{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T03:30:38Z","timestamp":1762918238951,"version":"3.37.3"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004396","name":"Thailand Research Fund","doi-asserted-by":"publisher","award":["RDG5750069","MRG5080347"],"award-info":[{"award-number":["RDG5750069","MRG5080347"]}],"id":[{"id":"10.13039\/501100004396","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Prog Orthod."],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The purpose of this study was to compare the stress distribution and displacement patterns of the one versus two maxillary molars distalization with iPanda and to evaluate the biomechanical effect of distalization on the iPanda using the finite element method.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The finite element models of a maxillary arch with complete dentition, periodontal ligament, palatal and alveolar bone, and an iPanda connected to a pair of midpalatal miniscrews were created. Two models were created to simulate maxillary molar distalization. In the first model, the iPanda was connected to the second molar to simulate a single molar distalization. In the second model, the iPanda was connected to the first molar to simulate \u201cen-masse\u201d first and second molar distalization. A varying force from 50 to 200 g was applied. The stress distribution and displacement patterns were analyzed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>For one molar, the stress was concentrated at the furcation and along the distal surface in all roots with a large amount of distalization and distobuccal crown tipping. For two molars, the stress in the first molar was 10 times higher than in the second molar with a great tendency for buccal tipping and a minimal amount of distalization. Moreover, the stress concentration on the distal miniscrew was six times higher than in the mesial miniscrew with an extrusive and intrusive vector, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Individual molar distalization provides the most effective stress distribution and displacement patterns with reduced force levels. In contrast, the en-masse distalization of two molars results in increased force levels with undesirable effects in the transverse and vertical direction.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40510-021-00356-6","type":"journal-article","created":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T14:54:51Z","timestamp":1620053691000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of one versus two maxillary molars distalization with iPanda: a finite element analysis"],"prefix":"10.1186","volume":"22","author":[{"given":"Kamontip","family":"Sujaritwanid","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boonsiva","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8185-9965","authenticated-orcid":false,"given":"Eduardo Yugo","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,5,3]]},"reference":[{"issue":"4","key":"356_CR1","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1016\/j.ajodo.2006.08.012","volume":"131","author":"SA Escobar","year":"2007","unstructured":"Escobar SA, Tellez PA, Moncada CA, Villegas CA, Latorre CM, Oberti G. Distalization of maxillary molars with the bone-supported pendulum: a clinical study. Am J Orthod Dentofac Orthop. 2007;131(4):545\u20139. https:\/\/doi.org\/10.1016\/j.ajodo.2006.08.012.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"4","key":"356_CR2","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.ajodo.2007.10.049","volume":"136","author":"GS Kinzinger","year":"2009","unstructured":"Kinzinger GS, G\u00fclden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofac Orthop. 2009;136(4):578\u201386. https:\/\/doi.org\/10.1016\/j.ajodo.2007.10.049.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"5","key":"356_CR3","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1043\/0003-3219(2002)072<0481:EOMMDW>2.0.CO;2","volume":"72","author":"E Bolla","year":"2002","unstructured":"Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod. 2002;72(5):481\u201394. https:\/\/doi.org\/10.1043\/0003-3219(2002)072<0481:EOMMDW>2.0.CO;2.","journal-title":"Angle Orthod"},{"issue":"4","key":"356_CR4","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.ajodo.2004.12.031","volume":"130","author":"A Fuziy","year":"2006","unstructured":"Fuziy A, de Almeida RR, Janson G, Angelieri F, Pinzan A. Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofac Orthop. 2006;130(4):502\u201310. https:\/\/doi.org\/10.1016\/j.ajodo.2004.12.031.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"2","key":"356_CR5","first-page":"129","volume":"15","author":"FK Byloff","year":"2000","unstructured":"Byloff FK, K\u00e4rcher H, Clar E, Stoff F. An implant to eliminate anchorage loss during molar distalization: a case report involving the Graz implant-supported pendulum. Int J Adult Orthodon Orthognath Surg. 2000;15(2):129\u201337.","journal-title":"Int J Adult Orthodon Orthognath Surg"},{"issue":"1","key":"356_CR6","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ajodo.2003.02.002","volume":"125","author":"GS Kinzinger","year":"2004","unstructured":"Kinzinger GS, Fritz UB, Sander FG, Diedrich PR. Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofac Orthop. 2004;125(1):8\u201323. https:\/\/doi.org\/10.1016\/j.ajodo.2003.02.002.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"2","key":"356_CR7","first-page":"80","volume":"50","author":"EY Suzuki","year":"2016","unstructured":"Suzuki EY, Suzuki B. The indirect palatal miniscrew anchorage and distalization appliance. J Clin Orthod. 2016;50(2):80\u201396.","journal-title":"J Clin Orthod"},{"issue":"1","key":"356_CR8","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1053\/j.sodo.2004.11.008","volume":"11","author":"J Sugawara","year":"2005","unstructured":"Sugawara J, Nishimura M. Minibone plates: the skeletal anchorage system. Semin Orthod. 2005;11(1):47\u201356. https:\/\/doi.org\/10.1053\/j.sodo.2004.11.008.","journal-title":"Semin Orthod"},{"issue":"2","key":"356_CR9","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.ajodo.2003.02.003","volume":"125","author":"J Sugawara","year":"2004","unstructured":"Sugawara J, Daimaruya T, Umemori M, Nagasaka H, Takahashi I, Kawamura H, et al. Distal movement of mandibular molars in adult patients with the skeletal anchorage system. Am J Orthod Dentofac Orthop. 2004;125(2):130\u20138. https:\/\/doi.org\/10.1016\/j.ajodo.2003.02.003.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"356_CR10","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.ajodo.2014.03.023","volume":"146","author":"YA Kook","year":"2014","unstructured":"Kook YA, Bayome M, Trang VT, Kim HJ, Park JH, Kim KB, et al. Treatment effects of a modified palatal anchorage plate for distalization evaluated with cone-beam computed tomography. Am J Orthod Dentofac Orthop. 2014;146(1):47\u201354. https:\/\/doi.org\/10.1016\/j.ajodo.2014.03.023.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"5","key":"356_CR11","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1016\/j.ajodo.2012.11.024","volume":"143","author":"RH Grec","year":"2013","unstructured":"Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofac Orthop. 2013;143(5):602\u201315. https:\/\/doi.org\/10.1016\/j.ajodo.2012.11.024.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"3","key":"356_CR12","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.ajodo.2016.08.029","volume":"151","author":"SJ Antoszewska","year":"2017","unstructured":"Antoszewska SJ, Sarul M, \u0141yczek J, Konopka T, Kawala B. Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during en-masse retraction: a systematic review and meta-analysis. Am J Orthod Dentofac Orthop. 2017;151(3):440\u201355. https:\/\/doi.org\/10.1016\/j.ajodo.2016.08.029.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"356_CR13","doi-asserted-by":"publisher","first-page":"e228","DOI":"10.11607\/ortho.982","volume":"14","author":"EY Suzuki","year":"2013","unstructured":"Suzuki EY, Suzuki B. Maxillary molar distalization with the Indirect Palatal Miniscrew for Anchorage and Distalization Appliance (iPANDA). Orthodontics (Chic). 2013;14(1):e228\u2013e41. https:\/\/doi.org\/10.11607\/ortho.982.","journal-title":"Orthodontics (Chic)"},{"issue":"2","key":"356_CR14","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1590\/2176-9451.20.2.119-125.sar","volume":"20","author":"L Knop","year":"2015","unstructured":"Knop L, Gandini LG Jr, Shintcovsk RL, Gandini MR. Scientific use of the finite element method in Orthodontics. Dental Press J Orthod. 2015;20(2):119\u201325. https:\/\/doi.org\/10.1590\/2176-9451.20.2.119-125.sar.","journal-title":"Dental Press J Orthod"},{"issue":"3","key":"356_CR15","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1093\/ejo\/cji082","volume":"28","author":"B Buranastidporn","year":"2005","unstructured":"Buranastidporn B, Hisano M, Soma K. Effect of biomechanical disturbance of the temporomandibular joint on the prevalence of internal derangement in mandibular asymmetry. Eur J Orthod. 2005;28(3):199\u2013205. https:\/\/doi.org\/10.1093\/ejo\/cji082.","journal-title":"Eur J Orthod"},{"key":"356_CR16","unstructured":"Wheeler RC, Ash MM. Wheeler\u2019s dental anatomy, physiology, and occlusion, vol. ix: Saunders; 1984. p. 446."},{"issue":"3","key":"356_CR17","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/s0002-9416(72)90268-0","volume":"62","author":"LF Andrews","year":"1972","unstructured":"Andrews LF. The six keys to normal occlusion. Am J Orthod. 1972;62(3):296\u2013309. https:\/\/doi.org\/10.1016\/s0002-9416(72)90268-0.","journal-title":"Am J Orthod"},{"issue":"7","key":"356_CR18","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/j.dental.2003.08.003","volume":"20","author":"AN Natali","year":"2004","unstructured":"Natali AN, Pavan PG, Scarpa C. Numerical analysis of tooth mobility: formulation of a non-linear constitutive law for the periodontal ligament. Dent Mater. 2004;20(7):623\u20139. https:\/\/doi.org\/10.1016\/j.dental.2003.08.003.","journal-title":"Dent Mater"},{"issue":"4","key":"356_CR19","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.ajodo.2009.03.057","volume":"139","author":"D Farnsworth","year":"2011","unstructured":"Farnsworth D, Rossouw PE, Ceen RF, Buschang PH. Cortical bone thickness at common miniscrew implant placement sites. Am J Orthod Dentofac Orthop. 2011;139(4):495\u2013503. https:\/\/doi.org\/10.1016\/j.ajodo.2009.03.057.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"6","key":"356_CR20","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/0889-5406(87)90232-0","volume":"92","author":"K Tanne","year":"1987","unstructured":"Tanne K, Sakuda M, Burstone CJ. Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. Am J Orthod Dentofac Orthop. 1987;92(6):499\u2013505. https:\/\/doi.org\/10.1016\/0889-5406(87)90232-0.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"356_CR21","unstructured":"Surhone LM, Timpledon MT, Marseken SF. Von Mises yield criterion: VDM Publishing; 2010."},{"issue":"4","key":"356_CR22","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1043\/0003-3219(1973)043<0384:ACACOC>2.0.CO;2","volume":"43","author":"FW Worms","year":"1973","unstructured":"Worms FW, Isaacson RJ, Speidel TM. A concept and classification of centers of rotation and extraoral force systems. Angle Orthod. 1973;43(4):384\u2013401. https:\/\/doi.org\/10.1043\/0003-3219(1973)043<0384:ACACOC>2.0.CO;2.","journal-title":"Angle Orthod"},{"issue":"3","key":"356_CR23","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.ajodo.2018.09.017","volume":"156","author":"MJ Ammoury","year":"2019","unstructured":"Ammoury MJ, Mustapha S, Dechow PC, Ghafari JG. Two distalization methods compared in a novel patient-specific finite element analysis. Am J Orthod Dentofac Orthop. 2019;156(3):326\u201336. https:\/\/doi.org\/10.1016\/j.ajodo.2018.09.017.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"356_CR24","doi-asserted-by":"publisher","DOI":"10.1109\/BMEiCON.2016.7859598","volume-title":"Effects of miniscrew location on performance of distalization appliance (iPANDA)","author":"C Sukjamsri","year":"2016","unstructured":"Sukjamsri C, Suzuki B, Arun S, Suzuki E. Effects of miniscrew location on performance of distalization appliance (iPANDA); 2016. https:\/\/doi.org\/10.1109\/BMEiCON.2016.7859598."},{"key":"356_CR25","unstructured":"Nanda R. Esthetics and biomechanics in orthodontics: Elsevier\/Saunders; 2014."},{"issue":"4","key":"356_CR26","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1093\/ejo\/cjr130","volume":"36","author":"IJ Yu","year":"2014","unstructured":"Yu IJ, Kook YA, Sung SJ, Lee KJ, Chun YS, Mo SS. Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study. Eur J Orthod. 2014;36(4):394\u2013402. https:\/\/doi.org\/10.1093\/ejo\/cjr130.","journal-title":"Eur J Orthod"},{"issue":"3","key":"356_CR27","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1043\/0003-3219(1994)064<0189:RMVSNC>2.0.CO;2","volume":"64","author":"L Bondemark","year":"1994","unstructured":"Bondemark L, Kurol J, Bernhold M. Repelling magnets versus superelastic nickel-titanium coils in simultaneous distal movement of maxillary first and second molars. Angle Orthod. 1994;64(3):189\u201398. https:\/\/doi.org\/10.1043\/0003-3219(1994)064<0189:RMVSNC>2.0.CO;2.","journal-title":"Angle Orthod"},{"issue":"4","key":"356_CR28","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1043\/0003-3219(2005)75[532:EONSFA]2.0.CO;2","volume":"75","author":"A Mavropoulos","year":"2005","unstructured":"Mavropoulos A, Karamouzos A, Kiliaridis S, Papadopoulos MA. Efficiency of noncompliance simultaneous first and second upper molar distalization: a three-dimensional tooth movement analysis. Angle Orthod. 2005;75(4):532\u20139. https:\/\/doi.org\/10.1043\/0003-3219(2005)75[532:EONSFA]2.0.CO;2.","journal-title":"Angle Orthod"},{"issue":"3","key":"356_CR29","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/s0889-5406(00)70238-1","volume":"117","author":"TJ Bussick","year":"2000","unstructured":"Bussick TJ, McNamara JA Jr. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofac Orthop. 2000;117(3):333\u201343. https:\/\/doi.org\/10.1016\/s0889-5406(00)70238-1.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"5","key":"356_CR30","doi-asserted-by":"publisher","first-page":"290","DOI":"10.4041\/kjod.2016.46.5.290","volume":"46","author":"J-M Kang","year":"2016","unstructured":"Kang J-M, Park JH, Bayome M, et al. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage. Korean J Orthodon. 2016;46(5):290\u2013300.","journal-title":"Korean J Orthodon"},{"key":"356_CR31","first-page":"3","volume-title":"Biomechanics principles in mini-implant driven orthodontics","author":"M Upadhyay","year":"2020","unstructured":"Upadhyay M, Nanda R. Biomechanics principles in mini-implant driven orthodontics; 2020. p. 3\u201320."},{"issue":"2","key":"356_CR32","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.ajodo.2004.12.024","volume":"130","author":"HJ Kim","year":"2006","unstructured":"Kim HJ, Yun HS, Park HD, Kim DH, Park YC. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofac Orthop. 2006;130(2):177\u201382. https:\/\/doi.org\/10.1016\/j.ajodo.2004.12.024.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"5","key":"356_CR33","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.ajodo.2010.11.017","volume":"139","author":"EY Suzuki","year":"2011","unstructured":"Suzuki EY, Suzuki B. Placement and removal torque values of orthodontic miniscrew implants. Am J Orthod Dentofac Orthop. 2011;139(5):669\u201378. https:\/\/doi.org\/10.1016\/j.ajodo.2010.11.017.","journal-title":"Am J Orthod Dentofac Orthop"}],"container-title":["Progress in Orthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-021-00356-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40510-021-00356-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-021-00356-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T15:13:14Z","timestamp":1620054794000},"score":1,"resource":{"primary":{"URL":"https:\/\/progressinorthodontics.springeropen.com\/articles\/10.1186\/s40510-021-00356-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,3]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["356"],"URL":"https:\/\/doi.org\/10.1186\/s40510-021-00356-6","relation":{},"ISSN":["2196-1042"],"issn-type":[{"type":"electronic","value":"2196-1042"}],"subject":[],"published":{"date-parts":[[2021,5,3]]},"assertion":[{"value":"29 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethic approval number 4\/2561, Bangkokthonburi University Ethics Committee","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Available (if requested)","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12"}}