{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T06:26:56Z","timestamp":1794378416660,"version":"4.9.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,20]],"date-time":"2021-12-20T00:00:00Z","timestamp":1639958400000},"content-version":"vor","delay-in-days":19,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"abiomed"},{"DOI":"10.13039\/100000057","name":"national institute of general medical sciences","doi-asserted-by":"publisher","award":["R01GM049039"],"award-info":[{"award-number":["R01GM049039"]}],"id":[{"id":"10.13039\/100000057","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000050","name":"national heart, lung, and blood institute","doi-asserted-by":"publisher","award":["K08HL143342"],"award-info":[{"award-number":["K08HL143342"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008552","name":"brigham research institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008552","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Acute heart failure and cardiogenic shock remain highly morbid conditions despite prompt medical therapy in critical care settings. Mechanical circulatory support (MCS) is a promising therapy for these patients, yet remains managed with open-loop control. Continuous measure of cardiac function would support and optimize MCS deployment and weaning. The nature of indwelling MCS provides a platform for attaining this information. This study investigates how hysteresis modeling derived from MCS device signals can be used to assess contractility changes to provide continuous indication of changing cardiac state. Load-dependent MCS devices vary their operation with cardiac state to yield a device\u2013heart hysteretic interaction. Predicting and examining this hysteric relation provides insight into cardiac state and can be separated by cardiac cycle phases. Here, we demonstrate this by predicting hysteresis and using the systolic portion of the hysteresis loop to estimate changes in native contractility. This study quantified this measurement as the enclosed area of the systolic portion of the hysteresis loop and correlated it with other widely accepted contractility metrics in animal studies (<jats:italic>n<\/jats:italic>\u2009=\u20094) using acute interventions that alter inotropy, including a heart failure model. Clinical validation was performed in patients (<jats:italic>n<\/jats:italic>\u2009=\u20098) undergoing Impella support.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Hysteresis is well estimated from device signals alone (<jats:italic>r<\/jats:italic>\u2009=\u20090.92, limits of agreement: \u2212\u20090.18 to 0.18). Quantified systolic area was well correlated in animal studies with end-systolic pressure\u2013volume relationship (<jats:italic>r<\/jats:italic>\u2009=\u20090.84), preload recruitable stroke work index (<jats:italic>r<\/jats:italic>\u2009=\u20090.77), and maximum slope of left ventricular pressure (d<jats:italic>P<\/jats:italic>\/d<jats:italic>t<\/jats:italic><jats:sub>max<\/jats:sub>) (<jats:italic>r<\/jats:italic>\u2009=\u20090.95) across a range of inotropic conditions. Comparable results were seen in patients with d<jats:italic>P<\/jats:italic>\/d<jats:italic>t<\/jats:italic><jats:sub>max<\/jats:sub> (<jats:italic>r<\/jats:italic>\u2009=\u20090.88). Diagnostic capability from ROC analysis yielded AUC measurements of 0.92 and 0.90 in animal and patients, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Mechanical circulatory support hysteretic behavior can be well modeled using device signals and used to estimate contractility changes. Contractility estimate is correlated with other accepted metrics, captures temporal trends that elucidate changing cardiac state, and is able to accurately indicate changes in inotropy. Inherently available during MCS deployment, this measure will guide titration and inform need for further intervention.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40635-021-00426-3","type":"journal-article","created":{"date-parts":[[2021,12,20]],"date-time":"2021-12-20T14:05:17Z","timestamp":1640009117000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Hysteretic device characteristics indicate cardiac contractile state for guiding mechanical circulatory support device use"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3067-2353","authenticated-orcid":false,"given":"Brian Y.","family":"Chang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengyang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noam","family":"Josephy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven P.","family":"Keller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elazer R.","family":"Edelman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,12,20]]},"reference":[{"key":"426_CR1","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1002\/ejhf.260","volume":"17","author":"VP Harjola","year":"2015","unstructured":"Harjola VP, Lassus J, Sionis A et al (2015) Clinical picture and risk prediction of short-term mortality in cardiogenic shock. Eur J Heart Fail 17:501\u2013509. https:\/\/doi.org\/10.1002\/ejhf.260","journal-title":"Eur J Heart Fail"},{"key":"426_CR2","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1056\/NEJMra1208943","volume":"369","author":"JL Vincent","year":"2013","unstructured":"Vincent JL, De Backer D (2013) Circulatory shock. N Engl J Med 369:1726\u20131734. https:\/\/doi.org\/10.1056\/NEJMra1208943","journal-title":"N Engl J Med"},{"key":"426_CR3","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1056\/NEJMoa1208200","volume":"369","author":"DS Menees","year":"2013","unstructured":"Menees DS, Peterson ED, Wang Y et al (2013) Door-to-balloon time and mortality among patients undergoing primary PCI. N Engl J Med 369:901\u2013909. https:\/\/doi.org\/10.1056\/NEJMoa1208200","journal-title":"N Engl J Med"},{"key":"426_CR4","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1038\/nrcardio.2016.96","volume":"13","author":"A Reyentovich","year":"2016","unstructured":"Reyentovich A, Barghash MH, Hochman JS (2016) Management of refractory cardiogenic shock. Nat Rev Cardiol 13:481\u2013492. https:\/\/doi.org\/10.1038\/nrcardio.2016.96","journal-title":"Nat Rev Cardiol"},{"key":"426_CR5","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1007\/s12265-018-9809-x","volume":"12","author":"G Sunagawa","year":"2018","unstructured":"Sunagawa G, Saku K, Arimura T et al (2018) Mechano-chronotropic unloading during the acute phase of myocardial infarction markedly reduces infarct size via the suppression of myocardial oxygen consumption. J Cardiovasc Transl Res 12:124\u2013134. https:\/\/doi.org\/10.1007\/s12265-018-9809-x","journal-title":"J Cardiovasc Transl Res"},{"key":"426_CR6","doi-asserted-by":"publisher","first-page":"1881","DOI":"10.1016\/j.jacc.2015.12.074","volume":"67","author":"L Miller","year":"2016","unstructured":"Miller L (2016) Cardiogenic shock in acute myocardial infarction the era of mechanical support. J Am Coll Cardiol 67:1881\u20131884. https:\/\/doi.org\/10.1016\/j.jacc.2015.12.074","journal-title":"J Am Coll Cardiol"},{"key":"426_CR7","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1097\/MAT.0000000000000201","volume":"61","author":"GA Giridharan","year":"2015","unstructured":"Giridharan GA, Koenig SC, Soucy KG et al (2015) Left ventricular volume unloading with axial and centrifugal rotary blood pumps. ASAIO J 61:292\u2013300. https:\/\/doi.org\/10.1097\/MAT.0000000000000201","journal-title":"ASAIO J"},{"key":"426_CR8","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.117.004397","volume":"11","author":"K Saku","year":"2018","unstructured":"Saku K, Kakino T, Arimura T et al (2018) Left ventricular mechanical unloading by total support of impella in myocardial infarction reduces infarct size, preserves left ventricular function, and prevents subsequent heart failure in dogs. Circ Hear Fail 11:e004397. https:\/\/doi.org\/10.1161\/CIRCHEARTFAILURE.117.004397","journal-title":"Circ Hear Fail"},{"key":"426_CR9","doi-asserted-by":"publisher","first-page":"338","DOI":"10.5301\/ijao.5000604","volume":"40","author":"MG Trivella","year":"2017","unstructured":"Trivella MG, Piersigilli A, Bernini F et al (2017) Percutaneous cardiac support during myocardial infarction drastically reduces mortality: perspectives from a swine model. Int J Artif Organs 40:338\u2013344. https:\/\/doi.org\/10.5301\/ijao.5000604","journal-title":"Int J Artif Organs"},{"key":"426_CR10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.118.005853","author":"J Tongers","year":"2020","unstructured":"Tongers J, Sieweke JT, K\u00fchn C et al (2020) Early escalation of mechanical circulatory support stabilizes and potentially rescues patients in refractory cardiogenic shock. Circ Heart Fail. https:\/\/doi.org\/10.1161\/CIRCHEARTFAILURE.118.005853","journal-title":"Circ Heart Fail"},{"key":"426_CR11","first-page":"280","volume":"7","author":"M Dandel","year":"2015","unstructured":"Dandel M, Hetzer R (2015) Myocardial recovery during mechanical circulatory support: weaning and explantation criteria. Hear lung Vessel 7:280\u2013288","journal-title":"Hear lung Vessel"},{"key":"426_CR12","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1177\/2048872617740834","volume":"7","author":"AR Garan","year":"2018","unstructured":"Garan AR, Eckhardt C, Takeda K et al (2018) Predictors of survival and ability to wean from short-term mechanical circulatory support device following acute myocardial infarction complicated by cardiogenic shock. Eur Hear J Acute Cardiovasc Care 7:755\u2013765. https:\/\/doi.org\/10.1177\/2048872617740834","journal-title":"Eur Hear J Acute Cardiovasc Care"},{"key":"426_CR13","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1111\/j.1525-1594.2012.01503.x","volume":"36","author":"M Granegger","year":"2012","unstructured":"Granegger M, Moscato F, Casas F et al (2012) Development of a pump flow estimator for rotary blood pumps to enhance monitoring of ventricular function. Artif Organs 36:691\u2013699. https:\/\/doi.org\/10.1111\/j.1525-1594.2012.01503.x","journal-title":"Artif Organs"},{"key":"426_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02510-3","author":"SP Keller","year":"2020","unstructured":"Keller SP, Chang BY, Tan Q et al (2020) Dynamic modulation of device-arterial coupling to determine cardiac output and vascular resistance. Ann Biomed Eng. https:\/\/doi.org\/10.1007\/s10439-020-02510-3","journal-title":"Ann Biomed Eng"},{"key":"426_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1126\/scitranslmed.aao2980","volume":"10","author":"BY Chang","year":"2018","unstructured":"Chang BY, Keller SP, Bhavsar SS et al (2018) Mechanical circulatory support device-heart hysteretic interaction can predict left ventricular end diastolic pressure. Sci Transl Med 10:1\u20139","journal-title":"Sci Transl Med"},{"key":"426_CR16","doi-asserted-by":"publisher","first-page":"2800","DOI":"10.1109\/TBME.2019.2895752","volume":"66","author":"BY Chang","year":"2019","unstructured":"Chang BY, Keller SP, Edelman ER (2019) Leveraging device-arterial coupling to determine cardiac and vascular state. IEEE Trans Biomed Eng 66:2800\u20132808. https:\/\/doi.org\/10.1109\/TBME.2019.2895752","journal-title":"IEEE Trans Biomed Eng"},{"key":"426_CR17","doi-asserted-by":"publisher","first-page":"433","DOI":"10.5301\/ijao.5000424","volume":"38","author":"KAMA Pennings","year":"2015","unstructured":"Pennings KAMA, van Tuijl S, van de Vosse FN et al (2015) Estimation of left ventricular pressure with the pump as \u201csensor\u201d in patients with a continuous flow LVAD. Int J Artif Organs 38:433\u2013443. https:\/\/doi.org\/10.5301\/ijao.5000424","journal-title":"Int J Artif Organs"},{"key":"426_CR18","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1046\/j.1525-1594.2001.06859.x","volume":"25","author":"G Endo","year":"2001","unstructured":"Endo G, Araki K, Kojima K et al (2001) The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. Artif Organs 25:697\u2013702. https:\/\/doi.org\/10.1046\/j.1525-1594.2001.06859.x","journal-title":"Artif Organs"},{"key":"426_CR19","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.healun.2009.05.032","volume":"29","author":"P Naiyanetr","year":"2010","unstructured":"Naiyanetr P, Moscato F, Vollkron M et al (2010) Continuous assessment of cardiac function during rotary blood pump support: a contractility index derived from pump flow. J Hear Lung Transpl 29:37\u201344. https:\/\/doi.org\/10.1016\/j.healun.2009.05.032","journal-title":"J Hear Lung Transpl"},{"key":"426_CR20","unstructured":"Chang BY (2018) Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions. Doctoral dissertation, Massachusetts Institute of Technology"},{"key":"426_CR21","doi-asserted-by":"crossref","unstructured":"Visintin A (2005) Mathematical models of hysteresis","DOI":"10.1016\/B978-012480874-4\/50004-X"},{"key":"426_CR22","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1177\/039139880202501107","volume":"25","author":"J Stoli\u0144ski","year":"2002","unstructured":"Stoli\u0144ski J, Rosenbaum C, Flameng W, Meyns B (2002) The heart-pump interaction: effects of a microaxial blood pump. Int J Artif Organs 25:1082\u20131088","journal-title":"Int J Artif Organs"},{"key":"426_CR23","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1177\/039139880903200604","volume":"32","author":"F Moscato","year":"2009","unstructured":"Moscato F, Danieli GA, Schima H (2009) Dynamic modeling and identification of an axial flow ventricular assist device. Int J Artif Organs 32:336\u2013343","journal-title":"Int J Artif Organs"},{"key":"426_CR24","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1109\/tbme.2020.3016220","volume":"68","author":"BY Chang","year":"2020","unstructured":"Chang BY, Moyer C, El Katerji A et al (2020) A scalable approach to determine intracardiac pressure from mechanical circulatory support device signals. IEEE Trans Biomed Eng 68:905\u2013913. https:\/\/doi.org\/10.1109\/tbme.2020.3016220","journal-title":"IEEE Trans Biomed Eng"},{"key":"426_CR25","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.00138.2005","author":"D Burkhoff","year":"2005","unstructured":"Burkhoff D, Mirsky I, Suga H (2005) Assessment of systolic and diastolic ventricular properties via pressure\u2013volume analysis: a guide for clinical, translational, and basic researchers. Am J Physiol. https:\/\/doi.org\/10.1152\/ajpheart.00138.2005","journal-title":"Am J Physiol"},{"key":"426_CR26","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1161\/01.CIR.71.5.994","volume":"71","author":"DD Glower","year":"1985","unstructured":"Glower DD, Spratt JA, Snow ND et al (1985) Linearity of the Frank-Starling relationship in the intact heart: the concept of preload recruitable stroke work. Circulation 71:994\u20131009. https:\/\/doi.org\/10.1161\/01.CIR.71.5.994","journal-title":"Circulation"},{"key":"426_CR27","doi-asserted-by":"publisher","first-page":"2663","DOI":"10.1016\/j.jacc.2015.10.017","volume":"66","author":"D Burkhoff","year":"2015","unstructured":"Burkhoff D, Sayer G, Doshi D, Uriel N (2015) Hemodynamics of mechanical circulatory support. J Am Coll Cardiol 66:2663\u20132674. https:\/\/doi.org\/10.1016\/j.jacc.2015.10.017","journal-title":"J Am Coll Cardiol"},{"key":"426_CR28","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1161\/01.CIR.44.1.47","volume":"44","author":"DT Mason","year":"1971","unstructured":"Mason DT, Braunwald E, Covell JW et al (1971) Assessment of cardiac contractility. The relation between the rate of pressure rise and ventricular pressure during isovolumic systole. Circulation 44:47\u201358. https:\/\/doi.org\/10.1161\/01.CIR.44.1.47","journal-title":"Circulation"},{"key":"426_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/CRD.0000000000000082","volume":"24","author":"UK Gidwani","year":"2016","unstructured":"Gidwani UK, Goel S (2016) The pulmonary artery catheter in 2015: the swan and the phoenix. Cardiol Rev 24:1\u201313","journal-title":"Cardiol Rev"},{"key":"426_CR30","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1097\/01.shk.0000209521.20496.7a","volume":"25","author":"E Aghajani","year":"2006","unstructured":"Aghajani E, Muller S, Kj\u00f8rstad KE et al (2006) The pressure\u2013volume loop revisited: is the search for a cardiac contractility index a futile cycle? Shock 25:370\u2013376. https:\/\/doi.org\/10.1097\/01.shk.0000209521.20496.7a","journal-title":"Shock"},{"key":"426_CR31","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/S0735-1097(99)00566-5","volume":"35","author":"MK Karunanithi","year":"2000","unstructured":"Karunanithi MK, Feneley MP (2000) Single-beat determination of preload recruitable stroke work relationship: derivation and evaluation in conscious dogs. J Am Coll Cardiol 35:502\u2013513. https:\/\/doi.org\/10.1016\/S0735-1097(99)00566-5","journal-title":"J Am Coll Cardiol"},{"key":"426_CR32","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1016\/j.echo.2011.04.016","volume":"24","author":"E Gayat","year":"2011","unstructured":"Gayat E, Ahmad H, Weinert L et al (2011) Reproducibility and inter-vendor variability of left ventricular deformation measurements by three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr 24:878\u2013885. https:\/\/doi.org\/10.1016\/j.echo.2011.04.016","journal-title":"J Am Soc Echocardiogr"},{"key":"426_CR33","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2018.1456","volume":"1","author":"PA Pellikka","year":"2018","unstructured":"Pellikka PA, She L, Holly TA et al (2018) Variability in ejection fraction measured by echocardiography, gated single-photon emission computed tomography, and cardiac magnetic resonance in patients with coronary artery disease and left ventricular dysfunction. JAMA 1:e181456. https:\/\/doi.org\/10.1001\/jamanetworkopen.2018.1456","journal-title":"JAMA"},{"key":"426_CR34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13054-020-2816-8","volume":"24","author":"NLJ Udesen","year":"2020","unstructured":"Udesen NLJ, Helgestad OKL, Banke ABS et al (2020) Impact of concomitant vasoactive treatment and mechanical left ventricular unloading in a porcine model of profound cardiogenic shock. Crit Care 24:1\u201310. https:\/\/doi.org\/10.1186\/s13054-020-2816-8","journal-title":"Crit Care"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-021-00426-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-021-00426-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-021-00426-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,20]],"date-time":"2021-12-20T14:18:47Z","timestamp":1640009927000},"score":1,"resource":{"primary":{"URL":"https:\/\/icm-experimental.springeropen.com\/articles\/10.1186\/s40635-021-00426-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["426"],"URL":"https:\/\/doi.org\/10.1186\/s40635-021-00426-3","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"1 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Animal studies were performed in accordance with NIH and AAALAC guidelines under an IACUC approved protocol. Data were obtained with informed consent and with approvals from an Ethics Review Committee and relevant Institutional Review Boards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"B.Y.C., N.J., and E.R.E. are co-inventors on granted U.S. patent 16\/455,835 assigned to the Massachusetts Institute of Technology that covers the extraction of hemodynamic metrics from mechanical circulatory support devices. Z.Z. and N.J. are currently employees of Abiomed, Inc. E.R.E. is the PI for the Educational Research Grant from Abiomed that supported this work. All other authors have no other conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"62"}}