li","year":"2014","unstructured":"Li CQ, Zhou Y, Wang HW, Liu J, Xiang LB. Treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis. PLoS ONE. 2014;9: e99156.","journal-title":"PLoS ONE"},{"key":"2785_CR13","volume":"25","author":"H Sonja","year":"2024","unstructured":"Sonja H, Martin N, Benjamin M, Valentin N, Christoph E. Study protocol for a randomized controlled clinical trial on the outcome of surgical versus primary nonsurgical treatment of traumatic thoracolumbar spine burst fractures in patients without neurological symptoms-A34RCT. Neurosurg Pract. 2024;25: e00091.","journal-title":"Neurosurg Pract"},{"key":"2785_CR14","first-page":"407","volume":"34","author":"Q Liu","year":"2024","unstructured":"Liu Q, Jiang J, Huang L, Liu X, Li A, Zhou J. Comparison clinical outcomes of posterior short segment transpedicular fixation with or without injured vertebra fixation in thoracolumbar burst fracture: a retrospective study. Turk Neurosurg. 2024;34:407\u201314.","journal-title":"Turk Neurosurg"},{"key":"2785_CR15","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.spinee.2023.10.019","volume":"24","author":"T Tannoury","year":"2024","unstructured":"Tannoury T, Seo HH, Saade A, Chahine MN, Atallah B, Tannoury C. Evaluating the safe zone for lumbar pedicle screws: are midline crossing screws indicative of pedicle breach? Spine J. 2024;24:617\u201324.","journal-title":"Spine J"},{"key":"2785_CR16","doi-asserted-by":"publisher","first-page":"30","DOI":"10.37796\/2211-8039.1016","volume":"10","author":"XL Chong","year":"2020","unstructured":"Chong XL, Kumar A, Yang EWR, Kaliya-Perumal AK, Oh JY. Incidence of pedicle breach following open and minimally invasive spinal instrumentation. Biomedicine. 2020;10:30\u20135.","journal-title":"Biomedicine"},{"key":"2785_CR17","doi-asserted-by":"publisher","first-page":"e423","DOI":"10.1016\/j.wneu.2024.09.116","volume":"192","author":"Y Wang","year":"2024","unstructured":"Wang Y, Li G, Hu X, Xu N, Ma W. Influence of screw length and cement position within the injured vertebra on fixation strength in short-segment fixation of osteoporotic thoracolumbar burst fractures. World Neurosurg. 2024;192:e423\u201334.","journal-title":"World Neurosurg"},{"issue":"4","key":"2785_CR18","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/j.injury.2020.10.014","volume":"52","author":"S Ding","year":"2021","unstructured":"Ding S, Lu X, Liu Z, Wang Y. Reduce the fractured central endplate in thoracolumbar fractures using percutaneous pedicle screws and instrumentational maneuvers: technical strategy and radiological outcomes. Injury. 2021;52(4):1060\u20134.","journal-title":"Injury"},{"key":"2785_CR19","doi-asserted-by":"publisher","first-page":"1268557","DOI":"10.3389\/fbioe.2023.1268557","volume":"11","author":"G Zhang","year":"2023","unstructured":"Zhang G, Du Y, Jiang G, Kong W, Li J, Zhu Z, Xi Y. Biomechanical evaluation of different posterior fixation techniques for treating thoracolumbar burst fractures of osteoporosis old patients: a finite element analysis. Front Bioeng Biotechnol. 2023;11:1268557.","journal-title":"Front Bioeng Biotechnol"}],"container-title":["European Journal of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02785-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40001-025-02785-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40001-025-02785-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T19:02:16Z","timestamp":1750705336000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurjmedres.biomedcentral.com\/articles\/10.1186\/s40001-025-02785-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,23]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2785"],"URL":"https:\/\/doi.org\/10.1186\/s40001-025-02785-z","relation":{},"ISSN":["2047-783X"],"issn-type":[{"value":"2047-783X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,23]]},"assertion":[{"value":"1 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"514"}}