{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T18:55:33Z","timestamp":1791658533151,"version":"4.3.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Prog Orthod."],"DOI":"10.1186\/s40510-026-00613-6","type":"journal-article","created":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T13:19:49Z","timestamp":1772198389000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Reliability of AI-driven cephalometric analysis on CBCT: comparison with manual 2D cephalometry"],"prefix":"10.1186","volume":"27","author":[{"given":"Natalia","family":"Kazimierczak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natalia","family":"Chwar\u015bcianek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nora","family":"Sultani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanna","family":"Janiszewska-Olszowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Jankowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anita","family":"Nowicka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zbigniew","family":"Serafin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wojciech","family":"Kazimierczak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"key":"613_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2015.09.007","author":"MG Hans","year":"2015","unstructured":"Hans MG, Martin Palomo J, Valiathan M. History of imaging in orthodontics from Broadbent to cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2015. https:\/\/doi.org\/10.1016\/j.ajodo.2015.09.007.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"613_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-023-03452-7","author":"S Yang","year":"2023","unstructured":"Yang S, Song ES, Lee ES, Kang SR, Yi WJ, Lee SP. Ceph-net: automatic detection of cephalometric landmarks on scanned lateral cephalograms from children and adolescents using an attention-based stacked regression network. BMC Oral Health. 2023. https:\/\/doi.org\/10.1186\/s12903-023-03452-7.","journal-title":"BMC Oral Health"},{"key":"613_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2010.09.021","author":"L Devereux","year":"2011","unstructured":"Devereux L, Moles D, Cunningham SJ, McKnight M. How important are lateral cephalometric radiographs in orthodontic treatment planning? Am J Orthod Dentofacial Orthop. 2011. https:\/\/doi.org\/10.1016\/j.ajodo.2010.09.021.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"613_CR4","first-page":"155","volume":"74","author":"YJ Chen","year":"2004","unstructured":"Chen YJ, Chen SK, Yao JCC, Chang HF. The effects of differences in landmark identification on the cephalometric measurements in traditional versus digitized cephalometry. Angle Orthod. 2004;74:155\u201361.","journal-title":"Angle Orthod"},{"key":"613_CR5","first-page":"394","volume":"76","author":"HL Dias Da Silveira","year":"2006","unstructured":"Dias Da Silveira HL, Dias Silveira HE. Reproducibility of cephalometric measurements made by three radiology clinics. Angle Orthod. 2006;76:394\u20139.","journal-title":"Angle Orthod"},{"key":"613_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13020344","author":"N Kazimierczak","year":"2024","unstructured":"Kazimierczak N, Kazimierczak W, Serafin Z, Nowicki P, No\u017cewski J, Janiszewska-Olszowska J. AI in orthodontics: revolutionizing diagnostics and treatment planning\u2014a comprehensive review. J Clin Med. 2024. https:\/\/doi.org\/10.3390\/jcm13020344.","journal-title":"J Clin Med"},{"key":"613_CR7","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1016\/j.jds.2020.06.019","volume":"16","author":"SB Khanagar","year":"2021","unstructured":"Khanagar SB, Al-ehaideb A, Maganur PC, Vishwanathaiah S, Patil S, Baeshen HA, et al. Developments, application, and performance of artificial intelligence in dentistry\u2014a systematic review. J Dent Sci. 2021;16:508\u201322. https:\/\/doi.org\/10.1016\/j.jds.2020.06.019.","journal-title":"J Dent Sci"},{"key":"613_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-022-00766-w","author":"G de Queiroz Tavares Borges Mesquita","year":"2023","unstructured":"de Queiroz Tavares Borges Mesquita G, Vieira WA, Vidigal MTC, Traven\u00e7olo BAN, Beaini TL, Spin-Neto R, et al. Artificial intelligence for detecting cephalometric landmarks: a systematic review and meta-analysis. J Digit Imaging. 2023. https:\/\/doi.org\/10.1007\/s10278-022-00766-w.","journal-title":"J Digit Imaging"},{"key":"613_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-021-03990-w","author":"F Schwendicke","year":"2021","unstructured":"Schwendicke F, Chaurasia A, Arsiwala L, Lee JH, Elhennawy K, Jost-Brinkmann PG, et al. Deep learning for cephalometric landmark detection: systematic review and meta-analysis. Clin Oral Investig. 2021. https:\/\/doi.org\/10.1007\/s00784-021-03990-w.","journal-title":"Clin Oral Investig"},{"key":"613_CR10","volume":"25","author":"JM Palomo","year":"2005","unstructured":"Palomo JM, Yang CY, Hans MG. Clinical application of three-dimensional craniofacial imaging in orthodontics. J Med Sci. 2005;25:269.","journal-title":"J Med Sci"},{"key":"613_CR11","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12206621","volume":"12","author":"N Kazimierczak","year":"2023","unstructured":"Kazimierczak N, Kazimierczak W, Serafin Z, Nowicki P, Lemanowicz A, Nadolska K, et al. Correlation analysis of nasal septum deviation and results of AI-driven automated 3D cephalometric analysis. J Clin Med. 2023;12:6621. https:\/\/doi.org\/10.3390\/jcm12206621.","journal-title":"J Clin Med"},{"key":"613_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ortho.2018.03.013","author":"M Ed-Dhahraouy","year":"2018","unstructured":"Ed-Dhahraouy M, Riri H, Ezzahmouly M, Bourzgui F, El Moutaoukkil A. A new methodology for automatic detection of reference points in 3D cephalometry: a pilot study. Int Orthod. 2018. https:\/\/doi.org\/10.1016\/j.ortho.2018.03.013.","journal-title":"Int Orthod"},{"key":"613_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-015-1173-6","author":"A Gupta","year":"2015","unstructured":"Gupta A, Kharbanda OP, Sardana V, Balachandran R, Sardana HK. A knowledge-based algorithm for automatic detection of cephalometric landmarks on CBCT images. Int J Comput Assist Radiol Surg. 2015. https:\/\/doi.org\/10.1007\/s11548-015-1173-6.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"613_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.2093","author":"Q Ma","year":"2020","unstructured":"Ma Q, Kobayashi E, Fan B, Nakagawa K, Sakuma I, Masamune K, et al. Automatic 3D landmarking model using patch-based deep neural networks for CT image of oral and maxillofacial surgery. Int J Med Robot Comput Assist Surg. 2020. https:\/\/doi.org\/10.1002\/rcs.2093.","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"613_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2017.08.028","author":"J Mont\u00fafar","year":"2018","unstructured":"Mont\u00fafar J, Romero M, Scougall-Vilchis RJ. Hybrid approach for automatic cephalometric landmark annotation on cone-beam computed tomography volumes. Am J Orthod Dentofacial Orthop. 2018. https:\/\/doi.org\/10.1016\/j.ajodo.2017.08.028.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"613_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-015-1334-7","author":"A Gupta","year":"2016","unstructured":"Gupta A, Kharbanda OP, Sardana V, Balachandran R, Sardana HK. Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm. Int J Comput Assist Radiol Surg. 2016. https:\/\/doi.org\/10.1007\/s11548-015-1334-7.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"613_CR17","doi-asserted-by":"publisher","first-page":"77","DOI":"10.4041\/kjod.2021.51.2.77","volume":"51","author":"M-J Kim","year":"2021","unstructured":"Kim M-J, Liu Y, Oh SH, Ahn H-W, Kim S-H, Nelson G. Evaluation of a multi-stage convolutional neural network-based fully automated landmark identification system using cone-beam computed tomographysynthesized posteroanterior cephalometric images. Korean J Orthod. 2021;51:77\u201385. https:\/\/doi.org\/10.4041\/kjod.2021.51.2.77.","journal-title":"Korean J Orthod"},{"key":"613_CR18","first-page":"1","volume":"23","author":"AA Muraev","year":"2020","unstructured":"Muraev AA, Tsai P, Kibardin I, Oborotistov N, Shirayeva T, Ivanov S, et al. Frontal cephalometric landmarking: humans vs artificial neural networks. Int J Comput Dent. 2020;23:1.","journal-title":"Int J Comput Dent"},{"key":"613_CR19","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjae029","author":"J Hendrickx","year":"2024","unstructured":"Hendrickx J, Gracea RS, Vanheers M, Winderickx N, Preda F, Shujaat S, et al. Can artificial intelligence-driven cephalometric analysis replace manual tracing? A systematic review and meta-analysis. Eur J Orthod. 2024. https:\/\/doi.org\/10.1093\/ejo\/cjae029.","journal-title":"Eur J Orthod"},{"key":"613_CR20","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-023-02881-8","volume":"23","author":"H Bao","year":"2023","unstructured":"Bao H, Zhang K, Yu C, Li H, Cao D, Shu H, et al. Evaluating the accuracy of automated cephalometric analysis based on artificial intelligence. BMC Oral Health. 2023;23:191. https:\/\/doi.org\/10.1186\/s12903-023-02881-8.","journal-title":"BMC Oral Health"},{"key":"613_CR21","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2020200038","author":"OS Pianykh","year":"2020","unstructured":"Pianykh OS, Langs G, Dewey M, Enzmann DR, Herold CJ, Schoenberg SO, et al. Continuous learning AI in radiology: implementation principles and early applications. Radiology. 2020. https:\/\/doi.org\/10.1148\/radiol.2020200038.","journal-title":"Radiology"},{"key":"613_CR22","unstructured":"Kula KK, Ghoneima A. Cephalometry in Orthodontics 2D and 3D. 1st ed. Quintessence Publishing; 2018."},{"key":"613_CR23","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/096228029900800204","volume":"8","author":"JM Bland","year":"1999","unstructured":"Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135\u201360. https:\/\/doi.org\/10.1177\/096228029900800204.","journal-title":"Stat Methods Med Res"},{"key":"613_CR24","doi-asserted-by":"publisher","DOI":"10.1053\/j.sodo.2025.06.002","author":"N Pandis","year":"2025","unstructured":"Pandis N, Burzykowski T. Comparing prescribed and achieved treatment outcomes in digitally planned orthodontic treatment: statistical approaches. Semin Orthod. 2025. https:\/\/doi.org\/10.1053\/j.sodo.2025.06.002.","journal-title":"Semin Orthod"},{"key":"613_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9416(83)90322-6","author":"WJB Houston","year":"1983","unstructured":"Houston WJB. The analysis of errors in orthodontic measurements. Am J Orthod. 1983. https:\/\/doi.org\/10.1016\/0002-9416(83)90322-6.","journal-title":"Am J Orthod"},{"key":"613_CR26","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/37010910","author":"SF AlBarakati","year":"2012","unstructured":"AlBarakati SF, Kula KS, Ghoneima AA. The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods. Dentomaxillofac Radiol. 2012. https:\/\/doi.org\/10.1259\/dmfr\/37010910.","journal-title":"Dentomaxillofac Radiol"},{"key":"613_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2010.05.013","author":"J Damstra","year":"2010","unstructured":"Damstra J, Huddleston Slater JJR, Fourie Z, Ren Y. Reliability and the smallest detectable differences of lateral cephalometric measurements. Am J Orthod Dentofacial Orthop. 2010. https:\/\/doi.org\/10.1016\/j.ajodo.2010.05.013.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"613_CR28","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.radonc.2019.09.004","volume":"141","author":"A Kopp-Schneider","year":"2019","unstructured":"Kopp-Schneider A, Hielscher T. How to evaluate agreement between quantitative measurements. Radiother Oncol. 2019;141:321\u20136. https:\/\/doi.org\/10.1016\/j.radonc.2019.09.004.","journal-title":"Radiother Oncol"},{"key":"613_CR29","doi-asserted-by":"publisher","DOI":"10.1037\/0033-2909.86.2.420","author":"PE Shrout","year":"1979","unstructured":"Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979. https:\/\/doi.org\/10.1037\/0033-2909.86.2.420.","journal-title":"Psychol Bull"},{"key":"613_CR30","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2006.876638","author":"W Yue","year":"2006","unstructured":"Yue W, Yin D, Li C, Wang G, Xu T. Automated 2-D cephalometric analysis on X-ray images by a model-based approach. IEEE Trans Biomed Eng. 2006. https:\/\/doi.org\/10.1109\/TBME.2006.876638.","journal-title":"IEEE Trans Biomed Eng"},{"key":"613_CR31","doi-asserted-by":"publisher","DOI":"10.5152\/TURKJORTHOD.2020.20062","author":"P Meri\u00c3","year":"2020","unstructured":"Meri\u00c3 P, Naoumova J. Web-based fully automated cephalometric analysis: comparisons between app-aided, computerized, and manual tracings. Turk J Orthod. 2020. https:\/\/doi.org\/10.5152\/TURKJORTHOD.2020.20062.","journal-title":"Turk J Orthod"},{"key":"613_CR32","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-023-01629-2","author":"M Serafin","year":"2023","unstructured":"Serafin M, Baldini B, Cabitza F, Carrafiello G, Baselli G, Del Fabbro M, et al. Accuracy of automated 3D cephalometric landmarks by deep learning algorithms: systematic review and meta-analysis. Radiol Med. 2023. https:\/\/doi.org\/10.1007\/s11547-023-01629-2.","journal-title":"Radiol Med"},{"key":"613_CR33","doi-asserted-by":"publisher","DOI":"10.2319\/080311-488.1","author":"M Nur","year":"2012","unstructured":"Nur M, Kayipmaz S, Bayram M, Celikoglu M, Kilkis D, Sezgin OS. Conventional frontal radiographs compared with frontal radiographs obtained from cone beam computed tomography. Angle Orthod. 2012. https:\/\/doi.org\/10.2319\/080311-488.1.","journal-title":"Angle Orthod"},{"key":"613_CR34","doi-asserted-by":"publisher","DOI":"10.2319\/070810-387.1","author":"H Olmez","year":"2011","unstructured":"Olmez H, Gorgulu S, Akin E, Bengi AO, Tekdemir I, Ors F. Measurement accuracy of a computer-assisted three-dimensional analysis and a conventional two-dimensional method. Angle Orthod. 2011. https:\/\/doi.org\/10.2319\/070810-387.1.","journal-title":"Angle Orthod"},{"key":"613_CR35","doi-asserted-by":"publisher","DOI":"10.5624\/isd.2012.42.4.201","author":"CS Park","year":"2012","unstructured":"Park CS, Park JK, Kim H, Han SS, Jeong HG, Park H. Comparison of conventional lateral cephalograms with corresponding CBCT radiographs. Imaging Sci Dent. 2012. https:\/\/doi.org\/10.5624\/isd.2012.42.4.201.","journal-title":"Imaging Sci Dent"},{"key":"613_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2008.07.008","author":"PM Cattaneo","year":"2008","unstructured":"Cattaneo PM, Bloch CB, Calmar D, Hjortsh\u00f8j M, Melsen B. Comparison between conventional and cone-beam computed tomography-generated cephalograms. Am J Orthod Dentofacial Orthop. 2008. https:\/\/doi.org\/10.1016\/j.ajodo.2008.07.008.","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["Progress in Orthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-026-00613-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40510-026-00613-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40510-026-00613-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T13:19:51Z","timestamp":1772198391000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40510-026-00613-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,27]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["613"],"URL":"https:\/\/doi.org\/10.1186\/s40510-026-00613-6","relation":{},"ISSN":["2196-1042"],"issn-type":[{"value":"2196-1042","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,27]]},"assertion":[{"value":"28 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was conducted in accordance with the principles of the Declaration of Helsinki and was approved by the Ethics Committee of anonymized for peer review. The requirement for informed consent was waived due to the retrospective nature of the study and anonymization of patient data.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8"}}