{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T22:11:06Z","timestamp":1794694266260,"version":"4.9.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T00:00:00Z","timestamp":1694995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T00:00:00Z","timestamp":1694995200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Prog Orthod."],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>To investigate the accuracy of torque, tip and rotation and linear intra-arch movements yielded by passive self-ligating lingual straight-wire appliances with brackets featuring square slots.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>Twenty-five adult Caucasian patients (16 females and 9 males; mean age 26.5\u2009\u00b1\u20094.3\u00a0years) with Class I or mild Class II head-to-head malocclusion were orthodontically treated via passive lingual self-ligating straight-wire appliances (ALIAS, Ormco, Orange, CA) with no extraction. Records were retrospectively analysed, and digital models of pre-treatment (<jats:italic>T<\/jats:italic>0), planned (<jats:italic>T<\/jats:italic>1) and achieved (<jats:italic>T<\/jats:italic>2) phase were acquired for both arches in each patient via an intraoral scanner (Medit I500 (iScan Medit, Seoul, Korea). VAM software (Vectra, Canfield Scientific, Fairfield, NJ, USA) was used to measure both angular values (torque, tip and rotation) and linear intra-arch widths (between canines, first and second premolars and first and second molars). Measurements were obtained for all the movements investigated for each tooth group (incisors, canines, premolars and molars), by arch (maxillary and mandibular) and for both arches at <jats:italic>T<\/jats:italic>0, <jats:italic>T<\/jats:italic>1 and <jats:italic>T<\/jats:italic>2. The accuracy of angular values was compared using Student's <jats:italic>t<\/jats:italic>-test against a hypothetical 100%, and among the various tooth groups by post-hoc tests. Transverse linear measurements were investigated by means of the non-parametric Friedman test. The significance threshold was set at 0.05.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean accuracy of angular values was 77.25\u2009\u00b1\u20097.71% for torque, 78.41\u2009\u00b1\u20096.17% for tip and 77.99\u2009\u00b1\u20096.58% for rotation. In all cases, however, there was a significant difference between planned and achieved movements, and accuracy was significantly lower than the hypothetical 100% for all tooth groups, individual arches and dentition (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). For intra-arch diameters, the greatest accuracy values were found for the anterior sectors (83.54\u2009\u00b1\u20095.19% for the maxillary inter-canine distance) and the lowest for the posterior sectors (67.28% for the maxillary inter-second molar distance).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Straight-wire lingual treatment with passive self-ligating appliances featuring with square slot displayed excellent clinical accuracy, albeit with statistical accuracy decreasing antero-posteriorly.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40510-023-00482-3","type":"journal-article","created":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T00:01:41Z","timestamp":1694995301000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Accuracy of lingual straight-wire orthodontic treatment with passive self-ligating brackets and square slot: a retrospective study"],"prefix":"10.1186","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-8897-9670","authenticated-orcid":false,"given":"Fabrizio","family":"Scisciola","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Palone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Scuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Scuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis T.","family":"Huanca Ghislanzoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Lombardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,18]]},"reference":[{"issue":"5","key":"482_CR1","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1093\/ejo\/cjq069","volume":"33","author":"HG Jeremiah","year":"2011","unstructured":"Jeremiah HG, Bister D, Newton JT. Social perceptions of adults wearing orthodontic appliances: a cross-sectional study. Eur J Orthod. 2011;33(5):476\u201382.","journal-title":"Eur J Orthod"},{"issue":"3","key":"482_CR2","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.ajodo.2006.05.031","volume":"131","author":"KB Miller","year":"2007","unstructured":"Miller KB, McGorray SP. A comparison of treatment impacts between Invisalign aligner and fixed appliance therapy during the first week of treatment. Am J Orthod Dentofacial Orthop. 2007;131(3):302.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"482_CR3","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1111\/ocr.12177","volume":"20","author":"M Zheng","year":"2017","unstructured":"Zheng M, Liu R, Ni Z, Yu Z. Efficiency, effectiveness and treatment stability of clear aligners: a systematic review and meta-analysis. Orthod Craniofac Res. 2017;20(3):127\u201333.","journal-title":"Orthod Craniofac Res"},{"issue":"5","key":"482_CR4","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1016\/j.ajodo.2019.11.025","volume":"159","author":"T Jiang","year":"2021","unstructured":"Jiang T, Jiang YN, Chu FT, Lu PJ, Tang GH. A cone-beam computed tomographic study evaluating the efficacy of incisor movement with clear aligners: assessment of incisor pure tipping, controlled tipping, translation, and torque. Am J Orthod Dentofacial Orthop. 2021;159(5):635\u201343.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"482_CR5","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.ajodo.2020.06.041","volume":"160","author":"FF Dai","year":"2021","unstructured":"Dai FF, Xu TM, Shu G. Comparison of achieved and predicted crown movement in adults after 4 first premolar extraction treatment with Invisalign. Am J Orthod Dentofacial Orthop. 2021;160(6):805\u201313.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"482_CR6","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.ajodo.2019.12.015","volume":"158","author":"N Haouili","year":"2020","unstructured":"Haouili N, Kravitz ND, Vaid NR, Ferguson DJ, Makki L. Has Invisalign improved? A prospective follow-up study on the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop. 2020;158(3):420\u20135.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"4","key":"482_CR7","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.ajodo.2016.09.022","volume":"151","author":"R Khosravi","year":"2017","unstructured":"Khosravi R, Cohanim B, Hujoel P, Daher S, Neal M, Liu W, Huang G. Management of overbite with the Invisalign appliance. Am J Orthod Dentofacial Orthop. 2017;151(4):691-699.e2.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"482_CR8","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1093\/ejo\/cjz094","volume":"42","author":"SN Papageorgiou","year":"2020","unstructured":"Papageorgiou SN, Koletsi D, Iliadi A, Peltomaki T, Eliades T. Treatment outcome with orthodontic aligners and fixed appliances: a systematic review with meta-analyses. Eur J Orthod. 2020;42(3):331\u201343.","journal-title":"Eur J Orthod"},{"issue":"1","key":"482_CR9","doi-asserted-by":"publisher","first-page":"109","DOI":"10.2319\/031419-198.1","volume":"90","author":"M F\u00f6rsch","year":"2020","unstructured":"F\u00f6rsch M, Krull L, Hechtner M, Rahimi R, Wriedt S, Wehrbein H, Jacobs C, Jacobs C. Perception of esthetic orthodontic appliances: an eye tracking and cross-sectional study. Angle Orthod. 2020;90(1):109\u201317.","journal-title":"Angle Orthod"},{"issue":"1","key":"482_CR10","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s40510-014-0038-9","volume":"15","author":"L Lombardo","year":"2014","unstructured":"Lombardo L, Scuzzo G, Arreghini A, Gorgun O, Ortan YO, Siciliani G. 3D FEM comparison of lingual and labial orthodontics in en masse retraction. Prog Orthod. 2014;15(1):38.","journal-title":"Prog Orthod"},{"issue":"6","key":"482_CR11","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1016\/j.ajodo.2018.07.018","volume":"155","author":"F Ata-Ali","year":"2019","unstructured":"Ata-Ali F, Plasencia E, Lanuza-Garcia A, Ferrer-Molina M, Melo M, Ata-Ali J. Effectiveness of lingual versus labial fixed appliances in adults according to the Peer Assessment Rating index. Am J Orthod Dentofacial Orthop. 2019;155(6):819\u201325.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"482_CR12","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1111\/eos.12250","volume":"124","author":"SN Papageorgiou","year":"2016","unstructured":"Papageorgiou SN, G\u00f6lz L, J\u00e4ger A, Eliades T, Bourauel C. Lingual versus labial fixed orthodontic appliances: systematic review and meta-analysis of treatment effects. Eur J Oral Sci. 2016;124(2):105\u201318.","journal-title":"Eur J Oral Sci."},{"key":"482_CR13","unstructured":"Scuzzo G, Takemoto K, Takemoto Y, Takemoto A, Lombardo L. A new lingual straight-wire technique. J Clin Orthod. 2010;44(2):114\u201323; quiz 106."},{"issue":"3","key":"482_CR14","doi-asserted-by":"publisher","first-page":"507","DOI":"10.2319\/032511-213.1","volume":"82","author":"L Lombardo","year":"2012","unstructured":"Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2012;82(3):507\u201321.","journal-title":"Angle Orthod"},{"issue":"1","key":"482_CR15","first-page":"120","volume":"9","author":"L Lombardo","year":"2011","unstructured":"Lombardo L, Arreghini A, Al Ardha K, Scuzzo G, Takemoto K, Siciliani G. Wire load-deflection characteristics relative to different types of brackets. Int Orthod. 2011;9(1):120\u201339.","journal-title":"Int Orthod."},{"key":"482_CR16","first-page":"5","volume":"3","author":"T Stamm","year":"2000","unstructured":"Stamm T, Wiechmann D, Heinecken A, Ehmer U. Relation between second and third order problems in lingual orthodontic treatment. J Ling Orthod. 2000;3:5\u201311.","journal-title":"J Ling Orthod"},{"key":"482_CR17","unstructured":"Scuzzo G, Takemoto K, Takemoto Y, Scuzzo G, Lombardo L. A new self-ligating lingual bracket with square slots. J Clin Orthod. 2011;45(12):682\u201390; quiz 692."},{"issue":"1","key":"482_CR18","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s40510-016-0140-2","volume":"17","author":"L Lombardo","year":"2016","unstructured":"Lombardo L, Carlucci A, Palone M, Mollica F, Siciliani G. Stiffness comparison of mushroom and straight SS and TMA lingual archwires. Prog Orthod. 2016;17(1):27.","journal-title":"Prog Orthod"},{"key":"482_CR19","unstructured":"Komori A, Takemoto K, Shimoda T, Miyashita W, Scuzzo G. Precise direct lingual bonding with the KommonBase. J Clin Orthod. 2013;47(1):42\u20139; quiz 63\u20134."},{"key":"482_CR20","volume-title":"Lingual orthodontics: a new approach using Stb light lingual system & lingual straight wire","author":"G Scuzzo","year":"2010","unstructured":"Scuzzo G, Takemoto K. Lingual orthodontics: a new approach using Stb light lingual system & lingual straight wire. Hanover Park: Quintessence publishing Co; 2010."},{"issue":"6","key":"482_CR21","first-page":"381","volume":"35","author":"AH Owen 3rd","year":"2001","unstructured":"Owen AH 3rd. Accelerated Invisalign treatment. J Clin Orthod. 2001;35(6):381\u20135.","journal-title":"J Clin Orthod"},{"key":"482_CR22","volume-title":"Orthodontic set up","author":"G Scuzzo","year":"2014","unstructured":"Scuzzo G, Takemoto K, Lombardo L. Orthodontic set up. Hanover Park: Quintessence Publishing Co; 2014."},{"key":"482_CR23","doi-asserted-by":"publisher","first-page":"6","DOI":"10.2319\/031522-220.1","volume":"92","author":"P Albertini","year":"2022","unstructured":"Albertini P, Albertini E, Pellitteri F, Ghislanzoni LH, Lombardo L. Accuracy of planned tooth movement with lingual straight wire technique. Angle Orthod. 2022;92:6.","journal-title":"Angle Orthod."},{"issue":"3","key":"482_CR24","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.ajodo.2011.01.020","volume":"140","author":"D Grauer","year":"2011","unstructured":"Grauer D, Proffit WR. Accuracy in tooth positioning with a fully customized lingual orthodontic appliance. Am J Orthod Dentofacial Orthop. 2011;140(3):433\u201343.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"1","key":"482_CR25","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1007\/s00056-016-0058-9","volume":"78","author":"A Pauls","year":"2017","unstructured":"Pauls A, Nienkemper M, Schwestka-Polly R, Wiechmann D. Therapeutic accuracy of completely customized lingual appliance WIN. J Orofac Orthop. 2017;78(1):52\u201361.","journal-title":"J Orofac Orthop"},{"issue":"5","key":"482_CR26","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1007\/s00056-010-1027-3","volume":"71","author":"AH Pauls","year":"2010","unstructured":"Pauls AH. Therapeutic accuracy of individualized brackets in lingualorthodontics. J Orofac Orthop. 2010;71(5):348\u201361.","journal-title":"J Orofac Orthop"},{"key":"482_CR27","first-page":"14","volume":"26","author":"LT Huanca Ghislanzoni","year":"2013","unstructured":"Huanca Ghislanzoni LT, Lineberger M, Cevidanes LH, Mapelli A, Sforza C, McNamara JA Jr. Evaluation of tip and torque on virtual study models: a validation study. Prog Orthod. 2013;26:14\u20139.","journal-title":"Prog Orthod"},{"issue":"1","key":"482_CR28","first-page":"46","volume":"35","author":"K Takemoto","year":"2001","unstructured":"Takemoto K, Scuzzo G. The straight-wire concept in lingual orthodontics. J Clin Orthod. 2001;35(1):46\u201352.","journal-title":"J Clin Orthod"},{"issue":"1","key":"482_CR29","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s40510-017-0190-0","volume":"18","author":"L Lombardo","year":"2017","unstructured":"Lombardo L, Arreghini A, Ramina F, HuancaGhislanzoni LT, Siciliani G. Predictability of orthodontic movement with orthodontic aligners: a retrospective study. Prog Orthod. 2017;18(1):35.","journal-title":"Prog Orthod"},{"key":"482_CR30","volume-title":"Contemporary implant dentistry","author":"CE Misch","year":"2008","unstructured":"Misch CE. Contemporary implant dentistry. 4th ed. Mosby; 2008.","edition":"4"}],"container-title":["Progress in Orthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-023-00482-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40510-023-00482-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-023-00482-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T12:38:39Z","timestamp":1700311119000},"score":1,"resource":{"primary":{"URL":"https:\/\/progressinorthodontics.springeropen.com\/articles\/10.1186\/s40510-023-00482-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,18]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["482"],"URL":"https:\/\/doi.org\/10.1186\/s40510-023-00482-3","relation":{},"ISSN":["2196-1042"],"issn-type":[{"value":"2196-1042","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,18]]},"assertion":[{"value":"3 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Participants were informed that their records might be used for research purposes and provided retrospective written consent for this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent to publication was obtained from each participant, who were are informed that their sensitive data would not be divulged.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Dr. G. Scuzzo is the inventor and patent owner of self-ligating lingual bracket with square slot.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}],"article-number":"30"}}